• Title/Summary/Keyword: Air collecting

Search Result 167, Processing Time 0.021 seconds

Analysis of Potential on Measurement of SO2 and NO2 using Radiative Transfer Model and Hyperspectral Sensor (복사전달모델과 초분광센서를 이용한 아황산가스와 이산화질소의 농도 측정 가능성 분석)

  • Shin, Jung-il;Kim, Ik-Jae;Choi, Min-Jae;Lim, Seong-Ha
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.658-663
    • /
    • 2018
  • Current measuring methods for air quality are based on ground measurement networks and satellite data. New methods of collecting evidence with advanced sensors are needed because current methods have limitations in collecting evidence for the illegal emission of air pollutants at narrow areas or specific sites. This study analyzed the possibility of using an ultraviolet hyperspectral sensor to measure the concentration of nitrogen dioxide and sulfur dioxide. Two types of spectra were used: simulated spectra for gases with various concentrations using a radiative transfer model and observed spectra for each gas for a concentration. To understand the possibility of using a hyperspectral sensor, the differences between the simulated spectra and the observed spectra were analyzed, and the variation of simulated spectra were then analyzed according to the concentration. The results showed good agreement between observed spectra and simulated spectra. In addition, the absorption depth at specific wavelengths in the simulated spectra had a very strong correlation with the gas concentration. The gas concentration could be estimated using the hyperspectral sensor. In the future, validation would be needed to estimate the gas concentration through observations of various concentrations of gases using a hyperspectral sensor.

Air Sampling For Volatile Organics Using an Adsorbent (흡착제를 이용한 휘발성 유기물 채취)

  • ;L.R.Berrafato
    • Journal of Environmental Science International
    • /
    • v.1 no.1
    • /
    • pp.41-46
    • /
    • 1992
  • To perform a long-term ambient sampling study at a residential site, an air sampler was constructed to collect 24-hour integrated air samples suitable for the volatile organic compounds (VOCs) analysis. It includes an esthetically acceptance due to proximity to homes, as fell as providing the required sampling specifications. The VOCs sampler accomodates four 5/8 "stainless steel(SS) traps packed with adsorbent(Tenax) and is capable of four flow rates in the range of 5 to 50 cc/min. Sintered metal filters(10 micrometer) were directly connected to the inlet of the trap adapters. Additional specifications include: 1) constructed of organically inert materials, 2) weatherproof, 3) battery operated, 4) collecting of VOCs at a breathing zone level, and 5) quiet operation with micro diaphragm pumps wrapped by the sponge. The pump/battery system was separated from the sampling shelter. Sound levels measured for this system were below permissible sound levels (NJDEP) at a residential site. The sampler has been successfully operated at both ground level in a residential area and on the roof of a one story elementary school.hool.

  • PDF

Filterless Removal of PM2.5 Dusts by Condensational Growth (응축성장을 이용한 PM2.5 초미세먼지의 무필터 제거)

  • Pyo, Juwon;Lee, Donggeun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.4
    • /
    • pp.221-228
    • /
    • 2017
  • We proposed a novel method to remove PM2.5 dusts without HEPA filters aiming at applications in kitchens or enclosed work spaces generating PM2.5 at high concentrations. Many workers are exposed to PM2.5 owing to lack of air purification because the high replacement costs of HEPA filters make their application impractical. A key idea is to use the condensational growth of nanoparticles. Once particles grow to the size of a few micrometers, it is much easier to remove them because of their increased inertia. We developed and tested a prototype consisting of an air saturator (equipped with water spray nozzles), a condenser in which humid air was cooled down to make the particles grow, and a multi-impactor assembly for collecting the grown particles.

