• 제목/요약/키워드: Air mass category

검색결과 8건 처리시간 0.021초

기단 역궤적분석에 의한 경주시 대기오염물질의 농도 변화 (Variation of Concentration of Air Pollutants with Air Mass Back-Trajectory Analysis in Gyeongju)

  • 김경원;방소영;정종현
    • 한국대기환경학회지
    • /
    • 제24권2호
    • /
    • pp.162-175
    • /
    • 2008
  • Gyeongju, which was the central city of the ancient civilization at Silla Kingdom, has various kinds of stone cultural properties. It is significantly important to preserve historical sources of Korea. However, recent air quality data measured in Gyeongju did not show good air quality level. In order to investigate variation of the concentration of the air pollutants with meteorological condition, an air quality monitoring and an aerosol sampling were conducted during the intensive monitoring period in Gyeongju. Impacts of the meteorological factors on the air pollutants were also analyzed based on the air mass pathway categories using HYSPLIT model and the local wind patterns using MM5 model. The prevailing air mass pathways were classified into four categories as following; category I affected by easterly marine aerosols, category II affected by northwesterly continental aerosols, category III affected by southwesterly continental aerosols, and category IV affected by northerly continental aerosols. The concentrations of the air quality standards were relatively lower during the fall intensive monitoring period. At that time, the easterly marine air mass pattern was dominated. The seasonal average mass concentration of $PM_{10,Opt}$, which optically measured at the monitoring site, was the highest value of $77.6{\pm}28.3\;{\mu}g\;m^{-3}$ during the spring intensive monitoring period but the lowest value of $20.1{\pm}5.3\;{\mu}g\;m^{-3}$ during the fall intensive monitoring period. The concentrations of $SO_2$ and CO were relatively higher when the air mass came from the northwestern continent or the northern continent. The concentrations of ${SO_4}^{2-}$ and ${NO_3}^-$ increased under the northwesterly continental condition. It was estimated that the acidic aerosols were dominated in the atmosphere of Gyeongju when the air mass came from the continental regions.

항공관측자료를 이용한 2006년 멕시코시티 주변 기류의 물리-화학적 성질에 따른 오존의 광화학적 특성 연구 (A Study of Ozone Photochemistry in Different Physico-chemical Properties of Air Masses around the Mexico City Metropolitan Area (MCMA) Using Aircraft Observations in 2006)

  • 송상근;손장호;김유근
    • 한국대기환경학회지
    • /
    • 제26권2호
    • /
    • pp.118-136
    • /
    • 2010
  • Photochemical characteristics of ozone ($O_3$) and its precursors such as $O_3$ budget and $O_3-NO_x$-VOC sensitivity were analyzed in different physico-chemical properties of air masses around the Mexico City Metropolitan Area (MCMA) using aircraft observations during March 2006. The physico-chemical properties of air masses were categorized into 5 groups: boundary layer (BL), biomass burning (BB), free tropospheric continent (FTCO) and marine (FTMA), and Tula industrial complex (TIC). Results from the $O_3$ budget analysis indicated that $O_3$ production for BL, FTCO, and FTMA (for BB and TIC) was mainly controlled by a photochemical production pathway, a reaction of NO with $HO_2$ (with $RO_2$), while the main pathway of photochemical $O_3$ destruction for BL, FTCO, and FTMA (for BB and TIC) was a reaction of $HO_2$ with $O_3$ (of $H_2$ with $O^1$(D)). In addition, most of air mass categories (especially FTCO) were estimated to be $NO_x$-sensitive for $O_3$ production with lower $NO_y$, higher ratios of the other indicator species (e.g., $O_3/(NO_y-NO_x$), $H_2O_2/HNO_3$, etc.), and the lower removal rate of radicals ($\leq$0.5) by the reaction of OH with $NO_2$ than those of the VOC-sensitive condition.

설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제26권12호
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.

