• 제목/요약/키워드: Air change rate

검색결과 765건 처리시간 0.037초

폐김치냉장고에서의 HFC-134a 탈루배출 특성에 대한 연구 (Fugitive Emission Characteristics of HFC-134a from Waste Kimchi Refrigerator)

  • 김의건;김승도;이영표
    • 한국대기환경학회지
    • /
    • 제30권1호
    • /
    • pp.59-67
    • /
    • 2014
  • In 1995 Kimchi refrigerator was developed at first, and has used HFC-134a as refrigerant. Kimchi refrigerator has been made 1,044,694 on the basis of 2010, disposed about 160,000 per year. Although mobile air conditioning, commercial refrigerator, general refrigerator is regarded as a major source of HFC-134a, little information is available for its emission characteristics of HFC-134a. This paper addresses the fugitive emission factors of Kimchi refrigerator at use-phase and disposal-phase. The residual quantities of Korean-made fifty three waste Kimchi refrigerators were weighed using a commercial recover of refrigerants to determine the emission factors at the disposal-phase. On the other hand, the emission factors at use-phase were estimated from the residual quantities and operating times. The average residual rate of forty three scarp Kimchi refrigerators is determined to be $74.6{\pm}5.2%$. The emission factor at the use-phase is estimated to be $3.5{\pm}0.8%/yr$ as a result of using average age of 11.7 years and the average residual rate determined here. The emission factor at the disposal-phase is determined to be 31.3% after adopting 58% of the recycling rate of refrigerant reported by Recycling Center. We estimate 3.1 g/yr for the average emission quantity of HFC-134a per operating refrigerator, while 22.5 g for that per waste Kimchi refrigerator. Since the chemical compositions of refrigerant of waste Kimchi refrigerator were the same as those of new refrigerant, it is expected that the HFC-134a recovered from waste Kimchi refrigerator can be reused for refrigerant.

해양구조물용 고압 컨트롤 밸브 수치해석 (A Numerical Analysis on High Pressure Control Valve for Offshore)

  • 이중섭;장성철;정휘원;남태희
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1195-1200
    • /
    • 2008
  • This study have goal with conceptual design for Offshore Structures of high pressure control valve for localization. Ball valve for development accomplished with flow analysis based on provision of ANSI B16.34, ANSI B16.10, ANSI B16.25 In order to localize the Offshore Structures high pressure control valve. Numerical simulation using CFD(Computational Fluid Dynamic) in order to predict a mass flow rate and a flow coefficient form flow dynamic point of view. The working fluid assumed the glycerin($C_3H_8O_3$). The valve inlet and outlet setup a pressure boundary condition. The outlet pressure was fixed by atmospheric pressure and calculated until increasing 1bar to 10bar. CFD analysis used STAR-CCM+ which is commercial code and Governing equations were calculated by moving mesh which is rotated 90 degrees when ball valve operated opening and closing in 1 degree interval. The result shows change of mass flow rate according to opening and closing angle of valve. Flow decrease observed open valve that equal percentage flow paten which is general inclination of ball valve. Relation with flow and flow coefficient can not be proportional according to inlet pressure when compare with mass flow rate. Because flow coefficient have influence in flow and pressure difference. Namely, flow can be change even if it has same Cv value. The structural analysis used ANSYS which is a commercial code. Stress analysis result of internal pressure in valve showed lower than yield strength. This is expect to need more detail design and verification for stem and seat structure.

  • PDF

한국형 체감온도지수 개발연구(III) - 체감온도지수 개발을 위한 본실험 - (A Study of the Development of a Korea Wind Chill Temperature Index(III) - Principal Experiment for Development of the Korea Wind Chill Temperature Index -)

  • 박종길;정우식;김병수;윤숙희;이종태;김은별;박길운;김석철;정경석
    • 한국환경과학회지
    • /
    • 제17권10호
    • /
    • pp.1093-1109
    • /
    • 2008
  • This paper aims to provide a fundamental basis for the improvement and verification of existing wind chill temperature index through the observation of skin temperature change of human body with air temperature and wind speed. For this, we control air temperature $5^{\circ}C$ interval from $0^{\circ}C$ to $-20^{\circ}C$ and classify wind speed by 0, 2, 6 and 8 m $s^{-1}$ respectively. The results are as follows; At each combination of air temperature and wind speed, the reduction rate of the mean skin temperature are different. When our body is exposed to the atmosphere, the mean skin temperature decreases at an exponential rate. The duration of the steady state is more than one hour, while it decreases with strong wind speed. Among 4 sites on a face, the skin temperature of forehead is the highest, followed by one of chin, left cheek, right cheek in orders. Especially, since the skin temperature of right cheek is the lowest, we think that it is suitable to use the data set of the right cheek skin temperature for the development of a Korea wind chill temperature index as a worst case.

