A Study on Leakage Characteristics of a Scroll Compressor with alternative Refrigerants of R22 (R22 대체냉매를 적용한 스크롤 압축기의 누설 특성에 관한 연구)

  • Youn, Young;Kim, Yong-Chan;Min, Man-Ki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.5
    • /
    • pp.377-387
    • /
    • 2001
  • This paper presents leakage characteristics of a scroll compressor applying alternative refrigerants of R22 such as R407c and R410a under actual operating conditions. Because leakage in a scroll compressor produce significant losses and degradation of performance, those should be clarified to design a high efficient scroll compressor with alternative refrigerants of R22. However, flank and tip leakage characteristics of a scroll compressor with alternative refrigerants are very limited in open literature. In the present study, both experimentation and modeling of the leakages in the scroll compressor were performed. As a result, it was observed that the leakages of the scroll compressor with R407c increased by 15%, and that with R410a increased by 76% as compared to the compressor applying R22 under standard load conditions due to a higher upstream pressure and a higher pressure difference between pockets.

  • PDF

Performance Improvement of Free Power Gas Turbine Type Gas Turbine Engine by Using of a MAT Cycle (MAT사이클을 이용한 분리축 가스터빈 엔진의 성능향상에 관한 연구)

  • 공창덕;김경두
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.5 no.2
    • /
    • pp.65-72
    • /
    • 2001
  • In order to improve the performance of a free power turbine type gas turbine engine by injecting the atomized water into a compressor inlet., a study on Moisture Air Turbine (MAT) cycle was proposed. Compressor work by air-water mixtures in phase change was theoretically considered, and it was found that the water evaporation might reduce the compressor work. Cycle model calculations predicted that power increments of 16.2%, 14.9% and 12.6% by 1.0% water to the air flow rate at the compressor intake with rotational shaft speeds of 1000, 1210, 1350 rps were obtained, and also thermal efficiency due to the reduction of compressor work was improved.

  • PDF

Transfer Path Analysis of vibration and noise for medical air compressor using PAK system (PAK system 을 이용한 의료용 컴프레서의 진동.소음 전달경로 해석)

  • Kang, Kwi-Hyun;Kang, Jin-Chul;Park, Chun-Kwon;Lee, Jeong-Hwan;Oh, Jae-Eung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.1000-1004
    • /
    • 2008
  • As performance of medical air compressor improve, the problem of noise increased. Noise is very important to medical air compressor because most of this installed inside of building. The main goal of this paper is show TPA (Transfer Path Analysis) result for contribution analysis using PAK system. Generally, the conventional TPA method consists of two steps. First, transfer functions between output sound and sources are measured by excitation experiment. Second, transferred sound in each transfer path is generated by multiplying the transfer function and the sound source signal. Then, if the output sound synthesized from all transferred sounds doesn't give good agreement with the measured output sound (i.e., the accuracies of the transfer functions are low), setting a suitable countermeasure guideline becomes difficult. For obtaining highly accurate transfer functions, eliminating correlations among transfer functions and noise included in the measured data are necessary. In the new method with PAK system, the vibration acceleration and sound signals around the sound sources and the output sound were measured simultaneously to obtain the transfer functions when compressor was operating. By applying PAK system, a highly accurate and efficient transfer path analysis method was developed that does not require an excitation experiment.

  • PDF

Performance Improvement of Free Power Gas Turbine Type Gas Turbine Engine by Using of a MAT Cycle (MAT사이클을 이용한 분리축 가스터빈 엔진의 성능향상에 관한 연구)

  • 공창덕;김경두;기자영;최인수
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2001.04a
    • /
    • pp.54-58
    • /
    • 2001
  • In order to Improve the performance of a free power turbine type gas turbine engine by injecting the atomized water into a compressor inlet., a study on Moisture Air Turbine (MAT) cycle was proposed. Compressor work by air-water mixtures in phase change was theoretically considered, and it was found that the water evaporation might reduce the compressor work. Cycle model calculations predicted that power increments of 21.7%, 20.2% and 18.4% by 1.5% water to the air flow rate at the compressor intake with rotational shaft speeds of 1000, 1210, 1350 rps were obtained, and also thermal efficiency due to the reduction of compressor work was improved.

  • PDF

Performance Comparison of Hot-gas Bypass Types with the Variation of Refrigeration Load (부하변화에 따른 hot-gas 바이패스 방식별 성능 비교)

  • Baek, Seung-Moon;Yoon, Jung-In;Son, Chang-Hyo;Heo, Jung-Ho
    • Journal of Power System Engineering
    • /
    • v.18 no.5
    • /
    • pp.48-54
    • /
    • 2014
  • In this paper, three refrigeration systems bypassing hot-gas to compressor outlet, compressor and condenser outlet and evaporator inlet are theoretically compared to offer basic design data for performance depending on cooling load using a HYSYS program. The main results are summarized as follows : First, the COP of third system is the highest. Next, the COP of second system is higher than first one. And, the temperature of compressor inlet of third system is constant for all cooling load. Compared to first and second system, the compressor inlet temperature of the first system is higher than second one for all cooling loads. From the above results, third system, which is bypassing hot-gas to evaporator inlet, is more advantageous when considering the precise temperature control and excellent performance of oil and water cooler of industrial machine.

