• Title/Summary/Keyword: Air Control

Search Result 5,848, Processing Time 0.032 seconds

Common-Mode Current Reduction with Synchronized PWM Strategy in Two-Inverter Air-Conditioning Systems

  • Baek, Youngjin;Park, Gwigeun;Park, Dongmin;Cha, Honnyong;Kim, Heung-Geun
    • Journal of Power Electronics
    • /
    • v.19 no.6
    • /
    • pp.1582-1590
    • /
    • 2019
  • A new method for reducing the common-mode current generated by the voltage variations in a two-inverter air conditioner system by applying a synchronized pulse-width modulation (PWM) strategy is proposed. The PWM signals of the master-mode inverter are generated based on the reference voltage, while those of the slave-mode inverter are output in the opposite direction when the master-mode inverter changes its switching state. However, the slave-mode control results in a mismatch between the reference voltage and the actual output voltage that is modified by synchronized control operation. The proposed method is capable of reducing and controlling this voltage error by performing signal selection in the vector space of the slave-mode inverter, which mitigates the distortion of the phase current. The efficacy of this method in reducing conducted emissions has been validated both theoretically and experimentally.

The Study on the Direction of Developing an Aerodrome Traffic Control Simulator for the Air Traffic Controller (항공교통관제사를 위한 국내 비행장 관제시뮬레이터 구현 방향의 연구)

  • Hong, Seung-Beom;Kim, DoHyun
    • Journal of Advanced Navigation Technology
    • /
    • v.18 no.2
    • /
    • pp.114-120
    • /
    • 2014
  • In this paper, we reviews the need and contents of aerodrome control simulator for air traffic controllers' training. In the view of managing the aviation safety, the departure and landing phases of aircraft are very important, because more than 60% of aircraft accidents and incidents have occurred in the take-off and landing phases. According to the benchmark each as practice type, simulation device and fidelity of reality of the air traffic control simulator, we have evaluated the implementation level of the domestic air traffic control simulator and checked up the current simulator's problems through the air traffic controllers' survey. Therefore, we suggest to the direction of developing a HI-FI simulator for aerodrome controllers.

Effect of Occupants' Active Behaviour of Environmental Control on Indoor Environment in Summer's High School Classroom (하절기 고등학교 교실에서 재실자의 적극적 환경조절행동이 실내환경에 미치는 영향)

  • Kwak, Ro-Yeul
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.5
    • /
    • pp.181-190
    • /
    • 2019
  • In high school classrooms, it is reported that ventilation is often insufficient, increasing health risks among students. Therefore, indoor air quality in school classrooms is very important in terms of students' health and learning abilities. In this study, the effect of window opening, which is a control mechanism for air control in summer high school classrooms, on the change in air and indoor environment of the classroom was analyzed and physical conditions of indoor and air environment were observed during the classroom course, and satisfaction of the students and teachers was assessed with questionnaires. It was found that change rate of $CO_2$ concentration in classroom was effectively reduced by carrying out activity of opening the window by active environment control activity of occupants at break time, intermission time and cleaning time. And optimal window opening by students was presented to prevent unpleasantness and degradation of indoor air quality and the effects were analyzed.

Development of Inverter Controlled Air Pressure Type Water-Supply and Determination of Optimal Operation Pressure (무접점 공기압력식 급수시스템 개발 및 최적운전점 결정)

  • Kim, Jung-Hoon;Kim, Hak-Bong
    • Proceedings of the KIEE Conference
    • /
    • 1994.11a
    • /
    • pp.181-183
    • /
    • 1994
  • This paper presented the developments and operations of control system for Inverter-controlled air pressure type water-supply systems. The developed controller that enables regular speed and variable speed. In addition, an air supplement control system was developed to establish a utility model of water supply facility system as well as a method to optimize its operation.

  • PDF

Effect of Air Circulation in Greenhouse on Development of Fermented Fruits in Oriental Melon (시설내 공기순환이 참외 발효과 발생에 미치는 영향)

  • 신용습;연일권;배수곤;최성국;최부술
    • Journal of Bio-Environment Control
    • /
    • v.10 no.1
    • /
    • pp.23-29
    • /
    • 2001
  • This experiment was conducted to investigate to investigate the effect of air circulation and forced ventilation of greenhouse on the development of fermented fruits in an oriental melon. An air circulation system and a forced ventilation system were operated during 09:30~17:00 at a 15 min. interval from Apr. 6, 5 days after fruit setting, to Jun. 29, everyday except rainy days. Wind velocities in the greenhouse were 0.06~0.08, 0.24~0.32, and 0.60~0.72m.s$^{-1}$ in the naturally ventilated (control), in the air circulated, and including leaf length and width, were observed between treatments. However, the amount of xylem exudate increased in the air circulated treatment as compared to the control. Percent of fermented fruits significantly decreased in the air circulated treatment as compared to the control. The forced ventilation treatment showed no significant difference in percent of fermented fruits as compared to the control or to the air circulated treatment.