공동주택 단지의 실내 공기질 향상을 위한 수치 해석적 연구 (A numerical Study for Improvement of Indoor Air Quality of Apartment House)

  • 신미수;김혜숙;홍지은;장동순
    • 대한환경공학회지
    • /
    • 제31권7호
    • /
    • pp.521-530
    • /
    • 2009
  • 본 연구에서는 대전의 대규모 공동주택단지의 하나인 대덕테크노 밸리의 계절별 주풍향 및 풍속, 건물배치, 환기구 위치 등 다양한 외부 유동 변수에 따른 실내 환기 특성을 수치 해석적 방법을 활용하여 연구함으로써 실내 공기질 향상에 일조하기 위해 연구를 수행하였다. 계절별 주풍향은 여름과 겨울에 큰 차이를 나타냈는데, 여름철의 경우 주풍향은 남풍이며, 겨울철의 경우 주풍향은 10년 평균 주풍향과 동일한 북북서풍으로 나타났다. 풍향이 변화함에 따라 최대 압력차가 나타나는 단지도 변화하였으며 그에 따라 환기에도 차이를 나타냈다. 내부 환기량은 환기 우수지역의 경우는 자연환기만으로 기준치인 시간당 0.7ACH를 만족하였으나 환기 취약지역의 경우는 자연환기만으로는 기준치를 만족시키지 못하여 부수적으로 기계 환기를 병행해야 하는 것으로 나타났다. 이러한 외부유동 변화에 따른 내부 환기량의 연구결과를 바탕으로 향후 아파트의 배치나 환기구 위치 선정에 응용한다면 환기량 확보에 일조하여 기계환기에만 의존하지 않고 자연환기와 병행이 가능하므로 에너지 절감에 도움이 될 것으로 판단된다.

하수처리장의 포기조 최적 DO 농도 산정 및 공기송풍량 자동제어를 통한 에너지 절감 효과 도출 (A Study on Energy Saving Effect from Automatic Control of Air Flowrate and Estimation of Optimal DO Concentration in Oxic Reactor of Wastewater Treatment Plant)

  • 김민한;지승희;장정희
    • 에너지공학
    • /
    • 제23권2호
    • /
    • pp.49-56
    • /
    • 2014
  • 생물학적 하수처리공정에서 안정적인 방류수질 확보와 처리 비용을 적게 하는 것은 매우 중요하다. 하지만 유입수 유량 및 성분 농도의 변화와 미생물의 비선형적인 동특성, 기타 환경 요인에 의해서 최적의 운전 제어를 하기가 쉽지 않기 때문에, 기존의 하수처리장에서는 필요한 양 이상의 폭기 및 화학물질을 과량 주입하는 방법 등을 사용하였다. 본 연구에서는 포기조에서 미생물에 필요한 용존산 소농도를 유지함과 동시에 과폭기로 인한 전력 비용을 감소할 수 있는 최적 제어 방법을 제안하였다. 최적 제어를 위하여 실시간 미생물 호흡률 측정기(Oxygen uptake rate, OUR)을 이용하여 측정하였고, 실시간 호흡률 측정값을 바탕으로 현재 미생물에 필요한 최적 DO 농도를 제안하였으며, 이에 따라 공기송풍기가 자동제어될 수 있도록 구성하였다. 최적 제어 방법을 통하여 하수처리장 포기조의 공기 송풍량에 소요되는 전력비용을 절감할 수 있었다.

