• 제목/요약/키워드: Air Environment Index

Search Result 284, Processing Time 0.029 seconds

Study on Environmental Monitoring in Stack Room for Paper Storage Using the Preservation Index (보존 환경 평가 지수를 이용한 종이 보존 서고 환경 모니터링 연구)

  • Shin, Hyun-Chang;Yoon, Man-Young
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.29 no.1
    • /
    • pp.61-74
    • /
    • 2011
  • Critical environmental elements for long term preservation of a paper are temperature, humidity, dust, light, contaminants in air, and mold. Especially, temperature and humidity need special care, because they can not only directly degrade paper but also affect the degradation of the other elements. Therefore methods to monitor variation of temperature and relative humidity were studied. One of the methods was to use preservation index for evaluating preservation environment. Since the evaluation for preservation environment of a stack room investigated firstly by D. K. Sebera, PI(preservation index) and TWPI(Time-Weighted Preservation Index) by IPI is made to evaluate relatively preservation environment in a stack room. T. Padfield developed method which could calculate easy PI and TWPI. In this study, the preservation environment of stack rooms for paper storage in NAK(National Archives Korea) was evaluated by PI and TWPI. PI and TWPI of stack rooms for paper storage in NAK maintained good condition but PI depended on season. Then the preservation environment of stack rooms for paper storage in NAK was required to maintain continuously PI and TWPI regardless of season change.

Computer Simulation on the Thermal Environment by the Diffusion temperature and Diffusion Angle of Ceiling Type Air Conditioner in Classroom (교실에서의 천장형 냉난방기의 취출온도 및 취출각도에 따른 열환경 시뮬레이션)

  • Park, Hyo-Soon;Park, Seung-Ik;Lee, Sang-Hyeok;Lee, Kam-Gyu
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.4 no.4
    • /
    • pp.1-18
    • /
    • 2004
  • Research has been carried out to study thermal environment in a classroom under three kinds of air diffusion temperature and six kinds of air diffusion direction for ceiling type air conditioner. The velocity and temperature distributions of air in the room calculated by 3-dimensional numerical method(PHOENICS), This present study was also conducted to calculate the Air Diffusion Performance Index(ADPI) for cooling conditions and Predicted Percentage of Dissatisfied(PPD) for heating conditions. This analysis shows that the optimum angle of ceiling type air conditioner's diffusion is $15{\sim}30^{\circ}$ for cooling mode and about $15{\sim}45^{\circ}$ for heating mode in these calculating conditions. And also analysis has been carried out to evaluate thermal comfort of vertical and horizontal cross section of classroom.

  • PDF

Effects of Air Pollution on Pinus thunbergii in Yocheon Industrial Comples (麗川工業 地의 大氣汚染이 곰솔에 미치는 影響)

  • 김태욱;이경재;김준선
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.1 no.1
    • /
    • pp.25-32
    • /
    • 1985
  • To examine the effects of air pollution on Pinus thunbergii growing around Yocheon Industrial Complex, evaluation of visible injury based on Injury Index and chemical analysis of water-soluble sulfur and fluorine contents in needles were carried out on 30 sampling sites. Histological responses of needles were also investigated on the necrotic needle tissues. Not only Injury Index but water-soluble sulfur and fluorine contents were higher at all sites than those at control site, and showed significant correlationship among them. Especially, they were rather higher in the vicinity of air pollutants sources. Water-soluble sulfur contents were positively correlated with average atomospheric $SO_3$ concentrations. Microscopic examination of necrotic needle tissues showed that mesophyll cells were collapsed with hypertrophy and collapse of transfusion cells.

