• 제목/요약/키워드: Air contents

검색결과 1,428건 처리시간 0.025초

이미지 분석에 의한 콘크리트의 공극 분포 및 공기량 분석 (Air Contents & Size Distribution of Air Voids in Concrete Using Image Analysis)

  • 권혁찬;정원경;윤경구
    • 산업기술연구
    • /
    • 제24권A호
    • /
    • pp.157-164
    • /
    • 2004
  • Air voids in hardened concrete have an important influence on concrete durability such as resistance of freezing and thawing, permeability and surface scaling resistance. Linear traverse method and point count method in ASTM standard method have been widely used to estimate the air void system in hardened concrete. However, these methods are not used at present time, because they are is exhausted much time and effort. In previous study, air voids system of concrete was estimated by spacing factor. The purpose of this study organizes image analysis method by analyzing air contents, air voids distributions by diameters, air voids system as well as spacing factors after hardened concrete. The experimental variables institute of depth of specimen(top, middle, bottom), air contents(AE contents 0, 0.01, 0.03%).

  • PDF

해양콘크리트의 연행공기량이 동결융해 저항성 및 염화물 확산특성에 미치는 영향에 관한 연구 (A Study on the Effect of Entrained Air Contents of Marine Concrete on the Properties of Freeze-Thawing Resistance and Chloride Migration)

  • 박상준;유재강;신홍철;김영진;박형근;임현칠
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.483-486
    • /
    • 2005
  • This study investigates the effect of air contents on concrete properties, compressive strength, chloride migration coefficient and freeze-thaw resistance. Chloride migration and freeze-thawing test conducted in accordance with NT-BUILD 492 and pr-EN 12390-9, respectively. As a result, compressive strength reduced with air contents increase, but chloride migration coefficient more influenced by the water-binder ratios than air contents. Air contents of hardened concrete measured half times that of fresh concrete after mixing. Also, concrete scaling decreased with air contents increased.

  • PDF

여천공단주변 대기오염이 때죽나무의 생장 특성에 미치는 영향 (Effects of Air Pollution on Physiological characteristics of Styrax japonica in Yeolchon Industrial Complex)

  • 김동근
    • 한국대기환경학회지
    • /
    • 제16권2호
    • /
    • pp.121-128
    • /
    • 2000
  • To identify the effects of air pollution on several physiological characteristics of Styrax japonica in Yeochon industrial comples soil properties photosynthetic capacity and chorophyll contents were investigated. All of these measurements were taken on Styrax japonica stand at 1. 3 and 7km from an industrial complex which is an air pollution source. In addition a Styrax japonica stand in Sang-ju city was selected as a control Each physiological measurement was in leaves of east-, west- south- and north-facing branches. The results obtained were as follows: 1) Al contents of soil in Yeochon industrial complex were higher than those of Sang-ju city a non-polluted area. higheral contents contributed to decrease in soil pH. 2) Chlorophyll contents of leaves at 1km from the industrial complex closest from the air pollution source were lower than those of 3 and 7km/ 3) Photosynthetic capacity of Styrax japonica at 1km from the air pollution source was lower than those at 3 and 7km.

  • PDF

콩의 종류와 건조 방법에 따른 비지 분말의 이화학적 특성 (Physicochemical Properties of Soybean Curd Residue Powder by Different Soybean and Drying Methods)

  • 김은지;정희남
    • 한국식생활문화학회지
    • /
    • 제38권5호
    • /
    • pp.356-364
    • /
    • 2023
  • This study compared the physicochemical properties of soybean curd residue and black soybean curd residue produced by hot air-drying and freeze-drying. Regardless of drying method, the crude protein, crude ash, crude fiber contents, pH, L, a, b color values and water soluble index were higher in soybean curd residue, whereas total polyphenol contents and antioxidant activity were higher in black soybean curd residue. Significant differences in water absorption index, oil absorption capacity and emulsion activity were observed between soybean curd residue and black soybean curd residue in freeze-drying. On the other hand, the emulsion stability was not significant difference in both hot-air drying and freeze-drying. The crude protein and crude fiber contents of soybean curd residue were not significant difference between hot-air drying and freeze-drying. Freeze-drying resulted in higher crude ash contents, pH, water absorption index, water soluble index, oil absorption capacity, emulsion activity and emulsion stability than hot-air drying. Hot-air drying have caused significantly higher water contents, water activity, total polyphenol contents and antioxidant activity in soybean curd residue than freeze-drying. In conclusion, soybean type and drying methods affect the physicochemical and quality characteristics of soybean curd residue, which could be important factors in the manufacture of processed foods.