열화상 카메라를 이용한 움직임 보정 기반 호흡 수 계산 (Respiration Rate Measurement based on Motion Compensation using Infrared Camera)

  • 권준환;신증수;김정민;오경택;유선국
    • 한국멀티미디어학회논문지
    • /
    • 제21권9호
    • /
    • pp.1076-1089
    • /
    • 2018
  • Respiration is the process of moving air into and out of the lung. Respiration changes the temperature in the chamber while exchanging energy. Especially the temperature of the face. Respiration monitoring using an infrared camera measures the temperature change caused by breathing. The conventional method assumes that motion is not considered and measures respiration. These assumptions can not accurately measure the respiration rate when breathing moves. In addition, the respiration rate measurement is performed by counting the number of peaks of the breathing waveform by displaying the position of the peak in a specific window, and there is a disadvantage that the breathing rate can not be measured accurately. In this paper, we use KLT tracking and block matching to calibrate limited weak movements during breathing and extract respiration waveform. In order to increase the accuracy of the respiration rate, the position of the peak used in the breath calculation is calculated by converting from a single point to a high resolution. Through this process, the respiration signal could be extracted even in weak motion, and the respiration rate could be measured robustly even in various time windows.

Diagonal 환기 시스템에서 공기 조절기의 위치 및 크기에 따른 풍속 변화에 관한 실험적 연구 (An Experimental Study On The Change Of Air Velocity With Respect To The Location And Size Of Regulators For Diagonal Ventilation System)

  • 최종악;윤찬훈;김진
    • 터널과지하공간
    • /
    • 제19권1호
    • /
    • pp.11-18
    • /
    • 2009
  • 원자력 에너지를 이용할 때 필연적으로 방사성 폐기물이 발생된다. 방사성폐기물을 처분하기 위한 처분장은 주로 외부와 단절된 지하공간을 이용하며 방사성폐기물을 거치할 수 있는 Diagonal system을 기본으로 하며, 시스템에 발생된 열을 재기하기 위해서는 환기시설이 필수적이다. 따라서 본 연구에서는 Diagonal system에서 공기 조절기의 위치와 크기를 변화시켜 Diagonal branch로 흐르는 공기의 풍속을 측정하였다. 그 결과 Diagonal branch를 지나는 풍속은 중간에 위치한 공기 조절기의 크기에 관계없이 처음과 마지막 공기 조절기의 크기에 의해서 결정되었다. 따라서 일정한 유랑을 Diagonal branch에 주입하기 위해서는 처음과 마지막 공기 조절기를 설치하여 총 유량을 결정한 후 중간지점에 공기 조절기를 설치하여야 한다.

실내사무환경에서의 환경성담배연기(ETS)중 일부 휘발성유기화합물(VOC)에 관한 연구 (A Study on Volatile Organic Compounds(VOC) in Environmental Tobacco Smoke(ETS) at Indoor Office Environments)

  • 하권철
    • 한국환경보건학회지
    • /
    • 제27권3호
    • /
    • pp.87-98
    • /
    • 2001
  • There has been increased interest in the health effects of the Environmental Tobacco Smoke(ETS) as a confirmed human carcinogen. It has been known to be extremely difficult to make an accurate assessment of exposure to ETS since it is consisted of a variety of components and there are a number of labile chemicals. Therefore, it is necessary to obtain, to interpretate and to provide the data of quantitative exposure assessment to ETS in the field of environmental health. The purpose of this research is to evaluate the concentration of ETS using VOC in indoor office environments. The correlations and concentrations of benzene, RSP, 3-EP, nicotine that are indicators for ETS were investigate with smoking density, air change per hour(ventilation rate). Air samples were taken in smoking room(7 sites), smoking allowed office (3 sites), corridor outside smoking room(7 sites), non-smoking office (9 sites). The concentrations of benzene showed significant difference according to category of indoor office environments. The geometric mean concentration of benzene were 23.56 ${\mu}{\textrm}{m}$/㎥(range 4.80~192.90 ${\mu}{\textrm}{m}$/㎥) in smoking rooms. 6.16 ${\mu}{\textrm}{m}$/㎥ in smoking allowed offices, 1.32 ${\mu}{\textrm}{m}$/㎥ in the non-smoking offices respectively. The ratios of the concentration of benzene between outdoor air and smoking room, smoking allowed office, and non-smoking indicators concentrations, SD, and SI were 0.82(benzene and nicotine). 0.76(benzene and RSP), 0.60(benzene and SD), 0.76(benzene and SI). It is proposed that benzene is a good indicator for ETS.

