• Title/Summary/Keyword: AgCl

Search Result 531, Processing Time 0.021 seconds

Determination of Bio-Accumulated Trace Mercury by Anodic Stripping Square Wave Voltammetry at Glassy Carbon Electrode (유리질 탄소전극에서 양극벗김 네모파 전압-전류법에 의한 생체내 미량 수은의 정량)

  • Kim, Il Kwang;Chun, Hyun Ja;Jeong, Seung Il;Beck, Seung Hwa;Han, Wan Soo
    • Journal of the Korean Chemical Society
    • /
    • v.45 no.4
    • /
    • pp.298-303
    • /
    • 2001
  • The trace-level mercury in bio-materials has been determinated by the anodic stripping square wave voltammetry (ASSWV)-technique at glassy carbon electrode. Prior to the analysis, the bio-materials were digested with $HNO_3/H_2SO_4$ mixture and KMnO4 was added to complete an oxidation process of the mixture. The detection limit of the mercury varied greatly with deposition time, deposition potential, pH and stirring rate. When the deposition was carried out for 240 sec on 400 rpm stirring at -1.0 volts vs. Ag/AgCl, the detection limit was below 0.5 ppb ($2.5{\times}10^{-9}M$). The accumulated mercury was high in the kidney and liver, and low in the brain according to the determination of mercury accumulation for a white rat by this method.

  • PDF

Amperometric Enzyme Electrode for the Determination of $NH_4^+$ ($NH_4^+$ 정량을 위한 Amperometric Enzyme Electrode)

  • Moo Lyong Seo;Jae Sang Kim;Shim Sung Lee;Zun Ung Bae;Heung Lark Lee;Tae Myung Park
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.11
    • /
    • pp.937-942
    • /
    • 1993
  • Enzyme electrodes for amperometric measurement of ammonia was prepared by immobilization of L-glutamate dehydrogenase on an Immobilon-AV Affinity membrane and attachment to a glassy carbon electrode. Reduced nicotinamide adenine dinucleotide (NADH) was used as the electroactive species. The electrochemical oxidation of NADH was monitored at +1.0 volt vs. Ag/AgCl. Response was linear from $4.0\;{\times}\;10^{-5}\;to\;4.0\;{\times}\;10^{-4}$ M. The detection limit was 2.0 ${\times}\;10^{-6}$ M. Response time, the optimum pH and life time of enzyme immobilized membrane were 2 min, pH 7.3∼7.6 (Dulbecco's buffer solution) and about 25 days respectively. When the enzyme electrode was applied to the $NH_4^+$ determination with amperometric method, other physiological materials had no interference.

  • PDF

Amperometric Biosensor for Hydrogen Peroxide Determination Based on Black Goat Liver-Tissue and Ferrocene Mediation (흑염소 간-조직과 Ferrocene 매개체를 사용한 과산화수소정량 전류법 바이오센서)

  • Kwon, Hyo-Shik;Park, In-Keun;Kim, Yang-Sug
    • Journal of the Korean Chemical Society
    • /
    • v.48 no.5
    • /
    • pp.491-498
    • /
    • 2004
  • The response characteristics of the bioelectrode developed by the co-immobilization of black goat liver tissue and ferrocene in a carbon paste matrix for the amperometric determination of hydrogen peroxide were evaluated. In the range of electrode potential examined ($-0.3{\sim}+0.0\;V$ vs. Ag/AgCl), the response time was relatively short (t95%=12 s) and it responded in the wide range of pH. The detection limit was 2.25${\times)10^{-6}M$ and a relative standard deviation of the measurements which were repeated 15 times using 1.0${\times}10^{-2 }$M hydrogen peroxide was 1.87%. The bioelectrode sensitivity decreased to 50% of the original value in 19 days of continuous use.

