• Title/Summary/Keyword: Air Uniformity

Search Result 250, Processing Time 0.343 seconds

공냉식 리튬 이온 배터리 팩의 열 성능 향상을 위한 내부 구조 최적화 (Internal Structure Optimization to enhance the Thermal Performance of an Air-cooled Lithium-ion Battery Pack)

  • ;조종래
    • 한국기계가공학회지
    • /
    • 제20권12호
    • /
    • pp.54-64
    • /
    • 2021
  • Electric vehicles use lithium-ion battery packs as the power supply, where the batteries are connected in series or parallel. The temperature control of each battery is essential to ensure a consistent overall temperature. This study focused on reducing ohmic heating caused by batteries to realize a uniform battery temperature. The battery spacing was optimized to improve air cooling, and the tilt angle between the batteries was varied to optimize the internal structure of the batterypack. Simulations were performed to evaluate the effects of these parameters, and the results showed that the optimal scheme effectively achieved a uniform battery temperature under a constant power discharge. These findings can contribute to future research on cooling methods for battery packs.

근적외 분광법을 이용한 양념 야채의 건조 불균일성 관찰 (Observation for drying non-uniformity of allium vegetables using NIR spectroscopy)

  • 조형호;이선미;박상욱;조래광
    • 한국식품저장유통학회지
    • /
    • 제21권6호
    • /
    • pp.838-843
    • /
    • 2014
  • 본 연구에서는 근적외 분광법을 이용하여 양념용 채소로 많이 사용되는 파, 마늘, 양파의 건조 불균일성을 관찰하였다. 대류식 온풍건조기에서 건조 위치에 따른 양념채소류의 건조 상태 차이를 조사한 결과, 건조 트레이의 높이나 위치에 따라 바람의 온도와 습도에 차이가 발생하여 건조가 균일하게 되지 않았다. 건조 정도가 다른 양념채소류의 2차 미분 근적외 스펙트럼을 비교한 결과 1,390 nm에서 1,400 nm 부근의 수소결합이 약한 물이 먼저 증발되었고 1,420 nm 부근의 수소결합이 강한 물은 건조 후에도 잔존함을 관찰할 수 있었다. 초분광 NIR 이미징 기법으로 측정한 스펙트럼을 주성분분석함으로써 건조채소의 건조도를 가시적으로 판별할 수 있었다.

고속 고부하 상태의 DISI 엔진에서 메탄올-가솔린 혼합연료의 연료 혼합비와 2단 분사가 엔진 내부유동 및 연소특성에 미치는 영향 (The Effect of Mixing Rate and Multi Stage Injection on the Internal Flow Field and Combustion Characteristics of DISI Engine Using Methanol-gasoline Blended Fuel at High Speed / High Load Condition)

  • 배진우;서주형;이재성;김호영
    • 한국자동차공학회논문집
    • /
    • 제21권5호
    • /
    • pp.15-24
    • /
    • 2013
  • Numerical studies were conducted to investigate the internal flow field and combustion characteristics of DISI engine with methanol blended in gasoline. Dual injection was applied and the characteristics were compared to single injection strategy. The amount of the fuel injection was corresponded to air-fuel ratio of each fuel for complete combustion. The preforming model in this study, software STAR-CD was employed for both modeling and solving. The operating speed condition were at 4000 rpm/WOT (Wide open throttle) where the engine was fully warmed. The results of single injection with M28 showed that the uniformity, equivalence ratio, in-cylinder pressure and temperature increased comparing to gasoline (M0). When dual injection was applied, there was no significant change in uniformity and equivalence ratio but the in-cylinder pressure and temperature increased. When M28 fuel and single injection was applied, the CO (Carbon monoxide) and NO (Nitrogen oxides) emission inside the combustion chamber increased approximately 36%, 9% comparing with benchmarking case in cylinder prior to TWC (Three Way Catalytic converter). When dual stage injection was applied, both CO and NO emission amount increased.

