• 제목/요약/키워드: Ag ion

검색결과 411건 처리시간 0.028초

A New Cone Shaped Asymmetrically Substituted Calix[4]arene as an ExcellentIonophore in Construction of Ag(I) ion-Selective Membrane Electrode

  • Ganjali, Mohammad Reza;Babaei, Leila Hajiagha;Taghvaei-Ganjali, Saeed;Modjallal, Atoosa;Sahmsipur, Mojtaba;Hosseini, Morteza;Javanbakht, Mehran
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권2호
    • /
    • pp.177-181
    • /
    • 2004
  • A PVC membrane electrode for silver ion based on a new cone shaped calix[4]arene (CASCA) as membrane carrier was prepared. The electrode exhibits a Nernstian response for $Ag^+$ over a wide concentration range ($1.0{\times}10^{-1}-8.0{\times}10^{-6}$M) with a slope of 58.2 {\pm}$ 0.5 mV per decade. The limit of detection of the sensor is $5.0{\times}10^{-6}$M. The sensor has a very fast response time (~5 s) in the concentration range of ${\leq}=1.0{\times}10^{-3}$ M, and a useful working pH range of 4.0-9.5. The proposed sensor displays excellent discriminating ability toward $Ag^+$ ion with respect to common alkali, alkaline earth, transition and heavy metal ions. It was used as an indicator electrode in potentiometric titration of $Ag^+$ with EDTA and in direct determination of silver ion in wastewater of silver electroplating.

황산동전해액(黃酸銅電解液) 중 은(銀(Ag)) 제거(除去)를 위한 연구(硏究) (A Study on the Removal of Silver in Copper Electrolyte)

  • 소순섭;안재우
    • 자원리싸이클링
    • /
    • 제17권5호
    • /
    • pp.60-65
    • /
    • 2008
  • 고순도 동 제조를 위해 황산동 전해액중에 존재하는 은(Ag)을 제거하기 위한 기초연구를 실시하였다. 이온교환수지법, 활성탄 흡착법, 구리분말 및 세선을 이용한 치환법, CuS침전법 등을 이용하여 Ag제거에 대한 실험을 실시하였으며, 은(Ag)제거 반응에 영향을 미칠 수 있는 반응온도, 반응시간, 첨가량 등에 대해 고찰하였다. 이들 방법중 CuS 침전법과 Lewatit TP214를 이용한 이온교환수지 방법이 효과적이었는데 특히 Lewatit TP214를 사용한 경우 초기 동전해액중, Ag 농도가 10ppm서 0.1ppm 이하 수준까지 제거가 가능하였다.

1,5,9,13-Tetrathiacyclohexadecane 수식전극을 사용한 Ag(I)의 전기화학적 정량 (Electrochemical Determination of Ag(I) Ion at Chemically Modified Carbon-Paste Electrode Containing 1,5,9,13-Tetrathiacyclohexadecane)

  • 하광수;장미경;서무룡
    • 분석과학
    • /
    • 제10권3호
    • /
    • pp.187-195
    • /
    • 1997
  • [16]-ane-$S_4$/탄소분말 함량비를 50%로 하여 nujol oil과 혼합하여 수식전극을 제조하였다. $5.0{\times}10^{-4}M$ $Ag^+$를 포함하는 pH 4.5인 아세트 완충용액에 수식전극을 담가 $Ag^+$를 전극 표면에 흡착시켰다. 이 때 흡착시간을 15분으로 하고 전해환원시키는 시간은 -0.3V vs S.C.E에서 2분으로 하였다. 또한 0.1M $HNO_3$ 용액으로 전극을 활성화시켰으며 한번 활성화한 전극은 10회까지 사용이 가능하였다. 최적 분석조건에서 미분펄스 전압전류법으로 $5.0{\times}10^{-7}{\sim}1.5{\times}10^{-6}M$ 사이의 농도 범위에서 정량해 보았을 때 직선성이 잘 성립하였으며, 검출한계는 $2.0{\times}10^{-7}M$이었다. 대부분의 금속들은 방해를 주지 않았으나, Cu(II)은 방해를 나타내었다.