Regeneration of PCB Etchants and Copper Recovery in a Batch-type Electrolytic Cell (회분식 전해조에서 PCB 식각폐수의 재생 및 구리의 회수)

  • Nam, Sang Cheol;Nam, Chong Woo;Tak, Yongsug;Oh, Seung Mo
    • Applied Chemistry for Engineering
    • /
    • v.8 no.2
    • /
    • pp.161-171
    • /
    • 1997
  • Anodic regeneration of PCB enchant and cathodic deposition of copper using electrochemical method has been studied. Cu(I)/Cu(II) concentration ratio as a function of Cu(I) oxidation at the anode was measured from the potential difference between platinum and Ag/AgCl/4M KCl electrodes. Chlorine gas evolution was minimized by maintaining Cu(I) concentration above a specific concentration and using non-porous graphite electrode. Dendritic copper deposition was observed at the cathode and the optimum conditions for Cu deposition was identified as the current density of $360mA/cm^2$, and copper concentration of 12 g/l. Titanium was the most effective cathode material which showed a higher current efficiency and copper recovery. The current efficiency decreased with increasing temperature, but the highest power efficiency was achieved at $50^{\circ}C$.

  • PDF

Determination of Uranium using 1-(2-Pyridylazo)-2-naphthol by Adsorptive Stripping Voltammetry (1-(2-Pyridylazo)-2-naphthol을 이용한 우라늄의 흡착벗김전압전류법적 정량)

  • Kim, Kyoung Tae;Choi, Won Hyung;Lee, Jin Sik;Choi, Sung Yung
    • Analytical Science and Technology
    • /
    • v.8 no.3
    • /
    • pp.285-292
    • /
    • 1995
  • Uranium has variable oxidation states(${UO_2}^{+2}$, $UO^{+2}$, $U^{+4}$, $U^{+3}$) and 1-(2-Pyridylazo)-2-naphthol forms a very stable chelate with Uranium(${UO_2}^{+2}$). The determination method of Uranium(${UO_2}^{+2}$) in 0.1M Borate buffer(pH 7.10) has been investigated by adsorptive stripping voltammetry. The optimum conditions were PAN concentration of $5{\times}10^{-7}M$, accumulation potential of 0.00V(vs. Ag/AgCl) and accumulation time of 120sec. The calibration curve was linear over the range of $5{\sim}60{\mu}g/L$ and the various metal ions did not interfere with the determination Uranium(${UO_2}^{+2}$) except Cu(II) and Co(II).

  • PDF

Synthesis and Electrochemical Characteristics of Rare Earths Metal Complexes (희토류금속 착물의 합성과 전기화학적 특성)

  • Chil Nam Choe;Suk Jin Yuon;Il Du Kim;Sung Pyung Kim;Youn Soo Sohn
    • Journal of the Korean Chemical Society
    • /
    • v.33 no.5
    • /
    • pp.496-503
    • /
    • 1989
  • The chemical behavior of trivalent lanthanide (Pr(III) and Yb(III)) and 2, 2, 6, 6-tetramethyl-3, 5-heptanedione(dipivaloylmethane) complexes was investigated by the use of direct current, differential pulse polarography and cyclic voltammetry. In this study, it was founded that the reduction of trivalent lanthanide complexes was observed by one electron transfer process at Epc = -0. 13 V and -0.80 V of Pr(III), and -0.02 V of Yb(III) vs. Ag-AgCl electrode. Also, it was founded that the treatment of DP and CV to the case of a first-order chemical equilibrium reaction preceding a reversible and irreversible one electron transfer reaction, (a >0. 5) the socalled ErCr electrode process. The equilibrium constant (lnK) obtained, of various solvents, these constant were founded to be increases with decreasing dielectric constant of the solvents. Plots of lnK for these reaction against ln(l/D) for the solvents was fairly straight lines, and the behavior of the heavier lanthanides was decreased equilibrium constant with increasing atomic number.

  • PDF

Simultaneous Determination of Zinc, Cadmium, Lead and Copper in Tungsten Matrix by Differential Pulse Anodic Stripping Voltammetry (펄스차이 벗김전압전류법에 의한 텅스텐 중 아연, 카드뮴, 납 및 구리의 미량성분 동시분석)

  • Bae, Jun Ung;Lee, Seong Ho
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.2
    • /
    • pp.146-150
    • /
    • 1994
  • The simultaneous determination of Zn, Cd, Pb and Cu in 1.000%(w/v) tungsten matrix by differential pulse anodic stripping voltammetry at a hanging mercury drop electrode has been studied. Tartaric acid(pH=5.00) was used as a supporting electrolyte. Optimum analytical conditions were found that the deposition potential was -1.2 volt(vs. Ag/AgCl), the deposition time was 3 minutes. The linear concentration range of all trace metal ions in 1.000%(w/v) tungsten matrix were 10 to 50 ppb. And the detection limit(3${\sigma}$) of zinc, cadmium, lead and copper were 1.25, 1.02, 1.69, and 1.02 ppb respectively. This method was superior to the ICP-AES method which detection limits(3${\sigma}$) in 1.000%(w/v) tungsten matrix were 8.0, 5.0, 120 and 5 ppb respectively.

