• 제목/요약/키워드: AgfA

검색결과 13건 처리시간 0.021초

Prediction of the Secondary Structure of the AgfA Subunit of Salmonella enteritidis Overexpressed as an MBP-Fused Protein

  • Won, Mi-Sun;Kim, So-Youn;Lee, Seung-Hwan;Kim, Chul-Jung;Kim, Hyun-Su;Jun, Moo-Hyung;Song, Kyung-Bin
    • Journal of Microbiology and Biotechnology
    • /
    • 제11권1호
    • /
    • pp.164-166
    • /
    • 2001
  • To examine the characteristics of the recombinant thin aggregative fimbriae of Salmonella, the AgfA subunit gene was amplified from Salmonella enteritidis using a PCR. The maltose binding protein (MBP)-AgfA fusion protein was overproduced in E. coli and purified. The secondary structure of AgfA was then elucidated from the difference CD spectra. An estimation of the secondary structure of AgfA using the self-consistent method revealed a mostly ${\beta}-sheet$ structure.

  • PDF

Modified Adaptive Gaussian Filter for Removal of Salt and Pepper Noise

  • Li, Zuoyong;Tang, Kezong;Cheng, Yong;Chen, Xiaobo;Zhou, Chongbo
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제9권8호
    • /
    • pp.2928-2947
    • /
    • 2015
  • Adaptive Gaussian filter (AGF) is a recently developed switching filter to remove salt and pepper noise. AGF first directly identifies pixels of gray levels 0 and 255 as noise pixels, and then only restored noise pixels using a Gaussian filter with adaptive variance based on the estimated noise density. AGF usually achieves better denoising effect in comparison with other filters. However, AGF still fails to obtain good denoising effect on images with noise-free pixels of gray levels 0 and 255, due to its severe false alarm in its noise detection stage. To alleviate this issue, a modified version of AGF is proposed in this paper. Specifically, the proposed filter first performs noise detection via an image block based noise density estimation and sequential noise density guided rectification on the noise detection result of AGF. Then, a modified Gaussian filter with adaptive variance and window size is used to restore the detected noise pixels. The proposed filter has been extensively evaluated on two representative grayscale images and the Berkeley image dataset BSDS300 with 300 images. Experimental results showed that the proposed filter achieved better denoising effect over the state-of-the-art filters, especially on images with noise-free pixels of gray levels 0 and 255.

Impact of MJS treatment and artificial freezing on ground temperature variation: A case study

  • Jiling, Zhao;Ping, Yang;Lin, Li;Junqing, Feng;Zipeng, Zhou
    • Geomechanics and Engineering
    • /
    • 제32권3호
    • /
    • pp.293-305
    • /
    • 2023
  • To ensure the safety of underground infrastructures, ground can sometimes be first treated by cement slurry and then stabilized using artificial ground freezing (AGF) technique before excavation. The hydration heat produced by cement slurry increases the soil temperature before freezing and results in an extension of the active freezing time (AFT), especially when the Metro Jet System (MJS) treatment is adopted due to a high cement-soil ratio. In this paper, by taking advantage of an on-going project, a case study was performed to evaluate the influence of MJS and AGF on the ground temperature variation through on-site measurement and numerical simulation. Both on-site measurement and simulation results reveal that MJS resulted in a significant increase in the soil temperature after treatment. The ground temperature gradually decreases and then stabilized after completion of MJS. The initiation of AGF resulted in a quick decrease in ground temperature. The ground temperature then slowly decreased and stabilized at later freezing. A slight difference in ground temperature exists between the on-site measurements and simulation results due to limitations of numerical simulation. For the AGF system, numerical simulation is still strongly recommended because it is proven to be cost-effective for predicting the ground temperature variation with reasonable accuracy.

회전 효과를 고려한 Active Gurney Flap 의 동특성 해석 (Dynamic Characteristic Analysis of Active Gurney Flap Considering Rotational Effect)

  • 기영중;김태주;김덕관
    • 대한기계학회논문집 C: 기술과 교육
    • /
    • 제3권3호
    • /
    • pp.183-191
    • /
    • 2015
  • 본 논문에서는 헬리콥터 로터 시스템의 진동과 소음을 저감시키기 위해 개발이 진행 중인 능동거니플랩(AGF, Active Gurney Flap)에 대해 유한요소법을 이용하여 수행된 동특성 해석결과를 소개하였다. 거니플랩은 평판의 형태로 블레이드 하부 표면에 수직인 방향으로 전개되며, 블레이드 뒷전(T/E, Trailing Edge) 부위에 장착된다. 거니플랩 조립체는 전기모터와 L-형 링키지 및 플랩 등의 부품들로 구성되어 블레이드 내부에 장착되며, 고정프레임에서의 진동 성분들을 감소시키기 위해 3~5/rev 범위로 능동적인 제어가 필요하다. 따라서 외연적 시간적분법을 통해 로터 회전에 의한 원심력과 제어입력이 적용되고 있는 상황에서 거니플랩의 동적 응답특성을 분석하였으며, 해석 결과를 통해 거니플랩의 하향변위 요구도를 만족시킬 수 있음을 확인하였다.

