• 제목/요약/키워드: Air Supply

검색결과 1,521건 처리시간 0.025초

중앙냉방시스템의 최적제어에 관한 연구 (Optimal Control for Central Cooling Systems)

  • 안병천
    • 설비공학논문집
    • /
    • 제12권4호
    • /
    • pp.354-362
    • /
    • 2000
  • Optimal supervisory control strategy for the set points of controlled variables in the central cooling system has been studied by computer simulation. A quadratic linear regression equation for predicting the total cooling system power in terms of the controlled and uncontrolled variables was developed using simulated data collected under different values of controlled and uncontrolled variables. The optimal set temperatures such as supply air temperature, chilled water temperature, and condenser water temperature, are determined such that energy consumption is minimized as uncontrolled variables, load, ambient wet bulb temperature, and sensible heat ratio, are changed. The chilled water loop pump and cooling tower fan speeds are controlled by the PID controller such that the supply air and condenser water set temperatures reach the set points designated by the optimal supervisory controller. The influences of the controlled variables on the total system and component power consumption was determined. It is possible to minimize total energy consumption by selecting the optimal set temperatures through the trade-off among the component powers. The total system power is minimized at lower supply, higher chilled water, and lower condenser water set temperature conditions.

  • PDF

Pit를 이용한 건물 급기방식의 효용성 평가에 관한 사례 연구 (A Case Study on Effectiveness Assessment of Supply Air System Using Pit in Building)

  • 민준기
    • 한국지열·수열에너지학회논문집
    • /
    • 제13권2호
    • /
    • pp.16-21
    • /
    • 2017
  • In this study, the flow effect of warming and cooling in the air supply of a pit for air conditioning were evaluated in BS art museum. We simulated the flow temperature for a pit winter and summer seasons using computational fluid dynamics. Consequential, energy saving, energy saving costs and initial payback periods were calculated and the following conclusions were drawn. The warming effect of the winter increased by $18.1^{\circ}C$ and $0.2^{\circ}C/m$ and the cooling effect of the summer decreased by $6.1^{\circ}C$ and dropped to $0.07^{\circ}C/m$. Energy saving appeared to be 19.1 kW in the summer and 54.3 kW in winter. Energy saving costs ranged from 2,567,119 won/year to 5,134,238 won/year and at minimum, initial payback period for initial investment was 3.9 years. As a result, the air supply system using an existing pit without any burden on initial investment costs is believed to contribute to energy saving through warming and cooling of unutilized energy effects.

낮은 커플링 변압기를 갖는 비접촉 전원의 개선된 고효율 공진 컨버터 (An Improved High Efficiency Resonant Converter for the Contactless Power Supply with a Low Coupling Transformer)

  • 공영수;김은수;이현관
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권1호
    • /
    • pp.33-39
    • /
    • 2005
  • Comparing with the conventional transformer without the air gap, a contactless transformer with the large air gap between the long primary winding and the secondary winding has increased leakage inductance and reduced magnetizing inductance. For transferring the primary power to the secondary one, the high frequency series resonant converter has been widely used for the contactless power supply system with the large air gap and the increased leakage inductance of the contactless transformer However, the high frequency series resonant converter has the disadvantages of the low efficiency and high voltage gain characteristics in the overall load range due to the large air gap and the circulating magnetizing current. In this paper, the characteristics of the high efficiency and unit voltage gain are revealed in the proposed three-level series-parallel resonant converter. The results are verified on the simulation based on the theoretical analysis and the 5kW experimental prototype.

영구자석을 이용한 새로운 Suction Mechanism (New Suction Mechanism Using Permanent Magnet)

  • 서성근;이승희;박종현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.962-966
    • /
    • 2004
  • Suction transfer system with air suctioning is widely used and continuously developed in production automation. Air suctioning has some drawbacks in use. To generate vacuum in the suction cup with air suctioning, complex of mechanical component like as air compressor, air tube, air value is need, and it needs continuous air supply. And if the failure of the suction in a cup in the multi-suction cup system which is generally used occurs then the suctions of all of the cup will be fail. To overcome these drawbacks, new suction mechanism which uses permanent magnet for the movement of the suction cup is proposed. The proposed mechanism activates each suction cup separately, so the air leakage of a cup is not critical. The proposed suction system wasdesigned and fabricated in real world. With some experiments, the usability and performance of the suction mechanism was proved. The strong points of the proposed suction mechanism are simple structure, high energy efficiency, and discrete energy supply.

  • PDF

영구자석을 이용한 새로운 Suction Mechanism (New Suction Mechanism Using Permanent Magnet)

  • 서성근;이승희;박종현;장태사
    • 대한기계학회논문집A
    • /
    • 제29권12권
    • /
    • pp.1645-1652
    • /
    • 2005
  • Pick-and-place systems using suction cups have been being widely used and continuously developed in production automation. There are, however, some drawbacks in constructing such systems. One of them is that it generates high level noise due to air compressors. And the system must have complex constitutions of mechanical component such as air compressors, air tubes, air valves, etc. Moreover, it needs continuous air supply to maintain vacuum in suction cups. If there is a failure in any suction cup, the total suction system may fail owing to air leakage. To overcome these drawbacks, we propose PMS (Permanent Magnet Suction) mechanism which has permanent magnets for vacuuming suction cups with no air compressor. The basic concept of PMS mechanism is to rotate permanent magnets with fixed angle. Simple rotation of permanent magnets changes the direction of the magnetic force applied at the suction cups. Since each suction cup has no direct connection with any of the others, the air leakage at one suction cup is not critical. The proposed suction mechanism was designed and fabricated. With some experiments, the feasibility and performance of the PMS mechanism was shown. The strong points of the PMS mechanism are in its simple structure, generating low noise, high energy efficiency, and no need of continuous energy supply.

