• 제목/요약/키워드: Air Conditioning Duct

검색결과 189건 처리시간 0.023초

공장환기용 선회 제트 디퓨저의 유동 특성에 관한 실험 연구 (An Experimental Study on the Flow Characteristics of a Swirl-Jet Diffuser)

  • 이춘식;정종수;정시영;홍기혁
    • 설비공학논문집
    • /
    • 제6권2호
    • /
    • pp.103-109
    • /
    • 1994
  • An experimental study is performed on the flow characteristics of a swirl-jet diffuser for factory ventilation. Swirl number ranges from 0(nonswirl jet) to 0.6 when the angle of swirl vane is 60 degree. As swirl becomes strong, the maximum velocity in the plane perpendicular to jet axis decreases fast and the uniformity of velocity becomes good, particularly in the ventilated area. The similarity in velocity profiles has been found for axial velocity from even when swirl number equals 0.6. The flow characteristics of the swirl-jet which has the swirl number of 0.6 is thought to be the best among these three swirl numbers for factory ventilation. However, the pressure drop in the diffuser increases as the swirl becomes strong. This should be considered in the design of the total ventilation system including a duct system.

  • PDF

Heat Transfer Characteristics in a Cylindrical Duct Packed with Solid Spheres

  • Lee, Seung-Hyuk;Kang, Kwan-Gu;Kim, Sung-Chan;Ryou, Hong-Sun;Noh, Dong-Soon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제13권1호
    • /
    • pp.11-21
    • /
    • 2005
  • The present paper investigates the heat transfer characteristics in a cylinder packed with porous medium of solid spheres for various parameters such as mass flow rate, sphere diameter, length of the porous medium, and gas temperatures. Pressures and temperatures at the inlet and outlet regions were measured by using static pressure gages and R-type thermocouples. The modified relationship based on the Ergun equation is suggested for the estimation of pressure drops. In addition, the useful empirical correlation for thermal efficiency is obtained in the current study. Thermal efficiency is expressed in terms of non-dimensional time, sphere diameter, porosity, and pressure drops. It is also found that the pressure drop through the cylinder becomes larger as the gas temperature does higher at the inlet region, whereas it substantially decreases when the inlet flow rate decreases.

순간압력강하치의 통계적 해석을 통한 경사관내 2상유동양식의 판별 (Identification of Two-Phase Flow Patterns in a Inclined Duct Based upon a Statistical Analysis of Instantaneous Pressure Drop)

  • 이상천;이정표;김중엽
    • 대한설비공학회지:설비저널
    • /
    • 제17권5호
    • /
    • pp.590-597
    • /
    • 1988
  • Characteristics of flow regime transitions in inclined upwards gas-liquid two-phase flow have been investigated based upon a statistical analysis of instantaneous pressure drop curves through an orifice. The probability density functions of the curves indicate distinct patterns depending upon two-phase flow regime, which are very similar to those of horizontal two-phase. The dimensionless intensity of fluctuations of the pressure drops sharply change as the flow transitions such as plug-slug, pseudo slug-slug and annular-slug take place. The effects of inclination angle on the flow regime transitions have been also investigated. The results show that the method to identify the flow pattern based upon the statistical analysis of instantaneous pressure drops is suitable for inclined flow as well as horizontal flow.

  • PDF

이온풍 공랭 방식 적용을 위한 방송용 LED 조명장치의 냉각 특성 해석 (Analysis of Cooling Characteristics of Broadcasting LED Light with Ion Wind Generator)

  • 박철우;이승준;김대중
    • 설비공학논문집
    • /
    • 제24권9호
    • /
    • pp.693-698
    • /
    • 2012
  • In the present work, numerical analyses of broadcasting LED light with ion wind generator have been carried out for enhancement of cooling performance. Ion wind generator is produced and experimented before analysis. With the use of result of experiments, broadcasting LED light model is computed. Ion wind velocity into LED light is varied with 0~3 m/s. Based on the numerical results, the area of duct-type ion wind generator was designed to reduce the volume flow rate of ion wind. The modified inlet geometry shows sufficient cooling capability. And, through modified ion wind generator, the volume flow rate of ion wind has been largely reduced.

주기적인 원주형 장애물이 있는 덕트유동 및 열전달의 비직교좌표변환에 의한 해석 (Numerical Analysis of Flow and Heat Transfer in Duct with Repeated Cylindrical Blockages by Non-orthogonal Coordinate Transformation)

  • 최영돈;이건휘
    • 대한설비공학회지:설비저널
    • /
    • 제17권4호
    • /
    • pp.473-488
    • /
    • 1988
  • This paper is concerned with the prediction of two dimensional turbulent flows in the parallel plate with the repeated cylindrical blockages. The purpose of this paper is to find the effect of the eccentricity and the pitch of the repeated cylindrical blockages on the flow field, heat transfer coefficients and friction factors. A special technique is developed for the solution of the fully developed turbulent recirculating flow, in which the flow field varies periodically. A non-othogonal coordinate transformation is employed to solve the momentum and the energy equations. The results show that the pitch ratio or the eccentricity of the repeated blockages become smaller, or the Reynolds number of the flow larger, friction factors and heat transfer coefficients increase.

