• Title/Summary/Keyword: Adhesive method

Search Result 829, Processing Time 0.024 seconds

Interfacial Evaluation and Microfailure Sensing of Nanocomposites by Electrical Resistance Measurements and Wettability (전기저항측정법 및 젖음성을 이용한 나노복합재료의 미세파손 감지능 및 계면물성 평가)

  • Park, Joung-Man;Kwon, Dong-Jun;Shin, Pyeong-Su;Kim, Jong-Hyun;Baek, Yeong-Min;Park, Ha-Seung
    • Composites Research
    • /
    • v.30 no.2
    • /
    • pp.138-144
    • /
    • 2017
  • Damage sensing of polymer composite films consisting of poly(dicyclopentadiene) p-DCPD and carbon nanotube (CNT) was studied experimentally. Only up to 1st ring-opening polymerization occurred with the addition of CNT, which made the modified film electrically conductive, while interfering with polymerization. The interfacial adhesion of composite films with varying CNT concentration was evaluated by measuring the wettability using the static contact angle method. 0.5 wt% CNT/p-DCPD was determined to be the optimal condition via electrical dispersion method and tensile test. Dynamic fatigue test was conducted to evaluate the durability of the films by measuring the change in electrical resistance. For the initial three cycles, the change in electrical resistance pattern was similar to the tensile stress-strain curve. The CNT/p-DCPD film was attached to an epoxy matrix to demonstrate its utilization as a sensor for fracture behavior. At the onset of epoxy fracture, electrical resistance showed a drastic increase, which indicated adhesive fracture between sensor and matrix. It leads to prediction of crack and fracture of matrix.

Serological Studies on the Specific Antibodies Against P-pili of Uropathogenic Escherichia coli (요로 감염환자에서 혈청학적 방법을 이용한 P-pili특이혈중 항체의 조사)

  • 이원용;김종배
    • Biomedical Science Letters
    • /
    • v.2 no.1
    • /
    • pp.31-40
    • /
    • 1996
  • Escherichia coli is one of the most common etiological agents in urinary tract infection. An important virulence factor is the adhesive capacity of E. coli to uroepithelial cell, mediated by bacterial fimbriae. The Adhesion property has been regarded as an important virulence determinant in urinary tract infections. A total of 60 patients, who were diagnosed microbiologically as urinary tract infections, were examined by immunoblotting and enzyme-linked immunosorbent assay(ELISA). Uropathogenic E. coli with recombinant plasmid were positive for mannose resistant hemagglutination (MRHA). For identification of p-fimbriae subtype in uropathogenic E. coli, In the immunoblot analysis, specific bands in the range of p-fimbriae molecular weight of 17KD-22KD were identified. For the distribution of p-fimbriae subtype in the patient sera, 34/60(56.7%) were positive for $F7_1$, 28/60(46.7%) were positive for $F7_2$, and 30/60(50%) were positive for F13 with immunoblotting method. similar trends were observed in the enzyme-linked immunosorbent assay. Relatively good specificity(92.6%) and sensitivity(90%) were found in the ELISA test system using mixed antigens of purified $F7_1$, $F7_2$, and F13 p-fimbriae, and 60 sera from patients with urinary tract infections. In conclusion The serological tests were convenient method in diagnosis of urinary tract infections. among those ELISA could be recommended in diagnosis of urinary tract infections.

  • PDF

Proliposomal Clenbuterol Patch for Transdermal Delivery (프로리포솜을 이용한 클렌부테롤의 경피흡수 제제화)

