• 제목/요약/키워드: Air insulation

검색결과 649건 처리시간 0.032초

Effect of Conductor Radius of Polyesterimide- Polyamideimide Enameled Round Wire on Insulation Breakdown Voltage and Insulation Lifetime

  • Park, Jae-Jun;Shin, Seong-Sik;Lee, Jae-Young;Han, Se-Won;Kang, Dong-Pil
    • Transactions on Electrical and Electronic Materials
    • /
    • 제16권3호
    • /
    • pp.146-150
    • /
    • 2015
  • Insulation breakdown voltage and insulation lifetime were investigated in straight lines or twisted pairs with polyesterimide-polyamideimide enameled round wires (EI/AIW ). The enamel thickness was 50 μm and the conducting copper radius was 0.50, 0.75, 1.09, and 1.50 mm, respectively. There were many air gaps in a twisted pair therefore, when voltage was applied to the twisted pair, enamel erosion took place in the air gap area because of partial discharge according to Paschen's law. Insulation breakdown voltage and insulation lifetime were highest in the sample of 0.75 mm conductor radius, which was higher than those values for 0.50 mm or 1.09 and 1.55 mm.

에어캡시트를 이용한 단열 보완형 방수공법의 단열성 평가 (Insulation Performance Evaluation for Waterproofing Materials that Uses Air Cap Sheet)

  • 마승재;이종용;최성민;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 춘계 학술논문 발표대회
    • /
    • pp.175-176
    • /
    • 2015
  • Insulation in buildings are one of the crucial factors for energy reduction, and depending on the application areas and properties of the insulation requirements, various different types of insulation materials are being developed, produced, and used. Amongst these is the aircaps often used as packing materials. Because of their porous nature, they are highly efficient in preventing heat and are consequently used overseas often as insulation materials and as part of cold water concrete insulation curing method. This paper studies the recently developed usage of aircaps in waterproofing materials and evaluated their performance as supplementary insulation materials.

  • PDF

건물 부하계산 프로그램을 이용한 외단열 시공의 에너지 절감 효과 분석 (Analysis of the Energy Saving Effect for the External Insulation Construction by Building Load Calculation Method)

  • 박재중;명제민;송두삼
    • 설비공학논문집
    • /
    • 제29권3호
    • /
    • pp.97-104
    • /
    • 2017
  • Reinforcement of insulation in apartment buildings reduces the heating and cooling energy consumption by lowering the heat transfer in the building envelope. There are differences between internal and external insulation methods in heat transmission properties. However, some building load calculation programs cannot analysis the differences between the two. This is because these programs do no account for the timelag or thermal storage effect of the wall according to the location of insulation. In this study, the heat transmission characteristics of internal and external insulation were analyzed by EnergyPlus, and heating and cooling energy demand was compared. The results showed that external insulation system had lower heating and cooling loads than internal insulation system. Also the heat transfer rate of external insulation is steadier than internal insulation. About 13.6% of heating and cooling energy demand decreased when the outdoor wall was finished with external insulation compared to the demand with internal insulation.

공기주입형 의복의 보온력 측정 및 다운재킷의 보온력과의 비교 (Comparisons of Thermal Insulations between on Air-Cell Pack Embedded Jacket and Down Jackets)

  • 김영빈;장원;김기림;김시연;백윤정;이주영
    • 한국의류학회지
    • /
    • 제39권1호
    • /
    • pp.55-62
    • /
    • 2015
  • This study investigated the thermal insulation of an air-cell pack embedded jacket and down jackets to understand the potential of air-cell pack as a filler for winter outdoor wear. A thermal manikin measured the thermal insulation of the following jackets: HD (heavy down jacket, total weight (Tw) 750g, goose down weight (Dw) 350g), LD (light down jacket, Tw 560g, Dw 140g), AF (air-cell pack embedded jacket, Tw 490g, trunk goose down in LD was replaced to air cell), F (film jacket, Tw 469g, but removed the air in the air-cell pack from the AF), and Control (control jacket, Tw 438g, removed the air-cell pack film from the F). Thermal insulations of each experimental condition were measured in a static standing posture. Total thermal insulations (IT) were 1.29clo (HD), 1.23clo (LD), 1.16clo (AF), 1.20clo (F), and 1.08clo (Control). Body regional thermal insulation was higher in the chest and back than in the abdomen and hip in all conditions. The results suggest that an economical and versatile outdoor jacket with superior thermal insulation will be feasible if the air volume is properly controlled in air-cell pack embedded jackets in consideration of regional different distribution and used in combination with film and down.

