• Title/Summary/Keyword: Adjustable

Search Result 842, Processing Time 0.032 seconds

A study on the difference of movement between Semi adjustable articulator and Oral in vivo (반조절성교합기와 구강에서의 운동 오차에 대한 비교 연구)

  • Moon, Hee-Kyung
    • Journal of Technologic Dentistry
    • /
    • v.28 no.1
    • /
    • pp.53-59
    • /
    • 2006
  • The movement range on the semi adjustable articulator and the movement range in an oral were measured. And then I studied to analyze the gap. I got wax records by the movement on the semi adjustable articulator, the movement in an oral. I measured the distance of the cusp tips that are close to the mesial direction and the distal direction, the buccal direction and the lingual direction then I compared gaps. As I saw results on data, I knew that the semi adjustable articulator represented the range of mandibular movement restrictively. I could find the decisive contradiction that the sliding movement finished on the semi adjustable articulator although it did not finish in an oral. When the sliding movement does not reappear exactly, it brings a fatal failure to the dental prosthesis. In addition it is impossible that the semi adjustable articulator restores the movement in an oral because the lateral condyle inclination and the horizontal condyle inclination are appeared to be straight. Therefore dental prosthesisses were made by the semi adjustable articulator, they will interfere with a mastication. I have obtained the following results; 1. The distance of sliding movement on the semi adjustable articulator showed shorter than the distance of sliding movement in oral. This means the increase of cusp inclination of the dental prosthesis that was made on the semi adjustable articulator. Therefore, when the lateral movement occurs in oral, there is a possibility to become the premature as the increase of cusp inclination. 2. The difference in the range of movement is considered as the gap that is made because the movement only can be occurred as straight in the semi adjustable articulator. 3. When the dental technician understand mandibular movement and articulator deficiencies, they can attain proficiency in use of the articulator and reduce the gap.

  • PDF

Effect of Adjustable Speed Pumped Storage Power Generator on the Frequency Control Against the Intermittence of Wind Turbine Output (풍력발전기 출력변동성에 대비한 가변속 양수발전기의 주파수 제어효과)

  • Park, Min-Su;Chun, Yeong-Han
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.3
    • /
    • pp.338-342
    • /
    • 2014
  • Energy storage is a key issue when integrating large amounts of intermittent and non-dispatchable renewable energy sources into electric power systems. To maintain the instantaneous power balance and to compensate for the influence of power fluctuations from renewable sources, flexible capability for power control is needed. Adjustable Speed Pumped Storage Power Generator is pumped storage unit that is adjustable for pump output adjustments as well as the highest efficiency operations because it has fast response time. In this paper we address the adjustable speed pumped storage power generator for frequency control against the intermittence of wind turbine output and calculate the appropriate capacity of adjustable speed pumped storage power generator.

Ergonomic Design and Evaluation of Adjustable Desk and Chair for Students (조절 가능한 학생용 책상과 의자의 인간공학적 설계 및 평가)

  • Jeong, Hwa-Sik
    • Journal of the Ergonomics Society of Korea
    • /
    • v.20 no.1
    • /
    • pp.15-29
    • /
    • 2001
  • This study was conducted to develop a prototype of adjustable desk and chair for students from elementary to high school. The development process started with identifying the problems of existing adjustable desks and chairs that are currently available in the market. The following fundamental design criteria were established and then applied to develop the prototype. The criterion of minimization of production cost yielding lower the market selling price was the most critically considered in view of the school furniture buyers' price-consciousness. Other design criteria used in this development were designing for stable and solid structure, requiring few motions and no tools to adjust, requiring the use of only one hand to adjust, unrestricting the adjustable interval, providing extra space for foot and knee area, reducing weight to move easily, and requiring not to move around for cleaning up floor. To evaluate the performance of the prototype, the adjustability of prototype was specifically compared with both dimensions suggested by KS G 2010(Korean Standards for desks and chairs for students) and current anthropometric dimension in terms of the flexible range of accommodation. Results of this study illustrate that the prototype developed in this study could be accommodated for the both dimensions. As a concluding mark, appropriate adjustable range for various grades and age groups were presented.

  • PDF

Optimization of Wheat Harvest

  • Kim, S.H.;Kolaric, W.J.
    • Agricultural and Biosystems Engineering
    • /
    • v.1 no.1
    • /
    • pp.7-15
    • /
    • 2000
  • Optimization was considered from three perspectives : minimum grain loss, minimum damaged grain loss, and minimum power consumption. Factors affecting combine performance were classified as control, adjustable, and environmental. Control and adjustable factors were optimized by the parameter design developed by Taguchi. Environmental factors were used as input for optimization. Optimum range for control and adjustable factors are presented. Parameter design was adequate to obtain the optimum levels of control factors and optimum range of adjustable factors.

  • PDF

OPTIMIZATION OF WHEAT HARVEST

  • Kim, Sang-hun-;William-J.Kolaric;Kang, Whoa-Seug
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.714-726
    • /
    • 1993
  • Optimization was considered from three perspectives ; minimum grain loss, minimum damaged grain loss, and minimum power consumption. Factors affecting combine performance were classified as control , adjustable , and environmental. Control and adjustable factors were optimized by the parameter design developed by Tajuchi. Environmental factors were used as input for optimization Optimum range for control and adjustable factors are presented. Parameter design was adequate to obtain the optimum levels of control factors and optimum range of adjustable factors.

