• 제목/요약/키워드: Air Condensation

검색결과 440건 처리시간 0.031초

초고층 커튼월 외피 열성능해석 프로그램 개발에 관한 연구 (A Study on the Development of High-rise Curtain Wall Thermal Analysis Program)

  • 노상태;김강수;정진세
    • 설비공학논문집
    • /
    • 제19권1호
    • /
    • pp.10-18
    • /
    • 2007
  • The purpose of this study is to develop an user-friendly computer program which can analyze the thermal performance of high-rise curtain wall. In this study, the sub-routines for FVM SOLVER, HIGH-RISE CONDITION CALCULATION, AUTOMATIC SPECIFICATION BOUNDARY/MESH, MATERIAL DATABASE, and GRAPHICAL CONDENSATION/U-FACTOR OUTPUT were developed by using Visual Basic. The curtain wall heat conduction simulation results of program showed good agreement with those of FLUENT and THERM. The minimum and maximum relative error rates were 3.17 and 9.68% compared to other software.

히트펌프식 냉난방장치의 철도차량 적용에 관한 연구 (A study on the application Heat Pump to Rolling Stock Air conditioner)

  • 권태균;송영정;정광무
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.1689-1696
    • /
    • 2008
  • Heat pumps transfer heat by circulating a substance called a refrigerant through a cycle of evaporation and condensation. But Heat pumps system by only using heat-source is not efficient. Because the mean temperature of North Korean winter season is low, economy of air heat-source heat pump descend. This paper is practiced the simulation on evaluation criteria for Heat pump heating and cooling systems to Rolling Stock. Efficiency of the heat pump in order improving from certainly the development of the technique will be able to prevent a freezing actual condition must proceed. As a result, Below $-10^{\circ}C$ used heating and cooling systems of heat pump format even in cold winter season and is serviceable confirmed with heat source supply circle of the Rolling Stock.

  • PDF

프로필렌 냉매의 응축열전달 특성에 관한 실험적 연구 (Condensing Heat Transfer Characteristics of Propylene Refrigerant)

  • 이호생;김재돌;윤정인
    • 설비공학논문집
    • /
    • 제16권7호
    • /
    • pp.639-644
    • /
    • 2004
  • This paper deals with the heat transfer characteristics of R-1270 (Propylene), R-600a (Iso-butane) and R-290 (Propane) as an environment friendly refrigerant and R-22 for condensing. The experimental apparatus has been set-up as a conventional vapor compression type heat pump system. The test section is a horizontal double pipe heat exchanger. A tube diameter of 12.70 mm with 1.32 mm wall thickness is used for this investigation. The test results showed that the local condensing heat transfer coefficients of hydrocarbon refrigerants were higher than that of R-22. The average condensing heat transfer coefficient was obtained with the maximum value in R-1270 and the minimum one in R-22. Comparing the heat transfer coefficient of experimental results with that of other correlations, the presented results had a good agreement with the Cavallini-Zecchin's correlation. It reveals that the natural refrigerants can be used as substitute for R-22.

강제 대류에서 수증기의 찬물 표면에서의 응축 (Forced Convection Condensation of Vapor on A Cold Water)

  • 박재걸;이승홍
    • 대한설비공학회지:설비저널
    • /
    • 제13권3호
    • /
    • pp.141-147
    • /
    • 1984
  • 2차원 채널 입구에서의 꿰떼 난류 유동하는 찬 물 위를, 같은 방향으로 빠르게 난류 유동하는 수증기의 응축은 액체필름 초기상태의 과냉 정도에 의하여서 응축능력이 정하여진다. 수증기와 액체의 채널 입구에서의 균일한 속도 및 온도, 그리고 채널 입구에서 액체와 증기가 차지하는 체적비, 즉 액체필름과 채널 높이를 알고 있을 때, 하류로 유동하면서 응축이 일어나는 현상을 예측하는 모델을 제안하고, 실험치와 비교한 것이다. 채널 입구에서 윗쪽으로는 더운 기체, 아래쪽으로는 찬 액체가 평행한 방향으로 유동하면서 접촉하고 평균적인 액체필름의 두께와 단열된 채널 벽체를 가정하여서, 기본방정식으로 연속방정식, 운동방정식을 세우고. 에너지와 운동량 전달 메카니즘 사이에 유사성이 존재한다고 가정하였으며, 전단응력의 크기는 필자의 모델을 적용하였다. 기본방정식을 기체 속도, 액체 속도, 필름의 두께, 압력에 대해서 수치해를 구하여서 동일조건 하에서 실험한 데이터와 비교하였다. 수증기와 액체 경계면에서의 전단응력은 매우 좋은 일치를 보여주고 있다.

  • PDF

Two-fluid modelling for poly-disperse bubbly flows in vertical pipes: Analysis of the impact of geometrical parameters and heat transfer

  • Andrea Allio ;Antonio Buffo ;Daniele Marchisio;Laura Savoldi
    • Nuclear Engineering and Technology
    • /
    • 제55권3호
    • /
    • pp.1152-1166
    • /
    • 2023
  • The bubbly flow of air or steam in subcooled water are investigated here in several test cases, characterized by different pipe sizes, bubble dimensions and flow rates, by means of CFD using a Eulerian-Eulerian approach. The performance of models that differ for the turbulence closure in the continuous phase, as well as for the description of the lift force on the dispersed phase, are compared in detail. When air is considered, the space of the experimental parameters leading to a reasonable performance for the selected models are identified and discussed, while the issues left in the modelling of the concurrent condensation are highlighted for the cases where steam is used.

