A Study on the Removal Characteristics of Indoor Air Pollutants using the Air Cleaning System (실공간에서 공기정화시스템을 이용한 실내 오염 입자 제거 특성에 관한 연구)

  • Koo, Jeong-Hwan;Kim, Seong-Chan;Kim, Jang-Woo;Lee, Ju-Yong;Lee, Jae-Keun;Kang, Tae-Wook;Lee, Kam-Gyu
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.532-537
    • /
    • 2000
  • The purpose of this study is to determine the performance of a commercial air cleaner in removing tobacco smoke indoors. Following injection of tobacco smoke in a room, decay rates for particle concentrations were obtained far mass concentration at each point. The size distribution of the tobacco smoke particles was approximately $1.266{\mu}m$ in mass median diameter with a geometric standard deviation of 1.313. The air cleaner consisted of an electrostatic filtration unit and a fan operated at a flow rate of 5.98 CMM. The collection efficiency for $>1\;{\mu}m$ was more than 99%. Without air cleaner operation, tobacco smoke concentration ratio in room decreased to 30% of initial values within 30 minutes and with air cleaner operation, decreased to 90% of initial values in the test chamber, volume $51.27\;m^3$. Without air cleaner operation, tobacco smoke concentration ratio in room decreased to 10% of initial values within 30 minutes and with air cleaner operation, decreased to 30-70% of initial values in the test chamber, volume $149.2\;m^3$.

  • PDF

Premixed Combustion Characteristics of Coal Gasification Fuel in Constant Volume Combustion Chamber (석탄가스화 연료의 정적 예혼합 연소특성)

  • Kim Tae-Kwon;Jang Jun-Young
    • Journal of Environmental Science International
    • /
    • v.15 no.6
    • /
    • pp.601-606
    • /
    • 2006
  • The coal gasification fuel is important to replace petroleum fuel. Also they have many benefits for reducing the air pollution. Measurements on the combustion characteristics of synthetic gas from coal gasification have been conducted as compared with LPG in constant volume combustion chamber. The fuel is low caloric synthetic gas containing carbon monoxide 30%, hydrogen 20%, carbon dioxide 5%, and nitrogen 45%. To elucidate the combustion characteristics of the coal gasification fuel, the combustion pressures, combustion durations, and pollutants(NOx, $CO_2$, CO) are measured with equivalence ratios($\phi$), and initial pressures of fuel-air mixture in constant volume chamber. In the case of the coal gasification fuel, maximum combustion pressure and NOx concentration are lower rather than LPG fuel. However CO and $CO_2$ emission concentration are similar to that of LPG fuel.

A study on Pb, Zn and Fe Concentrations of Ambient Air Adjacent to Heavy Traffic Road Side in Seoul (서울시 주요 도로변 대기중 납, 아연 및 철 농도에 관한 조사연구)

  • 조준호;박석환;정문식
    • Journal of Environmental Health Sciences
    • /
    • v.24 no.2
    • /
    • pp.110-117
    • /
    • 1998
  • This study was carried out to investigate the concentrations of TSP, Pb, Zn and Fe in ambient air adjacent to the heavy traffic road side in Seoul from October 1 to October 31, 1997. The results were as follows 1. The concentrations of TSP were 260 $\mu g/m^3$, 184 $\mu g/m^3$, 147 $\mu g/m^3$ in Chongro, Chungkechun and Kangnam-terminal, respectively. The concentration of TSP was correlated with the traffic volume of the sampling sites (r=0.77). 2. The concentrations of Pb were 638 ng/m$^3$, 335 ng/m$^3$, 233 ng/m$^3$ in Chungkechun, Kangnam-terminal and Chongro, respectively. The concentration of Pb was correlated with the Truck (over 1.4 ton) volume of the sampling sites (r=0.71). The Pb contents among these sites were significantly different (p < 0.05). 3. The concentrations of Zn were 535 ng/m$^3$, 461 ng/m$^3$, 439 ng/m$^3$ in Chongro, Kangnam-terminal and Chungkechun, respectively. The concentration of Zn was badly correlated with the traffic volume of the sampling sites (r=0.23). 4. The concentrations of Fe were 5.32 $\mu g/m^3$, 4.51 $\mu g/m^3$ and 3.18 $\mu g/m^3$ in Chongro, Kangnam-terminal and Chungkechun, respectively. The concentration of Fe was correlated with the traffic volume of the sampling sites (r=0.83). The Fe contents among these sites were significantly different (p < 0.05). 5. The concentrations of TSP, Pb, Zn, Fe investigated didn't exceed the Korean Ambient Air Quality Standards, but more researches in relation to these will be required in considering people working in these sites suffered from cough, asthma and chronic headache.