Sensor-less Speed Control of PMSM for Driving Oil-free Air Compressor (무급유식 공기압축기 구동을 위한 영구자석 동기 모터의 센서리스 속도제어)

  • Kin, Min Ho;Yang, Oh;Kim, Youn Hyun
    • Journal of the Semiconductor & Display Technology
    • /
    • v.14 no.3
    • /
    • pp.45-50
    • /
    • 2015
  • This paper suggests the sensor-less speed control of PMSM (Permanent Magnet Synchronous Motor) without the position sensor of oil-free air compressor. It estimated d and q axis back electro motive force using Back-EMF (Electro motive Force) observer to control sensor-less speed of PMSM. Also it used the method that tracks the information of rotor position and speed using PLL (Phase Locked Loop) based on estimated d and q axis Back-EMF. The sensor-less speed control of PMSM for oil air compressor application is carried out with the introduced rotor position and speed tracking method. In this paper, the experimental characterization of the sensor-less drive is provided to verify the accuracy of the estimated position and the performance of sensor-less control is analyzed by results obtained from the experiment. Moreover, the potential of PMSM sensor-less drive in industrial application such as compressor drive is also examined.

Development of Performance Analysis Program and the Study of Substitution Refrigerant R1234yf for Vehicle Refrigerant Compressor (차량용 냉매 압축기의 성능 해석 프로그램 개발 및 대체 냉매 R1234yf에 관한 연구)

  • Lee, Tae-Jin;Kim, Ki-Beom;Lee, Seung-Won;Lee, Geon-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.11
    • /
    • pp.699-704
    • /
    • 2011
  • The compressor's efficiency affects on the fuel consumption of the vehicle because the compressors for car air-conditioning system are operated by engine-driven. Especially, the refrigerant is being changed recently from R134a to substitution refrigerant to protect environment pollution that people concerned about. However, that leads to lower efficiency of the car airconditioning system and worse fuel consumption of the vehicle. Thus, this paper is focused on the methods for improvement of the compressor's efficiency that affects on the fuel consumption of the vehicle by numerical analysis for compressor's performance and the measurement of cylinder volume and pressure when the compressor is being operated.

Performance Analysis of Scroll Expander-Compressor Unit for $CO_2$ Transcritical Cycles ($CO_2$ 초임계 사이클을 위한 일체형 스크롤 팽창기-압축기 성능해석)

  • Kim Hyun-Jin;Nam Bo-Young;Ahn Jong-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.5
    • /
    • pp.434-442
    • /
    • 2006
  • In a two-stage compression $CO_2$ transcritical cycle, application of a scroll expander-compressor unit has been considered in order to improve the cycle COP. For both expander and 1st stage compressor, scroll wrap profile which was originally designed for a R410A air-conditioning cycle mechanism was used with minor modifications: wrap height and involute end angle were adjusted for required displacement volume and built-in volume ratio. For pressure condition of 10 Mpa/3.5 MPa and expander inlet temperature of $35^{\circ}C$, 25% improvement in COP was obtained by using expander-compressor unit. As evaporator pressure increased, COP improvement was lowered mainly due to decreasing compressor peformance.

The Experimental Study on Performance Improvement under frost conditions of the Heat Pump with Corrugate Shaped Fin and Two Compressors (저 착상 휜과 두 대 압축기 사이클을 이용한 히트펌프 난방성능 개선에 관한 연구)

  • Hwang Yoon-Jei;Cho Eun-Jun;Chung Baik-Young;Lee Gam-gue
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.3
    • /
    • pp.201-208
    • /
    • 2005
  • This study presents the experimental study on improvement of frost/defrost performance in an heat pump system with newly developed fin and multiple compressors. As multiple compressors system, the variable and single speed compressor combinations has been introduced and compared with single speed 1-compressor system in a view point of improvement of frost/defrost performance. Also, newly developed corrugate shaped fin has been compared with conventional louver shaped fin. The frost/defrost performance is defined and some parameters are compared to discuss the effect of each combination. From this experimental study, it is known that if the variable and single speed compressor combination system equipped with corrugate shaped fin, the system performance has greatly improved not only for heating capacity, but also for frost performance.

A Study on the Noise Reduction Technology for Air-Compressor (공기압축기 소음 저감 기술에 관한 연구)

  • Kim, Bong-Gi;Kim, Jae-Seung;Kim, Hyeon-Sil;Gang, Hyeon-Ju;Kim, Sang-Ryeol
    • 연구논문집
    • /
    • s.33
    • /
    • pp.39-51
    • /
    • 2003
  • This paper deals with the noise measurement and evaluation method of a reciprocating air-compressor and its noise reduction. Lead-wrapping techniques are employed to identify the contribution of principal noise sources which are generally known as motor, belts, suction/discharge valves, moving piston, and flow-induced noise which are caused by edges or discontinuities along the flow path e.g. expansions, contractions, junctions and bends. As a result, it can be found that main noise sources of the air-compressor can be categorized by the suction/discharge noise, valve noise, and compressed-air tank noise. Based on the investigations, mufflers are designed to reduce both the suction/discharge noise and the compressed-air tank noise. Instead of the conventional valve plate, engineering plastics are used as a new one for the reduction of valve impact noise. In addition, attempts are made to reduce the valve noise propagation to the cylinder head and the compressor tank by using the insulation casings in the cylinder head. As a result of the countermeasure plans, it can be achieved that the noise reduction of the air-compress is up to 10 dB.

  • PDF