Thermal Performance Variations of Glass Evacuated Tube Solar Collectors Depending on the Absorber Shape and the Incidence Angle of Solar Ray (흡수관 형상과 일사 각도에 따른 진공관형 태양열 집열기의 성능 변화)

  • Kim Yong;Seo Tae-Beom;Kang Yong-Heack
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.7
    • /
    • pp.659-668
    • /
    • 2005
  • The thermal performances of glass evacuated tube solar collectors are numerically investigated. Four different shapes of solar collectors are considered and the performances of these solar collectors are numerically investigated. Dealing with only collecting tube, the effects of not only the shape of the absorber tube but also the incidence angle of solar irradiation on the thermal performance of the collector are studied because the energy obtained by the absorber can be varied according to the incidence angle of solar radiation. However, the solar irradiation consists of the beam radiation as well as the diffuse radiation. Also, in actual system, the interference of solar irradiation and heat transfer interaction between the tubes should be considered. Therefore, this study considered these effects is carried out experimentally and numerically. The accuracy of the numerical model is verified by experiments. The result shows that the thermal performance of the absorber used a plate fin and U-tube is about $25\%$ better than those of the other models.

Vegetation Cover Characteristics for Five Soils at Chungbuk Prefecture and Tideland Soil Using Remote Sensing Technology (원격탐사(RS) 기법을 이용한 충북지역 5개 토양과 갯벌토양의 식생피복특성)

  • Park, Jong-Hwa
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.6 no.3
    • /
    • pp.9-16
    • /
    • 2003
  • In support of remote sensing applications for monitoring processes of the Earth system, research was conducted to analyze the basic spectral response related to background soil and vegetation cover characteristics in the visible and reflective infrared wavelengths. Surface samples of seven stations were examined. Five soils were from land-field and two soils from tideland areas. The vegetation cover experiment was conducted on seven soil samples with known natural moisture content (%) by weight. To study the effect of vegetation cover, spectral measurements were taken on five or six vegetation cover treatments of the seven soils with 3 replications in air dry conditions. For collecting RS base data, used spectro-radiometer that measures reflection characteristics between 300~1,100nm was used and measured the reflection of vegetation from bean leaves. The relationships were evaluated for both a general soil line and for the individual lines of five soils, under air-dried condition as well as different vegetation cover ratio, through the determination of the line parameters. As vegetation cover ratio in bean leaves increases, features of soil reflectance decrease and those of plant reflectance become more and more apparent. In proportion to vegetation cover rate, near-infrared reflectance increased and visible reflectance decreased. Analysis results are compared to commonly used vegetation indices(RVI and NDVI ).

Assessment of Reliability when Using Diagnostic Binary Ratios of Polycyclic Aromatic Hydrocarbons in Ambient Air PM10

  • Pongpiachan, Siwatt
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.18
    • /
    • pp.8605-8611
    • /
    • 2016
  • The reliability of using diagnostic binary ratios of particulate carcinogenic polycyclic aromatic hydrocarbons (PAHs) as chemical tracers for source characterisation was assessed by collecting PM10 samples from various air quality observatory sites in Thailand. The major objectives of this research were to evaluate the effects of day and night on the alterations of six different PAH diagnostic binary ratios: An/(An + Phe), Fluo/(Fluo + Pyr), B[a]A/(B[a]A + Chry), B[a]P/(B[a]P + B[e]P), Ind/(Ind + B[g,h,i]P), and B[k]F/Ind, and to investigate the impacts of site-specific conditions on the alterations of PAH diagnostic binary ratios by applying the concept of the coefficient of divergence (COD). No significant differences between day and night were found for any of the diagnostic binary ratios of PAHs, which indicates that the photodecomposition process is of minor importance in terms of PAH reduction. Interestingly, comparatively high values of COD for An/(An + Phe) in PM10 collected from sites with heavy traffic and in residential zones underline the influence of heterogeneous reactions triggered by oxidising gaseous species from vehicular exhausts. Therefore, special attention must be paid when interpreting the data of these diagnostic binary ratios, particularly for cases of low-molecular-weight PAHs.

