• Title/Summary/Keyword: Advanced material

Search Result 4,162, Processing Time 0.04 seconds

Carbon nanotube field emission display

  • Chil, Won-Bong;Kim, Jong-Min
    • Electrical & Electronic Materials
    • /
    • v.12 no.7
    • /
    • pp.7-11
    • /
    • 1999
  • Fully sealed field emission display in size of 4.5 inch has been fabricated using single-wall carbon nanotubes-organic vehicle com-posite. The fabricated display were fully scalable at low temperature below 415$^{\circ}C$ and CNTs were vertically aligned using paste squeeze and surface rubbing techniques. The turn-on fields of 1V/${\mu}{\textrm}{m}$ and field emis-sion current of 1.5mA at 3V/${\mu}{\textrm}{m}$ (J=90${\mu}{\textrm}{m}$/$\textrm{cm}^2$)were observed. Brightness of 1800cd/$m^2$ at 3.7V/${\mu}{\textrm}{m}$ was observed on the entire area of 4.5-inch panel from the green phosphor-ITO glass. The fluctuation of the current was found to be about 7% over a 4.5-inch cath-ode area. This reliable result enables us to produce large area full-color flat panel dis-play in the near future. Carbon nanotubes (CNTs) have attracted much attention because of their unique elec-trical properties and their potential applica-tions [1, 2]. Large aspect ratio of CNTs together with high chemical stability. ther-mal conductivity, and high mechanical strength are advantageous for applications to the field emitter [3]. Several results have been reported on the field emissions from multi-walled nanotubes (MWNTs) and single-walled nanotubes (SWNTs) grown from arc discharge [4, 5]. De Heer et al. have reported the field emission from nan-otubes aligned by the suspension-filtering method. This approach is too difficult to be fully adopted in integration process. Recently, there have been efforts to make applications to field emission devices using nanotubes. Saito et al. demonstrated a car-bon nanotube-based lamp, which was oper-ated at high voltage (10KV) [8]. Aproto-type diode structure was tested by the size of 100mm $\times$ 10mm in vacuum chamber [9]. the difficulties arise from the arrangement of vertically aligned nanotubes after the growth. Recently vertically aligned carbon nanotubes have been synthesized using plasma-enhanced chemical vapor deposition(CVD) [6, 7]. Yet, control of a large area synthesis is still not easily accessible with such approaches. Here we report integra-tion processes of fully sealed 4.5-inch CNT-field emission displays (FEDs). Low turn-on voltage with high brightness, and stabili-ty clearly demonstrate the potential applica-bility of carbon nanotubes to full color dis-plays in near future. For flat panel display in a large area, car-bon nanotubes-based field emitters were fabricated by using nanotubes-organic vehi-cles. The purified SWNTs, which were syn-thesized by dc arc discharge, were dispersed in iso propyl alcohol, and then mixed with on organic binder. The paste of well-dis-persed carbon nanotubes was squeezed onto the metal-patterned sodalime glass throuhg the metal mesh of 20${\mu}{\textrm}{m}$ in size and subse-quently heat-treated in order to remove the organic binder. The insulating spacers in thickness of 200${\mu}{\textrm}{m}$ are inserted between the lower and upper glasses. The Y\ulcornerO\ulcornerS:Eu, ZnS:Cu, Al, and ZnS:Ag, Cl, phosphors are electrically deposited on the upper glass for red, green, and blue colors, respectively. The typical sizes of each phosphor are 2~3 micron. The assembled structure was sealed in an atmosphere of highly purified Ar gas by means of a glass frit. The display plate was evacuated down to the pressure level of 1$\times$10\ulcorner Torr. Three non-evaporable getters of Ti-Zr-V-Fe were activated during the final heat-exhausting procedure. Finally, the active area of 4.5-inch panel with fully sealed carbon nanotubes was pro-duced. Emission currents were character-ized by the DC-mode and pulse-modulating mode at the voltage up to 800 volts. The brightness of field emission was measured by the Luminance calorimeter (BM-7, Topcon).

