• Title/Summary/Keyword: Adhesion sheet

Search Result 145, Processing Time 0.025 seconds

A Study on the Adhesiveness between Polyurethane Sheet for Maxillofacial Prostheses and Autopolymerizing Acrylic Resin in Various Polymerization Methods (다양한 중합방법에 따른 악안면 보철용 폴리우레탄과 자가중합 레진 간의 결합력에 관한 연구)

  • Kim, Doo-Yeol;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.16 no.2
    • /
    • pp.123-132
    • /
    • 2000
  • The field of maxillofacial prosthetics is concerned with the prosthetic reconstruction of missing head and neck tissue. Currently, facial prostheses are usually applied in cases of defects caused by the surgical removal of tumors or congenital defects. While silicone has been most widely used for the reconstruction of missing maxillofacial defects, it does not have ideal physical properties. Therefore, bonding a thin polyurethane sheet to silicone prostheses was recommended. In this case skin adhesives were used for the retention of maxillofacial prostheses. But retention of devices has always been problematic. The contributions of implants can be made to solve these problems. Implants have reduced the need for adhesive use, simplifying cleaning procedures and thus extending the life of the prostheses. For implant-retained prostheses, retentive matrix is necessary to hold attachments and/or magnets. The retentive matrix is usually fabricated with autopolymerizing acrylic resin or visible light- polymerized resin. The purpose of this study was to compare the adhesion-in-peel force of silicone adhesive to autopolymerizing acrylic resin and polyurethane sheet with two different surface textures : pumice polish only or retention groove, and three surface primers : Dow corning 1205 primer or Dow corning S-2260 primer or FactorII A-304 primer, and two polymerization methods : room temperature or dry heat oven. The t-peel bond strength of specimens was determined as described in ASTM Standard D1876-72. The results were statistically analyzed using the ANOVA test, multiple range test and t-test The results were as follows. 1. The t-peel bond strength of A-304 primer was the highest and statistically higher than that of S-2260(p<0.05). 2. The t-peel bond strength of specimens with retention groove was statistically higher than that of specimens polished with pumice(p<0.05). 3. The t-peel bond strength of specimens polymerized in dry heat oven was statistically higher than that of specimens in room temperature(p<0.01).

  • PDF

Development of a process to apply uniform pressure to bond CFRP patches to the inner surface of undercut-shaped sheet metal parts (언더컷 형상의 판재 성형품에 보강용 CFRP 패치의 접합을 위한 공정기술 개발)

  • Lee, Hwan-Ju;Jeon, Yong-Jun;Cho, Hoon;Kim, Dong-Earn
    • Design & Manufacturing
    • /
    • v.14 no.4
    • /
    • pp.65-70
    • /
    • 2020
  • Partial reinforcement of sheet metal parts with CFRP patch is a technology that can realize ultra-lightweight body parts while overcoming the high material cost of carbon fiber. Performing these patchworks with highly productive press equipment solves another issue of CFRP: high process costs. The A-pillar is the main body part and has an undercut shape for fastening with other parts such as roof panels and doors. Therefore, it is difficult to bond CFRP patches to the A-pillar with a general press forming tool. In this paper, a flexible system that applies uniform pressure to complex shapes using ceramic particles and silicone rubber is proposed. By benchmarking various A-pillars, a reference model with an undercut shape was designed, and the system was configured to realize a uniform pressure distribution in the model. The ceramic spherical particles failed to realize the uniform distribution of high pressure due to their high hardness and point contact characteristics, which caused damage to the CFRP patch. Compression equipment made of silicone rubber was able to achieve the required pressure level for curing the epoxy. Non-adhesion defects between the metal and the CFRP patch were confirmed in the area where the bending deformation occurred. This defect could be eliminated by optimizing the process conditions suitable for the newly developed flexible system.

Performance Characteristics of CVD Diamond Cutting Tools

  • Oles, E.J.;Cackowski, V.J.
    • The Korean Journal of Ceramics
    • /
    • v.2 no.4
    • /
    • pp.203-211
    • /
    • 1996
  • CVD diamond tools are becoming more widely used in industry as an economic alternative to polycrystalline diamond (PCD) for machining non-ferrous and non-metallic materials. Although CVD diamond-sheet tools have been on the market for several years, diamond-coated carbide inserts have become available only recently, with the successful resolution of long-standing adhesion problems. Diamond coating morphology on the rake surface of the tool affects chip formation favorably, whereas a microscopically rough, faceted morphology on the flank surface of the tool produces a rough workpiece finish. Workpiece finish can be improved by using a coated tool with a larger nose radius. The tool life provided by diamond-coated tools(~30 $\mu\textrm{m}$ thick) can meet or exceed that of PCD tools, depending on the characteristics of the workpiece material. When using diamond-coated carbide tools in milling, a sharp-edged PCD tool should be used in the wiper position of the cutter to minimize workpiece roughness and burr formation.