The Study on the Atmospheric Corrosion Tests of Materials in Northeast Asia (동북 아시아 지역에서의 대기중 재료부식 시험에 관한 연구)

  • 김선태;임봉빈
    • Journal of Environmental Science International
    • /
    • v.7 no.3
    • /
    • pp.361-368
    • /
    • 1998
  • The structure such as building and cultural properties was composed of various materials like wood, metal and stone that have been utilized and exposed to air, wind and rain far a long time. However, because of their special characteristics as structure, collecting of samples that may involve their destruction cannot be permitted, ever for material analysis. Therefore, h order to study the Influence of atmospheric pollution on structure, atmospheric corrosion tests were achieved by making use of materials(bronze. ancient copper, copper, steel and marble) in field exposure tests. Atmospheric exposure sites are selected from places which are characterized by urban, rural, Industrial and marine enoronments In Northeast Asia. According to the results of atmospheric corrosion tests: The corrosion rates of Industrial states In china were more serious than other sampling sites. In the correlation of meteorological factors. wet hours was defiled as Intogeacted hours under that atmospheric temperature is above $0^{\circ}C$ and relative humidity in above 80% that has a great influence on corrosion tests of materials in case of a short time. The relative humidity was above about 75% that resulted in great increase of corrosion rates. In the esimation of corrosion rates between materials, corrosion rates of steel was about thirty times and decuple larger than that of other materials excluding marble in unshelterd exposure and In sheltered exposure.

  • PDF

Prototype Development of GPS Jammer Localization System for GPS based Air Navigation System (GPS기반 항공 항법 장비를 위한 전파위협원 위치추적 시작품 개발)

  • Kang, Jae Min;Lim, Deok Won;Chun, Sebum;Heo, Moon Beom;Yeom, Chan Hong
    • Journal of Aerospace System Engineering
    • /
    • v.8 no.2
    • /
    • pp.40-48
    • /
    • 2014
  • In this paper, a prototype of GPS jammer localization system for precise landing is developed. The jammer localization system consists of the four jamming signal receivers for collecting RF signal, one central tracking station for estimating jammer position, and one monitoring station for displaying estimated position on the map. In order to estimate jammer location TDOA and AOA algorithm are introduced, and the function and design parameters of the developed prototype are proposed. CW, DSSS, Swept CW jamming signals were generated and used. From the results, it can be confirmed that developed system meets the performance goal.

Selecting of the Energy Performance Diagnosis Items through the Sensitivity Analysis of Existing Buildings (민감도 분석을 통한 기존건축물의 에너지성능 진단항목 선별)

  • Kong, Dong-Seok;Chang, Yong-Sung;Huh, Jung-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.7
    • /
    • pp.354-361
    • /
    • 2015
  • The building energy audit is an important process when collecting basic information for improving the energy performance of existing buildings. Audit parameters should be associated with the energy performance of the building. Such audit parameters will vary according to an individual building's characteristics and energy consumption patterns, but most building energy audits are performed in the same way. The sensitivity analysis (SA) is a statistical method to quantify the correlation between inputs and outputs that can determine which input is influential to which output. Therefore, an SA can identify influential parameters when applied to building energy analysis. In this paper, we adopted the Morris method to identify building energy audit parameters and performed a Monte Carlo simulation for uncertainty analysis. As a result, this method was able to identify an influential parameter for building energy audits and reduce uncertainty in energy consumption in buildings.

Capacity Modulation of a Heat Pump System by Changing the Composition of Refrigerant Mixtures (혼합냉매의 성분비 조절을 통한 열펌프의 용량조절)

  • 김민성;김민수;김용찬
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.3
    • /
    • pp.258-266
    • /
    • 2000
  • Experimental investigation and cycle simulation of a capacity modulation of a heat pump system using a hydrofluorocarbon (HFC) refrigerant mixture, R32/134a as an alternative to R22, have been done. In the cycle simulation, the refrigeration system was operated by assigning the temperatures of the external heat transfer fluids with the heat exchangers generalized by an average effective temperature difference. Heating capacity, cooling capacity, and coefficient of performance (COP) of the system were investigated at several operating conditions. Experimental apparatus which had a refrigeration part and a composition changing part was built, and the performance of the heat pump system filled with R32/134a mixture was investigated. A gas-liquid separator was used in the experiment to change the composition by collecting the vapor and the liquid Phase separately, The mass fraction of the charged refrigerant in the heat pump system was 40/60 and 70/30 by weight percentage. The composition of the refrigerant with initial composition of 40/60 varied from 29/71 to 41/59 in the refrigeration cycle. For the refrigerant with initial composition of 70/30, the composition varied from 65/35 to 75/25.

  • PDF