  • PDF

A Study on the Transformation of Traditional Laboratories into Instructional Media Centers for Education of Library and Information Science (문헌정보학 실습실의 교수매체 센터화에 관한 연구)

  • Lee, Man-Soo
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.34 no.1
    • /
    • pp.265-295
    • /
    • 2000
  • Education of library and information science must focus on practical education acted upon as a laboratory room in the characteristics of learning, because it cultivates a librarian as an information expert who can conduct professional affairs and services, applying traditional theory to the practical business of library and information. This dissertation suggested a new paradigm of an instructional media center as an advanced laboratory room which faithfully can run the curriculum of a library and information science for cultivating librarians, information experts who can satisfy the 21C information society. To carry out this purpose, I considered the various opinions of professors and librarians, after investigating and analyzing facilities and furnishings of laboratory rooms and teaching and learning data related to departments of library and information science in 32 universities. These contents can be summarized as follows : 1) Constructional media centers connected to education of library and information science sets laboratory rooms for practical classification and cataloging classes; laboratory rooms for film media which can utilize advanced media, listening tools, and practical materials; information management laboratory rooms which can experience the various information research methods through the Internet, cultivate the ability of information application, and teach the curriculum of library and information science related to computers. 2) Arrangement plans linked to laboratory rooms for classification and cataloging, one for film media, and one for information proceedings are as follows: , , and . 3) The size of each room is $162m^2$ (49.1pying); the number of persons to be admitted is about 40 to 50; each room has one media expert and one assistant as operating manager of exclusive responsibility. 4) Instructional & learning data which must be contained as instructional media of library and information science include computers, marginal tools related to it, listening materials, supplies for ordering books, teaching aids containing various equipment and tools, textbooks for practice, books connected to classification and cataloging for practice, and textbooks related to practical subjects and reference books. 5) Industrial media centers belonging to library and information science require for practice, general furnishings like bookshelves, and various material depository boxes.

  • PDF

Comparison on accuracy of porcelain color reproducibility using two colorimeters (2종의 측색기에 의한 도재 색조 재현의 정확성 비교)

  • Lee, Tai-Il;Ahn, Jin-Soo;Kim, Young-Soo;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.3
    • /
    • pp.348-355
    • /
    • 2009
  • Statement of problem: Although the use of colorimeter to improve the accuracy of tooth color measurement has increased, it is real situation that there is almost no comparative study about the accuracy among various colorimeters. Purpose: The purpose of this study is to compare the accuracy of porcelain color reproducibility using ShadeEye-Ncc dental chroma meter (Shofu Inc., Kyoto, Japan) and Shadepilot$^{TM}$ system (Degudent Inc., Hanau, Germany). Material and methods: Color of 2M2 and 3M2 shade tap of Vitapan 3D Master shade guide were measured using the above two colorimeters. Porcelain specimens were fabricated through this data. The porcelain systems used were Vintage Halo Porcelain system with ShadeEye-Ncc dental chroma meter, and VitaOmega900 Porcelain system with Shadepilot$^{TM}$ system. Colors of shade tap models and porcelain specimen were measured with spectrophotometer, and calculated delta E based on the results. Results: The following results were obtained. 1. Shadepilot$^{TM}$ system showed more suitable porcelain color reproducibility compared to ShadeEye-Ncc dental chroma meter (P <.05). 2. The result showed the difference of porcelain color reproducibility according to shade of Shade tap which is model. More suitable porcelain color reproducibility was shown at 3M2 shade tap than at 2M2 shade tap (P <.05). 3. The average of ${\Delta}E*$ of porcelain specimens which was made by the two colorimeters was 4.44-6.14, so the difference of shade was shown through the naked eye. Conclusion: Shadepilot$^{TM}$ system showed more suitable porcelain color reproducibility. When using ShadeEye-Ncc dental chromameter, it will be necessary to improve accuracy through coloring various parts of the whole tooth.

