재해임시주거 냉난방을 위하여 기존 에어컨을 열펌프로 전환하는 변환기 개발 (Development of a Conversion Unit converting the existing air conditioner to Heat Pump System for the Emergency Shelter)

  • 송헌
    • 한국태양에너지학회 논문집
    • /
    • 제31권5호
    • /
    • pp.77-84
    • /
    • 2011
  • Korea and some other countries located in the northern hemisphere employ the air conditioner for the space cooling in the hot summer season and also some kinds of heaters for the space heating in the cold winter season. Especially in Korea, a great number of air conditioners of about 12,700,000 sets have been used these days. However, they are used for a short operation period of only 58 days a year, which results in the material and economic losses. To solve this problem and employ this system for the emergency shelter, a new conversion unit which could convert the existing air conditioner to a heat pump system for simultaneous heating and cooling was developed in this study, and the thermal performance was tested. The results indicated that the indoor air could be heated from $27^{\circ}C$ to $39^{\circ}C$ by the air conditioner converted to a heat pump system with the ambient temperature variation of $-10^{\circ}C{\sim}10^{\circ}C$, and cooled from $20^{\circ}C$ to $15^{\circ}C$ by the converted system with the ambient temperature variation of $20^{\circ}C{\sim}35^{\circ}C$. And also the heating COP increased from 3.3 to 5.3 in case of the heat exchange of the super cooling(HESC) circuit and from 3.0 to 4.0 in case of the By-pass with the ambient temperature variation of $-10^{\circ}C{\sim}10^{\circ}C$, respectively, whereas the cooling COP decreased from 3.1 to 2.1with the increase of the ambient temperature from $20^{\circ}C$ to $35^{\circ}C$.

HCFC22 대체 R290, R1270 및 R1270/R290, R290/HFC152a, R1270/R290/RE170 혼합냉매의 공기조화기와 열펌프 작동범위에서의 성능 평가 (Performance of HCFC22 Alternatives R1270, R290, R1270/R290, R290/HFC152a, R1270/R290/RE170 Refrigerants for Air-conditioning and Heat Pump Applications)

  • 황지환;백인철;정동수
    • 설비공학논문집
    • /
    • 제18권4호
    • /
    • pp.312-319
    • /
    • 2006
  • In this study, performance of 2 pure hydrocarbons and 7 mixtures was measured in an attempt to substitute HCFC22 used in air-conditioners and heat pumps. The mixtures were composed of R1270 (propylene), R290 (propane), HFC152a, and RE170 (Dimethyl ether, DME). The pure and mixed refrigerants tested have GWPs of $3{\sim}58$ as compared to that of $CO_2$ and the mixtures are all near-azeotropic showing the gliding temperature difference (GTD) of less than $0.6^{\circ}C$. Thermodynamic cycle analysis was carried out to determine the optimum compositions and actual tests were performed in a laboratory heat pump test bench at the evaporation and condensation temperatures of 7.5 and $45.1^{\circ}C$ respectively. Test results show that the coefficient of performance (COP) of these mixtures is up to 5.7% higher than that of HCFC22. While propane showed 11.5% reduction in capacity, most of the fluids tested had the similar capacity to that of HCFC22. Compressor discharge temperatures were reduced by $11{\sim}17^{\circ}C$ with these fluids. There was no problem with mineral oil since the mixtures were mainly composed of hydrocarbons. The amount of charge was reduced up to 55% as compared to HCFC22. Overall, these fluids provide good performance with reasonable energy savings without any environmental problem and thus can be used as long term alternatives for. residential air-conditioning and heat pumping application.