  • PDF

COMBUSTION CHARACTERISTICS OF HOMOGENEOUS CHARGED METHANE-AIR MIXTURE IN A CONSTANT VOLUME COMBUSTION CHAMBER

  • CHOI S. H.;CHO S. W.;JEONG D. S.;JEON C. H.;CHANG Y. J.
    • International Journal of Automotive Technology
    • /
    • v.6 no.4
    • /
    • pp.323-332
    • /
    • 2005
  • A cylindrical constant volume combustion chamber was used to investigate the flow characteristics at the spark electrode gap and the combustion characteristics of a homogeneous charged methane-air mixture under various overall charge pressures, excess air ratios and ignition times. The flow characteristics, including the mean velocity and turbulence intensity, were analyzed with a hot wire anemometer. Combustion pressure development measured by piezoelectric pressure transducer, a flame propagation image acquired by ICCD camera and exhaust emissions measured by 2-valve gas chromatography were used to investigate effects of initial pressures, excess air ratios and ignition times on the combustion characteristics. It was found that the mean velocity and turbulence intensity had the maximum value around 200-300 ms and then decreased gradually to a near-zero value after 3000 ms and that the combustion duration was shorten and the flame speed and laminar burning velocity had the highest value under the condition of an excess air ratio of 1.1, an overall charge pressure of 0.15 MPa and an ignition time of 300 ms in the present study. The $CO_2$ concentration was proportional to the ignition time and overall charge pressure, the $CO_2$ concentration was proportional to the excess air ratio, and the UHC concentration was inversely proportional to the ignition time and overall charge pressure.

Natural Convection for Air-Layer between Body Skin and Clothing with Considering Coefficient of Permeability (투과계수를 고려한 의복과 인체 사이의 공기층에서 자연대류 특성)

  • 지명국;배강렬;정효민;정한식;추미선
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.12
    • /
    • pp.1282-1287
    • /
    • 2001
  • This study presents the numerical analysis of natural convection of a micro- environments with air permeability in the clothing air-layer. As a numerical model the clothing air layer of shoulder and arm were adopted. Finite volume method for two-dimensional laminar flow was used for the analysis of flow and thermal characteristics of velocity, temperature and concentration in the air layer between body and clothing. As temperature boundary conditions, a body skin has a high temperature with $34^{\circ}C$ and the environmental temperatures are 5, 15 and $25^{\circ}C$ for various permeability coefficients. The distributions of concentration, temperature and velocity are shown that two large cells form at horizontal and vertical air layer, respectively. As the temperature difference between body skin and environment decreases, the heat transfer is decreased rapidly.

  • PDF

Studies on the Total Suspended Particulates in Iksan City. (익산시의 부유먼지에 관한 연구)

  • 전병영
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.4
    • /
    • pp.158-164
    • /
    • 1999
  • This study was carried out to investigate total suspended particulates (TSP) in Iksan area collected by nine stages Anderson air sampler and High volume air sampler from Jul. 1996 to Jul. 1998.The results are as follows1. The average of TSP concentration to be collected by Anderson air sampler and High volume air sampler in Iksan city are $59{\mu}g/m^3$, $67{\mu}g/m^3$. It was below the level of environmental standard. 2. The average of TSP concentration by measured method are HVAS > AS > Gov. 3. The average of TSP concentration on seasonal change are higher spring than winter. It were $65.5{\mu}g/m^3$ of Spring, $57{\mu}g/m^3$ of Summer, $52.5{\mu}g/m^3$ of Fall, $61{\mu}g/m^3$ of Winter. 4. Particle size 3istribution of atmospheric particulate was divided into two groups, coarse group was made by particles larger than $1.1-2.1{\mu}m$ in diameter and fine groups smaller than $1.1-2.1{\mu}m$ in diameter. about 50% of total suspended particle measured by Anderson air sampler during the sampling period was coarse particle.

