• Title/Summary/Keyword: Air Pollution, Indoor

Search Result 433, Processing Time 0.033 seconds

PM10 and CO2 Concentrations in the Seoul Subway Carriage (서울 지하철 객차 내 PM10과 CO2의 농도 변화)

  • Sohn, Hong-Ji;Ryu, Kyong-Nam;Im, Jong-Kwon;Jang, Kyung-Jo;Lee, Ki-Young
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.6
    • /
    • pp.454-460
    • /
    • 2009
  • The subway is the major public transportation system in Seoul with 2.2 million people using it everyday. Indoor air pollution in the subway can be a significant part of population exposure because of the number of people using the subway, time spent in transit and potentially high exposure for certain pollutants. The Korea Ministry of Environment has established the level 2 of recommended standards of $PM_{10}$ and $CO_2$ in subway trains. The aims of this study were to determine the airborne levels of $PM_{10}$, $CO_2$ and any correlation between pollutant levels and number of passenger in a subway train. The airborne $PM_{10}$ and $CO_2$ were measured on the inside of trains on line #4 for 4 different days from October to November in 2008. Average $PM_{10}$ and $CO_2$ levels were $113{\pm}25{\mu}g/m^3$ and $1402{\pm}442$ ppm, respectively. These levels did not exceed the level 2 of recommended standards of $250{\mu}g/m^3$ for $PM_{10}$ and 3500 ppm for $CO_2$. $PM_{10}$ level was not correlated with the number of passengers, while $CO_2$ levels were positively correlated with the number of passengers. The findings suggested that $PM_{10}$ in subway trains may have sources other than those directly associated with the number of passengers.

A Study of Environment Monitoring System based on USN (유비쿼터스 센서 네트워크 기반 환경 모니터링 시스템에 관한 연구)

  • Kim, Ki-Tae;Choi, Sam-Gil;Kim, Dong-Il
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.467-470
    • /
    • 2010
  • USN(Ubiquitous Sensor Network) is the network that widely applies for life of human being. It works out to sense, storage, process, deliver every kind of appliances and environmental information from the stucktags and sensors. And it is possible to utilize to measure and monitor about the place of environmental pollution which is difficult for human to install. It's studied constantly since it be able to compose easily more subminiature, low-power, low-cost than previous one. And also it spotlights an important field of study, graft the green IT and IT of which the environment and IT unite stragically onto the Network. This study realize a IAQM(Indoor Air Quality Management) sensing mechanism composition under the network and suggest the application of Environment monitoring system outlook to measure an Environment element.

  • PDF

Associations Between Indoor Air Pollutants and Risk Factors for Acute Respiratory Infection Symptoms in Children Under 5: An Analysis of Data From the Indonesia Demographic Health Survey

  • Ichtiarini Nurullita Santri;Yuniar Wardani;Yohane Vincent Abero Phiri;Gunchmaa Nyam;Tyas Aisyah Putri;Khoiriyah Isni;Dyah Suryani;Grace Sambo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.56 no.3
    • /
    • pp.255-263
    • /
    • 2023
  • Objectives: The study investigated the association between indoor air pollution (IAP) and risk factors for acute respiratory infection (ARI) symptoms in children under 5 years of age. Methods: A cross-sectional study was conducted using data derived from Indonesia Demographic and Health Survey in 2017. Binary logistic regression modeling was employed to examine each predictor variable associated with ARI among children under 5 years of age in Indonesia. Results: The study included a total of 4936 households with children. Among children under 5 years old, 7.2% reported ARI symptoms. The presence of ARI symptoms was significantly associated with the type of residence, wealth index, and father's smoking frequency, which were considered the sample's socio-demographic characteristics. In the final model, living in rural areas, having a high wealth index, the father's smoking frequency, and a low education level were all linked to ARI symptoms. Conclusions: The results revealed that households in rural areas had a substantially higher level of reported ARI symptoms among children under 5 years old. Furthermore, the father's smoking frequency and low education level were associated with ARI symptoms.

