• 제목/요약/키워드: Air permeability factor

검색결과 70건 처리시간 0.033초

알카리 전처리에 의한 NBKP의 형태학적 및 이화학적 변화 (Morphological and Physicochemical Changes of NBKP by Alkali Pretreatment)

  • 문성필;장민환
    • 펄프종이기술
    • /
    • 제41권4호
    • /
    • pp.58-64
    • /
    • 2009
  • This study was carried out to prepare high porosity pulp for oil and air filter media from commercial grade NBKP with 6 - 20% NaOH treatment. The fiber width of NBKP remarkably decreased by NaOH pretreatment. The air permeability of the test sheet prepared from alkali-pretreated NBKP increased with increasing NaOH concentration up to 15%. The burst factor was greatly decreased by alkali pretreatment. By 15 - 20% NaOH pretreatment of NBKP, it could be possible to prepare a high porosity pulp. It seems that the high porosity of the pulp was due to a strong swelling and a great change of the cellulose crystalline lattice from cellulose I to cellulose II with NaOH treatment of NBKP. The study suggested that alkali- pretreated NBKP could be used for manufacturing oil and air filter media.

Aeration Factor Used To Design The Container Type of Biopile Systems for Small-Scale Petroleum-Contaminated Soil Projects

  • Jung, Hyun-Gyu
    • 한국토양비료학회지
    • /
    • 제44권2호
    • /
    • pp.316-319
    • /
    • 2011
  • Biopiles which offer the potential for cost-effective treatment of contaminated soils are above-ground, engineered systems that use oxygen to stimulate the growth and reproduction of aerobic bacteria for degradation of the petroleum constituents adsorbed to soil in excavated soils. This technology involves heaping contaminated soils into piles and stimulating aerobic microbial activity within the soils through the aeration and/or addition of minerals, nutrients, and moisture. Inside the biopile, microbially mediated reactions by blowing or extracting air through the pipes can enhance degradation of the organic contaminants. The influence of a aeration system on the biopile performance was investigated. Air pressure made to compare the efficiency of suction in the pipes showed that there were slightly significant difference between the two piles in the total amount of TPH biodegradation. The normalised degradation rate was, however, considerably higher in the aeration system than in the normal system without aeration, suggesting that the vertical venting method may have improved the efficiency of the biological reactions in the pile.

중공 복합사 직물의 기공도 특성이 고감성 의류용 직물의 쾌적특성에 미치는 영향 (Effect of Porosity Characteristics of Hollow Composite Yarns to the Comfort Property of the Fabrics for the High Emotional Garment)

  • 김현아;김영수;김승진
    • 한국염색가공학회지
    • /
    • 제26권3호
    • /
    • pp.218-229
    • /
    • 2014
  • The wearing comfort of garment is governed by two kinds of characteristics such as moisture and thermal transport properties and mechanical properties of fabrics. The porosity influenced by yarn and fabric structural parameters is known as main factor for wearing comfort of garment related to the moisture and thermal transport properties. This study investigated effect of porosity of composite yarns to the moisture and thermal comfort properties of composite fabrics made of hollow composite DTY and ATY yarns. The theoretical porosity and pore size were inversely proportional to cover factor of fabric, but cover factor was not correlated with experimental pore size. The wicking property of hydrophobic PET filament fabric showed inferior result irrespective of porosity, pore size and cover factor. The drying rate was superior at composite fabrics with high pore size and low cover factor, and pore size was dominant factor for drying property. On the other hand, thermal conductivity of composite fabric was mainly influenced by cover factor and not influenced by porosity. Air permeability was influenced by both porosity and cover factor and was highly increased with increasing porosity and decreasing fabric cover factor.

저온소결 온도변화에 따른 Ni-Zn-Cu 페라이트의 자기적 특성 연구 (The Study of Magnetic Properties of Ni-Zn-Cu Ferrite by variation of Low Temperature Sintered)