압전 액추에이터를 이용한 DMFC의 공기 공급 시스템 (Air Supplying System for DMFC using Piezo Actuators)

  • 홍철호;김동진;윤효진
    • 한국산학기술학회논문지
    • /
    • 제11권5호
    • /
    • pp.1585-1591
    • /
    • 2010
  • DMFC는 산소를 반응물질로 사용하기 때문에 캐소드 전극이 외부 공기와 직접 접촉해야 한다. 그러나 휴대기기에 사용하는 경우에 사용자의 신체에 의해 공기의 흡입구가 가려져 산소공급이 되지 않는 현상이 발생할 수 있다. DMFC에 공기를 공급하기 위해 냉각팬을 사용하는데 냉각팬은 유로의 압력 손실 및 변동에 따라 출력의 변동이 심하다. 본 논문에서는 냉각팬의 문제점을 해결하기 위해 압전 액추에이터를 이용하여 공기 공급 시스템을 설계하였다. 설계된 공기 공급 시스템의 성능을 평가하기 위해 DMFC 평가 시스템을 구현하였고, 구현된 시스템을 통해 MP3 플레이어를 동작 시켰다.

태양광발전을 이용한 에어콘의 보조운전 제어 시스템 (Auxiliary Power Supply using Photovoltaic Power Generation for Air-Conditioner)

  • 황인호;유권종;송진수;이후기;정찬규
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국태양에너지학회, 한국에너지공학회 1993년도 춘계 공동학술발표회 초록집
    • /
    • pp.47-52
    • /
    • 1993
  • Recently, as exactly clean source, the research of photovoltaic power generation is undertaken actively and widely. In this paper, an auxiliary power supply system which is composed of photovoltaic generation and DC-DC boost chopper is described. This system in mainly for Air-conditioner appliances is which AC source is formed through rectifying circuit and without electrical storage battery. There exist two operating modes depending on the power quantity of the solar cells and the load. The control algorithm is discussed.

  • PDF

대심도 지하역사 승강장 및 대합실 평상시/비상시 급·배기 풍량에 대한 실험적 연구 (Experimental Study for the Capacity of Ordinary and Emergency Ventilation System in Deeply Underground Subway Station)

  • 장용준;이호석;박덕신
    • 한국철도학회논문집
    • /
    • 제15권6호
    • /
    • pp.579-587
    • /
    • 2012
  • 서울 지하철 지하역사의 평상시 및 비상시(화재시)의 급배기 효율을 조사하기 위하여 대표적인 대심도역사인 신금호 역사를 선정하여 설계 용량 대비 실제 용량을 계측하여 비교분석 하였다. 신금호 역사는 심도가 43.6m(서울에서 3번째 깊이) 이며, 지하8층의 섬식 승강장과 지하 1,2층의 대합실로 이루어져 있다. 승강장과 대합실을 연결하는 통로는 1개의 비상계단을 사용하도록 되어있다. 실험을 위하여 열선유속계, capture hood, 풍향풍속계 및 데이터 수집장치 등을 이용하여 자동 계측하였다. 실험 결과 평상시 대합실에서는 급기량 및 배기량이 설계치에 비하여 실측치가 각각 34% 및 46% 감소된 환기량을 보였으며, 승강장에서는 급기량 및 배기량이 각각 66% 및 38% 감소된 환기량을 보였다. 비상시에서는 대합실에서 급기량이 42% 감소, 승강장에서는 배기량이 28% 감소된 것으로 조사되었다. 따라서 평상시에는 역사에서의 공기질 악화 및 비상시에는 제연능력 약화가 예상된다.

코안다 노즐을 이용한 배기가스 재순환 장치의 형상에 따른 재순환 유동 특성에 관한 연구 (A Study on the Recirculation Flow Characteristics with the Change of Shape in a Flue Gas Recirculation Device using Coanda Nozzle)

  • 하지수;심성훈;김대연
    • 한국가스학회지
    • /
    • 제23권3호
    • /
    • pp.1-6
    • /
    • 2019
  • 본 연구는 폐기물 소각로에서 질소산화물 저감을 위해 고온의 배기가스를 연소로에서 재순환하여 연소용 공기와 혼합하여 배기가스 재순환을 이용한 방법에서 고온의 배기가스를 별도의 동력 팬이 없이 코안다 노즐을 이용한 배기가스 재순환 장치에 관한 연구이다. 코안다 노즐에서 공기 공급 노즐 간극의 변화와 공기 공급 노즐의 위치에 따른 배기가스 재순환 유량 특성과 혼합 가스의 출구에서 평균온도 변화를 살펴보았다. 공기 공급 노즐의 간극이 3.22, 4.03, 4.84 mm로 변할 때 가장 좁은 3.22 mm일 때가 배기가스 재순환 유량과 공기 공급 유량의 비인 배기가스 재순환 유량비가 2.227로 가장 재순환 유량이 크게 나타났고 혼합가스 평균 온도는 $594.8^{\circ}C$로 나타났다. 공기 공급 노즐의 위치가 코안다 노즐 목의 전방 위치, 목 위치, 확관 위치로 변할 때를 살펴보았으며 전방 위치와 목 위치일 때는 재순환 유량비가 1.843으로 거의 같은 값이고 확관 위치에서는 1.696으로 나타났으며 평균 온도는 $559.8^{\circ}C$$544.3^{\circ}C$로 나타났다.