• 제목/요약/키워드: Advanced Water treatment processes

검색결과 137건 처리시간 0.022초

낙동강 수계 페놀처리를 위한 정수처리시스템 평가 (Evaluation of Water Treament System for Phenol Removal in the Nakdong River Basin)

  • 강병재;채선하;이경혁;전항배
    • 상하수도학회지
    • /
    • 제23권5호
    • /
    • pp.609-618
    • /
    • 2009
  • Repeated phenol spill in the Nakdong River has been a big issue in Korea since 1991. In this study, treatment of phenol in each water treatment process and total water treatment system is evaluated. Phenol was highly volatile, easily oxidized by ozone, and readily absorbed onto GAC. When there was phenol of 0.3mg/L in water, by ozonation of 1mg/L or by GAC adsorption with EBCT of 10minutes or longer, it could be treated to lower than 0.005mg/L, the national drinking water standard of phenol. Even when a sufficient contact time(70minutes) was allowed, only 35 to 40% of phenol could be removed by powdered activated carbon(PAC). Based on the test results, it can be concluded that 1.0mg/L or less concentration of phenol can be treated at the plants adopting the combination process of ozone and GAC down to the safe level. In this study, removal characteristics for phenol were evaluated with the existing pilot plant and demo plant in different advanced water treatment processes(AWTPs). In the future, studies on changes in oxidation and adsorption characteristics caused by competitive matters such as DOC and removal characteristics by other various AWTPs including ozone/filter adsorber need to be performed.

Recent Advances in Advanced Oxidation Processes

  • Huang, Chin-Pao
    • 한국환경과학회:학술대회논문집
    • /
    • 한국환경과학회 1998년도 가을 학술발표회 프로그램
    • /
    • pp.1-1
    • /
    • 1998
  • Advanced (Chemical) oxidation processes (AOP) differ from most conventional ones in that hydroxyl radical(OH.) is considered to be the primary oxidant. Hydroxyl radicalcan react non-selectively with a great number of organic and inorganic chemicals. The typical rate constants of true hydroxyl radical reactions are in the range of between 109 to 1012 sec-1. Many processes are possible to generate hydroxyl radical. These include physical and chemical methods and their combinations. Physical means involves the use of high energy radiation such as gamma ray, electron beam, and acoustic wave. Under an applied high energy radiation, water molecules can be decomposed to yield hydroxyl radicals or aqueous electrons. Chemical means include the use of conventional oxidants such as hydrogen peroxide and ozone, two of the most efficient oxidants in the presence of promoter or catalyst. Hydrogen peroxide in the presence of a catalyst such as divalent iron ions can readily produce hydroxyl radicals. Ozone in the presence of specific chemical species such as OH- or hydrogen peroxide, can also generate hydroxyl radicals. Finally the combination of chemical and physical means can also yield hydroxyl radicals. Hydrogen peroxide in the presence of acoustic wave or ultra violet beam can generate hydroxyl radicals. The principles for hydroxyl radical generation will be discussed. Recent case studied of AOP for water treatment and other environmental of applications will be presented. These include the treatment of contaminated soils using electro-Fenton, lechate treatment with conventional Ponton, treatment of coal for sulfur removal using sonochemical and the treatment of groundwater with enhanced sonochemical processes.

  • PDF

난분해성 산업폐수 처리를 위한 고도산화기술 (Advanced oxidation technologies for the treatment of nonbiodegradable industrial wastewater)

  • 김민식;이기명;이창하
    • 상하수도학회지
    • /
    • 제34권6호
    • /
    • pp.445-462
    • /
    • 2020
  • Industrial wastewater often contains a number of recalcitrant organic contaminants. These contaminants are hardly degradable by biological wastewater treatment processes, which requires a more powerful treatment method based on chemical oxidation. Advanced oxidation technology (AOT) has been extensively studied for the treatment of nonbiodegradable organics in water and wastewater. Among different AOTs developed up to date, ozonation and the Fenton process are the representative technologies that widely used in the field. Based on the traditional ozonation and the Fenton process, several modified processes have been also developed to accelerate the production of reactive radicals. This article reviews the chemistry of ozonation and the Fenton process as well as the cases of application of these two AOTs to industrial wastewater treatment. In addition, research needs to improve the cost efficiency of ozonation and the Fenton process were discussed.

