• Title/Summary/Keyword: Air Contact Control

Search Result 91, Processing Time 0.027 seconds

Estimation of Output Voltage and Magnetic Flux Density for a Wireless Charging System with Different Magnetic Core Properties

  • Park, Ji Hea;Kim, Sang Woo
    • Journal of Magnetics
    • /
    • v.18 no.2
    • /
    • pp.105-110
    • /
    • 2013
  • The design model and key parameters of the material design for the control of induced magnetic flux at the near-field and efficient power transfer in a modified wireless power transfer (WPT) system with a large air gap of wireless electric vehicles were investigated through analytical simulations for magnetic vector and time-domain transient analysis. Higher saturation magnetic core with low core loss induced a stronger vertical magnetic field by the W-type primary coil in the WPT system with a gap of 20 cm at 20 kHz, which is shown from the vector potentials of the magnetic induction. The transient analysis shows that the higher magnetic fluxes through the pick-up cores lead to a linear increment of the alternating voltage with a sinusoidal waveform in the non-contact energy transfer system.

Fluidic Manipulating in Microchannels Using Hydrophobic Patterns (소수성 패턴을 이용한 미세유로에서의 유체 조작)

  • Lee, Sang-Ho;Kim, Yong-Kweon
    • Proceedings of the KIEE Conference
    • /
    • 2000.11c
    • /
    • pp.583-585
    • /
    • 2000
  • This study reports the fluidic handling method using hydrophobic patterns inside PDMS microchannels. In order to obtain hydrophobic patterns, we pattern fluorcarbon(FC) film surfaces by lift-off process. FC films are deposited by spin coating method and plasma polymerization method. Hydrophobic surfaces are used as the barriers to control fluid flow. Injected liquid is spontaneously filled up inside PDMS-microchannels by the capillary action. Liquid flow stops when it meets hydrophobic regions which can be the barrier against fluid flow. Then, again, when liquid is pressurized externally, liquid can move toward another hydrophilic region by external air pressure. Contact angle analyses are performed on fluorocarbon films to estimate the wettability of film surfaces.

  • PDF

A Study for Failure Examples Including with Engine Oil Leakage, Poor Contact by Fin Damage and Vaporizer Inferiority on LPG Automotive (LPG 자동차의 엔진오일누설, 핀 손상에 의한 접촉불량, 베이퍼라이저 내부불량으로 인한 고장사례연구)

  • IL Kwon, Lee;Chang Ho, Kook;Sung Hoon, Ham;Seung Yong, Lee;Jae Gang, Lee;Seung Min, Han; Woo Chan, Hwang;Dae Cheon, Jang;Chang Bae, You;Jeong Ho, Lee
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.6
    • /
    • pp.24-29
    • /
    • 2022
  • This paper is a purpose to Analyze and study the failure examples for a engine oil leakage of camshaft bearing seal, poor contact by computer connector fin damage and vaporizer inferiority on LPG automotive. The first example, when the researcher disassembled the cylinder head of engine to establish the cause for oil leakage, he confirmed the engine oil leakage by damaged between the engine intake camshaft bearing and seal part. The second example, the connector fin of power source line that control the starting of a car supplied with engine computer. As a result, it found the fact that the engine operation stopped because of cutting of the power source by connector fin damage. The third example, it verified the engine incongruity phe cutting of the power source by connector fin damage. The third example, it verified the engine incongruity phenomenon as thd gas didn't flow the vaporizer by foreign substance deposit. Finally, it supplied a small quantity gas from vaporizer to mix. As the computer controlling mix opening condition supplied a air as opening signal, the air and fuel became rarefied state. it knew that the engine didn't produce prpper power. Therefore, a car have to throughtly inspect not in order to arise the failure symptoms.

Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014 (설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.7
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.

