Development of a Conversion Unit converting the existing air conditioner to Heat Pump System for the Emergency Shelter

재해임시주거 냉난방을 위하여 기존 에어컨을 열펌프로 전환하는 변환기 개발

  • Song, Heon (School of Architectural Engineering, Hongik University)
  • 송헌 (홍익대학교 건축공학부)
  • Received : 2011.08.04
  • Accepted : 2011.09.30
  • Published : 2011.10.30

Abstract

Korea and some other countries located in the northern hemisphere employ the air conditioner for the space cooling in the hot summer season and also some kinds of heaters for the space heating in the cold winter season. Especially in Korea, a great number of air conditioners of about 12,700,000 sets have been used these days. However, they are used for a short operation period of only 58 days a year, which results in the material and economic losses. To solve this problem and employ this system for the emergency shelter, a new conversion unit which could convert the existing air conditioner to a heat pump system for simultaneous heating and cooling was developed in this study, and the thermal performance was tested. The results indicated that the indoor air could be heated from $27^{\circ}C$ to $39^{\circ}C$ by the air conditioner converted to a heat pump system with the ambient temperature variation of $-10^{\circ}C{\sim}10^{\circ}C$, and cooled from $20^{\circ}C$ to $15^{\circ}C$ by the converted system with the ambient temperature variation of $20^{\circ}C{\sim}35^{\circ}C$. And also the heating COP increased from 3.3 to 5.3 in case of the heat exchange of the super cooling(HESC) circuit and from 3.0 to 4.0 in case of the By-pass with the ambient temperature variation of $-10^{\circ}C{\sim}10^{\circ}C$, respectively, whereas the cooling COP decreased from 3.1 to 2.1with the increase of the ambient temperature from $20^{\circ}C$ to $35^{\circ}C$.

Keywords

References

  1. 한윤호, 이종우, 열환경의 쾌적범위에 관한 연구, 대한건축학회논문집, 4권 4호, 통권 18호, 1986, pp157-166
  2. 유환규, 정동수, 가정용 냉방기의 대체냉매 성능분석을 위한 전산 해석 연구, 한국태양에너지학회지, 15권 3호, 1995
  3. Fuad Kent, E., Performance Evolution of a Compact Air-to-air Heat pump., Energy Convers, 38(4), 1997
  4. Marchal, D.A., Simulation model of refrigeranting and Air-conditioning Equipment based on experimental data, ASHRAE 3532
  5. Olympia Z., Anestassions S., Effect of climatic condition on the design optimization of heat pump systems for space heating and cooling, Energy Convers, 39(7), 1998
  6. Blundell C.J., Optimizing Heat Exchangers for Air-to-Air space Heating Heat pumps in the U.K., Int.J, Energy Res 1,1997