UF/MF막을 이용한 고도수처리 (Advanced Water Treatment by UF/MF Membranes)

  • 김기협
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1997년도 제5회 하계 Workshop (97 한,카 국제공동 Workshop, 고도 수처리를 위한 막분리 공정)
    • /
    • pp.105-142
    • /
    • 1997
  • We know very well the importance of water. Recently, we perceive the truth that water influence the quality of products and we must pay for it. Besides, we recognize why the water treatment is indispensable for life as well as industries. The variation of environment changes the natural resources and threatens the human life. Now, we cannot get water freely from nature. We should find new processes which are effective and inexpensive. We believe that the membrane technology can suggest the new way of water treatment. I'd like to explain the situation of water resource and the membrane processes by UF/MF membranes. I'll also introduce several case studies in this lecture. Till now, about 10 MF/UF systems were established in Korea. Of course, the usage of MF/UF for water treatment is beginning stage in Korea. But the future prospect is very good. Korean government has been developed various kinds of membrane processes for the purpose of drinking water, water reuse, development of new water resources and water related technologies, etc. In near future, maybe we will meet serious water problems, water deficiency and contamination. Fortunetely, we can suggest the membrane process for solving those problems. Membrane technology will be the base of clean technology.

  • PDF

고도정수처리 공정에서 브로메이트의 거동 평가 (Formation behaviour of Bromate in Processes of Advanced Water Treatment System using Nakdong river water)

  • 김영진;현길수
    • 상하수도학회지
    • /
    • 제25권4호
    • /
    • pp.605-610
    • /
    • 2011
  • The objectives of this study are to investigate a bromate behaviour in the processes of advanced water treatment system (AWTS: preozonation, coagulator-settler, rapid sand filter, postozonation, biological activated carbon (BAC) beds) and to investigate the effects of ozonation, pH and ammonia nitrogen on bromate (${BrO^-}_3$) formation. As a result, $BrO_3$ was not detected in the processes of the AWTS without ozonation, while it was detected in a preozonated and postozonated water. For $BrO_3$ formation during June to November, the $BrO_3$ concentration of <9.4${\mu}g/L$ was observed in postozonated water, while it was reduced to about 46% by BAC beds. When applied ozone dosage and ozone contact time for influent with $Br^-$ of <0.3mg/L were 0.5-2.0mg/L.min and 10 min., $BrO_3$ concentration increased with increasing ozone dosage. Longer contact time and lower ozone level also was needed to inhibit the formation of $BrO_3$. At ozone dosage of 1.4 mg/L.min, the formation rate of $BrO_3$ increased with increase of pH value. When $NH_4-N$ concentration increased from 0.1mg/L to 0.4mg/L, $BrO_3$ concentration decreased to about 38%. These results revealed that $BrO_3$ concentration increased with increasing Br level, ozone dosage, and pH value, while it decreased with increase of $NH_4-N$ concentration.

Recent Progress in Surface Science and Its Application in Advanced Water Treatment by Membrane Processes

  • Matsuura, Takeshi
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1997년도 제5회 하계 Workshop (97 한,카 국제공동 Workshop, 고도 수처리를 위한 막분리 공정)
    • /
    • pp.21-35
    • /
    • 1997
  • As environmental regulations become more stringent, water, used either as drinking water or as industrial process water, becomes increasingly better in its quality. As a result, an increasingly more advanced water treatment technology is required. It is believed that membrane technology will be able to satisfy such a requirement. The heart of the membrane technology is membrane. The advancement in water treatment technology using membranes, therefore, depends on the development of novel membranes which are superior in performance to the currently available membranes. In this paper, a brief review will be made how the recent progress in surface science, such as surface modification and surface characterization, has aided to improve the performance of the membranes used for water treatment. Some suggestions will also be made regarding the future direction of the research in this area.

  • PDF

용수 및 폐수 처리를 위한 오존 마이크로버블 적용 (Application of Ozone Microbubbles in the Field of Water and Wastewater Treatment)

  • 남귀웅;정진호
    • Ecology and Resilient Infrastructure
    • /
    • 제3권4호
    • /
    • pp.256-262
    • /
    • 2016
  • 급격한 산업화와 인구증가로 인한 화학물질 사용량의 증가는 기존의 수 처리 방식의 대부분을 차지하는 생물학적 공정의 한계를 불러온다. 이와 같은 문제를 해결하기 위한 방법으로 고급산화공정의 하나인 오존 마이크로버블 기술이 최근 주목을 받고 있다. 본 논문에서는 마이크로버블의 물리학적 및 화학적 특성에 대해 논하고, 다양한 독성 오염물질의 제거를 중심으로 마이크로버블 오존산화공정을 분석하였다. 또한 다른 처리 기술과 결합한 오존 마이크로버블 기술의 용수 및 폐수처리 전망을 논하였다.