$CO_2$/NOx-free 50kW 매체순환식 가스연소기 산화-환원 연속반응 실증 (Continuous Operation of $CO_2$/NOx-free 50kW Checmial-Looping Combustor)

  • 류호정;진경태;이창근
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2004년도 제28회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.227-234
    • /
    • 2004
  • For gaseous fuel combustion with inherent $CO_2$ capture and low NOx emission, chemical-looping combustion(CLC) may yield great advantages of savings of energy to $CO_2$ separation and suppressing the effect on environment. In chemical-looping combustor, fuel is oxidized by metal oxide medium (oxygen carrier particle) in a reduction reactor. Reduced particles are transported to oxidation reactor and oxidized by air and recycled to reduction reactor. The fuel and the air are never mixed, and the gases from reduction reactor, $CO_2$ and $H_2O$, leave the system as separate stream. The $H_2O$ can be easily separated by condensation and pure $CO_2$ is obtained without any loss of energy for separation. The purpose of this study is to demonstrate inherent $CO_2$ separation and no NOx emission and to confirm high $CO_2$ selectivity, no side reaction (i.e., carbon deposition, hydrogen generation) by continuous reduction and oxidation experiment in a 50kWtb chemical-looping combustor. NiO/bentonite particle was used as a bed material and $CH_4$ and air were used as reacting gases for reduction and oxidation respectively.

  • PDF

미분탄 순산소 연소 운전 모드 전환 과정에 대한 Pilot 규모 설비에서의 실험적 연구 (An Experimental Study on Mode Switching from Air-firing to Oxy-firing in Pilot-scale Combustion Systems)

  • 최종균;나익환;이재욱;채태영;양원;김영주;김종안;서상일
    • 한국연소학회지
    • /
    • 제16권3호
    • /
    • pp.12-20
    • /
    • 2011
  • Oxy-coal combustion for $CO_2$ capture in coal power plants entails a mode switching from air-firing to oxyfiring. In this study, procedure of the mode switching was investigated and discussed through experiments in pilot scale facilities: (1) a 0.3 $MW_{th}$ furnace with a vertical single burner and a FGR(Flue Gas Recirculation) system (2) a 1 $MW_{th}$ furnace with horizontal 4 burners and a FGR system. Principle of the mode switching was established and performed with control of FD fan, FGR fan, ID fan and oxygen flow rates. We have found that equivalence ratio in the oxy-firing mode should be increased more than that in the air-firing to achieve stable mode switching. Control of FD, ID and FGR fans should be performed carefully in the mode switching, in the sense of complete combustion and flame attachment. Moisture contents in the ash and the flue gas recycled to the primary oxidizer stream should be removed to prevent condensation, corrosion and duct clogging.

보조 외부 증발기를 이용한 히트펌프 건조기 성능 향상에 관한 연구 (A Study on Performance Improvement of a Heat Pump Dryer with an Extra Evaporator Outside)

  • 이영림;박상준;황일선
    • 설비공학논문집
    • /
    • 제24권10호
    • /
    • pp.711-717
    • /
    • 2012
  • A heat pump dryer for the frozen food needs to preheat the air to a certain temperature where condensation can efficiently occur. In this study, an analysis of a heat pump dryer performance with operating conditions, an analysis of supplying heat with internal and external evaporators and a warm-up experiment with the evaporators have been performed. The results showed that the external evaporator can significantly accelerate the warm-up time of the dryer, so that it can reduce power consumption greatly. The use of the external evaporator is more efficient for higher ambient temperature. In addition, it was found that COP decreases and the range of evaporating pressure for the evaporator becomes narrower as the condensing temperature of the condenser increases.

천음속 습공기 유동에서 발생하는 충격파와 경계층 간섭의 피동제어에 관한 연구 (A Study of the Passive Shock/Boundary Layer Interaction Control in Transonic Moist Air Flow)

  • 백승철;권순범;김희동
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.161-164
    • /
    • 2002
  • In the present study, a passive control method, using the porous wall and cavity system, is applied to the shock wave/boundary layer interactions in transonic moist air flow. The two-dimensional, unsteady, compressible Navier-Stokes equations, which are fully coupled with a droplet growth equation, are solved by the third-order MUSCL type TVD finite difference scheme. Baldwind-Lomax turbulence model is employed to close the governing equations. In order to investigate the effectiveness of the present control method, the total pressure losses of the flow and the time-dependent behaviour of shock motions are analyzed in detail. The computed results show that the present passive control method considerably reduces the total pressure losses due to the shock/boundary layer interaction in transonic moist air flow and suppresses the unsteady shock wave motions over the airfoil, as well. It is also found that the location of the porous ventilation significantly influences the control effectiveness.

  • PDF

세미-브로잉 공정에서 석유 아스팔트의 구조, 물성 변화 (Structures and Properties of Semi-blown Petroleum Asphalt)

  • 민경의;정한모
    • 공업화학
    • /
    • 제22권6호
    • /
    • pp.664-671
    • /
    • 2011
  • 무촉매 공기 브로잉 공정에서 석유계 감압 잔사유로부터 세미-부로운 아스팔트를 제조하는 경우, 시간에 따른 아스팔트의 조성, 구조, 물리적 성질의 변화를 조사하였다. 공기 브로잉에 의해 지방족 탄화수소 성분이 방향족 탄화수소 성분으로 전이되고, 고분자화 되어 아스팔텐 성분이 증가함을 박막크로마토그래피를 이용한 조성 분석에서 관찰하였다. 처리시간에 따른 방향족화와 고분자화 정도의 증가는 $^1H-NMR$, 열시차분석, 그리고 열중량분석에서도 확인할 수 있었다. 이러한 아스팔트의 조성과 구조의 변화는 침입도의 감소, 연화점과 인화점의 증가를 초래하였다.