Evaluation of Cleaning ability and Environmental Evaluation of Commercial Aqueous/Semi-aqueous Cleaning Agents (시판 수계/준수계 세정제의 세정성 및 환경성 평가 연구)

  • Cha, A.J.;Park, J.N.;Kim, H.S.;Bae, J.H.
    • Clean Technology
    • /
    • v.10 no.2
    • /
    • pp.73-87
    • /
    • 2004
  • In most of industrial fields, cleaning is employed for removing soils on their products or parts. Halogenated cleaning agents such as CFC-113, 1,1,1-TCE(1,1,1-trichloroethane), MC(methylene chloride) and TCE (trichloroethylene) have been used as cleaning ones in most of companies in the world since their excellent performance of cleaning ability and good material compatibility. However, CFC-113 and 1,1,1-TCE which are ozone destruction substances are not used any more in the advanced countries because of the which are ozone destruction substances are not used any more in the advanced countries because of the Montreal protocol. MC and TCE are now used restrictively at small part of industrial fields in most of countries since they are known to be hazardous or carcinogenic materials. Thus, it is indispensible that the alternative cleaning agents which are environmental-friendly and safe, and show good cleaning ability should be developed or utilized for replacement of the halogenated cleaning agents. Aqueous/semi-aqueous cleaning agents are evaluated to be promising alternative ones among various alternatives in environmental and economical view point. In this study, commercially available 12 aqueous and 6 semi-aqueous cleaning agents were selected and their physical properties, cleaning abilities, rinsing abilities and recycling of contaminated rinse water were measured and analyzed. Aqueous cleaning agents with higher wetting index showed better cleaning ability compared with those with lower wetting index. However wetting index did not have any correlation with cleaning ability in semi-aqueous cleaning agents. It was observed that soil concentration in aqueous and semi-aqueous cleaning agents should be maintained below the certain concentrations which depend on types of clearing agents. More than 70% soils in contaminated rinse water by some of aqueous and semi-aqueous clearing agents could be separated by simple settling method. This means that some cleaning agents with high oil-water separation efficiency will be effiective for recycling oil-contaminated rinse water. It was found that contaminated rinse water with aqueous agents was purified easiy by ultrafiltration method with PAN membrane of 30 kDa.

  • PDF

The Role of Radiotherapy in the Treatment of Portal Vein Thrombosis from Advanced Hepatocellular Carcinoma (진행된 간세포암에서의 간문맥 혈전증에 대한 방사선치료 효과)

  • Kim, Jung-Hoon;Choi, Eun-Kyung;Ahn, Seung-Do;Lee, Sang-Wook;Shin, Seong-Soo;Choi, Won-Sik;Lim, Young-Suk;Kim, Kang-Mo;Suh, Dong-Jin;Chung, Young-Wha;Lee, Young-Sang;Won, Hyung-Jin;Kim, Jong-Hoon
    • Radiation Oncology Journal
    • /
    • v.25 no.3
    • /
    • pp.170-176
    • /
    • 2007
  • Purpose: To determine the role of radiotherapy for the treatment of portal vein thrombosis (PVT) from hepatocellular carcinoma (HCC). Material and Methods: A retrospective analysis was performed on 70 patients that had been diagnosed with HCC and were treated with three-dimensional conformal radiotherapy (3D-CRT) for the PVT. The radiation dose ranged from 40 Gy to 60 Gy (median dose: 48 Gy) and the biological effective dose (BED) ranged from 31.3 Gy to 78.0 $Gy_{10}$ (median dose: 61.6 $Gy_{10}$). Response was determined by measuring the extent of the PVT on a CT image at 0, 1 and 3 months after completion of the radiotherapy. The median follow-up period was 9 months. Results: The response rate was 47.1% (33 patients), with two patients (2.9%) showing a complete response, 31 patients (44.3%) showing a partial response, and 35 patients (50%) showing stable disease or no response. The 1-year progression-free survival rate was 60%, and the median progression-free survival time was 17 months. The median overall survival time was 11 months, the median survival time in the responders was 15 months and in the nonresponders was 8 months (p=0.032). Four patients (5.7%) had transient liver function impairment during treatment. Radiation induced liver disease (RILD) was observed in only one patient (1.4%). Conclusion: Three-dimensional conformal radiotherapy for the treatment of PVT from advanced HCC was a relatively effective and safe method.

