• Title/Summary/Keyword: Adhesive type patch

Search Result 14, Processing Time 0.024 seconds

Formulation and Pharmaceutical Properties of Transdermal Patch of Flurbiprofen (플루비프로펜 함유 경피 패취제의 제제설계 및 약제학적 성질)

  • 이계주;고유현;우종수;황성주
    • YAKHAK HOEJI
    • /
    • v.43 no.4
    • /
    • pp.447-457
    • /
    • 1999
  • The purpose of this study is to prepare the adhesive type patch containing flurbiprofen, and to demonstrate the feasibility of flurbiprofen administration through the intact skin using adhesive type patch preparation. For this purpose, two pressure sensitive adhesives, Polyisobutylene(PIB) and $Gelva^{\circledR}737$, were selected from the chemical grade of polymers, and the adhesive type patches of flurbiprofen were prepared. The release rate of flurbiprofen from the PIB-based adhesive patch was higher than that from $Gelva^{\circledR}737$ based adhesive patch. The release rate of flurbiprofen from the PIB-based A-type patch with 1.0mm, 1.5mm or 2.0mm thicknesses followed the first order kinetics. In the skin permeation study, using male hairless mouse skin, a monophasic skin permeation profile was observed with 1% flurbiprofen loading dose. The inclusion of palmitic acid or SLS(0.25~0.5%) as an enhancer produced a remarkable enhancement in the skin permeation rate of flurbiprofen, and the percentile ratio of drug and enhancer appeared to be important for the effective enhancement. In the in vivo percutaneous absorption study, the plasma concentration of the optimal formulation was significantly (p<0.01) higher than that of the conventional cataplasma ($Bifen^{\circledR}$). These studies demonstrate a good feasibility of flurbiprofen administration through the intact skin using a transdermal patch, and show a possibility of the development of flurbiprofen patches.

  • PDF

Formulation and Evaluation of Controlled Release Patch Containing Naproxen (나프록센 함유 방출제어형 패취의 제제설계 및 평가)

  • Rhee, Gye-Ju;Hong, Seok-Cheon;Hwang, Sung-Joo
    • Journal of Pharmaceutical Investigation
    • /
    • v.29 no.4
    • /
    • pp.343-348
    • /
    • 1999
  • The purpose of this study is to prepare the controlled release adhesive patch containing naproxen. Pressuresensitive adhesive (PSA)-type patch was fabricated by casting of polyisobutylene (PIE.) and mineral oil in toluene. Membrane-controlled release (MCR)-type patch was prepared by the attachment of the controlled release membrane on the PSAtype patch. The membrane was mainly composed of Eudragit, polyethylene glycol(PEG) and glycerin. The drug release profile and skin permeation test with various patches were evaluated in vitro. The release of naproxen from PIE-based PSAtype patch with various loading doses fitted Higuchi's diffusion equation. However, the permeation of naproxen through hairless mouse skin from PSA-type patch followed zero-order kinetics. In MCR-type patch, thickness of controlled release membrane affected on the drug release rate highly. In the composition of membrane, the release rate was decreased as the ratio of Eudragit increased. The drug release from the MCR-type patch followed zero order kinetics. The permeation of naproxen through hairless mouse skin from MCR-type patch showed lag time for the intial release period and didn't fit the zero-order kinetics

  • PDF

Adhesive Polyurethane-based Capacitive Electrode for Patch-type Wearable Electrocardiogram Measurement System (패치형 웨어러블 심전도 측정 시스템을 위한 접착성 폴리우레탄 기반의 용량성 전극)

  • Lee, Jeong Su;Lee, Won Kyu;Lim, Yong Gyu;Park, Kwang Suk
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.6
    • /
    • pp.203-210
    • /
    • 2014
  • Wearable medical device has been a resurgence of interest thanks to the development of technology and propagation of smart phone in recent years. Various types of wearable devices have been introduced and available in market. Capacitive coupled electrode which measures electrocardiogram over cloth is able to be applied wearable device. In previous approaches of capacitive electrode, they need proper pressure for stable contact of the electrode to body surface. However, wearable device that gives pressure on body surface is not suitable for long-term monitoring. In this study, we proposed adhesive polyurethane-based capacitive electrode for patch-type wearable electrocardiogram (ECG) monitoring device. Self-adhesive polyurethane make the electrode and whole system be adhered to the surface of skin without any pressure. The patch-type system is consisted of analog filter, analog-to-digital converter and wireless transmission module and designed to be attached on the body as a patch. To validate the feasibility of the developed system, we measured ECG signal in stable and active state and extracted heart rate. Therefore, we observed skin response after long-term attachment for biocompatibility of the adhesive polyurethane and adhesive strength of it. The result shows the possibility of applying the developed system for ECG monitoring in real-life.

