• Title/Summary/Keyword: Air content, Slump

Search Result 249, Processing Time 0.024 seconds

An Experimental Study on the Flowability and Compressive Strength of Color Concrete Mixed with Pigments (안료를 첨가한 칼라콘크리트의 유동성 및 강도에 대한 실험적 연구)

  • Choi, Jae Jin;Hwang, Eui Hwan;Moon, Dae Joong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.3A
    • /
    • pp.547-553
    • /
    • 2006
  • To know the effect of pigments on the material properties of color concrete, mortar and concrete tests were carried out by the using 5 kinds of pigment. The major component of red, yellow and black pigments was iron oxide and coloring component of blue and green pigments was copper phthalocyanine. Properties of mortar and concrete were some of difference according to adding ratio and kind of pigments. In case of using red, yellow and black pigments, setting time of concrete speeded a little and compressive strength was tendency to increase and slump or air content of concrete was same or decreased. On the other hand, in case of using green and blue pigments, compressive strength of concrete decreased largely because of the excessive air entrainment of surfactant and sump or air content of concrete increased highly. When the antifoaming agent was added to the color concrete mixed with green and blue pigments, compressive strength of concrete was improved and similar to that of concrete without pigment.

Analysis of concrete characteristic depending on chemical admixtures changing component content ratio (화학혼화제의 성분함유율 변화에 따른 콘크리트의 특성분석)

  • Ryu, Hyun-Gi
    • Journal of the Korea Institute of Building Construction
    • /
    • v.9 no.2
    • /
    • pp.85-91
    • /
    • 2009
  • W/C and unit volume, which significantly affect quality of concrete related to strength and durability, are regulated at below $185kg/m^3$ for regular concrete generally used in standard specification for constructions. The aim of this research is to develop chemical admixture and find out its potential use by identifying characteristics of admixtures added to soft concrete and hardening concrete, of which content ratio of component for each type of admixtures is subject to change in accordance with unit volume within KS' allowable range. Sodium gluconate, polyoxyethylene nonylphenyl ether, poly carboxylic copolymer in slump, which is characteristic of soft concrete, are deemed highly sensitive while there is no air entrainment except for $10\sim70%$ in WE, WR component content ratio and NP. In hardening concrete, strength in general showed higher action in compressive strength and tensile strength than in plain strength. Use of proper AE agent and AE water reducing agent at the same time is deemed to be used as chemical admixtures capable of manufacturing high-quality, high-quantity concrete.

Analysis of CO2 Emission and Economic of Rural Roads Concrete Pavement Using Air Cooled Slag Aggregate (괴재슬래그 골재를 적용한 농촌도로 포장 콘크리트의 CO2 배출량 및 경제성 분석)

  • Ahn, Byong Hwan;Kim, Hwang-Hee;Lee, Jae-Young;Cha, Sang-Sun;Lee, Goen Hee;Park, Chan-Gi
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.64 no.6
    • /
    • pp.25-34
    • /
    • 2022
  • Recently, as a study to air cooled slag, which is an industrial by-product, research is being proceed to use it as a material for concrete. In this study, the workability, air content, compressive strength, CO2 emission and economic feasibility of concrete were analyzed when air cooled slag, an industrial by-product, was applied as aggregate for rural road pavement concrete. As a result of the analysis, both the slump and air contents test results of concrete using the air cooled slag aggregate satisfied the target values, and the compressive strength was increased when the air cooled slag aggregate was used compared to when the natural aggregate was applied. On the other hand, the largest amount of CO2 emission by raw material was found in aggregate. The carbon emission of rural road pavement concrete using air cooled slag aggregate increased when the Korean LCI DB was applied compared to when natural and crushed aggregates were applied, and the emission decreased when the German LCI DB was applied. This results are due to differences in the viewpoints of industrial by-products. However, considering the recycling of waste from the environmental aspect, it is necessary to simultaneously review the CO2 emission and recycling aspects in the future. Also, the application of air cooled slag aggregate had the effect of improving the economic efficiency of rural road pavement concrete about 18.75%.

Experimental Study on Physical and Mechanical Properties of Concrete with fine Waste Glass (잔골재로 폐유리를 혼입한 콘크리트의 물리.역학적 특성에 관한 실험적 연구)

  • 박승범;조청휘;김정환
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.2
    • /
    • pp.184-191
    • /
    • 2001
  • Recently, as industrialization is rapidly growing and the standard of life is rising, the quantities of waste glasses have been hastily increased and most of them are not recycled but abandoned. It cause some problems such as the waste of natural resources and environmental pollution. Therefore, this study was conducted basic experimental research to analyze the possibilities of recycling of waste glasses(crushed waste glasses outbreaking from our country such as amber, emerald-green, flint and mixed) as fine aggregates for concrete. Test results of fresh concrete, slump and compacting factors decrease because grain shape is angular and air content increase due to involving small size particles so much in waste glasses. Also compressive, tensile and flexural strengths decrease with increase of the content of waste glasses. In conclusion, the content of waste glasses below 30% is reasonable and usage of pertinent admixture is necessary to obtain workability and air content.

