• Title/Summary/Keyword: Adhesive method

Search Result 829, Processing Time 0.033 seconds

Deposition of Protective Layer on Stealth Sheet and Evaluation of the Protected Sheet's Mechanical Performance (스텔스 소자의 보호층 도포 및 기계적 성능 평가 연구)

  • Sang Yeon So;Jae Won Hahn
    • Korean Journal of Optics and Photonics
    • /
    • v.34 no.5
    • /
    • pp.185-191
    • /
    • 2023
  • We report the results of evaluating the hardness, flexibility, and adhesion between the protective layer and the stealth sheet after applying a protective layer to improve the practicality of the flexible stealth sheet. The result of the ISO 15184 pencil hardness test showed that the hardness increased from HB to 3H by three grades when a protective layer was applied. The flexibility evaluation was conducted by bending the material against cylinders of certain diameters and observing whether cracks occurred according to the ASTM D522 test method. The result showed that the minimum diameter was 0.125 inches. The adhesion was evaluated by using the ASTM D3359 test method, attaching and peeling off an adhesive strip to the protective layer and determining the proportion of the protective layer peeling off. The result was 5B, which is better than the military adhesion limit of 4B.

Research on Rapid Disaster Prevention Measures due to Leakage During Transport of Hydrochloric Acid Tank Lorry (염산 탱크로리 운송 중 누출에 따른 신속 방재방안 연구)

  • Byoung-chan Moon
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.1
    • /
    • pp.213-221
    • /
    • 2024
  • Purpose: The purpose is to find the optimal way to quickly block the leak in the event of a leak accident in a tank lorry transporting hydrochloric acid aqueous solution, a hazardous chemical, and to carry out effective disaster prevention work to minimize damage caused by the leak. Method: We organized the overall characteristics of hydrochloric acid and accidents that occurred during transportation by accident type and cause, and created a small tank that can be tested assuming a leak situation in a hydrochloric acid tanker, creating an environment similar to the leak situation, and leaking in various ways. I would like to experiment and organize blocking methods. Result: Through experiments, an effective leak blocking method was confirmed. We would like to summarize measures to quickly block a leak in the event of a leak and present the optimal disaster prevention plan that can be applied at the accident site. Conclusion: It has been confirmed that using a combination of adhesive tape and magnets is more effective in blocking leaks. Rapid response is possible by repeatedly training business emergency response teams and product transporters to appropriately select and respond to leak-blocking equipment. Additional research on various leak prevention methods is needed in the future.

Method for the Assembly of a High-density Multi-channel Deformable Mirror for High Energy Lasers (고에너지 레이저용 고밀집 다채널 실리콘-카바이드 변형거울의 정밀 조립 방법)

  • Hyug-Gyo Rhee;Sunho Cho;Sihyun Kim;Jaehyun Lee;Pilseong Kang
    • Korean Journal of Optics and Photonics
    • /
    • v.35 no.4
    • /
    • pp.170-174
    • /
    • 2024
  • A laser beam propagating in free space can be negatively affected by atmospheric turbulence. To overcome this and correct the wavefront error of the laser beam itself, a deformable mirror (DM), which is a key component of adaptive optics, is widely used. In this paper, a novel precision assembling method is suggested for a multi-channel high-density DM. The material of the mirror sheet of the DM is silicon carbide (SiC), and the actuator is a stacked-type lead-magnesium-niobate (Pb(Mg1/3Nb2/3)O3; PMN). To connect the mirror sheet and each actuator, a flexure is inserted. The flexure can make the DM operate with full strokes without the failure of adhesive. A series of jigs were designed and applied in order to assemble these three parts (the mirror sheet, actuators, and flexures) precisely. After assembly, the performance of the DM was also checked.