Flow Analysis indoor Coal Storage Shed due to Wind Velocity and Wind Direction of Ambient Air (외기의 풍속 및 풍향에 따른 옥내저탄장 내부 유동 해석)

  • Kim, Tae-Kwon;Cho, Mok-Lyang;Bae, Young-Wan;Kim, Ji-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.538-545
    • /
    • 2020
  • The outdoor coal storage sheds of thermal power plants are being converted to indoor coal storage sheds worldwide because of the environmental pollution problems in the surrounding areas. On the other hand, indoor coal storage sheds are causing problems, such as indoor coal scattering and harmful gas generation. In this study, the ventilation method of indoor coal storage sheds was analyzed in terms of the internal flow characteristics and ventilation according to the outside wind velocity and direction. CFD analysis was performed based on the actual flow measurement information inside the indoor coal storage sheds. A comparison of the wind speed of 6 m/s and 2 m/s when the outside wind direction was easterly showed that the stream velocity to the monitor louver was faster and the recirculation area was clearer at 6 m/s than at 2 m/s. In addition, the trend of a westerly wind was similar to that of the easterly wind. The ventilation rate according to the wind speed was 13.1 times and 4.4 times for a wind speed of 6 m/s and 2 m/s, respectively. If the wind speed is 2 m/s, the situation does not meet the required number of ventilations per hour in a general plant, and needs to be improved.

A Case Study on Distribution Characteristics of Indoor and Outdoor Particulate Matter (PM10, PM2.5) and Black Carbon (BC) by Season and Time of the Day in Apartments (아파트 실내·외 미세먼지(PM10, PM2.5)와 블랙카본(Black Carbon)의 계절별 농도 및 시간대별 분포 특성 사례연구)

  • Park, Shinyoung;Yoon, Danki;Kong, Hyegwan;Kang, Sanghyeon;Lee, Cheolmin
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.4
    • /
    • pp.339-355
    • /
    • 2021
  • Background: Particulate matter (PM10, PM2.5) and black carbon contribute to poor air quality in urban areas, and can also affect indoor environments. Exposure to PM can be associated with respiratory and lung diseases. Objectives: This study investigated the indoor and outdoor concentration distribution patterns of PM10, PM2.5, and black carbon at an apartment building, a typical residential space in the metropolitan areas of South Korea, by season, day of the week (weekday vs. weekend), and time of the day. It aims to obtain foundational data for the effective management of pollutants and investigate the difference in pollution levels between indoor and outdoor environments. Methods: Indoor and outdoor concentrations of PM and black carbon were measured at an apartment building located in Namyangju, Gyeonggi-do Province, using dust sensors and an Aethalometer AE51 (AethLabs, San Francisco, CA, USA) over the course of a year from June 2020 to May 2021. The concentration distribution patterns were analyzed by season and time of day. Results: PM10 and PM2.5 concentrations in the outdoor environment were higher than those in the indoor environment, regardless of the season. By contrast, the indoor black carbon concentration was higher than that in the outdoor environment during summer and autumn. The concentrations of PM10, PM2.5 and black carbon were found to be higher on weekdays than during weekends, especially during rush hour, with concentrations of 25.92~56.58 ㎍/m3, 21.12~44.82 ㎍/m3, 0.63~3.40 ㎍/m3. Conclusions: The outdoor concentrations of PM10, PM2.5, and black carbon were higher during the weekdays, especially during rush hour, than during weekends. This study is expected to provide basic data for the health management of apartment occupants because it is measured over a period of more than one year.