토양개량제 시용이 토양물리성과 담배생육에 미치는 영향 (Effect of Some Soil Conditioners on Soil Physical Properties and Tobacco Growth)

  • 이철환;진정의;한철수
    • 한국작물학회지
    • /
    • 제41권6호
    • /
    • pp.685-691
    • /
    • 1996
  • 답전전환지의 잎담배 품질을 밭담배 수준으로 향상시키기 위한 재배법 개선의 기초자료로 이용 하고자 몇가지 토양개량제를 처리하여 토양의 입단형성량과 안정성등의 물리성 개선효과를 분석하고 잎담배 생육에 미친 영향을 조사한 결과는 다음과 같다. 1. 토양의 내수성 입단형성량은 polyvinylalco-hol(PVA) > perlite > zeolite순으로 많았고 식생에 적당한 크기(0.25~l.0mm)의 입단형성률은 PVA처리구에서 가장 높았다. 2. 내수성 입단형성률은 토양수분 함량이 높을 수록 입단화률도 증가하여 50%구에서 가장 높았으나 형성된 입원은 직경 2mm이상의 큰 입단비률이 높아 식생에 적당한 크기(0.25~l.00mm)의 입단형성량과 실제 농기계의 작업능률등을 고려하면 토양수분은 40%구가 적당할 것으로 판단되었다. 3. 토양립단의 안정성, 통기성 및 투수성은 토양개양제 처리로 무처리에 비해 현저히 증가되고 PVA처리구가 가장 양흐하였으며, 공린률도 무처리에 비해 다소 증가되는 경향이나 개량제종류간에는 대등하게 나타났다. 4. 토양개량제 처리로 토양 3상 비율의 개선효과가 인정되었고, 통기성은 zeolite perlite처리구가, 투수성은 PVA처리구가 높았으며, 무처리구에 비해 전체적으로 보수력이 증대되었다. 5. 연초의 생육량은 전 수량 구성요소에서 개량제처리로 현저히 증가하였고 지상부에 비해 지하부의 생장량 증가가 더 크게 나타났으며, 생장양과 연계한 토양개량제의 물리성 개선효과는 PVA > perlite > zeolite순으로 나타났다.

  • PDF

토양구조개선제(土壤構造改善劑) 처리(處理)가 토양물리성(土壤物理性)과 상추생육(生育)에 미치는 영향(影響) (Effects of Some Soil Conditioners on Soil Physical Properties and Lettuce Growth)

  • 류인수;한정임;조인상
    • 한국토양비료학회지
    • /
    • 제28권3호
    • /
    • pp.249-255
    • /
    • 1995
  • 사토, 사양토, 양토, 식양토의 4개 토양에 Polyvinyalcohol(PVA), Polyacrylamide(PAM) 및 Bitumen을 분무처리하여 토양의 입단형성과 수분특성에 미친 영향을 조사하였으며 한편, Pot 재배 시험을 통하여 PAM 처리가 상추의 발아율과 생육에 미친 효과를 검토하였다. 2mm 이상의 입단함량(粒團含量)은 Soil conditioner를 처리하지 않은 토양에서 사토 0%, 사양토 45%, 양토 80%, 식양토 90%이었고 PVA, PAM 및 Bitumen의 처치에 의해서는 사도 20~52%, 사양토 55~76% 범위로 증가되었으나 양토와 식양토에서는 변화가 적었다. Soil conditioner 처리에 의해 내수성(耐水性) 입단(粒團)이 증가되었고 입단의 불안정성(不安定性)은 감소되었다. 토양(土壤)의 습윤각(濕潤角)은 PAV와 PAM 처리에서는 거의 변화가 없었으나 Bitumen 처리에 의해서는 무처리토양과 비교하여 크게 높아져서 소수성이 증가되었다. 침수성과 흡수성은 Bitumen 처리에 의해 모든 토성에서 물의 이동이 나타나지 않았으며 PVA와 PAM 처리에 의해서는 사토를 제외할 토성에서는 큰 변화가 없었다. PAM 처리에 의하여 상추의 발아율. 뿌리무게와 지상부 건물중이 무처리에 비해 크게 증가되고 그 효과는 사양토와 미사질양토에 비하여 사토에서 매우 컸는데 이는 PAM 처리에 의해 토양의 보수력과 기상비율이 함께 증가되어 상추생육을 촉진한 결과로 판단된다.