  • Lee, Young-Joo;Chung, Suk-Jae;Lee, Min-Hwa;Shim, Chang-Koo
    • Journal of Pharmaceutical Investigation
    • /
    • v.27 no.4
    • /
    • pp.303-311
    • /
    • 1997
  • Proliposomal patch of clenbuterol, ${\beta}_2-agonist$ bronchodilator, was prepared and its feasibility as a novel transdermal drug delivery system was examined. Proliposomal granules containing clenbuterol was prepared by a standard method using sorbitol and lecithin with (Rx 2) or without cholesterol (Rx 1). The porous structure of sorbitol in the proliposomes was maintained allowing tree flowability of the granules. Following contact with water, the granules were converted probably to liposomes almost completely within several minutes. It indicates that proliposomes may be hydrated, when they are applied on the skin under occlusive condition in vivo, by the sweat to form liposomes. Clenbuterol release from Rx 1 and Rx 2 proliposomes to pH 7.4 isotonic phospate buffer (PBS) across cellulose membrane (mol. wt. cut-off of 12000-14000) was retarded significantly compared with that from the mixture of clenbuterol powder and blank proliposomes. Interestingly, proliposomes prepared with lecithin and cholesterol (i.e., Rx 2 proliposomes) showed much more retarded release of clenbuterol than proliposomes prepared only with lecithin (i.e.. Rx 1 proliposomes), indicating that clenbuterol release from proliposomes can be controlled by the addition of cholesterol to the proliposomes. Proliposomal patches were prepared using PVC film as an occlusive backing sheet, two sides adhesive tape (urethane, 1.45 mm thickness) as a reservoir for proliposome granules and Millipore MF-membrane (0.45 mm pore size) as a drug release-controlling membrane. Rx 1 or Rx 2 proliposomes containing 4.6 mg of clenbuterol were loaded into the reservoir of the patch. Clenbuterol release from the patches to pH 7.4 PBS was determined using USP paddle (50 rpm)-over-disc release method. Clenbuterol release from the proliposomal patches was much more retarded even than from a matrix type clenbuterol patch (Boehringer Ingelheim ltd). Being consistent with clenbuterol release from the proliposomal granules, the release from the patches was highly dependent on the presence of cholesterol in the proliposomes : Patches containing Rx 2 proliposomes showed several fold slower drug release than patches containing Rx 1 proliposomes. When the patch containing Rx 1 proliposomes was applied on to the back of a hair-removed rat, clenbuterol concentration in the rat blood was maintained during 6-72 hrs. Transdermal absorption of clenbuterol from the patch was accelerated when the patch was prehydrated with 50 ml of pH 7.4 PBS before topical application. Above results indicate that sustained transdermal delivery of clenbuterol is feasible using proliposomal patches if the cholesterol content and pore size of the release rate-controlling membrane of patches, for example, are appropriately controlled.

  • PDF

Evaluation of Durability and Slope Stability of Green Soil using Cementitious Materials (시멘트 계 재료를 사용한 녹생토의 내구성 및 사면 안정성 평가)

  • Kim, Il-Sun;Choi, Yoon-Suk;Yang, Eun-Ik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.5
    • /
    • pp.45-53
    • /
    • 2018
  • Among the various slope stabilization methods, the green soil method based on the growth of plants is advantageous to the environment, but the durability and slope stability are insufficient when the green soil method is applied to a steep slope and rock slope sites. Therefore, in this study, green soil, which improved the adhesion performance and the vegetation environment, was developed using cementitious materials and ECG, and the durability and slope stability as well as the possibility of its use as a rock vegetation base material were assessed. From the results, the adhesive force and internal friction angle were higher than that of the existing green soil so that it could be used for in situ construction. The soil hardness value was 26 mm, which was slightly higher than that of the best growth condition of the plant, 18~23 mm, and the drying shrinkage strain was approximately 3%; hence, it is not expected to affect the durability of green soil. The results of a rainfall intensity simulation for evaluating the slope adhesion force showed that slope failure did not occur under all conditions. The damage decreased with increasing slope angle. Therefore, the green soils developed in this study have excellent durability and slope stability and can be used for rock slope sites.