설비공학회 분야의 최근 연구 동향 : 2015년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2015)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제28권6호
    • /
    • pp.256-268
    • /
    • 2016
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2015. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering were carried out in the areas of flow, heat and mass transfer, cooling and heating, and air-conditioning, the renewable energy system and the flow inside building rooms. Research issues dealing with air-conditioning machines and fire and exhausting smoke were reduced. CFD seems to be spreading to more research areas. (2) Research works on heat transfer area were carried out in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the economic analysis of GHG emission, micro channel heat exchanger, effect of rib angle on thermal performance, the airside performance of fin-and-tube heat exchangers, theoretical analysis of a rotary heat exchanger, heat exchanger in a cryogenic environment, the performance of a cross-flow-type, indirect evaporative cooler made of paper/plastic film. In the area of pool boiling and condensing, the bubble jet loop heat pipe was studied. In the area of industrial heat exchangers, researches were performed on fin-tube heat exchanger, KSTAR PFC and vacuum vessel at baking phase, the performance of small-sized dehumidification rotor, design of gas-injection port of an asymmetric scroll compressor, effect of slot discharge-angle change on exhaust efficiency of range hood system with air curtain. (3) In the field of refrigeration, various studies were carried in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, a cold-climate heat pump system, $CO_2$ cascade systems, ejector cycles and a PCM-based continuous heating system were investigated. In the alternative refrigeration/energy system category, a polymer adsorption heat pump, an alcohol absorption heat pump and a desiccant-based hybrid refrigeration system were investigated. In the system control category, turbo-refrigerator capacity controls and an absorption chiller fault diagnostics were investigated. (4) In building mechanical system research fields, eighteen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the user and location awareness technology applied dimming lighting control system, the lighting performance evaluation for light-shelves, the improvement evaluation of air quality through analysis of ventilation efficiency and the evaluation of airtightness of sliding and LS window systems. The subjects of building energy were worked on the energy saving estimation of existing buildings, the developing model to predict heating energy usage in domestic city area and the performance evaluation of cooling applied with economizer control. The studies were also performed related to the experimental measurement of weight variation and thermal conductivity in polyurethane foam, the development of flame spread prevention system for sandwich panels, the utilization of heat from waste-incineration facility in large-scale horticultural facilities.

설비공학 분야의 최근 연구 동향 : 2016년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2016)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제29권6호
    • /
    • pp.327-340
    • /
    • 2017
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2016. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of flow, heat and mass transfer, the reduction of pollutant exhaust gas, cooling and heating, the renewable energy system and the flow around buildings. CFD schemes were used more for all research areas. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results of the long-term performance variation of the plate-type enthalpy exchange element made of paper, design optimization of an extruded-type cooling structure for reducing the weight of LED street lights, and hot plate welding of thermoplastic elastomer packing. In the area of pool boiling and condensing, the heat transfer characteristics of a finned-tube heat exchanger in a PCM (phase change material) thermal energy storage system, influence of flow boiling heat transfer on fouling phenomenon in nanofluids, and PCM at the simultaneous charging and discharging condition were studied. In the area of industrial heat exchangers, one-dimensional flow network model and porous-media model, and R245fa in a plate-shell heat exchanger were studied. (3) Various studies were published in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, subjects include mobile cold storage heat exchanger, compressor reliability, indirect refrigeration system with $CO_2$ as secondary fluid, heat pump for fuel-cell vehicle, heat recovery from hybrid drier and heat exchangers with two-port and flat tubes. In the alternative refrigeration/energy system category, subjects include membrane module for dehumidification refrigeration, desiccant-assisted low-temperature drying, regenerative evaporative cooler and ejector-assisted multi-stage evaporation. In the system control category, subjects include multi-refrigeration system control, emergency cooling of data center and variable-speed compressor control. (4) In building mechanical system research fields, fifteenth studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, renewable energies, etc. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which could be help for improving the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the analyses of indoor thermal environments controlled by portable cooler, the effects of outdoor wind pressure in airflow at high-rise buildings, window air tightness related to the filling piece shapes, stack effect in core type's office building and the development of a movable drawer-type light shelf with adjustable depth of the reflector. The subjects of building energy were worked on the energy consumption analysis in office building, the prediction of exit air temperature of horizontal geothermal heat exchanger, LS-SVM based modeling of hot water supply load for district heating system, the energy saving effect of ERV system using night purge control method and the effect of strengthened insulation level to the building heating and cooling load.