  • PDF

직접부하제어자원으로서 에어컨 주기제어 방법론 개발 (Development of Control Method for Air-Conditioner as the Resources of DLC)

  • 두석배;김정욱;김형중;김회철;박종배;신중린
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.145-147
    • /
    • 2005
  • This paper presents a methodology for satisfying the thermal comfort of Indoor environment and reducing the summer peak demand power by minimizing the power consumption for an Air-conditioner within a space. KEPCO(Korea Electric Power Corporation) use the fixed duty cycle control method regardless of the indoor thermal environment. This method has disadvantages that energy saying depends on the set-point value of the Air-Conditioner and DLC has no net effects on Air-conditioners if the appliance has a lower operating cycle than the fixed duty cycle. A variable duty cycle estimates the PMV(Predict Mean Vote) at the next step with a predicted temperature and humidity coming from the back propagation neural network model. It is possible to reduce the energy consumption by maintaining the Air-conditioner's OFF state when the PMV lies in the thermal comfort range. The proposed methodology uses the historical real data of Sep. 7th, 2001 from a classroom in seoul to verify the effectiveness of the variable duty cycle method comparing with fixed duty cycle. The result shows that the variable duty cycle reduces the peak demand to 2.6times more than fixed duty cycle and increases the load control ratio by 8% more. Based on the variable duty cycle control algorithm, the effectiveness of DLC is much more improved as compared with the fixed duty cycle.

  • PDF

에어컨 실내기의 수축팽창 소음 저감 방법 (An effective method to reduce the contraction and expansion noise of air conditioner)

  • 김강환;김원진
    • 한국음향학회지
    • /
    • 제39권2호
    • /
    • pp.98-104
    • /
    • 2020
  • 에어컨 운전 중에 발생하는 실내기의 수축팽창 소음 현상을 분석하고, 발생위치를 평가한다. 그리고 마찰실험을 통하여 수축팽창 소음을 유발하는 인자를 규명하고자 한다. 먼저 항온·항습챔버에서 운전 환경 조건별로 수축팽창 소음의 발생횟수 및 특성을 분석하고, 분해법을 이용하여 냉방 및 난방 시 모두 하부 데코에서 발생하는 것을 확인하였다. 실내기에서 발생하는 수축팽창 소음은 하부 데코와 연결되는 부품들과의 체결부에서 발생하는 스틱슬립 현상에 의한 것으로 이러한 소음을 유발하는 인자를 규명하기 위하여 마찰실험을 진행하였다. 또한 마찰실험 결과의 효과적 분석을 위하여 십점평균 산출법을 도입하고, 실험 결과에서 Acrylonitrile Butadiene Styrene(ABS) 재질 간에 접촉하면 스틱슬립 현상을 유발하며 체결부의 양면에 표면조도를 증가하는 것이 소음저감에 효과적임을 확인하였다.

HFC32/HFC125 혼합냉매의 히트펌프 성능 평가 (Performance of HFC32/HFC125 Mixtures for Heat Pumps)

  • 김욱진;강동규;이요한;정동수
    • 설비공학논문집
    • /
    • 제23권12호
    • /
    • pp.791-798
    • /
    • 2011
  • In this study, performance of R410A(50%R32/50%R125) and HFC32/HFC125 mixture is measured to examine the effect of composition shift of R410A used for various air-conditioners and heat pumps. The composition of HFC32/HFC125 mixture varies from the reference composition of R410A ${\pm}10%$ with 5% interval. Tests carried out in a heat pump bench tester at the evaporation and condensation temperatures of $7/45^{\circ}C$ and $-7/41^{\circ}C$ for summer and winter conditions, respectively. Test results show that both the coefficient of performance (COP) and compressor power of the HFC32/HFC125 mixture have the maximum difference of 2.0% as compared to those of R410A. Compressor discharge temperatures of HFC32/HFC125 mixture are increased up to $6.7^{\circ}C$ as compared to that of R410A. The amount of charge for HFC32/HFC125 mixture vary within 5.6% as compared to that of R410A. Overall, performance of R410A is not appreciably affected by the composition shift of ${\pm}10%$ of R32 under both air-conditioning and heat pumping conditions.