A STUDY ON THE EFFECT OF DENTIN BONDING AGENTS APPLIED OVER ENAMEL ABOUT THE BOND STRENGTH OF COMPOSITE RESIN (접착강화제가 치아경조직과의 접착강도 변화에 미치는 영향에 관한 연구)

  • Choi, Woong-Dae;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.1
    • /
    • pp.1-16
    • /
    • 1995
  • The purpose of this study was to investigate the effect of dentin bonding agents on the bond strength of composite resin restorations in case of applying the dentin bonding agents to acid etched enamel surfaces. Freshly extracted 364 bovine anterior teeth were selected as a adherents. 320 enamel specimens were divided into two groups(unetched group (1) and etched group (2) for testing the shear bond strength, 40 specimens were used for the hardness testing, and 4 specimens of rest were to observe the resin-tag formation into etched enamel surfaces. All surfaces of enamel specimens were polished with 320~1500 SiC paper under continuous running water. In Group (1), 100 enamel specimens were polished and unetched. 220 polished enamel specimens in Group (2) were etched with 37 % phosphoric acid solution for 60 seconds, washed with water for 20 seconds, and dried with a light air pressure for 60 seconds. Three kinds of dentin bonding agents(Gluma, Prisma, Scotchbond 2) were evaluated the effect on the bond strength to conditioned enamel surfaces. Shear bond strengths were measured on the three cases such as a coating of primer only, a coating of sealer only, and a sequential coating of primer and sealer to acid etched enamel surfaces were compared with the bond strengths measured by the coating of enamel bonding agent followed by the bonding of composite resin (Photo clearfil bright, Kuraray, Japan) to unetched and acid etched enamel surfaces. In addition, the hardness tested on the adhesive fractured surface between composite resin enamel as a mean of evaluation of a factor whether the mechanical bond strengths were affected and the penetration of dentin bonding agents into etched enamel surfaces was also observed. Bond strengths were measured using the method of shear bond strength by a universal testing machine (Instron-4467, USA), statistical test were applied to the results using a one way analysis variance(ANOVA), and hardness was measured by the Vicker's Hardness Tester(MHT-i, Matsuzawa, Japan) and the penetration of the resins were observed by the SEM (Hitachi, S-2300, Japan). The following conclusions were drawn; 1. Enamel bonding agent showed to affect the improvement of bond strength of composite resin to enamel surface both unetched and etched. 2. Dentin bonding agents could be resulted in increase of bond strength to unetched enamel surface, but there were no statistical significances. 3. Bond strengths to etched enamel surface were significantly decreased with a coating of dentin primer only. 4. Coating of sealer only and coating of primer and sealer noticed the similar bond strengths of composite resin to etched enamel using the enamel bonding agents. 5. The applying method proved to be more effective than the kinds of dentin bonding agents on the bond strength of composite resin to etched enamel than the kind of dentin. 6. Vicker's hardness numbers of dentin bonding agents were lower than that of composite resin, but the degree of penetration of dentin bonding agents into etched enamel surfaces was excellent.

  • PDF

Wear Properties of Hybrid Metal Matrix Composites (하이브리드 금속복합재료의 마모특성)

  • 부후이후이;송정일
    • Composites Research
    • /
    • v.16 no.3
    • /
    • pp.75-84
    • /
    • 2003
  • The purpose of this study is to investigate the wear properties of Saffil/Al, Saffil/A12O3/Al and Saffil/SiC/Al hybrid metal matrix composites fabricated by squeeze casting method. Wear tests were done on a pin-on-disk friction and wear tester under both dry and lubricated conditions. The wear properties of the three composites were evaluated in many respects. The effects of Saffil fibers, $\textrm{Al}_2\textrm{O}_3$ particles and SiC particles on the wear behavior of the composites were investigated. Wear mechanisms were analyzed by observing the worn surfaces of the composites. The variation of coefficient of friction(COF) during the wear process was recorded by using a computer. Under dry sliding condition, Saffil/SiC/Al showed the best wear resistance under high temperature and high load, while the wear resistances of Saffil/Al and Saffi1/$\textrm{Al}_2\textrm{O}_3$/Al were very similar. Under dry sliding condition, the dominant wear mechanism was abrasive wear under mild load and room temperature, and the dominant wear mechanism changed to adhesive wear as load or temperature increased. Molten wear occurred at high temperature. Compared with the dry sliding condition, all three composites showed excellent wear resistance when lubricated by liquid paraffin. Under lubricated condition, Saffil/Al showed the best wear resistance among them, and its COF value was the smallest. The dominant wear mechanism of the composites under lubricated condition was microploughing, but microcracking also occurred to them to different extents.