대규모 택지개발지구내 신교통시스템 도입효과 분석 (Analysis of New Transit System Effect in Large Scale Land Development Projects)

  • 김태균;장인석;이영훈
    • 토지주택연구
    • /
    • 제1권1호
    • /
    • pp.113-124
    • /
    • 2010
  • 이 연구는 신도시 및 대규모 택지개발 지구내 신교통 시스템을 도입함으로써 예상되어지는 효과를 분석하고, 이에 대한 적용 가이드라인을 제시한 것이다. 이를 위해 각 신교통 시스템 및 유형별 복합카테고리를 설정하여 지역적 특성을 반영하고자 하였으며, 신교통 시스템 도입이 기존의 대중교통체계 및 간선도로를 대체함으로써 발생되어지는 사회적 편익을 산출하였다. 분석결과, 신교통시스템 도입은 교통혼잡비용 감소, 탄소저감, 각 지자체의 친환경적 정책 입안에 뚜렷하게 기여할 수 있는 것으로 밝혀졌다. 그러나 신교통시스템의 이러한 장점에도 불구하고 이 연구에서는 신교통시스템을 도입하고자 하는 지자체에서는 무엇보다도 지역여건에 부합하는 신교통 시스템 유형을 선별하는 것이 중요함을 강조하고 있다. 특히 지자체의 무분별한 신교통시스템 도입은 대규모 택지개발사업에 의한 분양가 상승으로 이어질 가능성이 매우 높기 때문이다.

자동차 대기오염물질 산정 방법론 설정에 관한 비교 연구 (강남구의 실시간 교통량 자료를 이용하여) (Comparative Study on the Methodology of Motor Vehicle Emission Calculation by Using Real-Time Traffic Volume in the Kangnam-Gu)

  • 박성규;김신도;이영인
    • 대한교통학회지
    • /
    • 제19권4호
    • /
    • pp.35-47
    • /
    • 2001
  • 대도시에서 자동차는 1차 대기오염물질의 가장 큰 발생원 중의 하나이기 때문에 자동차 오염물질을 감소시키기 위한 수많은 저감 대책이 추진되고 있다. 이러한 저감 대책 연구의 대표적인 특징은 대기오염물질의 배출목록 자료의 구축 시 오염물질의 정량성과 공간적인 분포성에 대한 것이다. 자동차 오염물질을 산정 할 때 배출목록은 활동도 통계와 차종별 배출계수 자료 등이 수집되어야 한다. 대부분의 배출목록은 개별조사나 교통모델에 의한 수동적인 자료로서 자료가 수집되는 순간부터 과거 자료가 되는 특성을 지닌다. 따라서, 최근의 추세는 도시 교통제어시스템과 자동차가 주변 환경에 미치는 영향 평가의 결합에 대한 연구가 추진되고 있다. 본 연구에서는 실시간 교통 자료를 이용한 이동오염원의 배출량을 평가하기 위한 산출 기법을 비교하여 배출량 자료구축의 방향을 설정하고자 하였다. 대상지역에서 대표적인 자동차 오염물질 중 CO의 배출량을 산정 하였다. 교통자료는 서울시 강남구 지역(강남대로-영동대로와 역삼로-양재대로 축)에 설치되어 있는 교차로 검지기에서 수집되는 첨단교통신호시스템의 실시간 교통정보를 이용하였다. 실시간 교통정보 중 시간대별 통과 교통량과 통과속도 자료를 이용하여 시간대별 평균주행속도에 따른 배출계수와 각 도로의 길이를 고려하여 각 도로별·시간대별로 자동차에서 배출되는 CO 배출량을 산정 하였다. 또한, 기존의 차종별 일일평균주행거리에 의한 방법으로 산정한 결과와 비교하여 각각의 방법에 따른 장·단점을 파악하여 자동차 대기오염물질 배출량 산정방법론을 제시하고자 하였다.5 nm 부근과 410nm 부근의 두 부분에서 최대 파장을 나타내는 것으로 보아 410 nm 부근이 파장은 180일 이후에 형성되는 것으로 보인다. 또한 오늘날 주거형태 변화에 따라 담금용기를 항아리에 유리병으로 달리하여 보았을 때 맛과 향미, 색의 면에서 유리병에 담근 간장이 바람직하지 못한 결과를 나타내었다.), Scene editor, Spatial analyzer(Intersect, Buffering, Network analysis), VRML exporter. While, most other 3D GISes or cartographic mapping systems may be categorized into 3D visualization systems handling terrain height-field processing, 2D GIS extension modules, or 3D geometric feature generation system using orthophoto image: actually, these are eventually considered as several parts of "real 3D GIS". As well as these things, other components, especially web-based 3D GIS, are being implemented in this study: Surface/feature integration, Java/VRML linkage, Mesh/Grid problem, LOD(Level of Detail)

