• Title/Summary/Keyword: Air Volume Concentration

Search Result 355, Processing Time 0.019 seconds

Effective Control of Indoor Air Pollutant using VAV/BPFS (VAV/BPFS를 이용한 실내공기 오염물질의 효율적 제어)

  • 최성우
    • Journal of Environmental Science International
    • /
    • v.7 no.3
    • /
    • pp.327-334
    • /
    • 1998
  • The oil crisis of the 1970s and the rise in oil prices motivated people to implement energy conservation strategies. Buildings were fitted with additional Insulation and reduced ventilation rates. The reduction of mechanical and natural ventilation rate led to Increases In Indoor pollutant concentrations which result- ed In Increased health risks from Indoor exposure to pollutants. The variable-air-volume /bypass fitration system/VAV/BPFS) is a variation of the conventional VAV systems, The VAV/BPFS is an electronically controlled system that provides costegectlve thermal comfort and acceptable indoor air quality Under controlled conditions In a chamber, a series experiments were performed to compare the ability of a VAV/BPFS to remove Indoor aerosol concentration and to reduce energy consumption no that ability of conventional VAV system. Results show that the VAV/BPFS Increases the effective ventilation rate and removes indoor air pollutant, and maintains acceptable indoor air Quality without sacrificing energy consumption.

  • PDF

Wearable wireless respiratory monitoring system (의복착용형 무선 호흡모니터 시스템)

  • Lee, In-Kwang;Kim, Seong-Sik;Jang, Jong-Chan;Kim, Koon-Jin;Kim, Kyung-Ah;Lee, Tae-Soo;Cha, Eun-Jong
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.2
    • /
    • pp.133-142
    • /
    • 2008
  • Respiration is induced by muscular contraction of the chest and abdomen, resulting in the abdominal volume change. Thus, continuous measurement of the abdominal dimension enables to monitor breathing activity. Conductive rubber cord has been previously introduced and tested to develop wearable application for respiratory measurements. The present study implemented wireless wearable respiratory monitoring system with the conductive rubber cord in the patient's pants. Signal extraction circuitry was developed to obtain the abdominal circumference changes reflecting the lung volume variation caused by respiratory activity. Wireless transmission was followed based on the zigbee communication protocol in a size of 65mm${\times}$105mm easily put in pocket. Successful wireless monitoring of respiration was performed in that breathing frequency was accurately estimated as well as different breathing patterns were easily recognized from the abdominal signal. $CO_2$ inhalation experiment was additionally performed in purpose of quantitative estimation of tidal volume. Air mixed with $0{\sim}5%\;CO_2$was inhaled by 4 normal males and the respiratory air flow rate, abdominal dimension change, and end tidal $CO_2$ concentration were simultaneously measured in steady state. $CO_2$ inhalation increased the tidal volume in normal physiological state with a correlation coefficient of 0.90 between the tidal volume and the end tidal $CO_2$ concentration. The tidal volume estimated from the abdominal signal linearly correlated with the accurate tidal volume measured by pneumotachometer with a correlation coefficient of 0.88 with mean relative error of approximately 8%. Therefore, the tidal volume was accurately estimated by measuring the abdominal dimension change.

Minimum Detectable Radioactivity Concentration of Atmospheric Particulate Measurement System for Nuclear Test Monitoring (핵활동 감시를 위한 대기 입자 측정시스템의 최소검출 방사능 농도 결정)

  • Kim, Jong-Soo;Yoon, Suk-Chul;Shin, Jang-Soo;Kwack, Eun-Ho;Choi, Jong-Seo
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.2
    • /
    • pp.111-117
    • /
    • 1997
  • Recently, the conclusion of Comprehensive Test Ban Treaty(CTBT) is globally constructing a network system for nuclear test monitoring. The radionuclide experts of the Conference on Disarmament recommended that the detection of nuclear debris in the atmosphere was an essential factor of nuclear test monitoring and proposed the technical requirements. Based on those requirements, atmospheric radionuclide monitoring system to detect nuclear debris generated from the nuclear explosion test was composed. The system is comprised of high volume air sampler(HVAS), filter paper presser and high purity germanium detector(HPGe). Minimum detectable concentrations(MDCs) of the key nuclides requiring in CTBT monitoring strategies are determined by considering of decay time, counting time and flow rate of the high volume air sampler for the rapid explosion and the optimum measurement condition. The results were selected $10{\pm}$2h, $20{\pm}$2h and $850{\pm}50m^3$/h as parameters, respectively. The relation between the natural air-borne radionuclide concentration of $^{212}Pb$ and MDC were calculated which gave effect in the Compton continuum baseline due to those nuclides in the gamma-ray spectroscopy. These results can be used as an actually tool in the CTBT monitoring strategies.