  • PDF

Development of IAQ Index for Indoor Air Quality in City Buses (시내버스 실내공기질 IAQ 종합지수 개발)

  • Jeon, Bo-Il;Kwak, Min-Jeong;Kang, Sang-Hyeon;Kim, Jong-Cheol;Yun, Hyun-Jun;Kim, Ho-Hyun
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.4
    • /
    • pp.444-456
    • /
    • 2020
  • Objectives: This study developed an index for the indoor air quality management of city buses to allow the provision of indoor air quality information to city bus users. Methods: Nine city buses in Seoul were measured for PM10, PM2.5, CO2, temperature, and relative humidity through IoT sensors. Big data collected through the sensors was analyzed to identify indoor air quality on city buses and graded through the index. Results: As a result of dividing the measured city bus data into five grades through the IAQ index, PM10 was rated "good" for 30.4% of the total measured values, and 9.2% were rated "risky". For PM2.5, 67.7 percent were rated "good" and 0.4 percent were rated "risky". For CO2, 0.9% were 'good' and 1.1% were 'risky'. The results of the classification through the IAQ index for city buses showed that the impact of good, normal, sensitive, bad, and dangerous were 2.7, 38.8, 46.0, 12.4, and 0.1%, respectively. According to the analysis by measurement area, Seocho-gu, Gangnam-gu, Seongdong-gu, Gwangjin-gu, and Dobong-gu are "normal" and other areas (Seodaemoon-gu, Jongno-gu, Yongsan-gu, Jung-gu, Seongbuk-gu, Dongdaemun-gu, Junggye-gu, Gangbuk-gu, and Nowon-gu) are all rated "sensitive". Conclusions: When analyzing cases where PM10 and CO2 indices are in the "bad" zone, the concentration is generally found to increase during rush hour, during which there are a large number of passengers. It is expected that indoor air quality management in vehicles will be necessary during rush hour.

Air Quality Deterioration in a Pristine Area due to a Petroleum Refinery and Associated Activities

  • Handique, Devolakshi;Bhattacharyya, Krishna G.
    • Asian Journal of Atmospheric Environment
    • /
    • v.11 no.4
    • /
    • pp.254-269
    • /
    • 2017
  • The work describes an assessment of the major air pollutants, $NO_2$, $SO_2$, CO, $O_3$, $NH_3$, coarse and fine particulate matter ($PM_{10}$, $PM_{2.5}$) in ambient air in and around a 3 million tonne Petroleum Refinery and the possible impacts on a pristine area marked by the presence of the world-famous Kajiranga National Park, a world heritage site and habitat for the most number of one-horned rhinos in the world. The Refinery is at an aerial distance of 20-25 km from the wildlife habitat. The assessment is based on regular monitoring at four stations around the Refinery and one station near the National Park. Heavy rains during June to August influence the pollutant concentrations while at other times of the year, large traffic volume adds to the pollutant concentrations that peak during November to March, the dry months of the year. Correlation analysis by scatter technique is utilised to obtain the enhancement ratios to predict the variations in the concentrations of the pollutants and their spatial distribution. Computation of air quality index (AQI) indicates that the coarse and the fine particulates in the ambient air could be a major hazard to wildlife in the area.

A Study on Evaluation of Thermal Environment using Heat Stress Indices for Deep Coal Mine in Korea (열적지표를 적용한 국내 고심도 석탄광산의 열환경 평가 연구)

  • Park, Seon-Oh;Roh, Jang-Hoon;Kim, Jin
    • Tunnel and Underground Space
    • /
    • v.24 no.2
    • /
    • pp.166-175
    • /
    • 2014
  • In this study, the thermal environment in a large scale coal mine located in Taebaek, Gangwondo was assessed by a field survey. In order to estimate the thermal environment, various heat stress indices such as WBGT, HSI, ESI, KATA index and effective temperature were investigated. Correlation analysis was also conducted. It was found that the thermal environment in most workplace was high. In particular, the correlation coefficient between HSI reflected in physiological fatigue characteristic and the maximum sweat evaporation heat was -0.834. This shows that the correlation coefficient have the most influence on HSI index. The factor which has the most influence on the maximum sweat evaporation heat is velocity of air. The thermal environment of high-depth coal mines is likely to be improved by installing a structure that enables the maximum prevention of extended digging, air doors, or the leakage of the inflow of air in the first shaft.