LNG 냉열이용 지역집단 냉방시스템에 대한 연구 (A Study on the District Community Cooling System using LNG Cold Energy)

  • 김청균;김승철
    • 한국가스학회지
    • /
    • 제14권6호
    • /
    • pp.27-30
    • /
    • 2010
  • 본 논문은 LNG 냉열에너지를 이용한 지역집단 냉방에너지 시스템을 공급하기 위한 시스템 공정설계에 관한 연구이다. 새로이 개발한 LNG 냉방시스템은 여러 개의 열교환기, LNG 저장탱크, 열매체 저장탱크, 여러 개의 냉열에너지 저장탱크, 가스냉방기, 압축기, 정압기, 저온 및 고온에너지 공급배관 등으로 구성되도록 설계하였다. 또한, 가스냉방기는 여름철에 도시가스 소모량에 의해 충분하지 못한 LNG 냉열에너지를 안정적으로 공급하기 위해 설치되었다. 냉방에너지 공급시스템은 공기라는 열매체와 200kcal/kg의 냉열에너지를 가진 LNG 사이의 열교환 작용에 의해 냉방에너지를 공급하는 효율성과 안전성을 함께 갖추고 있다. 또한, LNG 냉열에너지를 이용한 지역집단 냉방에너지 공급시스템은 공기중으로 CO2나 프레온 가스를 방출하기 않는다는 장점을 간고 있다.

미국거주 한국인의 저층 공동주택 소음 환경에 대한 주관적 평가 - Athens시 중심으로 - (A Subjective Evaluation on the Noise Environment of the Low - rise Multifamily House of Korean lived in Athens, America)

  • 곽경숙
    • 한국주거학회논문집
    • /
    • 제10권2호
    • /
    • pp.203-212
    • /
    • 1999
  • The purpose of this study is to evaluate the Korean residents' subjective opinion of the noise on the lowrise multifamily house in America. The results of this study can be applied for the prevention of noise when planning cities, roads, and multifamily houses in Korea. The subjects of this study are three kinds of multifamily houses and their 124 Korean residents in Athens, America. The results of this study are as follows. The Korean residents felt the noise from lawn mowers and the sound of filter fan of air conditioners were higher than all the other external noise. They were disturbed a little by the external noise. The air borne sound was recognized a little by Korean residents but they only felt moderate sound of building services and household equipment from the solid borne sound of the internal noise. They suffered worse from external noise in the summer and they felt worse from 8~12 o'clock due to external noise and 20~24 o'clock due to internal noise. The Korean residents liked the sound of birds or insects, the sound of cars and trains. However many Korean people in Athens disliked the sounds of birds or insects and lawn mowers more than these sounds in Korea. The Korean residents who were living in the apartment houses felt better than those in the other multifamily houses.

  • PDF

광촉매와 조합된 코로나 방전 플라즈마 필터의 유해 가스 및 입자 제거 특성 (A Compact Pulse Corona Plasma System with Photocatalyst for an Air Conditioner)

  • 신수연;문재덕
    • 전기학회논문지
    • /
    • 제56권1호
    • /
    • pp.151-155
    • /
    • 2007
  • A compact discharge plasma system with a photocatalyst has been proposed and investigated experimentally for application to air conditioners. It was found that there was intense ultra violet radiation with high energy of 3.2 eV from the corona discharge due to the DC-biased pulse voltage applied on a wire. An electrophotochemical reaction took place apparently on the surfaces of the photocatalyst of $TiO_2$ irradiated ultra violet front the discharge plasma in the proposed plasma system. The proposed discharge plasma system with the photocatalyst of $TiO_2$ showed very high removal efficiency of VOCs by tile additional electrophotochemical reactions on the photocatalyst. The proposed discharge plasma system also showed very high removal efficiency of particles such as smokes, suspended bacteria, and pollen and mite allergens by the electrostatic precipitation part. This type of corona discharge plasma system with a photocatalyst can be used as an effective means of removing both indoor pollutant gases and particles including suspended allergens.