  • PDF

Square-Wave Anodic Stripping Voltammetric Study of Germanium(Ⅳ)-Morin Complex (Germanium(Ⅳ)-Morin 착물에 대한 네모파 양극벗김 전압전류법적 연구)

  • Sohn, Se Chul;Park, Yong Joon;Joe, Kih Soo
    • Journal of the Korean Chemical Society
    • /
    • v.41 no.11
    • /
    • pp.590-593
    • /
    • 1997
  • Square-wave anodic stripping voltammetry was applied to the germanium(IV)- Morin complex in 0.5 M sulfuric acid as a supporting electrolyte. The peak potential appeared at - 0.606 V vs. Ag/AgCl. Effects of sulfuric acid concentration, Morin concentration, accumulation potential, and accumulation time on the stripping peak current for the complex of germanium(IV)-Morin were studied. Interferences by other metal cations that affect on stripping peak current were also investigated. The detection limit was found to be $3.76{\times}10^{-7}M(27 {\mu}g/L)$ for germanium(IV) using 60 seconds of accumulation time. The relative standard deviation (n=8) for 0.4 mg/L($5.5{\times}10^{-6}$ M) germanium(IV) was 3.2%.

  • PDF

Electrochemical Characterization of Stainless Steel in Ethanolamine Solution Containing an Alkyl Group using Cyclic Voltammetry (순환전압전류법에 의한 알킬기를 함유한 에탄올아민용액에서 스테인리스의 전기화학적 특성)

  • Park, Keun-Ho
    • Journal of the Korean Applied Science and Technology
    • /
    • v.31 no.1
    • /
    • pp.66-73
    • /
    • 2014
  • In this work, the current-voltage curves for stainless steel in the ethanolamine solution containing alkyl group were measured using the conventional three electrodes of cyclic voltammetry. Stainless steel as working electrode, Ag/AgCl electrode as reference electrode and Pt wire as counter electrode were used respectively. As a result, the C-V characteristics of stainless steel were to be for an irreversible process due to the oxidation current from cyclic voltammogram, using N-ethylethanolamine and N,N-dimethylethanolamine solutions. Effective diffusivity of corrosion inhibitors was decreased with increasing concentration. It was found from SEM images of the metal that the electrolyte (specific name ?)(0.5 N) as corrosion inhibitor was added into a N, N-diethylethanolamine solution ($1.0{\times}10^{-3}M$) containing copper and nickel, the corrosion inhibiting effect was enhanced.

Differential Pulse Voltammetric Determination of Iron(II) ion with a Nafion-Ethylenediamine Modified Glassy Carbon Electrode (Nafion-ethylenediamine이 수식된 유리탄소전극에 의한 시차펄스전압전류법으로 철(II) 이온의 정량)

  • Kyong Wone Kim;Hee Cheol Kim;Sung-Hyun Kim;Byung Ho Park;Yeon Hee Kim;Kyong Nam Kim;Yong Chun Ko
    • Journal of the Korean Chemical Society
    • /
    • v.47 no.2
    • /
    • pp.115-120
    • /
    • 2003
  • Determination of iron(II) ion with a perfluorinated sulfonated polymer(nafion)-ethylenediamine(en) modified glassy carbon electrode was studied. It was based on the chemical reactivity of an immobilized layer(nafion-en) to yield complex $[Fe(en)_3]^{+2}$. The oxidation peak potential by differential pulse voltammetry(DPV) was observed at 0.340${\pm}$0.015 V(vs. Ag/AgCl). The linear calibration curve was obtained in iron(II) ion concentration range $5{\times}10^{-6}{\sim}0.2{\times}10^{-3} M(0.28{\sim}11.17\; mg/L)$, and the detection limit(3s) was $1.89{\times}10^{-5}$M(1.056 mg/L).