  • PDF

Emission Reduction of Air Pollutants Produced from Chemical Plants

  • Lee, Byeong-Kyu;Cho, Sung-Woong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.E
    • /
    • pp.29-38
    • /
    • 1999
  • This study identified emission sources and emissions of air pollutants such as volatile organic compounds (VOCs), solvents, and acid gases produced from chemical plants. We collected air samples from various processes, reactors and facilities using VOC detectors and workers' experience. We identified chemical structures and emission concentrations of air pollutants. We analyzed total emissions of air pollutants emitted from the chemical plants. Also, we developed some emission reduction technologies based on chemical types and emission situations of the identified air pollutants. For reduction of air emissions of acid gases, we employed a method improving solubility of pollutants by reducing scrubber operation temperature, increasing surface area for effective contact of gas and liquid, and modifying or changing chemicals used in the acid scrubbers. In order to reduce air emissions of both amines and acid gases, which have had different emission sources each other but treated by one scrubber, we first could separate gas components. And then different control techniques based on components of pollutants were applied to the emission sources. That is, we first applied condensation and then acid scrubbing method using H2SO4 solution for amine treatment. However, we only used an acid scrubbing method using H2O and NaOH solution for acid gas treatment. In order to reduce air emissions of solvents such as dimethylformamide and toluene, we applied condensation and activated carbon adsorption. In order to reduce air emissions of mixture gases containing acid gases and slovents, which could not be separated in the processes, we employed a combination of various air pollution control devices. That is, the mixture gases were passed into the first condenser, the acid scrubber, the second condenser, and the activated carbon adsorption tower in sequence. In addition, for improvement of condensation efficiency of VOCs, we changed the type of the condensers attached in the reactors as a control device modification. Finally, we could successfully reduce air emissions of pollutants produced from various chenmical processes or facilities by use of proper control methods according to the types and specific emission situations of pollutants.

  • PDF

Precise temperature control by modern control method on the refrigerator and air conditioner (현대제어 이론을 이용한 냉동공조기의 정밀 온도제어)

  • 한정만;유휘룡;김상봉
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.1213-1216
    • /
    • 1996
  • This paper describes a precise temperature control method for refrigerating and air conditioning systems. The control technique is based on the optimal servo control design method and the control algorithm is implemented on a personal computer. To control the precise temperature, two actuators such as an inverter for the compressor speed control and a stepping motor for regulating the expansion valve are used. The superheat and evaporator temperatures are chosen as the system output. So a multivariable system which has two inputs and two outputs to be controlled. The complicative model is identified by using an ARX(Auto Regressive eXogenous) model and the controller is designed by using the Matlab software.

  • PDF

A Study on Aircraft Flight Stability of T-50 Air Data Reconfiguration Mode (T-50 형상 재구성 모드의 항공기 비행 안정성에 관한 연구)

  • Kim, Chong-Sup;Hwang, Byung-Moom;Hwang, Min-Hwan;Bae, Myung-Whan
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.5
    • /
    • pp.57-64
    • /
    • 2005
  • Modern versions of supersonic jet fighter aircraft using digital flight-by-wire flight control system receive aircraft flight condition such as altitude, airspeed and AoA(angle of attack) from IMFP(Integrated Multi-Function Probe). IMFP sensors data have triplex structure using three IMFP sensors. An air data reconfiguration mode is applied to a T-50 flight control law to guarantee the aircraft flight stability when 2 or 3 IMFP sensors data are invalided. In this study, linear analysis and HQS(Handling Quality Simulator) pilot simulation are performed to analyze flight stability when the air data reconfiguration mode is applied to the control law. And we propose an example that the air data reconfiguration mode is applied to the control law due to second failure of IMFP during T-50 flight. It is found that the aircraft flight stability is not affected when the T-50 flight control law is changed to the air data reconfiguration mode.

Air System Modeling for State Estimation of a Diesel Engine with Consideration of Dynamic Characteristics (동적특성을 고려한 디젤엔진 흡배기 시스템의 상태추정 모델)

  • Lee, Joowon;Park, Yeongseop;Sunwoo, Myoungho
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.4
    • /
    • pp.36-45
    • /
    • 2014
  • Model based control methods are widely used to improve the control performance of diesel engine air systems because the control results of the air system significantly affect the emission level and drivability. However, the model based control algorithm requires a lot of unmeasurable states which are hard to be measured in a mass production engine. In this study, an air system model of the diesel engine is proposed to estimate 11 unmeasurable states using only sensors equipped in a mass production engine. In order to improve the estimation performance in the transient condition, dynamic characteristics of the air system are analyzed and implemented as discrete filters. Turbine and compressor efficiency models are also proposed to overcome a limitation of the constant or look-up table based efficiency values. The proposed air system model was validated in steady state and transient conditions by real-time engine experiments. The maximum error of the estimation for 11 physical states was 11.7%.

Effect of Occupants' Behaviour of Environmental Control on Improvement of Air Environment in Winter's High School Classroom (겨울철 고등학교 교실에서 재실자의 환경조절행동이 공기환경 개선에 미치는 영향)

  • Kwak, Ro-Yeul
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.36 no.4
    • /
    • pp.163-172
    • /
    • 2020
  • In this study, the effect of window opening, which is a control mechanism for air control in winter high school classrooms, on the change in air and indoor environment of the classroom was analyzed and physical conditions of indoor and air environment were observed during the classroom course, and satisfaction of the students and teachers was assessed with questionnaires. And the changes in air environment were assessed by the performance of the duster cleaning work in the classroom. It was found that 84.6% of the students surveyed said the air was stuffy. And among the alternatives, opening windows all times during class was most effective in reducing CO2 concentration and PM concentration was measured within classroom's standard. In addition, the concentration change rate of duster cleaning work was reduced by 74.4% and 65.4% of PM10 compared to broom cleaning work.