• 제목/요약/키워드: Air Tank

검색결과 609건 처리시간 0.022초

냉열잠열축열조의 성능해석 (Performance of the Cold Latent Storage System)

  • 윤호식;노승탁
    • 대한설비공학회지:설비저널
    • /
    • 제17권4호
    • /
    • pp.456-465
    • /
    • 1988
  • The performance of the cold latent heat storage is investigated by experiment and by a simplified analytic approach. The heat storage tank has eight horizontal circular tubes and one path of refrigerant evaporating tube. The phase change material in the heat storage tank is water which is frozen by evaporating refrigerant of refrigeration system and melts by the warm air in the heat storage tank. In the experiment, the performance has been studied by the various conditions including the initial water temperature on solidification and flow rate and temperature of air. The rate of recovered heat has been simulated by a simplified model and the results shows a good agreement. In solidification process, initial water temperature causes time delay corresponding to the sensible heat and it is found that the shape of evaporator is important. In melting process, the recovered heat rate from the heat storage tank is proportional to $Re^{0.8}(T_{bi}-T_f)$ of air where $T_{bi}$ and $T_f$ indicate temperatures of inlet air and phase change, respectively. And the deminishing rate of the recovered heat is higher for the higher heat rate.

  • PDF

탈기에 의한 심층포기 호기조 MLSS (Mixed Liquor Suspended Solid) 침전성 향상 방안 연구 (Study to enhance the settleability of deep aeration tank MLSS (Mixed Liquor Suspended Solid) by air sparging)

  • 한지수;이제승;이병희
    • 상하수도학회지
    • /
    • 제38권3호
    • /
    • pp.165-175
    • /
    • 2024
  • The dissolved air at the bottom layer of the deep aeration tank transforms into fine gas bubbles within the MLSS (Mixed Liquor Suspended Solid) floc when exposed to the atmosphere. MLSS floc flotation occurs when MLSS from the deep aeration tank enters the secondary clarifier for solid-liquid separation, as dissolved air becomes fine air within the MLSS floc. The floated MLSS floc causes a high SS (Suspended Solid) concentration in the secondary effluent. The fine air bubbles within the MLSS floc must be removed to achieve stable sedimentation in the secondary clarifier. Fine bubbles within the MLSS floc can be removed by air sparging. The settleability of MLSS was measured by sludge volume indexes (SVIs) after air sparging MLSS taken at the end of the deep aeration tank. MLSS settling tests were performed at MLSS heights of 200, 300, 400, and 500 mm, and compressed air was fed at the bottom of the settling column with air flow rates of 100, 300, and 500 ml/min at each MLSS height, respectively. Also, at each height and air flow rate, air was sparged for 3, 5, and 7 minutes, respectively. SVI was determined for each height, air flow rate, and sparging time, respectively. Experimental results showed that a 300 mm MLSS height, 300 ml/min air flow rate, and 3 minutes of sparging time were the least conditions to achieve less than 120 ml/g of SVI, which was the criterion for good MLSS settling in the secondary clarifier.

연료탱크 진공주유절차 개발 (Development of Vacuum Refueling Process for Fuel Tank)

  • 박정배;민성기;이세영;김영신;이종철;장기원
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2011년도 제36회 춘계학술대회논문집
    • /
    • pp.385-390
    • /
    • 2011
  • 연료탱크 내부에 존재하는 공기는 저장중 연료의 산화를 유발하고, 연료 이송성능을 저하시킬 수 있다. 따라서 항공기 연료탱크의 주유절차를 개선하기 위하여 연료탱크 내부에 존재하는 공기를 줄이는 방안으로 진공주유방식을 제안하였다. 본 논문에서는 진공주유 절차를 수립하여 실제 시험을 수행해 보았고, 이를 통해 진공주유중 발생하는 현상을 관찰할 수 있었다. 또한 탱크 내부의 기포 및 주유시간 절감을 위하여 다른 개선된 방안들을 제안하였다.