The effect of Ca-P coatings of anodized implant surface on response of osteoblast-like cells in vitro (임플란트 표면의 Ca-P 코팅 방법이 MG63 골모유사세포 반응에 미치는 영향에 대한 in vitro 연구)

  • Kim, Il-Yeon;Jung, Sung-Min;Hwang, Soon-Jung;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.376-384
    • /
    • 2009
  • Purpose: The purpose of this study was to evaluate the response of osteoblast-like cells to Ca-P coated surface obtained via Ion beam-assisted deposition (IBAD) method and Sol-Gel process on anodized surface by cellular proliferation and differentiation. Material and methods: The surface of a commercially pure titanium (Grade IV) discs with dimension of 10mm diameter and 2 mm thickness was modified by anodic oxidation under a constant voltage of 300 V. The experimental groups were coated with Ca-P by the IBAD method and Sol-Gel process on anodized surface. The surface roughness (Ra) of specimens was measured by optical interferometer and each surface was examined by SEM. To evaluate cell response, MG63 cells were cultured and cell proliferation, ALP activity and the ability of cell differentiation were examined. Also, cell morphology was examined by SEM. The significant of each group was verified by Kruskal-Wallis Test ($\alpha$=.05). Results: The Ra value of Ca-P coated surface by IBAD method was significantly higher than Ca-P coated surface by Sol-gel process (P < .05). The level of cell proliferation and ALP activity was higher in Ca-P coated surface by IBAD method (P<.05). The expression of ALP showed higher level expression in Ca-P coated surface by IBAD method. Cells grown on Ca-P coated surface by IBAD method were uniformly distributed and developed a very close layer. Conclusion: These experiments showed better performances of Ca-P coated surface by IBAD method with respect to Ca-P coated surface by Sol-gel process. Ca-P coated surface by IBAD method appear to give rise more mature osteoblast characteristics and might result in increased bone growth and bone-implant contact.

Development of Cosmetic Ingredient by Fermented Paprika Juice (파프리카 발효즙의 화장품 소재개발 연구)

  • Bae, Soo Jung;Song, Min Hyeon;Oh, Jung Young;Bae, Jun Tae;Kim, Jin Hwa;Lee, Geun Soo
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.44 no.2
    • /
    • pp.117-124
    • /
    • 2018
  • In this study, cosmetic materials were developed using a new method of making juice through the fermentation of raw natural materials with microorganisms in order to supplement the advantages and disadvantages of an organic solvent extraction method and a microbial fermentation method. The natural products were selected from two colors (red, green) of paprika known to be rich in various colors and vitamins. The microorganisms used for fermentation were fermented by inoculating paprika with lactic acid bacteria (Lactobacillus plantarum) having sugar-hydrolyzed ability. First, we investigated the changes of physiologically active substances of two kinds of paprika juice and two kinds of fermented paprika juice. Total phenols content and total flavonoids content were higher in the fermented paprika juice than in the paprika juice, and especially in the fermented red paprika juice. Free radical scavenging effect and lipid peroxidation inhibitory effect were also showed an excellent antioxidative effect on paprika fermented juice, among which the effect of red paprika fermentation juice was the highest. The expression of MMP-1 in fermented red paprika juice with high antioxidant activity was inhibited by concentration-dependent expression of MMP-1 mRNA and MMP-1 protein. In the glycation experiments with aging, the anti-glycation effect of fermented paprika juice was highly inhibited by the production of advanced glycation end-products (AGEs), which was closely related to the antioxidant effect. In addition, the activity of senescence-associated ${\beta}$-galactosidase (SA-${\beta}$-gal), an indicator of cell senescence, was measured using human dermal fibroblast (HDF). The results showed that the cell senescence was inhibited when the cells were treated with fermented paprika juice. In conclusion, fermented paprika juice using lactic acid bacteria showed better antioxidative and anti-aging effects than paprika juice. Among them, fermented red paprika juice has the best antioxidant and anti-aging effect and can be applied as natural new material of antioxidant and anti-aging.

