• Title/Summary/Keyword: Air Distributor

Search Result 43, Processing Time 0.027 seconds

The Development for Localizing KTX Brake Devices and Performance Test (KTX 제동장치의 국산화 개발과 성능시험)

  • So, Jin-Sub;Lee, Seung-Gu;Hwang, Sang-Kyu;Keum, Jong-Ho;Kwak, Soo-Tae;Kim, Jong-Ryeol
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.630-636
    • /
    • 2011
  • Air brake system of KTX effectively distributes air to brake panel in each bogie. System consists of carrying bogie brake panel, motor bogie brake panel, driver's valve panel, pneumatic auxiliary panel and other accessories. For the prove endurance, confirm test number. Distributor and control moderable magnet valve are 500,000 times and respectively, carrying bogie MR/BP cut-out cock are 12,000 times. Tests satisfy all of condition until now. Developments conduct a performance test to brake tester of domestic manufacturer and operating authority.

  • PDF

Study on the Fluidized Bed Drying of Grains (1) - Fluidization charcteristics of Rough Rice - (곡류의 유동층 건조에 관한 연구 (1))

  • Hur, Jong-Wha;Suh, Gil-Duk
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.13 no.3
    • /
    • pp.168-182
    • /
    • 1984
  • For the purpose of drying high moisture rough rice effectively, from the view point of pre-drying, some basic experiments of fluidized bed drying of rough rice were carried out. The minimum fluidization velocities $(U_{mf})$ for both rough rice and glass bead were analyzed to find out fluidizing characteristics. The main results obtained were as follows ; 1) Minimum fluidization velocity of rough rice and glass bead were 2.01m/s and 4.07m/s, respectively, when using the distributor with $16\%$ opening ratio. 2) $U_{mf}$ calculated by Shirai's empirical equation and that calculated by Wen's modified equation were inconsistent with experimental data, while $U_{mf}$ calculated by Ergun's equation was consistent with the experimental data. 3) The following equations, on the basis of Leva's equation, were obtained. $$C_{mf}=1.19\times10^{-4}(Re_p)^{-0.0318)\;(rough rice)$$ $$C_{mf}=1.02imes10^{-4}(Re_p)^{-0.0047)\;(glass bead)$$

  • PDF

A Study on the Transmitted Noise Characteristics through the Ventilating Duct (환기용 덕트내의 전달소음 특성에 관한 연구)

  • Choi, Han-Lim;Kim, Kyung-Whan;Choi, Ho-Seon;Oh, Sai-Kee;Chung, Baek-Young
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.376-380
    • /
    • 2009
  • The transmission noise characteristics through the ventilating duct was conducted numerically using SYSNOISE. A ventilating system is usually composed of mufflers for preventing noise transmission from the ventilator into indoors through the ducts and distributors for transferring air to or from each room. The transmitted noise characteristics of distributors which have different branch angles and of mufflers having different shapes were analyzed numerically. New duct element combining a muffler and a T-shaped distributor was developed for better noise reduction in this paper. New element's performance was shown numerically.

  • PDF

The Effective Factors of n Foam Generation Using Foam Condensate (포말 농축물에 의한 포말 생성의 영향인자)

  • SUH Kuen-Hack;SHIN Jeong-Sik;LEE Ju-Hwa
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.36 no.5
    • /
    • pp.509-514
    • /
    • 2003
  • We performed the experiment to determine the effective factors, such as the initial concentration of protein, pore size of air distributor, SAV (superficial air velocity), pH, salts and temperature related to foaming characteristics. The foam height in a foam generator was increased with the increase of the initial protein concentration and the decrease of pore size. As SAV was increased, the foam height was increased, and the optimum SAV was 0.84 cm/sec. The foam height was highest in the acid region and it was increased with the increase of salt concentration of NaCl and $NaHCO_3.$ The removal efficiencies of TSS (total suspended solid) and turbidity decreased with the increase of the initial protein concentration in the batch foam separator.

Adjustment of Valve Opening in Ondol Hot Water Distributor (온돌 난방분배기의 개도조정)

  • Hong, Hi-Ki;Kim, Si-Hwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.7
    • /
    • pp.460-467
    • /
    • 2010
  • In housing units constructed recently in Korea, the length of ondol coil is different in each room, so the flow rate of hot water is adjusted by setting valve opening. If the flow rate is not appropriate for heating load, the room temperature seriously deviates from the set temperature range for comfort. In particular, too small valve opening can induce a noise by cavitation. In order to adjust the valve opening, two methods by zone area and a new method by return temperature rise were modelled and simulated using TRNSYS and EES. As a result, heating energy consumption during one week was the same on three methods, but the room temperature of the new method minimally deviated from the range of set temperature with a low possibility of noise.