Photooxidation Reaction of Toluene/$NO_x$ Mixture in an Indoor Smog Chamber (실내 스모그 챔버를 이용한 톨루엔/$NO_x$ 광화학 반응 현상의 관찰)

  • 이영미;이승복;배귀남;김민철;문길주;박주연;김용표
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.05b
    • /
    • pp.167-168
    • /
    • 2003
  • 광화학 스모그는 대기 중으로 배출된 일차 오염물질인 /NO$_{x}$와 휘발성 유기화합물(volatile organic compounds)이 햇빛에 의해 반응하여 오존과 그외 다른 광화학 물질들을(photochemical oxidants) 생성시키는 현상이다. 서울의 경우 이런 VOCs 중에서 가장 많은 양을 차지하는 톨루엔은 광화학 반응을 통해 이차 유기 에어로졸(secondary organic aerosols)을 생성하는 능력이 매우 높은 방향족 화합물이다(Na and Kim, 2001). 지금까지 톨루엔의 이차 유기 에어로졸 생성에 관한 연구와 다른 방향족 탄화수소에 관한 연구가 스모그 챔버 실험을 통해 많이 이루어져 왔다. (중략)

  • PDF

Characteristics of Formation and Growth of Aerosol Particles in an Indoor Smog Chamber (스모그 챔버 실험에 의한 에어로졸의 생성과 성장 현상의 관찰)

  • 김민철;배귀남;이승복;진현철;문길주;박주연;김용표
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.05b
    • /
    • pp.43-44
    • /
    • 2003
  • 스모그 챔버는 대기화학 반응을 물리적 변수를 제어할 수 있는 공간 내에서 재현하여 스모그 현상을 체계적으로 규명하기 위해 가장 많이 사용되는 방법이다(Dodge, 2000). 대기화학 반응을 통해 생성된 입자상 물질(secondary particles) 또는 초미세 입자(ultrafine particle, 〈0.1 $\mu\textrm{m}$)는 연속된 물리화학 반응을 통해 accumulation mode(0.1~l.0 $\mu\textrm{m}$) 입자로 성장한다. 특히, 대도시의 시정(visibility)은 accumulation mode 입자의 산란(scattering)과 흡수(adsorption)가 주요한 원인이기 때문에 이러한 물질의 생성에 영향을 주는 가스상 물질의 전화(gas-to-particle conversion) 반응과 초미세 입자의 성장 현상을 규명하는 것은 매우 중요하다. (중략)

  • PDF

Indoor radon concentrations in house and public buildings (국내 가옥 및 공공건물내 라돈농도)

  • 김창규;김용재;이재성;노병환
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.05b
    • /
    • pp.67-68
    • /
    • 2003
  • 라돈은 일반적으로 가장 잘 알려진 천연 방사성핵종 중 하나로서 무향 무색의 불활성기체이며 붕괴과정에서 알파입자를 방출한다. 라돈에 의한 피폭선량은 라돈붕괴에 의해 생성된 라돈자손이 호흡기관 표면에 침착되어 방출하는 알파선에 기인한다. 따라서, 피폭선량에 주로 기인하는 것은 라돈 자신이 아니라 그의 단 반감기 라돈자손들이다. 이처럼 라돈은 잘 알려진 폐암 유발원으로서 고농도의 라돈에 장기간 노출되는 경우 폐암을 유발할 수 있다. UNSCEAR 보고서(1993)는 자연 환경중에서 인간이 받는 연간 총 피폭선량인 2.4 mSv중 약 50%에 해당하는 1.15 mSv가 라돈과 그 자손에 의한 것이며 대부분 옥내에서의 호흡에 의해 비롯된다고 평가하고 있다. (중략)

  • PDF

Photocatalytic Reaction of VOCs Using Titanium Oxide (산화티타늄을 이용한 VOCs의 광촉매 반응)

  • Jung, Soo-Kyung
    • Journal of Environmental Science International
    • /
    • v.17 no.2
    • /
    • pp.171-176
    • /
    • 2008
  • The VOCs have a direct influence on indoor air pollution, and stimulate respiratory organs and eyes in human body. Also, most of VOCs are a carcinogenic substances and causes to SBS (sickness building syndrome). Therefore, this study was progressed in photocatalysis of VOCs using UV/$TiO_2$ which was a benign process environmentally. The experiments were performed to know photodegradation characteristics as crystalline structure of $TiO_2$ which had anatase, rutile and P-25 (anatase : rutile = 70 : 30). The main purpose of this study was to identify photocatalytic characteristics as inlet concentration of reactants, $H_2O$, and residence time.