Adenosine Deaminase Activity in Bronchoalveolar Lavage Fluid in Patients with Pulmonary Tuberculosis (폐결핵 환자의 기관지폐포세척액에서 Adenosine Deaminase 활성도에 관한 연구)

  • Cheon, Seon-Hee;Cho, Chul-Ho;Kim, Byung-Il;Jang, Sang-Ho;Chang, Joon;Kim, Sung-Kyu;Hahn, Jee-Sook;Lee, Won-Young;Kwon, Oh-Hun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.38 no.1
    • /
    • pp.16-24
    • /
    • 1991
  • Adenosine deaminase (ADA) is an enzyme which is essential for the differentiation of lymphoid cells, especially T-cells and ADA plays a role in the maturation of monocyte to macrophage. Therefore ADA levels are related to stimulation of cellular immunity. We have investigated the measurement of ADA activity in bronchoalveolar lavage fluid of the patients with active and inactive pulmonary tuberculosis and control group. The results obtained are as follows: 1) The ADA activity and corrected ADA activity from the BAL fluid in active tuberculosis group (Total Lavage ADA; $18.4{\pm}22.5\;mU$, Total Lavage ADA/Albumin; $2.45{\pm}1.61\;mU/mg$) were increased when compared with those in inactive tuberculosis (TL-ADA; $5.8{\pm}2.5\;mU$, TL-ADA/Alb; $1.83{\pm}O.53\;mU/mg$) and control (TL-ADA; $6.6{\pm}4.3\;mU$, TL-ADA/Alb; $1.62{\pm}0.60\;mU/mg$) groups. 2) The ADA activity and lavage ADA/serum ADA activity ratio in BAL fluid from the lesion site (TL-ADA; $42.9{\pm}42.3\;mU$, L-ADA/S-ADA; $0.53{\pm}0.32$) were increased when compared with those from the non-lesion site (TL-ADA; $12.5{\pm}11.2\;mU$, L-ADA/S-ADA; $0.29{\pm}0.12$)and normal side (TL-ADA; $12.7{\pm}11.0\;mU$, L-ADA/S-ADA; $0.34{\pm}0.27$) in active tuberculosis group. 3) The ADA activity in BAL fluid from far advanced group (TL-ADA; $62.5{\pm}30.3\;mU$) was increased when compared with those from the mild group (TL-ADA; $10.5{\pm}7.5\;mU$) and moderate advanced group (TL-ADA; $13.2{\pm}11.7\;mU$) in active tuberculosis. 4) The albumin level from the BAL fluid was correlated with the ADA activity (R=0.89). 5) The ADA activity recovered from the BAL fluid was correlated with the recovered lymphocyte percentage (R=0.60). In conclusion, the ADA activity from the BAL fluid in active tuberculosis group was increased when compared with that in inactive tuberculosis and control groups, especially from the lesion site. To evaluated the specificity of ADA determination for diagnosis of active tuberculosis, BAL must be done at lesion site of the diseased lung and the proper correcting material other than albumin must be chosen to correct the dilution factor of lavage fluid.

  • PDF

Report for Development of Korean Portable Cardiopulmonary Bypass Machine (한국형 이동식 심폐소생기 개발 보고 I. 실험견을 이용한 개흉식과 폐쇄식 심폐소생술 비교)