A Study of Flow Characteristics through the Speed Control and Flow Resistance (유로저항에따른 속도제어를 통한 Zone별 유량특성 연구)

  • Oh, Byung-Kil;Kim, Hway-Suh
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.11
    • /
    • pp.762-768
    • /
    • 2011
  • We use floor radiant heating system in the house of commons in winter Floor radiant heating system, which transfer heat by radiation, is one of the energy efficient and comfortable systems that. Floor radiant heating system is configured to be controlled by the room for energy-saving. Proper flow rate to a comfortable heating in the room is important. However, Using a constant speed circulation pump in separate rooms, heating system may cause an imbalance because of the difference of length of coil when operating in the rooms. In this study, our Research team examined heating imbalance due to the variation length through the coil length changes and flow control of the circulation pump.

Analyzing for Refrigerant Induced Noise for Split type Air Conditioner Indoor Unit (분리형 에어컨의 실내기 냉매 소음 저감 분석)

  • Han, Hyung-Suk;Aoyama, Shingeo;Mo, Jin-Yong;Lee, Jae-Kwon;Song, Yong-Jae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.421-426
    • /
    • 2005
  • For the air-conditioner, refrigerant induced noise and vibration should be the problem when it reduced airflow rate in order to reduce the noise at low mode. With the test, it could be verified that one of the main reason for refrigerant induced noise were the velocity and flowing induced force of the refrigerant at the inlet of evaporator. So in order to reduce this velocity with same mass flow rate of refrigerant, quality at the evaporator inlet should be minimized. And in order to reduce flowing induced force of the refrigerant, flowing direction change should be eliminated. So in this paper, it would like to review the characteristics of refrigerating cycle at first and find how the quality and flowing induced force can be minimized.

  • PDF

Analyzing for Refrigerant Induced Noise for Split Type Air Conditioner Indoor Unit (분리형 에어컨의 실내기 냉매 소음 저감 분석)

  • Aoyama Shigeo;Mo, Jin-Yong;Lee, Jae-Kwon;Song, Yong-Jae;Han, Hyung-Suk
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.3 s.108
    • /
    • pp.240-246
    • /
    • 2006
  • In the air-conditioner, refrigerant induced noise and vibration can be increased when the airflow rate is reduced in order to decrease the noise at the low mode. Through the test and analysis of this kind of noise, it can be verified that the main reasons of refrigerant induced noise are the velocity and flow Induced force of the refrigerant at the inlet of the evaporator, So, in order to reduce this velocity, quality at the evaporator inlet should be minimized. And, in order to reduce flow induced force of the refrigerant, sudden change of fluid flow must not be occurred. So, in this paper, we will review the characteristics of refrigerant cycle and find how the quality and flow induced force can be minimized.

Characteristics of Foam Generation in Freshwater and Seawater (담수와 해수에서의 포말 생성 특성)

  • SHIN Jeong-Sik;KIM Byong-Jin;SUH Kuen-Hack
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.37 no.3
    • /
    • pp.179-185
    • /
    • 2004
  • The characteristics of foam generation were assessed for freshwater and seawater using a foam generator. Both in freshwater and seawater, the height of the foam layer increased with initial protein concentrations. The height of the foam layer also increased with pore size of the air distributor. The optimum superficial air velocities (SAV) in freshwater and seawater were 0.84 cm/sec and 0.6 cm/sec, respectively. The height of the foam layer was the highest in pH 3 in freshwater and in the region of pH 5-7 in seawater. The height of the foam layer increased with $NaHCO_3$ concentration in freshwater, and $NaHCO_3$ concentration had little effect in seawater. Removal efficiencies of total suspended solid (TSS) and turbidity decreased with an increase of initial protein concentrations in a batch foam separator both in freshwater and seawater.

Development of Three-Way Proportional Control Valve and Performance Study (3방 비례제어 조절밸브 개발 및 성능 연구)

  • Lee, Jonghwa;Jung, Taeksu;Cho, Chongdu;Kim, Jooyong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.5
    • /
    • pp.218-223
    • /
    • 2014
  • Korea District heating corp. recently give an attention to combine the district heating and supply pipes as a two pipe system that are in the present system separated with room heating and warm water supply pipe, and the two pipe system is commonly applied for heating service in European countries. In the new two pipe system, only one heat source is supplied to a house and partitioned into room heating and warm water supply by household substation. So the effective distribution of supplied heat source in accordance to user intention is very important. This paper presents the development and performance test of three-way proportional control valve for a combined heat source system in district heating. The proposed valve is controlled to partition heat source into two different directions : hot water distributor for space heating and household substation for warm water supply in response to the pressure drops of tap water caused by the user. The performance investigation is shown within 3% of error compared to the theoretical model of the three-way proportional valve and its controllability is verified.