Efficiency of ceramic bracket debonding with the Er:YAG laser (세라믹 브라켓의 제거 시 Er:YAG 레이저의 효능)

  • Suh, Chung-Hwan;Chang, Na-Young;Chae, Jong-Moon;Cho, Jin-Hyoung;Kim, Sang-Cheol;Kang, Kyung-Hwa
    • The korean journal of orthodontics
    • /
    • v.39 no.4
    • /
    • pp.213-224
    • /
    • 2009
  • Objective: The aim of this study was to find out whether Er:YAG laser can aid in debonding ceramic brackets, and to see what kind of method will be the most appropriate for debonding. Methods: One hundred and ninety teeth, monocrystalline brackets ($MISO^{TM}$, HT, Ansan-Si, Korea), polycrystalline brackets ($Transcend^{TM}$ series 6000, 3M Untek, Monrovia, CA, USA) and the KEY Laser3 (KavoDental, Biberach, Germany) were used. Experimental groups were classified according to the type of ceramic brackets, and the amount of laser energy (0, 140, 300, 450, 600 mJ). After applying laser on the bracket at two points at 1 pulse each, the shear bond strength was measured. The effect of heat caused by laser was measured at the enamel beneath the bracket and pulp chamber. After measuring the shear bond strength, adhesive residue was evaluated and enamel surface was investigated using SEM. Results: All ceramic bracket groups showed a significant decrease in shear bond strength as the laser energy increased. The greatest average temperature change was $3.78^{\circ}C$ on the enamel beneath the bracket and $0.9^{\circ}C$ on the pulp chamber. Through SEM, crater shape holes caused by the laser was seen on the enamel and adhesive surfaces. Conclusions: If laser is applied on ceramic brackets for debonding, 300 - 450 mJ of laser energy will be safe and efficient for monocrystalline brackets ($MISO^{TM}$), and about 450 mJ for polycrystalline brackets ($Transcend^{TM}$ series 6000).

A STUDY OF SHEAR BOND STRENGTH OF ER:YAG LASER-IRRADIATED PRIMARY DENTIN (Er:YAG 레이저를 조사한 유치 상아질의 전단결합강도에 관한 연구)

  • Lee, Jin-Hwa;Kim, Jong-Soo;Yoo, Seung-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.4
    • /
    • pp.569-578
    • /
    • 2007
  • This study was performed to compare the shear bond strength of self etching system and two bottle bonding system with or without laser preparation. Group I was prepared with high speed rotary instrument and $Prompt^{TM}$ L-$Pop^{TM}$, group II with Er:YAG laser and $Prompt^{TM}$ L-$Pop^{TM}$, group III with Er:YAG laser, 37% phosphoric acid and Single bond, group IV with Er:YAG laser and Single bond and group V with high speed, etching and Single bond. And also observation of the prepared and etched dentin surface were performed under scanning electro-microscope. The possibility of clinical application of laser preparation which might have an advantage to reduce pain for children with less unfavorable noise were evaluated. The results obtained are as follows; 1. Group V showed significantly higher bond strength than other groups. And group IV showed significantly lower bond strength than other groups. 2. There was no significant difference between group I and group III. 3. Group II showed significantly lower bond strength than group I, III, V, but showed significantly higher bond strength than group IV. 4. Under scanning electro-microscope, laser-preparated dentin surface showed high irregularity and no smear layer. The surface showed less irregularities and more exposed dentinal tubules with etching. Laser preparation has many advantages over conventional tooth preparation. But this method showed lower resin bonding strength. Laser preparated tooth surface differed from the conventionally preparated tooth surface. More researches are needed on suitable methods for laser preparated dentin surface.

  • PDF

THE BONDING DURABILITY OF RESIN CEMENTS (레진시멘트의 접착 내구성에 관한 연구)