  • PDF

약품(액상소석회) 저장조 준설 작업자의 유해인자 특성 평가 사례 (Characteristics of Hazardous Factors Regarding Chemical(Liquid Lime) Storage Tank Dredging Workers)

  • 김제훈;김기연
    • 한국산업보건학회지
    • /
    • 제34권1호
    • /
    • pp.1-7
    • /
    • 2024
  • Objectives: The study was performed to investigate characteristics of hazardous factors regarding chemical(liquid lime) tank dredging workers by case survey. Methods: Field data such as working condition, MSDS and respirators applied to chemical tank dredging work were analyzed and the work environmental factors of noise and indoor air quality were measured to compare existing data with actual work situations. Results: No health hazards to workers due to working conditions were confirmed during dredging work inside the chemical storage tank. All air quality measurement data during dredging work satisfied the management standards, and there were no by-products. During dredging work, there was a significant change in noise depending on the type of work, but considering the noise reduction rate(NRR) of the earplugs worn by workers, there was no actual health hazard due to noise exposure. Conclusions: A fit test for respirator and the expiration date of the safety helmet should be observed to ensure an appropriate level of safety and health for dredging workers in the chemical storage tank.

열교환코일 내장형 태양열 축열조의 성능향상 (제1보 실증실험) (Performance Enhancement of Solar Thermal Storage Tank with Heat Exchange Coils (Part 1 : Verification Experiment))

  • 이욱재;홍희기
    • 설비공학논문집
    • /
    • 제27권4호
    • /
    • pp.213-219
    • /
    • 2015
  • A thermal storage tank with internal heat exchange coils is commonly used in solar thermal systems with a collector area below $100m^2$. The coils are installed in the lower part of the tank because the temperature of the upper part of the tank can drop if the outlet temperature of the collector becomes lower than the upper temperature of the tank, which is a kind of temperature reversal. As an alternative to the well-mixed storage tank with lower coil only, we have proposed a tank with lower and upper coils and have achieved superior thermal stratification in the tank, which results in increased collector efficiency and solar fraction. But, the phenomenon of temperature reversal was often observed in the tank when the load or solar radiation changed rapidly. In the present work, revised control was successfully applied, i.e., to heat only the lower coil using a three way valve if temperature reversal occurs and to operate the collector at a low flow rate when the quality of solar radiation is not good.

통합보존식 해석과 HCIB 법을 이용한 슬로싱 탱크 내부 갇힌 공기에 의한 압력 진동 모사 (Simulation of a Pulsating Air Pocket in a Sloshing Tank Using Unified Conservation Laws and HCIB Method)

  • 신상묵
    • 대한조선학회논문집
    • /
    • 제58권5호
    • /
    • pp.271-280
    • /
    • 2021
  • The code developed using a pressure-based method for unified conservation laws of incompressible/compressible fluids is expanded to handle moving or deforming body boundaries using the hybrid Cartesian/immersed boundary method. An instantaneous pressure field is calculated from a pressure Poisson equation for the whole fluid domain, including the compressible gas region. The polytropic gas is assumed for the compressible fluid so that the energy equation is decoupled. Immersed boundary nodes are identified based on edges crossing body boundaries. The velocity vector is reconstructed at the immersed boundary node using an interpolation along the assigned local normal line. The developed code is validated by comparing the time histories of pressure and wave elevation for sloshing in a rectangular and a membrane-type tank. The validated code is applied to simulate air cushion effects in a rectangular tank under sway motion. Time variations of pressure fields are analyzed in detail as the air pocket pulsates. It is shown that the contraction and expansion of the air pocket dominate the pressure loads on the wall of the tank. The present results are in good agreement with other experimental and computational results for the amplitude and the decay of the pressure oscillations measured at the pressure gauges.

태양열 시스템에 적용된 나선재킷형 축열조의 실증실험 (Experimental Verification for a Spiral-Jacketed Storage Tank Applied to Solar Thermal System)

  • 김진홍;최봉수;홍희기;김용식
    • 설비공학논문집
    • /
    • 제17권4호
    • /
    • pp.341-346
    • /
    • 2005
  • The simplification of solar thermal systems reduces the possibility of operating trouble and lowers the cost of the initial investment and maintenance. This also leads to increased competitiveness in the energy market. We proposed a spiral-jacketed storage tank that functions both as a heat exchanger and expansion tank, which removes the secondary piping and markedly simplifies the entire system. The new storage tank was designed and manufactured to maintain the same performance as the conventional system and the exiting system was remodelled by adopting the newly proposed storage tank. This experiment was conducted under real conditions over a period of several months. The retrofitted system with the spiral-jacketed storage tank showed good performance that is on a similar level as the previous system having a typical storage tank and heat exchanger.