  • PDF

A Study on The Explosion Characteristics of Flammable Gases (가연성 가스의 폭발특성에 대한 연구)

  • 오규형;김한석;이춘하
    • Journal of the Korean Society of Safety
    • /
    • v.7 no.3
    • /
    • pp.66-72
    • /
    • 1992
  • An experimental study was carried out to analyse the explosion characteristics of flammable gas-air mixtures. Used flammable gases were hydrogen, methane, acethylene, ethylene and pro-pane, explosion Pressure, explosoin pressure rising rate, and flame propagation velocity were measured experimentaly. The maximum explosion pressure and rising rate of flammmalbe gas air mixtures were appeared at the range of slightly higher concentration than the stoichiometric concentration. Initial pressure before explosion was controlled from 0.6 to 2.0kg/cm absolutly. Explosion pressure was increased with increment of the initial pressure, and the relationship between initial pressure and explosion pressure was Pe = KPi. The effect of vessel size on explosion characteristics was also analysed In this experiment. Explosion pressure was increased with in-creasing the vessel size, otherwise explosion pressure rising rate was decreased. When we locate a dummy material in vessel explosion pressure was decreased with increasing the dummy volume but exlosion pressure rising rate was increased.

  • PDF

Atmospheric Background Values at Dokdo Island, Korea (독도에서의 대기 background 농도)

  • LEE Dong-In
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.28 no.1
    • /
    • pp.80-86
    • /
    • 1995
  • To investigate the background concentration of air pollutants (SO_2,\;CO,\;NO_2,\;O_3,\;TSP)$ and the composition of atmospheric aerosols, air samplings using teflon bags and a high volume air sampler were accomplished from 7 to 8 lune 1991 (first time) and from 25 to 26 June 1992 (second time) at the top of Dokdo island, Korea. During observation periods, mean concentrations of $SO_2,\;CO'\;NO_2\;and\;O_3$ gases were 2.3 ppb, 5.57 ppm, 6 ppb and 7 ppb, respectively, and mean concentration of TSP using a high volume air sampler was $153{\mu}g/m^3$. The composition of atmospheric aerosols by SEM-EMAX analyses were mostly Na, Cl and Si, and their sizes were more than $1{\mu}m$ diameter. From the results, it is found that atmospheric background values at Dokdo island is influenced by oceanic water quality evaporated from sea surface water, and this island has to be used as a stationary observation site for meteorological and air quality data.

  • PDF

Study on NADH which is the Air Volume Sensor in the Activated Sludge Reaction Tank (활성슬러지 반응탱크의 풍량제어지표인 NADH에 관한 연구)

  • Chung, Woo-jin;Hong, Sung-min;Kim, Han-lae;Chang, Soon-woong
    • Journal of Environmental Science International
    • /
    • v.25 no.3
    • /
    • pp.439-446
    • /
    • 2016
  • Domestic sewerage treatment plant is operated by activated sludge method and its modified method by using microorganism. In most cases, a method of using microorganism is directly controlled by the operator based on individual judgment through factors of DO, pH and ORP. In addition, under aerobic condition in bioreactor, energy consumption including excessive air injection is learned to be somewhat plenty. In order to solve this problem, in most of the process, improvement of internal recycling and activated environmental factor of microorganism were researched extensively. However, as factors are changed depending on various conditions, it is not sufficient as an indicator of judgment. As such, a research on operation of bioreactor that measures metabolic change in short time by directly measuring activated condition of microorganism using NADH fluorometer is required in reality.It is considered that the method like this could supplement problem of energy consumption being occurred in the existing treatment method and operational optimization of bioreactor would be enabled by controlling optimal air volume. Therefore, in this study, in order to obtain optimal operational indicator of bioreactor, proper air volume control test was performed and through batch test and site evaluation, possibility of NADH sensor being utilized as operational control indicator of bioreactor is intended to be analyzed. In order to compare with measured value, DO, ORP that are operational control indicator of existing bioreactor were used. As MLSS concentration was increased through batch test, NADH value was increased and site evaluation also showed similar tendency to batch test. Resultantly, it could be confirmed that changing level of NADH fluorometer was a sensor that could measure bioreactor condition effectively and optimized scale of bioreactor is considered to be utilized.