Product Analysis and Development of Amblyopia Eye Patch for Children

  • Lim, Hosun;Sung, Juyoung
    • Fashion, Industry and Education
    • /
    • v.14 no.2
    • /
    • pp.1-10
    • /
    • 2016
  • In the present study, the materials, sizes, and designs of blind eye patch products of skin-adhesive type and glass-attachment type currently available in the market will be analyzed and ergonomically appropriate blind eye patches will be developed. Although these skin-adhesive type eye patches were easy to use, they had shortcomings such as skin troubles due to the adhesive used on the weak and sensitive skin of children and the fact that eyebrows are pulled out and the skin is irritated when the eye patches are detached after being attached. The non-adhesive type eye patches were blind patches to be worn by putting into glasses. These products were made using diverse materials such as neoprene, non-woven fabrics, and felt and showed differences in tactile impressions and irritation to the skin depending on material characteristics. In addition, most products were efficient in blocking light with three-dimensional oval designs comprising darts. In the present study, blind eye patches were designed to reduce skin troubles by using sweat-absorbing and quick-drying functional materials with soft tactile impressions. In addition, to increase the effect to block light and the degree of tight contact with the skin when the blind eye patches are worn compared to existing eye patch designs, the sides of the wings of the blind eye patches were widened, glass frame fixing plates were added, and the darts were made to be curved thereby making an ergonomic design reflecting the shape of the face. The non-adhesive type blind eye patches developed in the present study are considered to enhance the wearing sensation with the use of the material without skin irritation but with cushioning feelings and the ergonomic design reflecting the contour of the face.

Fatigue Crack Growth Behavior of the Thin-to-Thick Type Stiffened Panels with Bonded Patch (접착 패칭된 박-후판 결합형 보강판의 피로균열성장 거동)

  • Rhee, Hwan-Woo;Kim, Seung-Hyun
    • Journal of Ocean Engineering and Technology
    • /
    • v.22 no.3
    • /
    • pp.89-95
    • /
    • 2008
  • Fatigue cracked components often needs to be repaired during service. Standard repair schemes involve strengthening the component by connecting reinforcing members by means of rivets or welding by reducing the crack-tip stress intensity factors. Recent technological advances in fiber reinforced composite materials and adhesive bonding have led to the development of efficient repair schemes. In this study, the influence of various shape parameters on fatigue crack growth in the CCT type uniform thickness plates and the thin-ta-thick type stiffened panels repaired with woven fabric type Kevlar-Epoxy composite patch are studied experimentally.

A Study on Fatigue Crack Growth of Composite Patching Repaired on Cracked Thick Plate (복합재료 보강재로 보수되어진 균열을 가진 두꺼운 평판의 피로균열 성장에 관한 연구)

  • Jeong, Gi-Hyeon;Yang, Won-Ho;Go, Myeong-Hun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.12
    • /
    • pp.2070-2077
    • /
    • 2001
  • An experimental investigation of the effect of composite patching repair was conducted to characterize the fatigue crack growth behavior in thick A16061-T6 (6mm) panels with single bonded patch by fiber reinforced composite patch. Four patch lengths and no patch plate were examined. An analytical procedure, involving three-dimensional finite element method having three layers to model cracked aluminum plate, epoxy by adhesive and composite Patch, is calculated the stress intensity factors. From the calculated stress intensity factors, the fatigue crack growth rates are obtained. At the single patching type, different fatigue crack growth ratios through the palate thickness were investigated by using the experimental and analytical results. The results demonstrated that there was a definite variation in fatigue life depending on the size of composite patch. While crack reached the patch end, retardation of crack growth was also revealed in the bonded repair.