Internal Thermal Environment Uniformity Analysis of Mechanically Ventilated Broiler House (강제 환기식 육계사 내부 열환경 균일성 평가)

  • Kim, Da-in;Lee, In-bok;Lee, Sang-yeon;Park, Sejun;Kim, Jun-gyu;Cho, Jeong-hwa;Jeong, Hyo-hyeog;Kang, Sol-moe;Jeong, Deuk-young
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.64 no.6
    • /
    • pp.65-75
    • /
    • 2022
  • Livestock industry in Korea has been growing rapidly and has reached 23 trillion Korean won in 2021. This study focuses on broiler, which is one of the largest sectors in livestock industry. As the effects of climate change get more serious, primary industry such as livestock industry is fragile to climate change since it directly interacts with nature. Therefore, maintaining suitable rearing environment is important. One of the most frequently used ventilation type for controlling the rearing environment of broiler house, tunnel ventilation, causes frequent air velocity fluctuation which makes maintaining the rearing environment important. By measuring the air temperature, relative humidity and air velocity in various points inside the broiler house, the internal thermal environment uniformity was analyzed according to length, width and zone. The experimental house was found to have dead zone with high air temperature, relative humidity and low air velocity near the end of the inlet and at the end of the broiler house. By using heat stress index to analyze quantitatively, zone with highest heat stress index was found to increase by 7.55% compared to the lowest zone. As a result, to maintain uniform rearing environment inside the broiler house, different factors must be measured and analyzed and used to operate the environmental control facilities.

A Study on the Lubricating Air-layer Detection Techniques with Digital Image Analysis in Flat Plate Air Lubrication Test (공기윤활평판실험에서 디지털 영상분석을 통한 윤활공기막 검출기법)

  • Park, SeongHyeon;Lee, Inwon
    • Journal of the Korean Society of Visualization
    • /
    • v.14 no.1
    • /
    • pp.27-32
    • /
    • 2016
  • The reduction of $CO_2$ emissions has been a key target in the Marine Industry since the IMO's Marine Environment Protection Committee published its findings in 2009. The representative emission index is termed as the EEDI (Energy Efficiency Design Index) for the new ships. Among various flow control techniques ever proposed, the air lubrication method is the one of most promising one in terms of practical applicability. The present study examines the basic characteristics of the flat plate test with intention of applying the air lubrication technology to the reduction of the resistance of a ship. Image analysis technique is proposed as a tool to quantify the effectiveness of the air lubrication method.

Estimation of Air Pollution by Distribution of Epiphytic Bryophtes in Chonnam Area (선태식물을 이용한 전남지역 대기오염도 평가)

  • Yang, Soo-In;Ha, Hoon;Rim, Hang-Seon;Park, Chan-Ok;Hong, Suk-Soon;Jeong, Beung-Seuk
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.11 no.2
    • /
    • pp.137-144
    • /
    • 1995
  • The I.A.P.(Index of Atmospheric Purity) by the distribution of Bryophtes on the bark of various latifoliate tree trunks was investigated at four sites(Daeheung, Songkwang, Jeungsim, and Heunggook Temple) from April, 1991 to April, 1993. The IAP was in inverse proportion to the degree of air pollution. The I.A.P at four sites were estimated 78.2 at Daeheung temple, 61.0 at Songkwang temple, 28.3 at Jeungsim temple, and 10.3 at Heunggook temple, respectively. The distribution degree of Bryophytes in Heunggook temple progressed during the last ten years. It represents the bettrment of air quality. Bioassay by means of lichens seems to have great potential for better and less expensive ways of measuring pollution levels instead of the high cost of buying and maintaining air pollution monitoring equipment.

  • PDF