폐열 회수 시스템용 공랭식 응축기의 압력 손실 저감 설계 (A Design Process for Reduction of Pressure Drop of Air-cooled Condenser for Waste Heat Recovery System)

  • 배석정;허형석;박정상;이홍열;김찬중
    • 한국자동차공학회논문집
    • /
    • 제21권6호
    • /
    • pp.81-91
    • /
    • 2013
  • A novel design process of a parallel multi-flow type air-cooled condenser of a dual-loop waste heat recovery system with Rankine steam cycles for improving the fuel efficiency of gasoline automobiles has been investigated focusing on reduction of the pressure drop inside the micro-tubes. The low temperature condenser plays a role to dissipate heat from the system by condensing the low temperature loop working fluid sufficiently. However, the refrigerant has low evaporation temperature enough to recover the waste from engine coolant of about $100^{\circ}C$ but has small saturation enthalpy so that excessive mass flow rate of the LT working fluid, e.g., over 150 g/s, causes enormously large pressure drop of the working fluid to maintain the heat dissipation performance of more than 20 kW. This paper has dealt with the scheme to design the low temperature condenser that has reduced pressure drop while ensuring the required thermal performance. The number of pass, the arrangement of the tubes of each pass, and the positions of the inlet and outlet ports on the header are most critical parameters affecting the flow uniformity through all the tubes of the condenser. For the purpose of the performance predictions and the parametric study for the LT condenser, we have developed a 1-dimensional user-friendly performance prediction program that calculates feasibly the phase change of the working fluid in the tubes. An example is presented through the proposed design process and compared with an experiment.

주거단지 지하주차장의 조명계획 및 운영방법 (A Lighting Plan and Operation Strategy for Underground Parking Garages in Residential Areas)

  • 장수정;최안섭
    • 조명전기설비학회논문지
    • /
    • 제19권4호
    • /
    • pp.47-54
    • /
    • 2005
  • 어둡고 한정된 지하공간의 이미지의 개선은 지하개발 성공여부에 중요한 결정요소가 되고 있다. 주거단지 지하주차장의 조명환경은 지금까지 양적 위주의 설계와 운영이 이루어졌으나 이제는 지하주차장 공간의 질적 향상이 필요한 때이다. 이를 위해서 우선 고려해야 할 두 가지는, 첫째로 주차장에서 주로 사용되는 광원에 대한 이해이며, 둘째는 균제도의 향상이다. 특히 겨울철 외기의 영향에 의한 주차장 실내의 심각한 조도저하와 균제도의 유지를 위한 방안이 마련되어야 한다. 따라서 조명기구의 간격, 배열에 대한 변화가 필요하며, 운용에 있어서는 시간에 따른 일률적인 기존의 제어방법에서 벗어나 이용패턴을 고려한 방식으로의 전환이 요구된다.

빙해수조 공냉 시스템 변화에 따른 결빙 균질도 비교 전산해석 (Computational Analysis for Effects of Cooling System on Homogeneity of Ice Thickness and Temperature on Water Surface)

  • 이승수;김영민;이춘주
    • 대한조선학회논문집
    • /
    • 제50권3호
    • /
    • pp.167-174
    • /
    • 2013
  • Model ice forming process in ice tank needs several steps of seeding, freezing, tempering. In those process, one of the most important factors to affect the accuracy of experiment is the homogeneity of the ice thickness and the temperature. This paper investigated a computational and statistical method to assess the uniformity of the model ice. In addition, the different configurations of freezing systems were considered to improve the uniformity. Qualitative assessment using streamlines from the cooling units was carried out by computational fluid dynamics (CFD) and the quantitative evaluations of the homogeneity were compared using the temperature distribution on the ice surface. In addition, multi species transport analysis is introduced to understand the circulation efficiency of cold air from the cooling units. As the results, optimized configurations were determined by adjusting the angles of vane in the cooling units.

다중 흡수정을 갖는 펌프장 모델의 유동균일성 해석 (Numerical Analysis on the Flow Uniformity in a Pump Sump Model with Multi Pump Intake)

  • 최종웅;최영도;임우섭;이영호
    • 한국유체기계학회 논문집
    • /
    • 제12권4호
    • /
    • pp.14-22
    • /
    • 2009
  • The head-capacity curves for pumps developed by the pump manufacturer are based on tests of a single pump operating in a semi-infinite basin with no close walls or floors and with no stray currents. Therefore, flow into the pump intake is with no vortices or swirling. However, pump station designers relying on these curves to define the operating conditions for the pump selected sometimes meet the reductions of capacity and efficiency, as well as the increase of vibration and additional noise, which were caused by air-entered flow in the pump station. From this background, the authors are carrying out a systematic study on the flow characteristics of intakes within a sump of pump station model. Multi-intake sump model with anti-submerged vortex device basin is designed and the characteristics of submerged vortex is investigated in the flow field by numerical simulation. In this study, a commercial CFD code is used to predict the vortex generation in the pump station accurately. The analysed results by CFD show that the vortex structure and effect of anti-submerged vortex device are different at each pump intake channel.