  • PDF

주거 환기 시스템의 공기 분배 성능 개선 방안 (A Method for Improving Air Distribution Performance at the Residence Ventilation System)

  • 박은준;김용봉;나희형;이상기
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.589-593
    • /
    • 2007
  • In the mechanical ventilation system, it is a fundamental condition to distribute the air equally to the each room. In this study, distribution performance of the air distributor which generally connected to a circular duct was investigated by simulation and experiment. In the first CFD analysis, maximum air flow rate deviation was an 63% in the air distributor model. After numbers of model modification and simulation, maximum flow rate deviation was reduced to 19% in the final simulation model. An air distributor which used in the experiment was produced by using data obtained from the final analysis. When experimental result was compared with analysis result, there was a deviation difference as much as 9%.

  • PDF

설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제27권7호
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.

Class 1000 클린룸에서 편류 개선에 관한 연구 (A Study on the Improvement of Airflow Deflection in a Cleanroom of Class 1000)

  • 노광철;이승철
    • 설비공학논문집
    • /
    • 제22권4호
    • /
    • pp.225-233
    • /
    • 2010
  • We performed 3 dimensional numerical study on the improvement of the airflow deflection in the cleanroom of Class 1000, which is presently operated for the manufacturing process in Korea. The Deflection angle and the non-uniformity were investigated to analyze the airflow characteristics and the performance of cleanroom with variations of the cleanroom occupancy state, the filters' arrangement, and the floor return air system. From the numerical results, we found out that the airflow pattern of the cleanroom is more unidirectional and stable in the condition of at-rest than in the condition of as~built. It is due to that the equipments installed in the cleanroom play a role like partitions, which prevent the airflow from inclining toward the recirculation air duct. And it is needed to arrange the filter units parallel to the equipments array without a gap between them for maintaining the unidirectional airflow pattern. Finally, we knew that it is very important to install the partition like the eyelid above the equipment to keep the unidirectional airflow around the equipments and remove the contaminants quickly.

소형 공동주택의 하이브리드 환기시스템 성능실험 연구 (A Study on the Performance Evaluation of the Hybrid Ventilation System for Small Apartment Houses)

  • 전주영;김길태;이종성;김상희
    • 설비공학논문집
    • /
    • 제20권10호
    • /
    • pp.696-701
    • /
    • 2008
  • From Feb. 2006, the ventilating systems with air exchange rate of over 0.7times/hour are installed at the apartment houses (over 100 units). Installation cost and maintenance cost are very important factors for ventilating system because consumers have to pay the expenses of that system. Especially small apartment needs more considerations because small apartment is comparatively the economically weak part. The purpose of this study is to the performance evaluation of the hybrid ventilation system for small apartment houses. Hybrid system 1 consists of natural ventilation system and duct type exhaust diffusers. Hybrid system 2 has natural ventilation system and toilet exhaust system with static pressure fan. Infiltration of test apartment houses with ventilation system is under 0.1 times/hour. Mean air age of hybrid system 1 is 1.52 hours and hybrid system 2 is 1.42 hours. Mean ventilation effectiveness of hybrid system 2(93%) is higher than that of hybrid system 1(81%).

푸드서비스시설의 주방 설비 산정 매뉴얼 개발: 설렁탕 전문 식당 사례 적용 (Developement of a Design Manual for Kitchen Facility in Foodservice Outlets: A Case Study on a Seolleongtang Specialized Restaurant)

  • 최경기;장혜자
    • 급식외식위생학회지
    • /
    • 제2권2호
    • /
    • pp.67-77
    • /
    • 2021
  • Concerns regarding work and food safety in foodservice operations are growing. The purpose of the study is to suggest guidelines for designing foodservice facilities, including school foodservices and Korean restaurants. A case of a franchise restaurant specializing in a Korean food item, Seolleongtang, was used to explain the facility design. The contents of the manual included ways to determine space allocation, calculate the application of utilities and the diameters of supply utility pipelines, and suggestions on how to decide on air conditioning equipment. The standards of the American Gas Association and the Japan Foodservice Equipment Association (JFEA) were applied to design the restaurant space. The JFEA standards and knowledge based on experience and statistics were applied to calculate the usage of utilities like fuel and water. The standards of JFEA and the Society of Heating, Air-Conditioning, and Sanitary Engineers of Japan were applied to calculate the diameters of the water supply and drainage pipelines. For the setting of the heating, ventilation, and air conditioning systems, three ways to carry out the calculation of effective ventilation were explained, as well as options to dicide the standard parameters of the duct and ventilation fans. This manual can contribute to the design of effective and efficient foodservice facilities and help secure the work safety of foodservice employees thereby ensuring food safety.