  • PDF

Comparison of PM 10 concentration between Gent Sampler and High-volume air sampler (Gent sampler와 High-volume air sampler의 분진 농도 비교연구)

  • 임종명;이현석;장미숙;이진홍
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.05b
    • /
    • pp.275-276
    • /
    • 2003
  • 산업의 발달에 따른 환경 오염물질의 증가와 오염물질의 종류가 다양화됨에 따라 대기 중의 유해원소 및 미량원소에 의한 환경오염과 그로 인한 인체건강에 대한 영향은 인간생활에 심각한 문제가 되므로 대기 중의 농도를 정확히 측정하는 것은 매우 중요한 일이다. 특히 미세 입자는 오염된 도심지역 분진수의 90∼99%에 이르는 높은 비율을 보이고 있고, 폐 깊숙이 침투하여 폐암을 비롯한 폐질환을 일으킬 수 있다. (중략)

  • PDF

Energy Saving Potential and Indoor Air Quality Benefits of Multiple Zone Dedicated Outdoor Air System

  • Lee, Soo-Jin;Jeong, Jae-Weon
    • International Journal of High-Rise Buildings
    • /
    • v.8 no.1
    • /
    • pp.71-82
    • /
    • 2019
  • The purpose of this study is to evaluate the indoor air quality (IAQ) and energy benefits of a dedicated outdoor air system (DOAS) and compare them with a conventional variable air volume (VAV) system. The DOAS is a decoupled system that supplies only outdoor air, while reducing its consumption using an enthalpy wheel. The VAV system supplies air that is mixed outdoor and transferred indoor. The VAV has the issue of unbalanced ventilation in each room in multiple zones because it supplies mixing air. The DOAS does not have this problem because it supplies only outdoor air. That is, the DOAS is a 100% outdoor air system and the VAV is an air conditioning system. The transient simulations of carbon dioxide concentration and energy consumption were performed using a MATLAB program based on the thermal loads from the model predicted by the TRNSYS 18 program. The results indicated that when the air volume is large, such as in summer, the distribution of air is not appropriate in the VAV system. The DOAS however, supplies the outdoor air stably. Moreover, in terms of annual primary energy consumption, the DOAS consumed approximately 40% less energy than the VAV system.

A Study on the Application of VAV/BPFS(Variable-Air-Volume/Bypass Filtration System) for Indoor Air Environment (VAV/BPFS(Variable-Air-Volume/Bypass Filtration System) 의 실내환경 적응에 관한 연구)

  • 최성우
    • Journal of Environmental Science International
    • /
    • v.12 no.12
    • /
    • pp.1235-1243
    • /
    • 2003
  • Under controlled conditions in an environmental chamber, 24 experiments were performed to compare the ability of a Variable-Air-Volume/Bypass Filtration System(VAV/BPFS) to remove indoor pollutants and to conserve energy with the ability of conventional Variable Air Volume(VAV) system. The specific conclusions of this paper were; first, the VAV/BPFS was more efficient than the VAV system in removing particulate matter, TVOC, and target VOCs. The total effective removal rate of PM for the VAV/BPFS was two times as high as that of the VAV system. The total effective removal rate of TVOC for the VAV/BPFS was 20 percent higher than that of the VAV system. Also each target VOC concentration was reduced by using the VAV/BPFS. Second, clean air delivery rate was increased by using VAV/BPFS due to additional filtration rate. Otherwise, the VAV/BPFS decreased outdoor supply air rate above 25 percent relative to the rate of VAV system. Third, total energy consumption by the VAV/BPFS was lower than that of the VAV system during the period with indoor thermal load, occupied time. The energy saving of the VAV/BPFS ranged from 11 to 16 percent. The VAV/BPFS improves indoor air quality more efficiently than the VAV system, and it reduced energy consumption. Retrofitting the VAV system with the VAV/BPFS was easy The use of VAV/BPFS is, therefore, recommended far buildings with VAV system as well as for buildings at designing stage.

Natural Convection for Air-Layer between Clothing and Body Skin (의복과 인체의 공기층에 관한 자연대류 특성)

  • Ji, M.K.;Bae, K.Y.;Chung, H.S.;Jeong, H.M.;Chu, M.S.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.648-653
    • /
    • 2001
  • This study represents the numerical analysis of natural convection of a microenvironments with a air permeability in the clothing air-layer. The clothing air layer of shoulder and arm was used for numerical analysis model. As a numerical analysis method, we adopted a finite volume method for two-dimensional laminar flow, and analyzed the flow and thermal characteristics of velocity, temperature and concentration in the air layer between body and clothing. As a temperature boundary conditions, we considered that a body skin has a high temperature with $34^{\circ}C$ the environmental temperatures are $5,\;15\;and\;25^{\circ}C$ for various permeability coefficients. The distributions of concentration, temperature and velocity were showed that two large cells were. formed at horizontal and vertical air layer, respectively. As the temperature difference between body skin and environment decrease, the heat transfer was decreased rapidly.

  • PDF