Health Risk Assessment for Workers Exposed to Diazinon Insecticide (디아지논 취급 근로자의 건강 위험성 평가)

  • Jung, Woo Jin;Kim, Chi Nyon;Won, Jong Uk;Kim, Ki Youn;Roh, Jaehoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.22 no.2
    • /
    • pp.100-106
    • /
    • 2012
  • Objectives: Diazinon is an insecticide which acts as a contact stomach and respiratory poison, and used throughout the world to control a wide range of sucking and chewing insects and mites on a range of crops. In this study, the airborne diazinon levels were measured for farmers, pest control operaters, landscapers, and agricultural chemicals sellers, and an assessment of the health risk to the workers was presented. The exposure scenario was based on the route of inhalation and skin absorption. The "OSHA Method No. 62" was used to sample and measure the airborne diazinon levels. The skin wipe method was applied to measure the level of the diazinone exposure through the skin. For the determination of exposure scenario, the exposure factors were surveyed for the daily average inhalation rate and the exposure period and frequency and time of diazinone as well as the body weight and lifetime of the workers. The median values of exposure frequency and exposure time were selected after evaluating the validity of those. Methods: The highest level of the diazinon exposure in the air was $107.21ug/m^3$ in farmers, followed by $93.53ug/m^3$ in landscapers, at $31.40ug/m^3$ in pest control operators, and $1.04ug/m^3$ in agricultural chemical seller. The amount of skin absorption was the highest in farmers at 63.39 ug/day, followed by landscapers at 10.47 ng/day, pest control operaters at 4.26 ng/day, and agricultural chemicals sellers at 0.34 ng/day. The hazardous indices calculated using toxicological reference value were 2.79 for pest control operaters, 0.41 for landscapers, 0.07 for agricultural chemicals sellers, and 0.06 for farmers. Conclusions: While the farmers were exposed to the high levels of diazinon through the air and skin, the pest control operaters, landscapers and agricultural chemicals sellers have more the diazinon hazards than the farmer based on the risk assessment in this study.

Study for Failure Examples of Solenoid Valve, Relay and Idle Speed Control Actuator in Liquid Petroleum Gas vehicle Engines (LPG 자동차 엔진의 솔레노이드밸브, 릴레이, 공회전조절장치의 고장사례 연구)

  • Kim, Chung-Kyun;Lee, Il-Kwon;Cho, Seung-Hyun
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.3
    • /
    • pp.47-52
    • /
    • 2011
  • The purpose of this paper analyzes and studies to seek the failure examples of electronic control actuators for engine in liquified petroleum gas vehicle. The first, it was verified phenomenon for intial starting damage and no-acceleration of engine because of occasionally fuel feeding interception by clogged of emergency cutting solenoid valve filter. The second, the contact resistance produced in the connecting part of engine control relay because of no fully surface contacting by processes and assembly badness. It was displayed phenomenon of re-starting badness. The actuator that idle speed control system was sticked inside because of intake-air decreasing by carbon deposit. As a result, it was verified the phenomenon of disharmony that repeated up and down the engine revolution.

Removal of Volatile Organic Contaminant(toluene) from Specific Depth in Aquifer Using Selective Surfactant-Enhanced Air Sparging (계면활성제와 폭기를 이용한 대수층의 특정깊이에 존재히는 휘발성 유기오염물질 (톨루엔)의 휘발제거)

  • Song, Young-Su;Kwon, Han-Joon;Yang, Su-Kyeong;Kim, Heon-Ki
    • Economic and Environmental Geology
    • /
    • v.43 no.6
    • /
    • pp.565-571
    • /
    • 2010
  • An innovative application of surfactant-enhanced air sparging(SEAS) technique was developed in this study. Using a laboratory-scale physical model packed with water-saturated sand, air sparging was implemented to remove water-dissolved toluene that was introduced into a specific depth of the system with finite vertical width prior to sparging. An anionic surfactant(Sodium dodecylbenzene sulfonate) was introduced into the contaminated layer as in dissolved form in the toluene-contaminated solution for SEAS, whereas no surfactant was applied in the control experiment. Due to the suppressed surface tension of water in the surfactant(and toluene)-containing region, the toluene removal rate increased significantly compared to those without surfactant. More than 70% of the dissolved toluene was removed from the contaminated layer for SEAS application while less than 20% of toluene was removed for the experiment without surfactant. Air intrusion into the contaminated layer during sparging was found to be more effective than that without surfactant, enhancing air contact with toluene-contaminated water, which resulted in improved volatilization of contaminant. This new method is expected to open a new option for remediation of VOC(volatile organic compound)-contaminated aquifer.