A Experimental Study on the Fatigue Crack Growth Behavior of Thick Plate with Repaired Crack (보수된 균열을 가진 두꺼운 평판의 피로균열 성장 거동에 관한 실험적 연구)

  • Chung, Ki-Hyun;Yang, Won-Ho;Kim, Cheol;Sung, Ki-Deug
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.292-298
    • /
    • 2001
  • An experimental investigation of the effect of composite patching repair was conducted to characterize the fatigue crack growth behavior in thick A16061-T6 (6mm) panels with single bonded patch by fiber reinforced composite patch. Four patch lengths and no patch plate were examined. An analytical procedure, involving three-dimensional finite element method having three layers to model cracked aluminum plate, epoxy by adhesive and composite patch, is calculated the stress intensity factors. From the calculated stress intensity factors, the fatigue crack growth rates are obtained. At the single patching type, different fatigue crack growth ratios through the plate thickness were investigated by using the experimental and analytical results. The results demonstrated that there was a definite variation in fatigue life depending on the size of composite patch. While crack reached the patch end, retardation of crack growth was also revealed in the bonded repair.

  • PDF

Design of Oral Patches for the Treatment of Aphthous Stomatitis : Drug Layer (아프타성 구내염 치료용 구강 패취의 설계 : 약물층)

  • Lee, Kyu-Hyun;Park, Eun-Seok;Chi, Sang-Cheol
    • Journal of Pharmaceutical Investigation
    • /
    • v.25 no.4
    • /
    • pp.339-345
    • /
    • 1995
  • For the effective treatment of aphthous stomatitis, the matrix type mucoadhesive patches containing triamcinolone acetonide have been formulated. The drug layer was obtained by drying the polymer gel which was prepared with carbomer 934P, ammoniomethacrylate copolymer, titanium dioxide and polyethylene glycol 400. The effects of the content of additives on physical characteristics of the polymer gel and the drug layer were evaluated. The addition of carbomer increased the yield point and the zero-shear viscosity of polymer gel as well as the thickness, the water absorption ratio, the adhesive time and $T_{50%}$ of drug layer. The adhesive time and the water absorption ratio of drug layer were also improved by the addition of ammoniomethacrylate copolymer, but the addition of titanium dioxide had decreased the zero-shear viscosity of polymer gel and the adhesive time of drug layer.

  • PDF

Analysis of Patched Cylindrical Shells with Circumferential Through-Wall Cracks (원주방향 관통균열을 갖는 원통형 쉘 구조의 패치보강 해석)

  • Ahn, Jae-Seok;Kim, Young-Wook;Woo, Kwang-Sung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.6A
    • /
    • pp.411-418
    • /
    • 2012
  • In this study, behavior of unpatched and patched cylindrical shells with through-wall cracks has been estimated using numerical experiments, and patching effect of them has been investigated according to various patching parameters. To show credibility of numerical models considered, two ways such as h- and p-methods have been adopted. Also, domain integral method and virtual crack extension method have been considered to calculate energy release rates based on linear elastic fracture mechanics. For examples, the unpatched cylindrical shells with circumferential cracks under remote tension have firstly been analyzed to show the validity of finite element modeling with h-method or p-method, and then the results have been compared with literature values published. Next, the sensitive analysis of patch repaired problems in terms of thickness of patch and adhesive, shear modulus of adhesive, composite material type of patch, crack length, etc. has been carried out.

Stress Intensity Factor of Single Edge Cracked Plates Considering Materials and Geometry of Patch by p-Convergent Partial Layerwise Model (p-수렴 부분층별모델에 의한 일변균열판의 패치재료 및 기하형상에 따른 응력확대계수)

  • Ahn, Hyeon-Ji;Ahn, Jae-Seok;Woo, Kwang-Sung
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.2
    • /
    • pp.191-198
    • /
    • 2010
  • This study investigated that the stress reduction of single edge cracked plates with patch repairs according to different type of patching such as material, size and thickness of patch and adhesive as well as single sided or double sided patches. As a numerical tool, the p-convergent partial layerwise model has been employed. The proposed model is formulated by assuming piecewise linear variation of in-plane displacement and a constant value of out-of-plane displacements across thickness. The integrals of Legendre polynomials are chosen to define displacement fields and Gauss-Lobatto numerical integration is implemented in order to directly obtain maximum values occurred at the nodal points of each layer without other extrapolation techniques. Also, total strain energy release rate method is adopted to obtain stress intensity factors. Numerical examples are presented not only to demonstrate the stress reduction effect in terms of non-dimensional stress intensity factor and deflection with respect to different type of patch repairs, but also the accuracy of proposed model.