  • Cho, Min-Woo;Park, Sang-Hyuk;Kim, Jong-Ryul;Choi, Kyoung-Kyu
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.4
    • /
    • pp.343-355
    • /
    • 2007
  • The objectives of this study was to evaluate the durability of 4 resin cements by means of microtensile bond strength test combined with thermocycling method and fractographic FE-SEM analysis. Experimental groups were prepared according to thermocycling (0, 1,000, 5,000) and the kind of resin cements, those were Variolink II, Multilink, Panavia F 2.0, Rely X Unicem. Flat dentin surfaces were created on mid-coronal dentin of extracted third molars. Then fresh dentin surface was grounded with 320-grit silicon carbide abrasive papers to create uniform smear layers. Indirect composite block (Tescera, Bisco Inc., Schaumburg, IL, USA) was fabricated ($12\;{\times}\;12\;{\times}\;6\;mm^3$). It's surface for bonding to tooth was grounded with silicon carbide abrasive papers from 180- to 600-grit serially, then sandblasted witk $20\;-\;50\;{\mu}m$ alumina oxide. According to each manufacturer's instruction, dentin surface was treated and indirect composite block was luted on it using each resin cement. For Rely X Unicem, dentin surface was not treated. The bonded tooth-resin block were stored in distilled water at $37^{\circ}C$ for 24 hours. After thermocycling, the bonded tooth-resin block was sectioned occluso-gingivally to 1.0 mm thick serial slabs using all Isomet slow-speed saw (Isomet, Buehler Ltd, Lake Bluff, IL, USA). These sectioned slabs were further sectioned to $1.0\;{\times}\;1.0\;mm^2$ composite-dentin beams. The specimens were tested with universal testing machine (EZ-Test, Shimadzu, Japan) at a crosshead speed of 1.0 mm/min with maximum load of 500 N. The data was analyzed using one-way ANOVA and Duncan's multiple comparison test at $p\;{\leq}\;0.05$ level. Within the limited results, we conclude as follows; 1. The bond strength of Variolink II was evaluated the highest among experimental groups and was significantly decreased after 1,000 thermocycling (p < 0.05). 2. The bond strength of Multilink was more affected by thermocycling than the other experimental groups and significantly decreased after 1,000 thermocycling (p < 0.05). 3. Panavia F 2.0 and Rely X Unicem showed the gradually decreased tendency of microtensile bond strength according to thermocycling but there was no significant difference (p > 0.05). 4. Adhesive based-resin cements showed lower bond strength with or without thermocycling than composite based-resin cements. 5. Variolink II & Multilink showed high bond strength and mixed failure, which was occurred with a thin layer of luting resin cement before thermocycling and gradually increased adhesive failure along the dentin surface after thermocycling. The bonding performance of resin cement can be affected by application procedure and chemical composition. Composite based-resin cement showed higher bond strength and durability than adhesive based-resin cement.

The Study of Nano-vesicle Coated Powder (나노베시클 표면처리 분체의 개발연구)

  • Son, Hong-Ha;Kwak, Taek-Jong;Kim, Kyung-Seob;Lee, Sang-Min;Lee, Cheon-Koo
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.32 no.1 s.55
    • /
    • pp.45-51
    • /
    • 2006
  • In the field of makeup cosmetics, especially, powder-based foundations such as two-way cake, pact and face powder, the quality of which is known to be strongly influenced by the properties of powder, surface treatment technology is widely used as a method to improve the various characteristics of powder texture, wear properties, dispersion ability and so on. The two-way cake or pressed-powder foundation is one of the familiar makeup products in Asian market for deep covering and finishing purpose. In spite of the relent progress in surface modification method such as composition of powders with different characteristics and application of a diversity of coating ingredient (metal soap, amino acid, silicone and fluorine), this product possess a technical difficulty to enhance both of the adhesion power and spreadability on the skin in addition to potential claim of consumer about heavy or thick feeling. This article is covering the preparation and coating method of nano-vesicle that mimic the double-layered lipid lamellar structure existing between the corneocytes of the stratum corneum in the skin for the purpose of improving both of two important physical characteristic of two-way cake, spreadability and adhering force to skin, and obtining better affinity to skin. Nano-vesicle was prepared using the high-pressure emulsifying process of lecithin, pseudo ceramide, butylene glycol and tocopheryl acetate. This nano-sized emulsion was added to powder-dispersed aqueous phase together with bivalent metal salt solution and then the filtering and drying procedure was followed to yield the nano-vesicle coated powder. The amount of nano-vesicle coated on the powder was able to regulated by the concentration of metal salt and this novel powder showed the lower friction coefficient, more uniform condition of application and higher adhesive powder comparing with the alkyl silane treated powder from the test result of spreadability and wear properties using friction meter and air jet method. Two-wav cake containing newly developed coated powder with nano-vesicle showed the similar advantages in the frictional and adhesive characteristics.