Manufacture of Wood Veneer-Bamboo Zephyr Composite Board: II. Effect of Manufacturing Conditions on Properties of Composite Board (목재 단판-대나무 제퍼 복합보드 제조: II. 복합보드의 성능에 미치는 제조조건의 영향)

  • Roh, Jeang Kwan
    • Journal of the Korean Wood Science and Technology
    • /
    • v.35 no.6
    • /
    • pp.108-117
    • /
    • 2007
  • This research was performed to investigate the feasibility of bamboo as a raw material for the manufacture of plywood. Wood veneer-bamboo zephyr composite boards (WBCB) were manufactured using keruing (Dipterocarpus sp.) veneers and hachiku bamboo (Phyllostacbys nigra var. henonis Stapf) using various adhesives, and the effect of the method and amount of resin spread on the mechanical properties of the composites were investigated. The WBCB manufactured using polymeric isocyanate (PMDI) showed the best mechanical properties, followed by phenol-formaldehyde resin (PF), phenol-melamine-formaldehyde resin, urea-melamine-formaldehyde resin, and urea-formaldehyde resin. However, considering the operation feasibility as well as mechanical properties, PF resin proved to be the appropriate adhesive for the practical purpose. As the amount of resin spread increased, the mechanical properties of 5-ply WBCB with 12 mm thicknesses manufactured using PF resin tended to increase, and more failure occurred at the interface between veneer and bamboo zephyr than at the interface among bamboo zephyrs. This result suggests that penetration of resin into bamboo zephyr could be the important factor. In this research, the appropriate amount of resin amount was $320g/m^2$. 5-ply WBCBs were manufactured using various methods of resin spread but the effect of the methods on the mechanical properties showed no little difference, which meant that the method of resin spread could be chosen considering the manufacturing conditions and operation feasibility.

Study of Spin Jig Development for Cleaning of the PCB component (PCB기판 세척용 스핀 지그개발에 관한 연구)

  • Lee, Seung-Chul;Park, Suk-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.8
    • /
    • pp.4736-4741
    • /
    • 2014
  • This study examined PCB component cleaning on a PCB component surface, which has defects of precipitation type washing (existing rinse method), sealant and foreign material formed in the adhesive process that could not be removed easily. The spin jig was developed for PCB component cleaning, in which the PCB component settled down, to solve the conventional problem of the removal of foreign material with the centrifugal force by high speed rotation. The results are as follows. With decreasing fraction defect in PCB component washing, the development and substrate damage decreased by more than 80% according to the abstergent in the rotary type using the centrifugal force in the existing precipitation type. When the base plate showed a large difference with the time to include the process after washing the design using the existing method, easy attachment and separation of the PCB component could be possible. The washing time was enhanced 90% compared to the existing time. The reliability of the security and washing collaboration of the design and stability of the cleaning process could be secured so that there was no phenomenon of secession, the PCB component fixed for a cleansing rotation jig could maintain a fixed force by the centrifugal force. The stability and reliability of the washing process and the defective rate could be improved to less than 1%.

A STUDY OF SHEAR BOND STRENGTH AND SURFACE CONDITION BETWEEN SURFACE TREATED PORCELAIN AND RESIN CEMENT (도재의 표면처리에 따른 레진시멘트와의 전단결합강도 및 표면상태에 관한 연구)