  • PDF

이온교환된 제올라이트 흡착제의 질소 및 산소 흡착 특성 연구 (A Study on the Adsorption Characteristics of Nitrogen and Oxygen on Ion Exchanged Zeolite Adsorbents)

  • 정헌도;김동식;김권일
    • 공업화학
    • /
    • 제16권1호
    • /
    • pp.123-130
    • /
    • 2005
  • 산소 PSA용 흡착제의 제조를 위하여 표면적이 큰 제올라이트 X형 흡착제를 합성하고 양이온교환을 통하여 질소의 선택적 흡착 능력이 우수한 흡착제로 제조하였다. 제올라이트 X형 흡착제는 50 L급 대형 반응기에서 $SiO_2\;:\;Na_2O\;:\;H_2O\;:\;Al_2O_3$ = 2.5 : 3.5 : 150 : 1의 조성으로 $98^{\circ}C$, 18 h 동안 반응한 결과 표면적이 $650m^2/g$ 이상의 표면적을 나타내었다. 흡착제의 양이온교환은 Li, Ag, Ca, Br, Sr 등의 금속 이온을 대상으로 조사하였다. Ag 이온의 이온교환 속도가 가장 빠르게 일어났으며 모든 금속 이온이 제올라이트 X형에 포함된 Na 이온과 거의 당량적으로 이온 교환이 일어남을 알 수 있었다. 양이온 교환된 제올라이트 X형 흡착제의 질소와 산소의 흡착 성능을 $10{\sim}40^{\circ}C$, 0~9 atm의 범위에서 측정한 결과 이온교환을 하지 않은 NaX 흡착제에 비하여 월등히 높은 흡착 성능을 나타내었으며 이온 교환된 제올라이트 X형 흡착제의 질소 흡착량은 0.5 atm 이하의 저압에서는 Ag > Li > Ca > Sr > Ba > K 이온의 순으로 나타났으나 1 atm 이상의 고압에서는 Li > Ag > Ca > Sr > Ba > K 이온의 순으로 나타났다. 공기의 조성에 준하는 질소 및 산소의 분압에서 흡착량의 비를 조사하여 질소/산소 분리도를 측정한 결과 $20^{\circ}C$의 온도에서 Li으로 이온 교환된 흡착제의 분리도는 13.023을 나타내었다.

Ag(Ⅰ) 이온 선택성을 갖는 거대고리 리간드: 벤질 치환기를 갖는 질소-산소 주개 거대고리 리간드의 착물 형성과 액체막 이동 현상 (Ag(Ⅰ) Ion Selective Macrocyclic Ligands: The Complexation and Liquid Membrane Transport Phenomena of Benzylated Nitrogen-Oxygen Donor Macrocyclic Ligands)

  • 김정;안태호;이명노;조문환;김시중
    • 대한화학회지
    • /
    • 제43권2호
    • /
    • pp.167-171
    • /
    • 1999
  • 벤질 치환기를 포함하는 질소-산소 혼합 주개 거대고리 리간드와 Co(II), Ni(II), Cu(II), Zn(II), Cd(II), Pb(II) 그리고 Ag(I)와의 상호작용에 관한 연구를 수행하였다. 95% 메탄올 용액에서 각 착물의 안정도 상수를 전위차 적정법을 통해 결정하였으며 또한 이들 거대고리 리간드를 포함하는 액체막을 통하여 금속 이온의 이동을 조사하였다. 그 결과 Cu(II)와 Ag(I) 이온의 경우만 사용한 두 리간드와 안정한 착물을 형성하는 것으로 조사되었으며 액체막 이동 실험에서는 Ag(I) 이온의 선택적 이동이 일어남을 확인하였다.