Numerical simulation of a regenerative thermal oxidizer for volatile organic compounds treatment

  • Hao, Xiaowen;Li, Ruixin;Wang, Jiao;Yang, Xinfei
    • Environmental Engineering Research
    • /
    • 제23권4호
    • /
    • pp.397-405
    • /
    • 2018
  • As regulations governing the control of volatile organic compounds (VOCs) have become increasingly stringent in China, regenerative thermal oxidizers (RTOs) have been more frequently applied in medium- and high-concentration VOCs treatments. However, due to the lack of existing RTO-related research, experience remains a dominant factor for industrial application. This paper thus aimed to establish a model for industrial RTOs, using a transient simulation method and thermal equilibrium model to simulate the internal velocities and temperature distributions of an RTO across multiple cycles. A comparison showed an error of less than 5% between most correlating simulated and experimental measurement points, verifying that the simulation method was accurate. After verification, the velocity and temperature fields inside the RTO were simulated to study the uniformity of temperature and velocity within the packed beds: both fields displayed high uniformity after gas flowed through the honeycomb regenerator. The effects of air volume, VOCs concentrations, and valve switching times on the oxidation chamber temperature, RTO outlet temperature, and thermal efficiency (as well as their averages) were studied. The VOCs removal rate in this study was constantly above 98%, and the average thermal efficiency reached 90%.

대기오염에 의한 치과위생사의 자각증상 특성 (A Sbjective Symptom on Outdoor Air Quality in Dental Hygienist)

  • 지동하;최미숙;손부순
    • 환경위생공학
    • /
    • 제22권2호
    • /
    • pp.1-8
    • /
    • 2007
  • This research is based on self-filling survey which 656 dental hygienists who work in, seoul, the metropolitan area, jeon-buk area participated on July 2006 through August 2006. This survey was analyzed the relationship between the subjective symptoms(6 types) and outdoor air quality($O_3,\;NO_2,\;CO,\;SO_2,\;PM_{10}$) As follows analyzed results. The health condition of dental hygienists were "Feel Good" more than 50% in last month. The experience the symptoms level is higher then non-experience level in "Dry eye, itch, smarting", "Headaches", "Fatigue and sleepiness", "Red eye", "Hypersensitivity", "Dorsalgia, omarthralgia, cervicodynia". We anticipated that the more experience the subjective symptom the more likely it is that outdoor air quality will be high rate level. But we could not find the uniformity in metropolitan-area and seoul-area. In the case of jeonbuk area, the group's pollution density levels which experienced the subjective symptom were appeared high rate than inexperienced group except $SO_2$. It probably comes from sensibility for an air pollution in this area. Dental hygienists who work in jeonbuk area have an unusual sensibility for an air pollution because outdoor air quality of jeonbuk area was rule good rather than others area. especially $SO_2$ was revealed out even though low rate level in inexperienced group it is that the number of cars in jeonbuk area is increasing rapidly.

DAF 공정에서 공기포화장치와 노즐 특성 별 미세기포 발생에 미치는 영향 (An Effect of the Micro Bubble Formation Depending on the Saturator and the Nozzle in the Dissolved Air Flotation System)

  • 박상철;오호영;정몽규;송석용;안용희
    • 대한환경공학회지
    • /
    • 제35권12호
    • /
    • pp.929-936
    • /
    • 2013
  • DAF (Dissolved air flotation) 공정에서 공기포화장치(Saturator)와 미세기포 발생노즐은 미세기포 형성에 중요한 영향을 미치는 장치이다. 미세기포 발생 효율을 증가시키기 위해서는 공기포화장치 용기 안에서 기-액 접촉 효율을 증가시키고, 미세기포 발생노즐까지 이송 배관 내 압력을 일정하게 유지해 주어야 한다. 본 연구에서는 공기포화장치 내 순환수 유입 분사노즐과 포화수 이송 배관, 미세기포 발생노즐에 의한 미세기포 발생에 미치는 영향을 공기체적법과 기포 크기, 기포의 잔류시간 측정을 통해 비교해 보았다. 순환수 유입 분사노즐을 설치하고, 포화수의 이송 배관 내 압력손실이 발생하지 않는 구조, 미세기포 발생노즐의 통과유속을 증가시킬 경우 미세기포 발생 성능이 증가하였다.