  • PDF

만성적 소음노출이 혈압에 미치는 영향에 대한 코호트연구 (Cohort Study for the Effect of Chronic Noise Exposure on Blood Pressure among Male Workers)

  • 차태준;김장락;강위창;양승림;이충렬;유철인;이지호
    • Journal of Preventive Medicine and Public Health
    • /
    • 제35권3호
    • /
    • pp.205-213
    • /
    • 2002
  • 장기간의 소음노출에 의한 혈압상승 또는 고혈압의 발생에 대해서는 많은 연구에도 불구하고 결과가 다양하고 논란이 많은 실정이다. 이에 연구자는 혈압에 대한 소음의 영향을 보다 정확히 평가하기 위해서 일개 사업장을 대상으로 유사 노출군의 코호트를 구성하고 9년간의 추적조사를 실시하였다. 여기서 얻은 자료를 이용하여 소음노출수준별로 혈압의 연도별 변화경향을 파악하고, 혼란변수를 통제한 상태에서도 혈압의 변화에 대해 소음노출이 영향을 미치는가를 파악하고자 하였다. 부산지역의 일개 금속제품 제조업에서 근무하고 있는 530명의 남자 근로자를 1991년부터 1999년까지 혈압을 9년간 매년 계속 추적조사 하였으며, 조사 대상자들을 근무여건과 노출되는 소음수준(noise level category, 이하 NLC로 약함)에 따라 NLC-I (사무실 근로자, 60dB(A) 미만으로 노출, 155명), NLC-II(현장 기술지원자 및 검사원, 소음에 비정기적으로 노출, 75명), NLC-III (현장근로자, 85 dB(A)이하로 노출, 귀마개 또는 귀덮개를 착용, 167명), NLC-IV (현장근로자, 85 dB(A) 초과 노출, 귀마개와 귀덮개를 동시에 착용, 133명) 의 4군으로 구분하였다. 추적기간동안 소음수준별 혈압은 분산 분석을 이용하여 비교하였고, 혼합선형모형을 이용하여 추적기간동안(1992-1999년)의 보정된 통합평균혈압을 구하고 소음노출수준별로 비교하였다. 고려된 혼란변수는 기준연도(1991년)의 연령, 흡연여부, 음주량, 운동, 고혈압 가족력, 수축기 및 확장기 혈압과 체질량지수의 변화였다. 기준연도의 혈압과 혼란변수를 보정한 상태에서 각 연도별 혈압을 비교한 결과 수축기혈압은 9년째에서, 확장기 혈압은 2년째에서 대조군과 통계적으로 유의한 차이가 있었으며, 대조군의 평균 혈압이 전반적으로 증가되었다. 추적기간동안 혼란변수를 보정한 통합수축기 혈압은 대조군인 NLC-I과의 차이가 NLC-II는 1.7 mmHg, NLC-III는 2.0 mmHg, NLC-IV는 3.8 mmHg이었고, NLC-IV의 경우 그 차이가 통계학적으로 유의하였다. 확장기혈압의 경우에는 소음노출수준별로 유의한 차이가 없었다. 본 연구는 남성근로자에서 장기간의 소음노출은 혈압의 상승에 독립적인 영향이 있음을 시사하였다.