  • PDF

공기도관을 사용하는 경막외강 자동탐지기구 (Epidural Space Identification Device Using Air-filled Catheter)

  • 강재환;김현식;김경아;김상태;배진호;임승운;차은종
    • 대한의용생체공학회:의공학회지
    • /
    • 제24권1호
    • /
    • pp.9-13
    • /
    • 2003
  • 경막외마취는 전신마취가 불필요하므로 널리 활용되는 마취술이다. 그러나 경막외마취 시술시 천자침이 경막외강 내에 정확하게 위치하지 않으면 각종 부작용이 발생하므로 시술자의 세심한 주의뿐만 아니라 상당한 수준의 숙달이 필요하다. 본 연구에서는 천자침이 연결된 도관 내의 압력 변화를 범용 압력센서로 연속 계측함으로써 침이 경막외강 내로 진입하는 순간을 자동탐지하는 자동화된 저항소실법을 개발하였다. 17G Tuohy 침을 황인대까지 전진시킨 후 침에 공기도관을 연결하고 공기도관에 연결된 압력센서로 압력신호를 추출하여 적절히 증폭ㆍ필터링한 후 역치감지회로가 경막외강의 진입순간을 감지하도록 전자회로를 설계ㆍ제작함으로써 저항소실법을 자동화할 수 있었다. 소량의 공기 주입으로 도관 내의 압력을 50∼100mmHg까지 녹인 후 짐을 천천히 전진시키며 압력변화신호를 10개의 녹색 발광다이오드로 연속 표시하였고 압력이 20mmHg 이하로 하강하는 순간을 경막외강 진입시점으로 인식하여 시술자를 위해 경보를 울리는 보조기기의 형태로 구현하였다. 자체 시뮤레이션을 거친 후, 경막 외마취 시술이 예정된 환자 ,30명을 대상으로 자동화된 보조기기를 사용하여 시술하였고 수동적인 저항소실법을 병행하는 임상실험을 통하여 경막외 마취시술의 성공여부를 판정하였다. 본 기기의 도움으로 첫 번째 시도에서의 마취성공률은 83%이었고 두 번째 시도에서는 모두(100%) 성공하였으며 시술 중 주입된 공기의 용적은 1ml이내로써 별는 부작용이나 합병증은 없었으므로 본 연구의 유용성이 입증되었다. 본 연구의 자동화된 저항소실법은 공기도관을 사용하였으므로 감염의 가능성도 최소화된다고 볼 수 있었으며, 따라서 편리하고 안전한 경막외마취 시술이 가능할 것으로 판단된다.

The Effect of Thermal Diffusivity on the System Efficiency of a DOTEC Cycle

  • Yoon, Jung-In;Choi, Kwang-Hwan;Kwakye-Boateng, Patricia;Son, Chang-Hyo;Kim, Hyeon-Ju;Lee, Ho-Saeng
    • 동력기계공학회지
    • /
    • 제17권5호
    • /
    • pp.58-63
    • /
    • 2013
  • In this study, the effect of deep ocean condenser inlet temperature ($T_{DOI}$), condenser inlet pressure ($P_{cond,in}$), and thermal diffusivity on system efficiency of some selected refrigerants was analyzed using HYSYS. The proposed DOTEC cycle is similar to the reheat Rankine cycle but eliminates irreversibilities by bleeding a fraction of the steam between certain stages of the turbine. The evaporator inlet mass flow rate, inlet temperature of turbine 1, turbine efficiency and inlet and outlet temperature of heat source were imposed. The working fluids considered are sorted in ascending order of their molecular weights as R717, R600a and R152a. Results indicated that a fluid with a lower boiling point temperature like R717 needs a corresponding high heat source and/or evaporator inlet pressure. Also, the response of thermal diffusivity closely follows the change in TDOI as an increase in $T_{DOI}$ increases $P_{cond,in}$ which reduces thermal diffusivity and system efficiency. Furthermore, the fluid with the nominal boiling point temperature has the highest efficiency with efficiency decreasing with an increase in TDOI.