Experimental and numerical investigation of closure time during artificial ground freezing with vertical flow

  • Jin, Hyunwoo;Go, Gyu-Hyun;Ryu, Byung Hyun;Lee, Jangguen
    • Geomechanics and Engineering
    • /
    • 제27권5호
    • /
    • pp.433-445
    • /
    • 2021
  • Artificial ground freezing (AGF) is a commonly used geotechnical support technique that can be applied in any soil type and has low environmental impact. Experimental and numerical investigations have been conducted to optimize AGF for application in diverse scenarios. Precise simulation of groundwater flow is crucial to improving the reliability these investigations' results. Previous experimental research has mostly considered horizontal seepage flow, which does not allow accurate calculation of the groundwater flow velocity due to spatial variation of the piezometric head. This study adopted vertical seepage flow-which can maintain a constant cross-sectional area-to eliminate the limitations of using horizontal seepage flow. The closure time is a measure of the time taken for an impermeable layer to begin to form, this being the time for a frozen soil-ice wall to start forming adjacent to the freeze pipes; this is of great importance to applied AGF. This study reports verification of the reliability of our experimental apparatus and measurement system using only water, because temperature data could be measured while freezing was observed visually. Subsequent experimental AFG tests with saturated sandy soil were also performed. From the experimental results, a method of estimating closure time is proposed using the inflection point in the thermal conductivity difference between pore water and pore ice. It is expected that this estimation method will be highly applicable in the field. A further parametric study assessed factors influencing the closure time using a two-dimensional coupled thermo-hydraulic numerical analysis model that can simulate the AGF of saturated sandy soil considering groundwater flow. It shows that the closure time is affected by factors such as hydraulic gradient, unfrozen permeability, particle thermal conductivity, and freezing temperature. Among these factors, changes in the unfrozen permeability and particle thermal conductivity have less effect on the formation of frozen soil-ice walls when the freezing temperature is sufficiently low.

액화질소를 이용한 인공동결공법 적용시 해성 점토지반의 동결속도 평가 (Evaluation of Freezing Rate of Marine Clay by Artificial Ground Freezing Method with Liquid Nitrogen)

  • 최현준;이동섭;이효범;최항석
    • 대한토목학회논문집
    • /
    • 제38권4호
    • /
    • pp.555-565
    • /
    • 2018
  • 최근 임시 지보, 보강 및 지하수 차수와 같은 다양한 지질공학분야에서 차수 및 지반보강 공법으로 인공동결공법(artificial ground freezing method)이 적용되고 있다. 인공동결공법은 지중에 매설된 동결관 내로 냉매를 순환시켜 대상 지반에 차수벽 및 지지체의 역할을 할 수 있는 동결벽체(frozen wall)를 형성한다. 본 연구에서는 해성 점토지반(marine clay)에 대한 인공동결공법 현장실증시험을 수행함으로서 인공동결공법에 따른 해성 점토지반에서의 동결속도(freezing rate)를 평가하였다. 현장실증시험은 지중에 3.2m 깊이로 매설된 동결관 내로 초저온 냉매인 액화질소를 순환시키는 방법으로 단일공 시험과 동결벽체 형성 시험을 수행하였다. 자동밸브를 통해 유출되는 액화질소의 온도를 일정하게 유지시켰으며, 동결과정에서 동결관 외벽 및 지중의 온도변화를 측정하였다. 시험결과, 단일공 시험은 부피가 약 $2.12m^3$인 원기둥 모양의 동결체를 형성하는데 총 3.5일 동안 약 11.9ton의 액화질소가 소요되었고, 동결벽체 형성 시험은 부피 약 $7.04m^3$의 동결벽체를 형성하는데 총 4.1일 동안 약 18ton의 액화질소가 소요된 것으로 산정되었다. 임의의 깊이에서 동결면적이 동결반경의 제곱에 비례하기 때문에 동결반경이 증가할수록 방사방향 1차원 동결속도가 감소하였고, 이를 바탕으로 방사방향 1차원 동결속도 예측식을 제시하였다.