부순모래의 입자특성이 콘크리트의 품질에 미치는 영향 (Influence of Particle Properties of Crushed Sand on the Qualities of Concrete)

  • 유승엽;손유신;이승훈;이건철;윤기원;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2005년도 춘계 학술기술논문발표대회 논문집
    • /
    • pp.89-92
    • /
    • 2005
  • This study investigates influence of particle properties of crushed sand on the duality of concrete. The test shows that an increase of fineness modulus(FM) resulted in high slump and air contents, while compressive strength decreased due to decreased adhesion with reduction of surface area. As grain shape become rounder, the slump of concrete increased, due to reduction of internal friction, and increased air contents. The reduction of adhesion by abrasion of surface declined compressive strength during the process of manufacturing crushed sand. Increase of powder contents decreased slump and it also decreased air contents due to the effect of filling air void. In addition. using powder contents increased compressive strength, but could not find any difference of bleeding and tensile strength with particle properties.

  • PDF

일시 수확한 고추의 건조방법별 품질 (Quality of Single-Harvested Red Peppers by Drying Methods)

  • 정구민;황재문
    • 한국식품과학회지
    • /
    • 제35권2호
    • /
    • pp.329-333
    • /
    • 2003
  • Fruits of 'Manita', a red pepper cultivar, and 'HL', a cultivar bred for single-harvest, cultivated by direct sowing method were harvested simultaneously. The red fruits were freeze-, sun-, indoor-, hot-air $(65^{\circ}C)$, and excessive hot-air (50% longer time) dried. For Manita. ASTA values of freeze- and indoor-dried red pepper were the highest $(153.6{\sim}168.4)$, and those of sun- and hot air-dried ones were $119.2{\sim}131.5$. Excessive hot-air drying decreased the redness by about $9{\sim}15%$ compared to normal hot-air drying. For HL, ASTA values $(150.3{\sim}171.7)$ of indoor-dried red peppers were much higher than other dried peppers. Red pigment in HL was destroyed easily during sun drying, showing values of only $49.2{\sim}69.2$. By excessive hot-air drying, the redness did not decrease, compared to normal hot-air drying. The organic acid contents of both cultivars were higher in sun- and hot-air-dried ones than freeze- and indoor-dried ones. Copsaicinoid contents of both cultivars decreased up to 22% by excessive hot-air drying compared to normal hot-air drying. Sugar contents were lower in all drying methods other than freeze drying for both cultivars.

당류계 안정화제 종류 및 혼입률 변화에 따른 회수수사용 콘크리트의 품질특성 (Qualities of Concrete Using Recycling Water with the Kinds and Contents of Saccaric Based Stabilizing Agent)

  • 김호림;김경민;우종완;한민철;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.660-663
    • /
    • 2004
  • This paper investigate the qualities variety of concrete using recycling water under various kinds and contents of saccaric based stabilizing agent(SSA). Fluidity had little changes with the kinds and contents of SSA. Air contents of concrete with recycled water only shows the tendency. With an increase in SSA contents, air content recovered. For bleeding properties, bleeding shows to be decreased with an increase in SSA contents. The use of recycled water accelerated the setting time. However, with an increase in SSA, setting time showed the similar level of plain concrete. SSA (Btype) had better performance in enhancing compressive strength owing to loss of air content. Although the use of recycled water increased the drying shrinkage compared with that of plain concrete, it tended to decrease with an increase in SSA.

  • PDF

국내산 인공경량골재를 이용한 콘크리트의 기초 특성 연구 (The Study on the Basic Properties of Concrete Containing the Domestic Artificial Lightweight Aggregate)

  • 권해원;서휘완;이지환;전우철;이재삼
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 추계 학술논문 발표대회
    • /
    • pp.32-33
    • /
    • 2013
  • This study was a result of laboratory test to confirm the porperties of concrete containing the domestic artificial lightweight aggregate. The domestic artificial lightweight aggregate is made with bottom ash which waste material in the thermal power plant. In the experimental result air contents of fresh concrete was measured lower than other artificial lightweight aggregate. This air contents is important for retaining the resistance of freezing and thawing. Therefore air contents of concrete will be considered for retaining the resistance of freezing and thawing when manufacture the concrete containing the domestic artificial aggregate.

  • PDF

A Study on the Cold Reserving Performance of PET Bottle with Shrinkage Film

  • Hong, Dae Gi;Lyu, Min Young
    • Elastomers and Composites
    • /
    • 제54권2호
    • /
    • pp.123-127
    • /
    • 2019
  • Shrink film is currently being used for plastic container lavels to avoid the use of glue. Polyethylene terephthalate (PET) bottle lavels also use shrink films in the same PET materials for easy recycling of PET bottles. An air layer is generated between the shrink film and PET bottle surface due to the bent shape of the bottle surface. This air layer can insulate external heat, as air has a relatively lower thermal conductivity. In this study, the insulation property of the air layer was examined by computer simulation. Two PET bottle models were used, one with and the other without an air layer between the PET bottle surface and lavel. The two bottle models were filled with cold liquid and exposed to room temperature for 6 h, and the temperatures of the contents were then compared. The results showed that the temperature of the contents in the bottle with the air layer was lower than that without the air layer by at least $2^{\circ}C$. This study suggests an effective lavel design of PET bottles while ensuring that the temperature of the bottle contents is maintained.