  • 고재귀
    • 한국자기학회지
    • /
    • 제17권6호
    • /
    • pp.232-237
    • /
    • 2007
  • 기본조성 $(Ni_{0.2}Cu_{0.2}Zn_{0.6})_{1+x}(Fe_2O_3)_{1-x}$에서 $Fe_2O_3$가 약간 부족한 비화학양론적인 조성비를 택하여 Ni-Zn-Cu 페라이트의 입계에 높은 저항층을 형성하고 소결을 촉진시켜 낮은 손실, 높은 투자율 및 자기유도 와 주성분을 치환해서 스피넬 격자를 고용시킬 목적으로 $TiO_2$$Li_2CO_3$를 소량 첨가하였다. 이들 원료들을 혼합한 후 가소 후 소결온도 $875^{\circ}C,\;900^{\circ}C,\;925^{\circ}C$$950^{\circ}C$에서 소결하였다. 각 시편들에 대한 소결밀도는 $4.85\sim5.32g/cm^3$으로 나타났고, 각 시편들의 고유저항은 $10^8\sim10^{12}\Omega-cm$으로 측정되었다. 시편들의 자기유도 특성 값은 대략 $800\sim1300G$ 부근이었으며, $TiO_2$를 첨가한 경우보다 $Li_2CO_3$를 첨가한 경우가 약간 높게 측정되었다. 각각 시편들의 보자력은 $2.5\sim4.5$ Oe로 연자성 재료의 범위로 나타났다. 초투자율 및 품질계수는 각각 $125\sim275$$65\sim83$으로 나타나 Ni-Zn-Cu 페라미트에서 측정되는 값들과 대동소이했다. 물리적인 특성값(고유저항, 자기유도, 초투자율, 품질계수 등)으로 미루어 보마 각종 고주파영역(microwave영역까지 포함) 통신기기 코어 및 편향 요크 코어 등으로 응용이 가능하다.

콘크리트구조물에 적용하는 액상형 규산질계 침투성 방수재의 성능평가에 관한 연구 (A Study on a Performance evaluation for Quality Liguid Siliceous of waterproof agent using on the concrete Structure)

  • 강효진;권시원;오상근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.184-187
    • /
    • 2004
  • There are many factors that generate the early deterioration of the concrete structure. As the one of the representative factors, we can think an invasion of the water, air and so on. The water and air invade in inside void along the capillarity and they become the cause that the durability like corrosion of layer department due to freezing and thawing, inside steel frame corrosion, and so on blacks. Therefore with covering permeability covering waterproofing material of fluid condition in outer wall, intercepting the deterioration factor due to the infiltration of water from outside and for salt damage of concrete layer department, freezing damage and neutralization, it needs to improve durability of structure. This study separately examined physical and chemical specific of quality liguid siliceous of waterproofing material. Therefore as this applys the construction site, it improves the durability of concrete structure. Further this presents the application plan from the construction market against the new material.

  • PDF

액상형 규산질계 침투성 방수재의 성능평가에 관한 연구 (A Study on a Performance evaluation for Quality Liguid Siliceous of Waterproof agent)

  • 강효진;권시원;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문 발표회
    • /
    • pp.63-67
    • /
    • 2003
  • There are many factors that generate the early deterioration of the concrete structure. As the one of the representative factors, we can think an invasion of the water, air and so on. The water and air invade in inside void along the capillarity and they become the cause that the durability like corrosion of layer department due to freezing and thawing, inside steel frame corrosion, and so on blacks. Therefore with covering permeability covering waterproofing material of fluid condition in outer wall, intercepting the deterioration factor due to the infiltration of water from outside and for salt damage of concrete layer department, freezing damage and neutralization, it needs, to improve durability of structure. This study separately examined physical and chemical specific of quality liguid siliceous of waterproofing material. Therefore as this applys the construction site, it improves the durability of concrete structure. Further this presents the application plan from the construction market against the new material.

  • PDF

액상형 규산질계 침투성 방수재의 성능평가에 관한 연구 (A Study on a Performance evaluation for Quality Liguid Siliceous of waterproof agent)

  • 강효진;권시원;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문발표회
    • /
    • pp.63-67
    • /
    • 2003
  • There are many factors that generate the early deterioration of the concrete structure. As the one of the representative factors, we can think an invasion of the water, air and so on. The water and air invade in inside void along the capillarity and they become the cause that the durability like corrosion of layer department due to freezing and thawing, inside steel frame corrosion, and so on blacks. Therefore with covering permeability covering waterproofing material of fluid condition in outer wall, intercepting the deterioration factor due to the infiltration of water from outside and for salt damage of concrete layer department, freezing damage and neutralization, it needs to improve durability of structure. This study separately examined physical and chemical specific of quality liquid siliceous of waterproofing material. Therefore as this applys the construction site, it improves the durability of concrete structure. Further this presents the application plan from the construction market against the new material.