Field Application of Mass Concrete Using Setting Time Difference of Super Retarding Agent for Reduction of Hydration Heat (초지연제의 응결시간차를 이용한 매스 콘크리트의 수화열 저감을 위한 현장 적용)

  • 전충근;심보길;손성운;신동안;오선교;한천구
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2004.05a
    • /
    • pp.11-14
    • /
    • 2004
  • In this paper, field application of mass concrete using setting time difference of super retarding agent is reported to reduce hydration heat of concrete placed at newly constructed apartment house in Busan. Horizontal placing lift is applied. According to test results. slump and air content meets the requirement of target values. For compressive strength, it exceeds the nominal strength ordered by the costumer. Compressive strength of concrete cured in place is achieved more than the values of nominal strength at l4days. For temperature history, maximum temperature of center at top section shows 58.5$^{\circ}C$, and at bottom section, 62.6$^{\circ}C$. According to naked eye's investigation, no hydration heat crack is observed at the surface of concrete.

  • PDF

A Fundamental Study for the Practical Use of Liquid Segregation Reducing Type Superplasticizer (액상 분리저감형 유동화제의 실용화를 위한 기초적 연구)

  • 진의영;전충근;오선교;한천구;반호영
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10a
    • /
    • pp.297-300
    • /
    • 1998
  • Usually the flowing concrete manufactured upon normal-mixed base concrete would segregate due to the less of fine particle content. In the previous studies, a new type admixture(liquid segregation reducing type superplasticizer) has been developed to prevent such segregation without modification of base concrete mixture. In this study, the tests are performed in laboratory to evaluate the admixture by analyzing the properties of flowing concrete with different water to cement ratios, so that it could be used in the fields. According to the results, this kind of superplasticizer could improve the fluidity of concrete without causing segregation. However, it seems to be more desirable of the superplasticizer could be adjusted, before it is put into the practical use, not to cause some other problems such as rapid rate of slump and air loss and retarding of setting time.

  • PDF

A Fundamental Study on the Effectiveness of Anti-freeze Agent Using Waste Coolant in Cold Weather Concreting (한중콘크리트에 있어서 폐부동액을 이용한 내한제의 효율성에 관한 기초적 연구)

  • Kim, Kyoung-Min;Won, Cheol;Kim, Gi-Cheol;Oh, Sun-Kyo;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.231-236
    • /
    • 2001
  • In this paper, tests are carried out in order to investigate the validities of anti-freeze agent, which is developed using waste coolant and existing anti-freeze agent through previous study, under various W/C and contents. According to test results, adequate dosage of developed anti-freeze agent shows positive performance in slump, air content and chloride contents in the mixture of 40% and 50% of W/C, accelerates setting time and drops the freezing temperature of concrete. Meanwhile, in the region of 30% of W/C, followings can be indicated that increasing the contents of anti-freeze agent leads to reduce fluidity, rapid setting and excessive chloride contents. Improved strength gain is shown when anti-freeze agent is used with in 8%.

  • PDF

A Study on the Remicon B/P Application and Properties of High Strength Concrete using Crushed Sand (부순모래를 사용한 고강도콘크리트의 특성 및 레미콘 B/P 적용에 관한 연구)

  • Choi, Se-Jin;Lee, Seong-Yeon;Lee, Sang-Soo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.7 no.1 s.23
    • /
    • pp.57-62
    • /
    • 2007
  • Generally, the strength of concrete depends on factors of materials, mix proportions, compaction, manufacturing methods and curing and so on. And recently, it has increased the using of crushed sand for concrete due to the exhaustion of good natural aggregate. In case of Korea, in 2004, the using ratio of crushed sand occupies about 28% of whole fine aggregate. This is an experimental study to compare and analyze the influence of W/B ratio and replacement ratio of crushed sand on the fluidity and compressive strength of high strength concrete. For this purpose, the mix proportions of concrete according to the W/B (31.5, 27.5, 23.5%) and replacement ratio of crushed sand (0, 20, 40%) was selected. And then air content, slump-flow, a-lot, compressive strength test were performed.

An Analysis on Concrete Properties with the Fineness of Waste Limestone (폐석회석의 분말도 변화에 따른 콘크리트의 특성분석)

  • Ryu, Hyun-Gi;Woo, Jong-Kwon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.7 no.1 s.23
    • /
    • pp.85-90
    • /
    • 2007
  • According as industry develops rapidly, problem of resources exhaustion and environmental pollution is appearing. Way to use construction waste that is development of new compound material and Industry product is required. Limestone powder that is Industry product is $CaCO_3$. and vicosity is promotion effect because there is no damage to hydration of cement and powder is very thin and water tightness increases. This research purposed to analyze concrete property changing limestone fineness. According as the limestone powdered replacement ratio increases, slump and unit capacity mass increased, and the air content decreased according as the replacement ratio increases. Compressive strength and tensile strength decreased according as the limestone powder replacement ratio increases.

Field Application of Setting Time Difference Method Using SRA for Reduction of Hydration Heat of Mass Concrete (매스콘크리트의 수화열저감을 위한 초지연제 응결시간차 공법의 현장 적용 -대전 가오지구 코오롱 하늘채 아파트 현장-)

  • Jeon Chung-Keun;Kim Jong;Shin Dong-An;Yoon Gi-Won;Oh Seon-Gyo;Han Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.05a
    • /
    • pp.21-24
    • /
    • 2005
  • In this paper, field application of mass concrete using setting time difference of super retarding agent is reported to reduce hydration heat of concrete placed at newly constructed apartment house in Daejeon. Horizontal placing lift is applied. According to test results,: slump and air content meets the requirement of target values. For compressive strength, it exceeds the nominal strength ordered by the costumer. For temperature history, maximum temperature of center at top section shows $25.6^{\circ}C$, and at bottom section, $35.4^{\circ}C$. According to naked eye's investigation, no hydration heat crack is observed at the surface of concrete.

  • PDF