Development of an Automatic PCR System Combined with Magnetic Bead-based Viral RNA Concentration and Extraction

  • MinJi Choi;Won Chang Cho;Seung Wook Chung;Daehong Kim;Il-Hoon Cho
    • Biomedical Science Letters
    • /
    • v.29 no.4
    • /
    • pp.363-370
    • /
    • 2023
  • Human respiratory viral infections such as COVID-19 are highly contagious, so continuous management of airborne viruses is essential. In particular, indoor air monitoring is necessary because the risk of infection increases in poorly ventilated indoors. However, the current method of detecting airborne viruses requires a lot of time from sample collection to confirmation of results. In this study, we proposed a system that can monitor airborne viruses in real time to solve the deficiency of the present method. Air samples were collected in liquid form through a bio sampler, in which case the virus is present in low concentrations. To detect viruses from low-concentration samples, viral RNA was concentrated and extracted using silica-magnetic beads. RNA binds to silica under certain conditions, and by repeating this binding reaction, bulk samples collected from the air can be concentrated. After concentration and extraction, viral RNA is specifically detected through real-time qPCR (quantitative polymerase chain reaction). In addition, based on liquid handling technology, we have developed an automatic machine that automatically performs the entire testing process and can be easily used even by non-experts. To evaluate the system, we performed air sample collection and automated testing using bacteriophage MS2 as a model virus. As a result, the air-collected samples concentrated by 45 times then initial volume, and the detection sensitivity of PCR also confirmed a corresponding improvement.

Trace Metals of Ambient TSP in Daegu Area (대구지역 총 부유분진중 중금속)

  • 이찬형
    • Journal of Environmental Health Sciences
    • /
    • v.29 no.1
    • /
    • pp.67-73
    • /
    • 2003
  • This study was carried out to characterize the behavior and sources of particulate trace metal in Daegu city. TSP (Total Suspended Particulate matter) was collected by filters on High Volume Air Sampler from the four areal (reference, residential, commercial, industrial area). The moult were analyzed by AAS after preliminary treatment. The average centration trend of trace metals contained in TSP was shown as follows : Fe > Cu > Pb > Mn > Ni > Cr > Cd. The trace metals showed the highest concentration in the industrial area. This study showed the seasonal variation of trace metals. Fe and Mn showed high concentration in spring, whereas Cr, Ni, Cd and Pb showed high concentration in winter. Also this study showed the regional variation of trace metals. The order of the average concentration of trace metals was : industrial > commercial > residential > reference area. Using Mn as a reference element, the enrichment factor analysis were used for identifying the trace element contributors. The enrichment factors of Cr, Fe < 10 were considered to have a significant dust and soil source and termed nonenriched. Pb, Cd, Cu >>10 were enriched and had a significant fraction which was contributed by anthropogenic sources.

Concentration Characteristics of Elemental and Organic Carbons During Asian Dust Episode and Non-Episode (황사시와 비황사시 대기 입자상 탄소성분의 농도 특성)

  • Hwang, Kyung-Chul;Cho, Ki-Chul;Shin, Eun-Sang
    • Journal of environmental and Sanitary engineering
    • /
    • v.24 no.4
    • /
    • pp.102-111
    • /
    • 2009
  • In this study, Particulate carbon were determined from 1990 to 1995. The annual variation were investigated. The sampling was carried out using high volume air sampler. Average concentrations of EC and OC during the yellow sand event were $25.70{\mu}g/m^3$ and $13.91{\mu}g/m^3$, respectively, $22.10{\mu}g/m^3$ and $10.33{\mu}g/m^3$ during the non-yellow sand event. TC concentration of TSP were 10.7% during the yellow sand event and 20.6% during the non-yellow sand event. Average concentration rate of EC and OC of TC were 64.9% and 35.1%, respectively during the yellow sand event, 67.6% and 32.4% during the non-yellow sand event.

A Study on Polynucler Aromatic Hydrocarbons in Atmospheric Particulate Matters -Based on the data aquired in Heukseok-Dong, Seoul- (부유분진중 다환방향족 탄화수소에 관한 연구 - 서울 흑석동 지역을 중심으로)

  • 손동헌;이규식;허문영
    • YAKHAK HOEJI
    • /
    • v.30 no.6
    • /
    • pp.323-328
    • /
    • 1986
  • This paper describes on the distribution of polynuclear aromatic hydrocarbons (PAHs) in various size of atmospheric particulate matter (A.P.M.). A.P.M. in Seoul city were collected on guartz fiber filter according to particle size using an Andersen high volume air sampler from Feb. 1983 to March 1984. And 7 PAHs [benzo(a)pyrene, benzo(k)fluoranthene, benzo(ghi)perylene, benzo(e) pyrene, perylene, chrysene, and pyrene] were analyzed by high performance liquid chromatography. The concentration of A.P.M. showed spring-winter maxima and summer-autumn minia. The A.P.M. was lowest in the concentration at the 1.1~3.3$\mu\textrm{m}$ particulates, and the concentration increased as the particle size increased or decreased. But the concentrations of PAHs increased with the decrease in the particle size, and were predominant in winter. The correlations among the PAHs were high. And there fore, benzo(a)pyrene concentration could be considered as the representive of PAHs.

  • PDF