• 제목/요약/키워드: Advanced imaging

검색결과 821건 처리시간 0.027초

Height and Position Estimation of Moving Objects using a Single Camera

  • Lee, Seok-Han;Lee, Jae-Young;Kim, Bu-Gyeom;Choi, Jong-Soo
    • 한국방송∙미디어공학회:학술대회논문집
    • /
    • 한국방송공학회 2009년도 IWAIT
    • /
    • pp.158-163
    • /
    • 2009
  • In recent years, there has been increased interest in characterizing and extracting 3D information from 2D images for human tracking and identification. In this paper, we propose a single view-based framework for robust estimation of height and position. In the proposed method, 2D features of target object is back-projected into the 3D scene space where its coordinate system is given by a rectangular marker. Then the position and the height are estimated in the 3D space. In addition, geometric error caused by inaccurate projective mapping is corrected by using geometric constraints provided by the marker. The accuracy and the robustness of our technique are verified on the experimental results of several real video sequences from outdoor environments.

  • PDF

스마트TV를 이용한 공동주택의 에너지 사용 모니터링 시스템 (A Monitoring System of Energy Usage for Apartment Houses Using Smart TV)

  • 박성수;진영훈;남상훈;채영호
    • 한국CDE학회논문집
    • /
    • 제18권6호
    • /
    • pp.451-460
    • /
    • 2013
  • This paper presents the necessary elements and data flow in developing a monitoring system of energy usage for apartment houses with a Smart TV. Energy consumption data in each home are collected and analyzed in the HUB station by way of measuring instruments. And the amount of energy usage, such as electricity, gas, hot water, heating, water and other utilities are displayed through the Smart TV application. Energy consumption Database in the HUB station are processed and displayed in the browser of a Smart TV through XML, JAVASCRIPT and Flash. Smart TV users can get the energy consumption status through the energy consumption analysis display of the Smart TV application and improve the energy efficiency by comparing the usage patterns with neighboring houses. And the application display energy usage information, consumption ranking, rates to user as well. Furthermore, usage of last month or year can be compared to help to reduce the energy usage. The proposed system can provide the information about the amount of energy use to be reduced and the warning on the waste of energy.

Coherent X-ray Diffraction Imaging with Single-pulse Table-top Soft X-ray Laser

  • Kang, Hyon-Chol;Kim, H.T.;Lee, S.K.;Kim, C.M.;Choi, I.W.;Yu, T.J.;Sung, J.H.;Hafz, N.;Jeong, T.M.;Kang, S.W.;Jin, Y.Y.;Noh, Y.C.;Ko, D.K.;Kim, S.S.;Marathe, S.;Kim, S.N.;Kim, C.;Noh, D.Y.;Lee, J.
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2008년도 동계학술발표회 논문집
    • /
    • pp.429-430
    • /
    • 2008
  • We demonstrate coherent x-ray diffraction imaging using table-top x-ray laser at a wavelength of 13.9nm driven by 10-Hz ti:Sapphire laser system at the Advanced Photonics Research Institute in Korea. Since the flux of x-ray photons reaches as high as $10^9$ photons/pulse in a $20{\times}20{\mu}m^2$ field of view, we measured a ingle-pulse diffraction pattern of a micrometer-scale object with high dynamic range of diffraction intensities and successfully reconstructed to the image using phase retrieval algorithm with an oversampling ratio of 1:6. the imaging resolution is $^{\sim}150$ nm, while that is much improved by stacking the many diffraction patterns. This demonstration can be extended to the biological sample with the diffraction limited resolution.

  • PDF

Using Field Programmable Gate Array Hardware for the Performance Improvement of Ultrasonic Wave Propagation Imaging System

  • Shan, Jaffry Syed;Abbas, Syed Haider;Kang, Donghoon;Lee, Jungryul
    • 비파괴검사학회지
    • /
    • 제35권6호
    • /
    • pp.389-397
    • /
    • 2015
  • Recently, wave propagation imaging based on laser scanning-generated elastic waves has been intensively used for nondestructive inspection. However, the proficiency of the conventional software based system reduces when the scan area is large since the processing time increases significantly due to unavoidable processor multitasking, where computing resources are shared with multiple processes. Hence, the field programmable gate array (FPGA) was introduced for a wave propagation imaging method in order to obtain extreme processing time reduction. An FPGA board was used for the design, implementing post-processing ultrasonic wave propagation imaging (UWPI). The results were compared with the conventional system and considerable improvement was observed, with at least 78% (scanning of $100{\times}100mm^2$ with 0.5 mm interval) to 87.5% (scanning of $200{\times}200mm^2$ with 0.5 mm interval) less processing time, strengthening the claim for the research. This new concept to implement FPGA technology into the UPI system will act as a break-through technology for full-scale automatic inspection.

An Antenna Tracking Profile Design for Communication with a Ground station

  • Lee, Donghun;Lee, Kyung-Min;Rashed, Mohammed Irfan;Bang, Hyochoong
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제14권3호
    • /
    • pp.282-295
    • /
    • 2013
  • In order to communicate with a ground station, the tracking profile design problem for a directional antenna system is considered. Because the motions of the gimbal angles in the antenna system affect the image quality, the main object is to minimize the motion of the gimbal angles during the satellite's imaging phase. For this goal, parameter optimization problems in the imaging and maneuver phases are formulated separately in the body-frame, and solved sequentially. Also, several mechanical constraints, such as the limitation of the gimbal angle and rate, are considered in the problems. The tracking profiles of the gimbal angles in the maneuver phases are designed with N-th order polynomials, to continuously connect the tracking profiles between two imaging phases. The results confirm that if the vector trace of the desired antenna-pointing vector is within the antenna's beam-width angle, motions of the gimbal angles are not required in the corresponding imaging phase. Also, through numerical examples, it is shown that motion of the gimbal angles in the imaging phase can be minimized by the proposed design process.