  • PDF

고성능유동화제가 콘크리트의 공학적 특성에 미치는 영향 (I) (A Study on the Effects of Superplasticizers on the Engineering Preperties of Plain Concrete (I))

  • 박승범;이보성
    • 한국농공학회지
    • /
    • 제26권3호
    • /
    • pp.68-80
    • /
    • 1984
  • This study was attempted in order to investigate the effects of superplasticizers on fresh and hardened concrete. The experimental program included tests on the slump and slump loss, bleeding, time of set, air content, the compacting, factor Vee Dee, compressive strength, tensile and flexural strength, permeability, shrinkage and freege-thaw durability. The major conclusions that can be drawn on the study are as follows. 1. Superplasticizers were observed to have an appreciable fluidifying action in fresh concrete so that tinder appropriate conditions, they either considerably improved its workability or permitted a water reduction of at least 8-12% to be made while maintaining normal workability. 2. The bleeding ratios of base and S,P. Concrete were much lower than those of the conventional concrete. Differences between the base and S.P. Concrete were insignifician. 3. The setting time was the longest for conventionla concrete, followed by S.P. concrete and base concrete in thatorder. And AE water reduction admixtures showed an appreciable influence on the setting and hardening characteristics of concrete and prolonged the stiffening times. 4. The high initial slump values of S.P. concrete generally decreased rapidly with increased standing time. CF values showed increasing tendencies with the increase of S.P. content, and excessive addition of S.P. caused the segregation of fresh concrete, resulting in its rejection. 5. Though there was a slight increase in strength, no significant differences are observed between base and S.P. concrete in terms of the compressive, tensile and flexural strength. 6. The permeability of S.P. concrete was significantly less than that of the conventional concrete, and the shrinkage of S.P. concrete was considerably smaller than that of the conventional concrete, but there were no significant differences between base and S.P. concrete. 7. Compared to base concrete, S.P. concrete without entrained air tended to slightly increase freeze-thaw durability, and S.P. concrete with an appropriate entrained air gave satisfactory resistance to freezing and thawing.

  • PDF

화상분석법을 통한 경화 콘크리트의 미세 공극 구조 분석 (Analysis of Air Voids System Using Image Analysis Technique in Hardened Concrete)

  • 윤경구;정원경;전인구;이봉학
    • 콘크리트학회논문집
    • /
    • 제16권6호
    • /
    • pp.741-750
    • /
    • 2004
  • 경화 후 콘크리트 내부 공극은 간격계수로 특정지어질 수 있으며 이는 동결융해 저항성, 표면박리 저항성 그리고 투수성과 같은 콘크리트의 내구성에 매우 중요한 영향을 주게 된다. ASTM에 규정되어 있는 리니어트래버스방법과 수정포인트카운트 방법은 이러한 콘크리트의 공극 구조를 분석하기 위하여 사용되어져 왔다. 그러나, 이들 방법은 많은 시간과 노력을 필요로 하며 반복측정성 또한 신뢰성이 높지 못한 단점을 가지고 있다. 화상분석방법은 미세현미경, 디지털카메라 그리고 컴퓨터 프로그램을 이용하여 경화 후 콘크리트의 내부 공극 구조에 활용되어 질 수 있는 방법이다. 본 연구의 목적은 화상분석법의 개발과 기존의 ASTM방법에 의한 결과를 비교 분석하여 사용성을 확인하고자 하였다. 이를 위해 공기량과 공극분포, 공극 구조 및 간격계수와 연관성을 분석하였다. 실험적 변수는 공기연행제의 첨가률에 따른 공기량 변화와 시편 깊이에 따른 공극 구조를 비교 분석하였다. 실험결과 화상분석기법을 사용할 경우에도 간격계수의 산출이 가능하였으며 또한, 공기량, 공극 크기분포, 공극 구조 등을 분석할 수 있었다.

스커트의 열특성에 관한 연구 (A Study on the Thermal Properties of Skirts)

  • 최혜선
    • 한국의류학회지
    • /
    • 제13권4호
    • /
    • pp.388-399
    • /
    • 1989
  • The purpose of this study was to investigate the effects of garment design, fabric type and the presence of lining on the thermal insulation value $(I_{cle}\;and\;I{cl})$ and clothing area factor $(f_{cl})$ of skirts. A standing, electrically heated thermal maninkin was used to measure the insultation value of eighty skirts-five skirt styles with eight different fabrics, with and without lining. The air temperature of the chamber was set at $22.2^{\circ}C{\pm}0.5^{\circ}C$ , air velocity was limited to less than 0.1 m/s, and relative humidity was approximately $50\%$. The results are as follows: 1) The Ic, values of gathered skirt and flared skirt, which had high $f_{cl}$ values, were significantly higher than those of other skirts, though the highest $I_{cle}$ value among five styles wer pegged skirt. 2) Insulation values of various skirts were more relevant with physical properties such as thickness, air permeability, and thermal transmission of the materials rather than fiber content. 3) The addition of lining made significant difference in the insulation values of skirts and the differences of gathered and flared skirt were significantly higher than those of othere types of skirts.

  • PDF