  • PDF

A Comparison of Usability between the Height Adjustable Keyboard and the Adaptive Touch Keyboard on Smartphones

  • Choi, Jinhae
    • Journal of the Ergonomics Society of Korea
    • /
    • v.36 no.2
    • /
    • pp.145-156
    • /
    • 2017
  • Objective: This study aims to compare the usability of the adaptive touch design method with that of the height adjustable design method that are applied to the Korean QWERTY keyboard and Naratgul keyboard on smartphones, examine the results, and present practical implications. Background: Smartphone manufacturers have failed to satisfy every user with their uniform touch keyboard designs that do not consider the high use rates of keypad use. In reality, touch keyboard designing customized for every individual is impossible, but there need to be researches on was to improve usability by having touch areas changed automatically depending on user behaviors or having users adjust the keyboard height depending on their hand size. Method: As for the design methods, an object group was given smartphones with the adaptive touch design method and the other group those with the height adjustable design method. As they entered the same characters in the smartphones, typing error rates and text input speed were measured and the average values were compared. 35 individuals who would frequently use smartphones in daily life participated in the experiment. The group variable was the type of touch keyboards, and the test variables were typing error rates and text input speed, for which a T-test was implemented. Results: As for the QWERTY keyboard, the significant improvement effect was verified as the typing error rate of the adaptive touch design method was 4.21% but that of the height adjustable design method was 3.28% although there was no significant difference in terms of text input speed. As for the Naratgul keyboard, in contrast, the typing error rate of the adaptive touch design method was 2.5% while that of the height adjustable design method was 1.48%, which indicates a measure of improvement, but the effect was not significant. On the other hand, the text input speed per minute was improved as much as 22.2%, which is significant. Conclusion: First, the Korean touch keyboard usability of the adaptive touch design method and that of the height adjustable design method, when applied to Model A of Company L, showed significant difference from each other. Second, the height adjustable design method was applied to the QWERTY keyboard, the typing error rate was improved significantly. This indicates that as the keyboard height was raised, the number of buttons within the range of fingering decreased, decreasing the touch bias was reduced. Third, the height adjustable design method was applied to the Naratgul keyboard, the text input speed was improved. Application: When the QWERTY keyboard was applied to a smartphone as small as 5.5inch or less, it is highly probably that the height adjustable design method decreases the typing error rate. It may be considered to develop additional UX functions to make the keyboard font larger or give users the option to adjust button intervals in utilization of the SW advantages of the height adjustable design method.

Durability Evaluation of the Gage - Adjustable Wheelset System According to UIC Standard (UIC 기준에 따른 궤간 가변 윤축의 내구성 평가)

  • Kim, Chul-Su;Ahn, Seung-Ho;Chung, Kwang-Woo;Jang, Seung-Ho;Jang, Kook-Jin;Kim, Jung-Kyu
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.2156-2162
    • /
    • 2008
  • To reduce the cost and the time of transport in Eurasian railroad networks such as TKR, TCR and TSR owing to the problem of different track gauges (narrow/standard/broad gauge), it is important to develop the gauge - adjustable wheelset system to adapt easily to these gauges. The gauge - adjustable wheelset system in the transcontinental railway have been proposed as a more effective way in comparison with other techniques for overcoming difference in track gauges. Assume that the freight train with gauge adjustable wheelset system is running from domestic train network to TCR, TSR in Eurasian continent, it is necessary to estimate the safety of this system. This study is evaluated at examination of safety for freight train with gauge adjustable wheelset system by simulated durability analysis. Moreover, the predicted fatigue life at running track using the durability simulator was verified by the durability test according to UIC standard.

  • PDF

Development of Dental Scanning System and Reproduction of Adjustable Upper Dental Impression Tray (치과용 스캐닝 시스템의 개발과 가변형 상악용 트레이의 재현성)

  • Cha, Young-Youp;Eom, Sang-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.3
    • /
    • pp.300-304
    • /
    • 2010
  • This study was performed to development a dental three-dimensional laser scanning system and measure the accuracy of new adjustable upper dental impression tray. The metal stock, individual, and new adjustable stock trays were used for 30 stone casts(10 casts each) duplicated a resin master model of maxilla. The dental stone was poured in a vinyl polysiloxane impressions and allowed to set for on hour. The master model and the duplicated casts were digitized using an dental scanning system. The distance between the reference points were measured and analyzed on the graphic image of 3D graphic software of CATIA. The statistical significance of the differences between the groups was determined by a two-way ANOVA. There were no significant differences between the accuracies of the adjustable stock tray and the master model except only anterior arch width on the upper arch. The adjustable upper stock tray showed clinically acceptable accuracies of the study cast produced by them.

Accuracy of Stone Cast Produced by Adjustable Dental Impression Tray (가변형 치과 인상용 트레이로 제작된 모형의 재현성)

  • Park, Kwang-Su;Dong, Jin-Keun;Sim, Hun-Bo;Oh, Sang-Chun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.22 no.4
    • /
    • pp.317-328
    • /
    • 2006
  • Purpose: This study was performed to measure the accuracy of adjustable dental impression trays by a scanning laser three-dimensional digitizer. Materials and Methods: Metal stock tray and adjustable stock trays were used for 40 stone casts(10 casts each) duplicated a resin master model of mandible and maxilla. The type IV dental stone was poured in a allginate impressions and allowed to set for one hour. The casts were digitized using an optical digitizer. The distance between the reference points were measured and analyzed on the graphic image of 3-D graphic software (CATIA version 5.0). The statistical significance of the differences between the groups was determined by a two-way ANOVA. Results: There were no significant differences between the accuracies of the adjustable stock tray and the master model except anterior arch width of the upper arch and the diagonal arch length and arch length(one side) of the lower arch. Conclusion: The adjustable stock trays showed clinically acceptable accuracies of the study casts produced by them.