  • Park, Sang-Hyuck;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.144-155
    • /
    • 1997
  • This study evaluated shear bond strength between porcelain and resin cement according to various surface treatments of porcelain, and surface condition of debonded porcelain. 50 porcelain specimens(Celay block A2M7) and composite resin specimens(Clearfil Photo-Bright) were prepared, and divided into 5 experimental groups according to the treatment method of porcelain surface. 5 experimental groups by surface treatments were as follows; CONTROL Group : No surface treatment was done on the surface of porcelains. SAND Group : The surface of porcelains were sandblasted with $50{\mu}m$ aluminum oxide for 5 seconds. HF Group: The surface of porcelains were etched with 8% Hydrofluoric acid for 4 minutes. SIL Group: The surface of porcelains were coated with silane coupling agent and heated at $100^{\circ}C$ for 5 minutes. SAND+HF+SIL Group : The surface of porcelains were sandblasted with $50{\mu}m$ aluminum oxide for 5 seconds and etched with 8% Hydrofluoric acid for 4 minutes, and coated with silane coupling agent and heated at $100^{\circ}C$ for 5 minutes. After surface treatments on the prepared porcelain surface two pastes of Panavia 21$^{(R)}$ were mixed, they were applied between composite resin block and porcelain surface, and then excessive resin cements were removed, and its margin was surrounded with Oxyguard II. All specimens were stored for 24 hours in water at $37^{\circ}C$ and tested with Instron testing machine between porcelains and resin cements, and debonded porcelain surfaces were observed under Scanning Electon Microscope(Hitachi S-2300) at 20kvp. The values from each group were compared statistically by Student's t-test. The obtained results were as follows; 1. The shear bond strength without surface treatment of porcelain was the lowest among all experimental groups(p<0.05). 2. The detached porcelain surface with sandblasting alone had more remarkable cracks than with only Hydrofluoric Acid or Silane coupling 2gent, but showed the lowest value of shear bond strength among surface treated groups(p<0.05), 3. When porcelain surface was treated by hydrofluoric acid, it affected shear bond strength more than silane coupling agent, but there were no significant statistical differences(p>0.05). 4. When three methods were combined to increase shear bond strength between porcelains and resin cements, its value was the highest than the others(p<0.05). 5. In Scannig Electron Micrograph of detached porcelain surface with no treatment, the sample revealed adhesive failure between the porcelain and resin cement whereas detached porcelain surface with combination of three method cohesive failure on the porcelain.

  • PDF

A STUDY OF THE BOND STRENGTHS OF COMPOSITE RESIN TO DENTIN SURFACES PREPARED WITH MICROABRASIVE (Microabrasive로 처리한 상아질표면에 대한 복합레진의 결합강도에 관한 연구)

  • Choi, Kyoung-Kyu;Min, Byung-Soon
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.61-75
    • /
    • 1997
  • The bond strengths of composite resin to tooth dentin vary with the methods of cavity preparation and surface treatment. Recent developments in techniques of dentinal surface treatment have renewed interest in microabrasive as a means of tooth preparation, The purpose of this study was to determine the effects of a new method of cavity preparation on the bond of composite resin to dentin. Freshly extracted 144 healthy human third molars were used in this study. The dentin surfaces prepared with #600 SiC abrasive paper were divided into control and air abrasion groups according to the method of dentin surface preparation using different combinations of delivery pressure, time, and acid etching. The shear bond strengths were measured after the composite resin (Clearfil Photo Bright) was bonded to prepared dentin surfaces by light-curing using a dentin bonding system (All-bond 2), In addition, the average surface roughness was measured to investigate the effect of differently prepared dentin surfaces on the shear bond strengths. The surface changes of prepared dentin and the debonded dentin surfaces were observed with SEM (S-2300, Hitachi Co., Japan). The following results from this-study were obtained ; 1. There was no significant difference of shear bond strengths according to the changes of delivery pressure and time. 2. The shear bond strengths were lower than the control in the air abraded-only groups, but those of the additional acid-etched groups were higher than the control. 3. The shear bond strengths to all air-abraded surfaces were increased by acid etching. 4. The correlation between shear bond strengths and surface roughness was not certain, although the mean surface roughness of all air-abraded surfaces has increased evidently while it has slightly decreased for additional acid etching. 5. On SEM examination, the dentinal tubules were almost occluded in the air abraded-only groups, but those were opened in the additional acid-etched groups. 6. The debonded surfaces were showed adhesive failure mode in the air abraded- only groups, while those were showed mainly the mixed and cohesive failure mode in the additional acid-etched groups. These results suggest that the layer produced during cavity preparation or surface treatment with air abrasion must be removed for maximum bond strength of composite resin to dentin.

  • PDF