인공동결공법 적용 후 융해에 따른 해성 점토지반의 역학적 특성 평가 (Evaluation of mechanical characteristics of marine clay by thawing after artificial ground freezing method)

  • 최현준;이동섭;이효범;손영진;최항석
    • 한국터널지하공간학회 논문집
    • /
    • 제21권1호
    • /
    • pp.31-48
    • /
    • 2019
  • 인공동결공법(artificial ground freezing method)은 연약지반 및 도심지에서의 지하구조물 시공에 적합한 차수 및 지반보강 공법이다. 인공동결공법은 동결관(freezing pipe)을 지중에 매설한 후 냉매(refregerant)를 순환시켜 대상 지반에 차수벽 및 지지체의 역할을 수행하는 동결벽체(frozen wall)를 형성한다. 그러나 간극수의 동결에 따른 간극수의 부피팽창은 지반의 변형을 야기시킬 수 있고, 시공완료 후 동결토의 융해에 따른 지반의 소성변형 및 입자의 재배치 등은 지반의 역학적 특성을 변화시킨다. 본 논문에서는 인공동결공법에 따른 해성 점토지반(marine clay)의 동결속도를 평가하기 위하여 인공동결공법 현장실증시험을 수행하였다. 현장실증시험은 지중에 3.2 m 깊이로 매설된 동결관 1공 내로 초저온 냉매인 액화질소를 순환시키는 방법으로 수행되었다. 또한, 원지반과 인공동결공법에 의해 동결/융해된 지반에 대한 피에조 콘 관입시험(piezo cone penetration test, CPTu) 및 공내재하시험(lateral load test, LLT)을 수행함으로써 동결/융해(freezing-thawing)에 따른 해성 점토지반의 강도 및 강성 특성의 변화를 평가하였다. 시험결과, 부피가 약 $2.12m^3$인 원기둥 모양의 동결체를 형성하는데 총 3.5일이 동안 약 11.9 ton의 액화질소가 소요되었다. 동결/융해에 따른 지반의 강도 및 강성 저하는 각각 48.5%, 22.7%로 산정되었다.

얼음벽 형성에 대한 지하수 흐름의 영향 (Effect of Groundwater Flow on Ice-wall Integrity)

  • 신호성;김진욱;이장근
    • 한국지반공학회논문집
    • /
    • 제34권11호
    • /
    • pp.43-55
    • /
    • 2018
  • 인공동결공법은 일시적으로 지반의 강성을 높이고 투수계수를 낮추는 지반개량공법으로 지반에 적용가능하다. 하지만, 지하수 흐름과 지반의 불균질성은 동결구근 형성을 불확실하게 하여 공법에 대한 신뢰성을 저해한다. 동결지반 대한 열-수리 유한요소 해석 프로그램을 이용하여, 인공동결공법에서 지하수 흐름속도와 지반의 층상 비균질이 얼음벽 형성을 미치는 영향을 분석하였다. 지하수의 흐름은 원형의 동결구근을 원형에서 타원형을 변형시키며 얼음벽의 완성 소요시간을 증가시킨다. 기존의 이론식은 인접 동결구근의 열적 상호작용을 무시하여, 얼음벽의 완결시간과 한계유속을 과대 평가하였다. 수치해석 결과를 바탕으로 수정식을 제시하였으며 무차원 얼음벽 완결시간에 대한 제안식을 검증하였다. 층상의 비균질 지반에서 투수계수가 큰 지층의 두께와 상대적인 투수계수비는 얼음벽 완결시간과 한계 유속에 중요한 인자인 것으로 나타났다.

천해용 Side Scan Sonar의 송수신 시스템 구현 및 운용에 관한 연구 (Development of a Side Scan Sonar System for Underwater Sun)

  • 오영석;이철원;강도욱;우종식
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2000년도 추계학술대회 논문집
    • /
    • pp.222-227
    • /
    • 2000
  • "Side scan sonar" using acoustic signal has been developed to survey cable laying, sunken bodie\ulcorner bottom and so on. It use the acoustic signals, which are emitted from two transducer arrays, to get gemetri\ulcorner target area. This system consists of transceiver board, towed body, and deck unit. The transceiver board, w\ulcorner watertight canister of the towed body, controls the transmitting and receiving of 400kHz acoustic signals from \ulcorner After receiving the scattered signals, it processes the filtering, AGF(Automatic Gain Control), TVG(Time Heterodyne. The deck unit is composed of the signal processing part, A/D converter, power supplier, and real\ulcorner And the towed body has been designed to satisfy the optimal hydrodynamic behavior during towing. The de\ulcorner theory of transceiving part and some results from field-experiments will be introduced here.

  • PDF