한강수계 고도정수처리 공정에서의 유기물과 맛·냄새의 제거특성 (Removal Characteristics of Natural Organic Matter and Taste and Odor by Advanced Water Treatment Process around the Han River Water Supply System)

  • 임재림;이경혁;김성수;채선하
    • 상하수도학회지
    • /
    • 제21권1호
    • /
    • pp.13-25
    • /
    • 2007
  • The water treatment plants in Seoul Metropolitan Area, which are under Korea Water Resources Corporation(KOWACO)'s management, take water from Paldang Reservoir in Han River System for drinking water supply. There are taste and odor (T&O) problems in the finished water because the conventional treatment processes do not effectively remove the T&O compounds. As part of countermeasures for taste and odor control, KOWACO is planning to introduce advanced water treatment process such as ozone and GAC in near future. This study evaluated the removal characteristics of T&O and dissolved organic matter (DOM) to find design and operation parameters of advanced water treatment processes in a pilot-scale treatment plant. The GAC adsorption capacity for DOC in the two GAC system (GAC and $O_3$-GAC) at an EBCT of 14min was mostly exhausted after 9months. The differency of the removal efficiency of DOC between $O_3$-GAC and GAC increased with increasing operation time because the bioactivity in $O_3$-GAC process was enhanced by post-ozone process. Removal by conventional treatment was unable to reach the target TON(threshold odor number) of 3 but GAC systems at an EBCT(empty bed contact time) of 14 min were able to archive the target with few exception. During the high T&O episodes, PAC as a pretreatment together with GAC could be useful option for T&O control. However, substantial TON removal continued for more than two year (> 90,000 bed volumes). At the spiking of less concentration 26 to 61 ng/L in the influent of GAC systems, GAC absorber and $O_3$-GAC processes could meet the treatment target. The better spike control after 12 and 19 months of operation compared to that after 7 months of operation is a strong indication of biological control. The results presented in this study had shown that $O_3$-GAC process was found to be more effective for T&O control than GAC process. And the main removal mechanism in GAC systems were adsorption capacity and biodegradation.

고급산화공정을 이용한 염료폐수의 처리기술 연구 (A Study on the Dye Wastewater Treatment by Advanced Oxidation Process)

  • 강태희;오병수;박세준;강민구;김종성;강준원
    • 한국물환경학회지
    • /
    • 제21권3호
    • /
    • pp.267-273
    • /
    • 2005
  • Dye wastewater generally contains strong color and non-biodegradable materials. Therefore, the conventional wastewater treatment plant can hardly meet the regulation of wastewater effluent water. In this study, a pilot plant of the conventional process followed by advanced oxidation process (AOP), was set up to treat the dying wastewater. The treatment efficiencies on the various candidate processes, such as ozone alone, UV alone, ozone/UV, $ozone/H_2O_2$, $H_2O_2/UV$ and $ozone/UV/H_2O_2$, were investigated in the various ozone and $H_2O_2$ doses. As the results, the $ozone/H_2O_2$ process, among the tested processes, showed the highest efficiency for removing color and $COD_{Cr}$. For color removal, the ozone alone process was enough without combining UV or $H_2O_2$. No significantly enhanced efficiency for removing color and $COD_{Cr}$ by UV irradiation was observed because of the very low transmittance of UV light in dye wastewater.

수돗물 신뢰도 향상을 위한 품질 인증 제도 도입 (Introduction of Water Quality Certification System for Confidence Improvement of Tap Water)

  • 김진근
    • 상하수도학회지
    • /
    • 제29권2호
    • /
    • pp.155-163
    • /
    • 2015
  • Many advanced treatment processes have been introduced to WTPs, however, the consumer confidence on tap water is still low and the percentage of drinking water directly from the tap is less than 2 %. One of the methods to improve the credibility of tap water is to introduce a drinking water certification system. By introducing the system, water treatment processes can be optimized, which in turn, can significantly improve drinking water quality. In this paper, 6 water quality parameters(i.e., turbidity, CT, residual chlorine, geosmin, 2-MIB, Mn) which have significant influences on tap water quality and consumer confidence were identified, and their recommended guidelines were proposed. 3-Star or 5-Star certification can be awarded to the WTPs which have met the certification criteria. The drinking water certification system can be carried out as a voluntary program among drinking water suppliers.