자흡방식에 의해 마이크로버블을 발생시키는 충돌 노즐에 대한 연구 (A Study on the Collision Nozzle for Generating Microbubble by Self-Suction Method)

  • 강우진;박상희;유성훈
    • 한국산업융합학회 논문집
    • /
    • 제26권6_2호
    • /
    • pp.1047-1053
    • /
    • 2023
  • An experimental study was performed on the collision nozzle system that generates microbubble by air self-suction using a venturi nozzle. This study experimentally investigates the pressure of a pump and a dissolution tank, water flow rate, air self-suction amount and microbubble generation amount. The experimental conditions were varied by changing the diameter of the collision nozzle (de=4,5,6,7,8mm), the pumping power(0.5hp, 1.0hp) and the capacity of the dissolution tank(4.4L, 8/8L). The pressure change of the pump according to the outlet diameter of the collision nozzle showed that the 1.0hp pump power operated more stably than the 0.5hp pump. The pressure change in the dissolution tank was shown to decrease rapidly as the outlet diameter of the nozzle increased. The flow rate of recirculating water was shown to increase as the nozzle diameter increased. Additionally, it was shown that the pump capacity of 1.0hp increased the flow rate more than that of 0.5hp. The self-suction air flow rate was shown to occur above de=6mm, and the air flow rate increased as the nozzle diameter increased. Also, as the pump capacity increased, the self-suction amount of air increased. It was shown that the amount of microbubble less than 50mm generated was maximum when the nozzle diameter was 6mm, the pump power was 1.0hp, and the dissolution tank capacity was 8.8L.

왕복동식 공기압축기의 소음저감에 관한 공학적 대책 연구 (Noise Reduction of Reciprocating Type Air Compressors)

  • 이광기;박재석
    • 한국안전학회지
    • /
    • 제21권5호
    • /
    • pp.12-16
    • /
    • 2006
  • This paper deals with the noise evaluation and noise reduction of a reciprocating air-compressor. The reciprocating air-compressor is widely used in the small and medium sized industrial firms, many employees exposed and irritated by their noise in the workplace. Thus, appropriate noise control actions should be taken to prevent hearing loss due to the its noise exposure. Lead-wrapping techniques are employed to identify the contribution of principal noise sources which are generally known to be motor, belts, suction valves, discharge valves, moving parts, and flow-induced noise caused by edges or discontinuities along the flow path including expansions, contractions, junctions and bends. As a result, the main noise sources of the air-compressor are categorized by the suction and discharge noise, valve noise, and compressed air tank noise. Based on the investigations, mufflers are designed to reduce both the suction and discharge noise and the compressed-air tank noise. Instead of the conventional valve plate, polyethylene resin is used the reduction of valve impact noise. In addition, attempts are made to reduce the valve noise propagation to the cylinder head and the compressor tank by using the insulation casings. As a result of the countermeasure plans, a noise reduction up to 10dB(A) could be achieved for the air-compressor.

태양열 콤비시스템의 축열조에 적용되는 분배기의 효과 (The Effect of a Manifold in a Storage Tank Applied to a Solar Combisystem)

  • 손효석;홍희기
    • 설비공학논문집
    • /
    • 제26권7호
    • /
    • pp.322-328
    • /
    • 2014
  • Return piping is used in a solar combi-system for heating and hot water supply. When the temperature of the lower side of a storage tank is low due to hot water usage, the returned hot water after heating is mixed with the lower side cold water of the tank, and the useful energy is reduced. We studied the degree of thermal stratification in the tank, using either a diffuser or a manifold to prevent mixing. Using the diffuser, mixing starts from the bottom of the storage tank. On the other hand, the manifold has the marked effect of preventing mixing. As a result of experiments with changing the diameter and number of holes in the manifold, the optimum condition is 8.5 mm diameter and 96 holes, under the condition of 0.3 lpm.