  • PDF

A New PVC-Membrane Electrode Based on a Thia-Substituted Macrocyclic Diamide for Selective Potentiometric Determination of Silver Ion

  • Shamsipur, Mojtaba;Kazemi, Sayed Yahya;Niknam, Khodabaksh;Sharghi, Hashem
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권1호
    • /
    • pp.53-58
    • /
    • 2002
  • A new PVC-membrane electrode for $Ag^+$ ion based on a thia-substituted macrocyclic diamide has been prepared. The electrode exhibited a Nernstian response for $Ag^+$ over a wide concentration range $(1.7{\times}10^{-6}-1.0{\times}10^{-1}M)$. It has a response time <15 s and can be used for at least 3 months without divergence. The proposed membrane sensor revealed good selectivities for $Ag^+$ over a variety of metal ions and can be used in a pH range 3.0-7.5. It has been used successfully for direct determination of $Ag^+$ in different real samples and, as an indicator electrode, in the titration of silver ion.

이온교환 방법에 의한 유리도파로 특성 고찰 (The Discussion of Glass Waveguide formed by ton-exchange)

  • 박정일;김봉재;박태성;정흥배
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1994년도 춘계학술대회 논문집
    • /
    • pp.130-132
    • /
    • 1994
  • We fabricated Ag ion exchange glass waveguide. Generally, ion-exchange glass waveguide. are suitable for passive integrated optical components such as directional and star couplers. Its advantages include low loss, ease of fabrication, and low material cost. So, we faricated Ag ion-exchange glass waveguides in AgNO$_3$ melt solution from 2 mole %. And we used Sodalime glass as a substrate in the fabrication process. As the results, we observed multivalent ion-exchange in a typical sodalime glass. Diffusion coefficient and depth are predicted by actual experimental data of Stewart. The exchange rate in silver-ion-exchanged waveguides are compared to the exchange time of waveguide fabrication.

  • PDF

습식 화학적 환원법에 의한 AgNO3로부터 Ag 분말의 제조 1. 균일한 구형 Ag 분말의 제조를 위한 최적 반응계 확립 (Preparation of Ag Powder from AgNO3 by Wet Chemical Reduction Method1. The Establishment of Optimum Reaction System for the Preparation of Spherical Ag Powder)

  • 윤기석;박영철;양범석;민현홍;원창환
    • 한국분말재료학회지
    • /
    • 제12권1호
    • /
    • pp.56-63
    • /
    • 2005
  • Ag powder was prepared from $AgNO_3$ by wet chemical reduction method using various reduction agent system involving $AgNO_3$, $AgNO_2$(AgCl) and Ag complex ion aqueous solution. The pure Ag powder could be prepared regardless of reaction system but the particle shape and distribution were affected very much according to the kind of reduction agents and reaction systems. The optimum reaction system for the preparation of the silver powder having the uniform particle shape and size distribution was Ag complex ion aqueous solution-reduction agent system and in particular, $H_2O_2$ and $C_6H_8O_6$as a reduction agent leaded the more uniform particle shape and size distribution.

Ag$^{+}$ -Na$^{+}$이온교환법을 이용한 BK7 유리 평판형 광도파로의 특성 (Characterization of Planar Optical Waveguides by Ag$^{+}$ -Na$^{+}$ Ion Exchange in BK7 Glass)

  • 전금수;반재경
    • 전자공학회논문지D
    • /
    • 제35D권1호
    • /
    • pp.84-93
    • /
    • 1998
  • Planar graded index optical waveguides have been formed by Ag$^{+}$ ion exchange in the BK7 optical glass. The experimental results of diffusion and modal characteristics of Ag$^{+}$-Na$^{+}$ exchanged BK7 glass waveguides are presented. Measurements of the mode indices have been measured. We found the relations between the process and device parameters such as the diffusion depth and the square root of the diffusion time, diffusion coefficient and diffusion temperature, and diffusion ion concentration and surface index change. A theoretical gaussian function refractive index profile matched best with the measured data for all the guided modes. The empirical relations between the process and the device parameters are derived and subsequently used to formulate a systematic procedure for fabricating singlemode and multimode waveguides.uides.