  • Kim, Hyoung-Mook;Lee, In-Sung;Baek, Man-Jong;Sun, Kyung;Kim, Kwang-Taik;Kim, Yeon-Soo;Kim, Maeng-Ho;Lee, Hye-Won;Lee, Kyu-Back;Kim, Hark-Jei
    • Journal of Chest Surgery
    • /
    • v.31 no.9
    • /
    • pp.827-836
    • /
    • 1998
  • Background: Effective cardiopulmonary resuscitation (CPR) should provide acceptable hemodynamics for the vital organs during cardiac arrest and early restoration of spontaneous circulation that guarantees long-term, neurologically intact survival. CPR using heart-lung bypass has been suggested as an option for that use. This study was designed to determine the effectiveness of standard CPR techniques, closed-vs. open-chest CPR, which could be used in the future study verifying the role of heart-lung bypass CPR. Material and Method: By using adult mongrel dogs, closed-chest CPR (CCCPR, n=4) and open-chest CPR (OCCPR, n=5) were compared with respects to hemodynamics, restoration of spontaneous circulation(ROSC), and survival. Ventricular fibrillation-cardiac arrest (VF-CA) was induced by electrical shock in all animals. After 4 minutes of cardiac arrest, basic life support (BLS) was applied for 15 minutes and followed by advanced life support (ALS). ALS was maintained until achi ving ROSC but not longer than 30 minutes regardless of the recovery. Resuscitation procedures in either group were standardized by adopting the protocol of American Heart Association. Result: Prearrest baseline hemodynamic data was not different between two groups. During resuscitation, substantially higher systolic pressure was maintained in OCCPR group than in CCCPR group (45$\pm$15 vs. 33$\pm$11 mmHg during BLS, 83$\pm$36 vs. 44$\pm$15 mmHg during ALS; p=NS). Mean pulmonary arterial pressure went up to the level of mean systemic arterial pressures in CCCPR group and to half of that in OCCPR group, and had kept higher in CCCPR group throughout CPR (32$\pm$10 vs. 22$\pm$4 mmHg during BLS and 32$\pm$15 vs. 24$\pm$10 mmHg during ALS; p=NS). ROSC was obtained in 4 of 5 dogs receiving open-chest CPR and 2 of 4 closed-chest CPR. Prolonged survival was noted in all dogs in OCCPR group (6 to 1440 hours) but not in CCPR group (p<.05). Conclusion: These findings indicate that open-chest CPR can be more effective t maintain hemodynamics during cardiac arrest and to obtain restoration of spontaneous circulation and survival. Further experiment will be designed to compare heart-lung bypass CPR with open-chest CPR.

  • PDF

Esophagectomy for Esophageal Cancer in Elderly Patients Over 70 Years of Age (70세 이상의 식도암 환자에시 식도절제술 및 재건술)

  • Song Suk-Won;Lee Hyun-Sung;Kim Moon Soo;Lee Jong Mog;Zo Zae Ill
    • Journal of Chest Surgery
    • /
    • v.38 no.6 s.251
    • /
    • pp.428-433
    • /
    • 2005
  • Advanced age in Esophagectomy increases the risk of postoperative morbidity and mortality. However, the recent development of operative technique and perioperative care might have decreased the postoperative morbidity and mortality after esophagectomy. Material and Method: From March 2001 to July 2004, 174 patients underwent esophageal resection for esophageal cancer in the Center for Lung Cancer, National Cancer Center. The patients were divided into two groups : group 1 consisted of 27 patients aged 70 years or more, and group 2 consisted of 147 patients under 70 years of age. The two groups were compared according to preoperative risk factors, postoperative morbidity, operative mortality and survival. Result: The mean age was 63_4. There were 159 men. On histopathological examination, $93.1\%$ had squamous cell carcinoma. On the locations, $78.7\%$ were in mid and lower esophagus. Curative resections for esophageal cancer were possible in $162(93.1\%)$ patients. Mean hospital stay was 19.4 days with out difference between the groups. The overall postoperative morbidity were occurred in 61 patients $(35.1\%)$. The most frequent morbidity was pulmonary complication in $30(17.2\%)$. Preoperative incidence of hypertension, cardiac and pulmonary dysfunction were more common in Group I. However, there was no difference in overall postoperative morbidity, operative mortality and survival rate between the two groups. Conclusion: Esophagectomy for esophageal cancer could be carried out safely in patients over 70 years of age with satisfactory short-term results. Advanced age is no longer a risk factor for esophagectomy.