Influences of Cathodic Protection and Coating Properties on the Corrosion Control of Metallic Structure in Extremely Acidic Fluids

  • Chang, H.Y.;Yoo, Y.R.;Jin, T.E.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • v.4 no.6
    • /
    • pp.242-249
    • /
    • 2005
  • A lot of parts in FGD (Flue Gas Desulfurization) systems of fossil-fuel power plants show the environments in which are highly changeable and extremely acidic corrosive medium according to time and locations, e.g. in duct works, coolers and re-heaters etc. These conditions are formed when system materials are immersed in fluid that flows on them or when exhausted gas is condensed into thin layered acidic medium to contact materials of the system walls and roofs. These environments make troublesome corrosion and air pollution problems that are occurred from the leakage of the condensed solution. To cathodically protect the metallic structures in extremely acidic fluid, the properties of the protective coatings on the metal surface were very important, and epoxy Novolac coating was applied in this work. On the base of acid immersion tests, hot sulfuric acid decreased the hardness of the coatings and reduced greatly the content of $Na_2O$, $Al_2O_3$, and $SiO_2$ among the main components of the coating. A special kind of CP(Cathodic Protection) system has been developed and tested in a real scale of the FGD facility. Applied coating for this CP system was peeled off and cracked in some parts of the facility. However, the exposed metal surface to extremely acidic fluid by the failure of the coatings was successfully protected by the new CP system.

A Study on the Design of the Flywheel Energy Storage Device to Store the Regenerative Energy (회생에너지 저장용 플라이휠 에너지 저장 장치 설계에 관한 연구)

  • Lee, Jun-Ho;Park, Chan-Bae;Lee, Byeong-Song
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.7
    • /
    • pp.1045-1052
    • /
    • 2013
  • In this study we deal with design procedures for the flywheel energy storage system that has the capacity to store the regenerative energy produced from the railway vehicles. The flywheel energy storage system (FESS) stores the regenerative electrical energy into the high speed rotational flywheel, by conversion the electrical energy into the mechanical rotational energy. Thus the FESS is composed of the energy conversion components, such as the motor and generator, mechanical support components, such as the rotational rotor, the magnetic bearings to support the rotor, and the digital controller to control the air gap between the rotor and the magnetic bearings. In this paper the design procedures for the rotor operating at the rigid mode and the magnetic bearings to support the rotational rotor without contact are presented.

Implementation of 4-Channel Electrolyte Analyzer using ISFET Microsensors (ISFET 마이크로센서를 이용한 4-채널 전해질 분석기의 구현)

  • Bae, S.K.;Kim, K.Y.;Won, C.H.;Cho, B.W.;Kim, C.S.;Sohn, B.K.;Cho, J.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.22-26
    • /
    • 1996
  • In this paper, we designed 4-channel electrolyte analyzer that can measure simultaneousely the 4 electrolytes - pH, $pNa^{+}$, $pCa^{2+}$, and $pK^{+}-$ using 2-point calibration and implemented it. Developed electrolyte analyzer consists of singal processing part, actuator part and control unit for sample flow system. To implement reliable instrument, design considerations are emphasized on flow system and sample chamber that requires small sample volume and prevent air contact with sample solution. In addition to the hardware design, we developed system software which controls full measuring process. After system developed, we verified the system performance by the test measurement for pH, $pNa^{+}$, $pCa^{2+}$, and $pK^{+}$ value.

  • PDF