362 kV GIB 내에서 건조공기의 절연파괴 특성 (Breakdown Characteristics of Dry Air under 362 kV GIB)

  • 한기선;주형준;윤진열;유홍근
    • 한국전기전자재료학회논문지
    • /
    • 제23권10호
    • /
    • pp.804-808
    • /
    • 2010
  • In this paper, we studied the dielectric breakdown voltage characteristics by the AC withstand voltage test on using green insulation dry air instead of $SF_6$ insulation gas used in the GIB (gas insulated bus) of 362 kV GIS (gas insulated switchgear). The AC withstand voltage test applied to the standard KEPCO's 362 kV GIB with dry air insulation, and the equivalence of dielectric breakdown voltage for dry air and $SF_6$ gas were examined, and the empirical formulas of dielectric breakdown voltage for dry air were calculated, and the criterion of AC withstand voltage test for dry air insulation was derived. Using the criterion, dry air can be used instead of $SF_6$ gas for 362 kV GIB in the factory acceptance test was confirmed.

개선된 Dry Air와 SF6의 혼합비에 따른 절연파괴 특성 연구 (A Study on Characteristics of Insulation Breakdown by the Mixing Ratio of enhanced Dry Air and SF6)

  • 석정후;백종현;임동영;배성우;김기채;박원주
    • 조명전기설비학회논문지
    • /
    • 제30권3호
    • /
    • pp.86-93
    • /
    • 2016
  • It is very desirable that a mixture gas possessing excellent insulation performance is suggested for insulation on increasing high voltage. This paper proposes a $SF_6$ mixture gas based on the factors including dielectric strength, environmental impact and economic feasibility of manufacture for the insulation in eco-friendly power equipment. A suitable-$SF_6$ content was determined to improve the dielectric strength in $N_2$ and Dry Air. The examination results of the factors revealed that a $SF_6$/Dry Air mixture gas possessing the $SF_6$ content was more appropriate than a $SF_6/N_2$ mixture gas to the eco-friendly power equipment. In addition to the selection of the suitable $SF_6$ mixture gas, insulation characteristics as a function of $SF_6$ content were described from electron-detachment mechanism.

불평등전계에서의 건조공기/에폭시 복합절연물의 에폭시 두께에 따른 AC 파괴전압 분석 (Analysis of AC Breakdown Voltage accoding to epoxy thickness of Composite Insulation for Dry-Air/Epoxy under non-uniform electric field)

  • 허준;이승수;임기조;정해은;강성화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 Techno-Fair 및 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.113-114
    • /
    • 2008
  • The purpose of this paper is to analyze AC Breakdown of solid/air composite insulation depending on the thickness and the pressure of dry air for eco-friendly insulation. SF6 gas has been widely used in electric equipment as gas insulation because of high dielectric strength and arc extinguishing performance. However, because SF6 gas is one of the green house effect gases, alternative insulation such as SF6 mixture, extremely low temperature gas, vacuum, liquid and solid insulating are being investigated.

  • PDF

다층 인슐레이션의 차음성능에 대한 실험적 연구 (Experimental Research for Air-borne Noise Reduction of a Multi-layered Insulation)

  • 고강호;김영호;국형석
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.1185-1191
    • /
    • 2001
  • This paper discusses an experimental method for measuring the insertion loss (IL) performance of multi-layered insulations that are used in vehicles. Instead of two adjacent reverberation chambers which are generally used to measure the transmission loss (TL) of the large sound isolation materials, air-borne sound insulation tester was utilized to determine the IL and articulation index (AI) of standardized insulation materials. In comparison to reverberation chamber method, air-borne sound insulation tester method is more space-saving, more time-saving and more simple to the automotive acoustics. From the empirical results, it is found that the performances of insulation materials are closely connected with density of polyurethane foam, thickness of heavy layer, thickness of polyurethane foam, and application ratio to panel area.

  • PDF

JUICE CARRIER 냉동 CARGO HOLD INSULATION 설계에 대한 연구 (A Study of refrigerator cargo hold insulation design for Juice carrier ship)

  • 홍창희;이종태;박태하
    • 대한조선학회 특별논문집
    • /
    • 대한조선학회 2015년도 특별논문집
    • /
    • pp.20-27
    • /
    • 2015
  • The juice carrier is the first ship built in korea. Special refrigerator system and cargo hold insulation with stainless steel tank were equipped on cargo hold. We studied optimum design of cargo hold insulation for reducing of ship building schedule and cost including good quality with refrigerating efficiency. From this study, general and newly specified juice carrier, technical method of cargo hold insulation system, air flow with division air wall, K-value calculation have been investigated.

  • PDF

고기밀.고단열 문의 성능평가 및 기준설정에 관한 연구 (Study on the Test Methods and Performance Criterion of High Insulated Door)

  • 강재식;최경석;김경우;이승언
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.618-622
    • /
    • 2009
  • About a Structure is performance insulation include air-tight is fundamental performance for energy-saving. The Apartment house of permission balcony enlarged to increase the requirement of market of high-effective door. Since 2001 years the window and wall of insulation performance stronger frailty than keep up performance insulation that increase influence building energy generated heat loss at door. In study on presentation that high-insulation, air-tight door about experimental method and performance standard.

  • PDF