식품의 품질 및 안전 관리를 위한 테라헤르츠 분광/영상 기술의 응용 (Application of terahertz spectroscopy/imaging technology for food quality and safety management)

  • 이상유;우소영;전향숙
    • 식품과학과 산업
    • /
    • 제51권1호
    • /
    • pp.26-36
    • /
    • 2018
  • Terahertz (THz) represents the portion of the electromagnetic radiation between the microwave and the infrared region and is within the frequency range of 0.1-10 THz. The ability of THz waves to pass through a wide variety of packaging materials, combined with their ability to characterize the molecular structure of many substances makes it an attractive tool for the application of food quality and safety management. This review provides current information on application of THz spectroscopy/imaging technology for food quality and safety management. The THz spectroscopy/imaging technology has been shown to be useful for detecting foreign bodies, vitamin/moisture, pesticides, antibiotics, melamine etc. However, major barriers to the adoption of THz spectroscopy/imaging for food quality and safety management include THz signal loss in heterogeneous food matrices, high costs of sources and detectors, and absence of a library for the wide group of food compounds. Further research is needed to overcome these barriers.

Advanced neuroimaging techniques for evaluating pediatric epilepsy

  • Lee, Yun Jeong
    • Clinical and Experimental Pediatrics
    • /
    • 제63권3호
    • /
    • pp.88-95
    • /
    • 2020
  • Accurate localization of the seizure onset zone is important for better seizure outcomes and preventing deficits following epilepsy surgery. Recent advances in neuroimaging techniques have increased our understanding of the underlying etiology and improved our ability to noninvasively identify the seizure onset zone. Using epilepsy-specific magnetic resonance imaging (MRI) protocols, structural MRI allows better detection of the seizure onset zone, particularly when it is interpreted by experienced neuroradiologists. Ultra-high-field imaging and postprocessing analysis with automated machine learning algorithms can detect subtle structural abnormalities in MRI-negative patients. Tractography derived from diffusion tensor imaging can delineate white matter connections associated with epilepsy or eloquent function, thus, preventing deficits after epilepsy surgery. Arterial spin-labeling perfusion MRI, simultaneous electroencephalography (EEG)-functional MRI (fMRI), and magnetoencephalography (MEG) are noinvasive imaging modalities that can be used to localize the epileptogenic foci and assist in planning epilepsy surgery with positron emission tomography, ictal single-photon emission computed tomography, and intracranial EEG monitoring. MEG and fMRI can localize and lateralize the area of the cortex that is essential for language, motor, and memory function and identify its relationship with planned surgical resection sites to reduce the risk of neurological impairments. These advanced structural and functional imaging modalities can be combined with postprocessing methods to better understand the epileptic network and obtain valuable clinical information for predicting long-term outcomes in pediatric epilepsy.

Robust Watermarking for Compressed Video Using Fingerprints and Its Applications

  • Jung, Soo-Yeun;Lee, Dong-Eun;Lee, Seong-Won;Paik, Joon-Ki
    • International Journal of Control, Automation, and Systems
    • /
    • 제6권6호
    • /
    • pp.794-799
    • /
    • 2008
  • This paper presents a user identification method at H.264 streaming using watermarking with fingerprints. The watermark can efficiently reduce the potential danger of forgery or alteration. Especially a biometric watermark has convenient, economical advantages. The fingerprint watermark can also improve reliability of verification using automated fingerprint identification systems. These algorithms, however, are not robust against common video compression. To overcome this problem, we analyze H.264 compression pattern and extract watermark after restoring damaged watermark using various filters. The proposed algorithm consists of enhancement of a fingerprint image, watermark insertion using discrete wavelet transform and extraction after restoring. The proposed algorithm can achieve robust watermark extraction against H.264 compressed videos.

복부 핵자기공명 영상에서 영상번짐의 교정을 위한 최적 호흡 정렬법 (Optimal Respiratory Ordering Scheme (OROS) for Correcting Blurring Artifacts in Abdominal Magnetic Resonance Imaging)

  • 정관진;안우연;조장희
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1990년도 추계학술대회
    • /
    • pp.15-18
    • /
    • 1990
  • In abdominal NMR imaging the respiratory ordering techniques have been successfully used to remove the ghosting artifacts arising from the respiratory motion. In the existing respiratory ordering schemes, however, it is generally accepted that blurring of the moving parts still remains as in the signal averaging technique. A new optimal respiratory ordering scheme which can correct the blurring as well as the ghosting artifacts is theoretically derived through the analysis of the phase encoding directional motion effects in Fourier imaging. The performance of the optimal respiratory ordering scheme is experimentally confirmed together with a suboptimal ordering scheme which is suggested as a compromise for the practicality.

  • PDF

상관도 비교를 이용한 웨이블릿 기반 워터마킹 (Wavelet-based Watermarking using Correlation Comparison)

  • Lee, Hyun-Suk;Vivi Oktavia;Lee, Won-Hyung
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 신호처리소사이어티 추계학술대회 논문집
    • /
    • pp.217-220
    • /
    • 2003
  • This paper presents a wavelet-based digital watermarking scheme for color images. We insert watermarks in the DWI domain using spread-spectrum correlation-based watermarking in luminance component of the color image. The watermark, two pseudorandom patterns, is inserted by modifying the wavelet coefficients at subband HL2, LH2, HH2 according to message bits. To detect watermark, we calculate the correlation between the watermarked image and pseudorandom patterns. As compared with correlations, the watermark detector determines embedding message. Experimental results show that the scheme is not only invisible but also robust to various attacks such as JPEG compression, noise addition and so on.

  • PDF