MICROLEAKAGE TEST ACCORDING TO ACID ETCHING TREATMENT IN CLASS V COMPOMERS (치면 산처리가 V급 와동의 compomer 수복에서 미세누출에 미치는 영향)

  • Moon, Sang-Hee;Lee, Chang-Seop;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.2
    • /
    • pp.351-360
    • /
    • 2000
  • The purpose of this study was to evaluate the microleakage of class V compomers according to acid etching treatment and treatment times. Extracted 180 sound human molar teeth were selected then prepared physiologic pulpal pressure far this experiment. In this study class V cavities were prepared on buccal surface with gingival margin located in 1mm superior to CEJ under simulate physiological conditions. These specimens were randomly divided into 6 groups of 30 each and restored following methods : A: Dyract AP + Prime&Bond 2.1 Group 1 : No acid etching, according to manufacturer's instruction. Group 2 : 15 seconds acid etching and same method with Group 1. Group 3 : 30 seconds acid etching and same method with Group 1. B: F2000 groups + Single Bond adhesive Group 1 : No acid etching, according to manufacturer's instruction. Group 2 : 15 seconds acid etching and same method with Group 1 Group 3 : 30 seconds acid etching and same method with Group 1. After 500 thermocycling between $5^{\circ}C\;and\;55^{\circ}C$, the specimens were sealed with glass ionomer and nail varnish then placed in 5% methylene blue dye for 5 hours and rinsed with tab water. The specimens were embedded in orthodontic clear resin, then sectioned buccolingually through the center of restoration with a low speed diamond saw. The dye penetration on each of the specimens were then observed with a stereomicroscope at $\times20$ magnification. The results of this study were statistically analyzed using the indepedent sample t-test and analysis of variance. Results were as follows, 1. In occlusal walls, microleakage were significantly reduced in acid etched group restored with Dyract AP but no statistically significance in F2000 groups. 2. In gingival walls, microleakage were significantly reduced in group 2 restored with Dyract AP, and group 2 and group 3 in F2000 groups. 3. All groups, except group 3 in Dyract AP, showed significantly less microleakage in occlusal wall than gingival wall. 4. No statistical significance were showed between group 2 and group 3 in both materials.

  • PDF

A Study on the Development of a Dry P0SCO E&C Fire Board Method with High Fire Resistance (건식화 P0SCO E&C Fire Board 공법 개발에 관한 연구)

  • Kim, Woo-Jae
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.721-724
    • /
    • 2008
  • The present study was to develop a dry PFB method similar to the existing gypsum board construction method in order to apply the existing wet PFB method that uses fire.resistant adhesive. It was found that the existing wet method can produce concrete compressive strength of 80MPa and fire resistance of 3 hours with 30mm PF boards. The goal of development in this study was fire resistance of 3 hours through dry construction of 15mm fire resistant boards. The results of fire resistance test showed an increase in thermal durability and thermal strain. It is believed that inorganic fiber reduces thermal strain, and lowers heat insulation performance by 15% or less. This suggests that heat insulation performance was improved by the change in the inner composition of PF board resulting from the adjustment of Al:Si mol ratio, high temperature molding, and dry curing. According to the results of fire resistance test, when the dry PF method was applied, the temperature of the main reinforcing bar was 116$^\circ$C in 15mm, 103.8$^\circ$C in 20mm, and 94$^\circ$C in 25mm, and these results satisfied the current standards for fire resistance control presented by the Ministry of Land, Transport and Maritime Affairs. When a 3 hour fire resistance test was performed and the external properties of the specimen were examined, the outermost gypsum board hardly remained and internal PF board maintained its form without thermal strain.

  • PDF

Joint Displacement Resistance Evaluation of Waterproofing Material in Railroad Bridge Deck (철도교량상판 방수재료 선정을 위한 균열거동저항 성능평가)

  • Bae, Young-Min;Oh, Dong-Cheon;Park, Yong-Gul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.683-692
    • /
    • 2020
  • A joint displacement resistance evaluation method for selecting waterproofing materials in railway bridge decks is proposed. The displacement range for an evaluation is determined by finite element method (FEM) analysis of a load case based on an existing high-speed PSC Girder Box railroad bridge structure. The FEM analysis results were used to calculate the minimum joint displacement range to be applied during testing (approximately 1.5 mm). For the evaluation, four commonly used waterproofing membrane types, cementitious slurry coating (CSC), polyurethane coating system (PCS), self-adhesive asphalt sheet (SAS), and composite asphalt sheet (CAS), were tested, with five specimens of each membrane type. The joint displacement width range conditions, including the minimum displacement range obtained from FEM analysis, were set to be the incrementing interval, from 1.5, 3.0, 4.5, and 6.0 mm. The proposal for the evaluation criteria and the specimen test results demonstrated how the evaluation method is important for the sustainability of high-speed railway bridges.