  • PDF

Fabrication and characterization of fe-Ni Invar alloy thin films (Fe-Ni Invar 합금 박막의 증착 및 박막 특성 평가)

  • 김상섭;고영호;최장현;김병일;박용범
    • Journal of the Korean Vacuum Society
    • /
    • v.8 no.2
    • /
    • pp.116-120
    • /
    • 1999
  • Fe-Ni alloy thin films with about 3.5 $\mu\textrm{m}$ thickness were successfully grown on Al-killed steel substrates employing DC magnetron sputtering method, and then the4 film properties were characterized. The deposited film exhibited a fibre texture structure with the relationship of ${110}_\textrm{film}//{111}_\textrm{substrate}$. We found that the adhesion between the film and the substrate was fairly good considering no debonding behavior after the thermal cyclic test of 5,000 times from room temperature to $200^{\circ}C$. Also we found that the Fe-Ni alloy deposition induced a significant decrease of thermal expansion in the film processing, a new material system with much lower thermal expansion coefficient which can be applied more as shadow mask materials than an Al-killed steel sheet.

  • PDF

Fabrication and Characterization of Bi-Based Frit Film for PDP Transparent Dielectric Front Panel (PDP 투명 유전체용 Bi계 프릿트 필름의 제조 및 특성분석)

  • Lee, Sang-Jin;Kim, Joo-Won;Hwang, Jong-Hee
    • Journal of the Korean Ceramic Society
    • /
    • v.44 no.10
    • /
    • pp.548-553
    • /
    • 2007
  • Ceramic green sheets consisting Bi-based glass frit were fabricated for an application to PDP transparent dielectric front panel. The dispersion condition of the slurry for tape casting was pre-examined, and two kinds of hinder and plasticizer were used in the non-aqueous slurry system. In the fabrication process for the frit film, the properties such as dry and firing shrinkage, elongation, and transmittance were examined at the condition of various mixing ratio of plasticizers. In the mixing ratio of polyethylene glycol to dibutyl phthalate of 3:5wt%, a good adhesion, elongation and transmittance were observed at the firing temperature of $580^{\circ}C$. The photograph for the cross section of the interface was also showed a dense microstructure.

The Use of Graphene for Regenerative Medicine (그래핀의 재생의학적 이용)

  • Yoon, Jeong-Kee;Kim, Byung-Soo
    • KSBB Journal
    • /
    • v.27 no.5
    • /
    • pp.273-280
    • /
    • 2012
  • Graphene is a one-atom-thick sheet composed of carbon atoms only. It has a two-dimensional honeycomb structure with $sp^2$ orbital bonding, which presents some unique properties. Due to large Young's modulus, good electrical conductivity, ability to immobilize several kinds of small molecules and proteins, and biocompatibility of graphene, it has attracted interests inits ability to enhance cell growth and differentiation, followed by recent several studies. We reviewed about the osteogenic differentiation of mesenchymal stem cells, and neurogenic differentiation of neuron stem cells, and the ectodermal and mesodermal differentiation of induced pluripotent stem cells using graphene. Graphene has not only enhanced the adhesion and proliferation of mesenchymal stem cells, but also led to the faster differentiation even without any other exogenous signals. Nonetheless, graphene has some cytotoxicities in its amount-response manner, which is critical to regenerative medicine. The cytotoxicities of graphene were compared with those of grapheneoxide and carbon nanotubes.

High Dose $^{60}Co\;{\gamma}$-Ray Irradiation of W/GaN Schottky Diodes

  • Kim, Jihyun;Ren, F.;Schoenfeld, D.;Pearton, S.J.;Baca, A.G.;Briggs, R.D.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.4 no.2
    • /
    • pp.124-127
    • /
    • 2004
  • W/n-GaN Schottky diodes were irradiated with $^{60}Co\;{\gamma}-rays$ to doses up to 315Mrad. The barrier height obtained from current-voltage (I-V) measurements showed minimal change from its estimated initial value of ${\sim}0.4eV$ over this dose range, though both forward and reverse I-V characteristics show evidence of defect center introduction at doses as low as 150 Mrad. Post irradiation annealing at $500^{\circ}C$ increased the reverse leakage current, suggesting migration and complexing of defects. The W/GaN interface is stable to high dose of ${\gamma}-rays$, but Au/Ti overlayers employed for reducing contact sheet resistance suffer from adhesion problems at the highest doses.

Investigation of Design Parameters of Single Sided Linear Induction Motor for MAGLEV (자기부상열차용 편측식 선형 유도전동기의 설계특성 검토)

  • Park Yeong-Ho;Choi Yeol-Jun;Kim Jeong-chul;Choi Jong-Mook
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.49-54
    • /
    • 2005
  • Linear metro with single sided linear induction motor is applied to the urban transit system because of non adhesion drive. But linear induction motor is required to reduce the energy consumption to maximize efficiency of LIM. In this paper, design requirements such as pole pitch, motor length, air gap, overhang length and the material of secondary sheet are investigated as major parameter of SLIM. It is effective for increasing the efficiency to adopt the copper reaction plate and decrease the mechanical air gap as small as possible.

  • PDF

Characteristics of Ni-Carbon Nanotube Composite Coatings with the CNT Content (CNT 첨가량에 따른 Ni-CNT 복합도금막의 특성)

  • Bae, KyooSik
    • Journal of the Semiconductor & Display Technology
    • /
    • v.12 no.3
    • /
    • pp.7-12
    • /
    • 2013
  • Ni-CNT(Carbon Nanotube) composite coatings is were formed by electrodeposition and their physical properties were investigated with variations of CNT content(1, 3, 6. 9 g/L) in the electrolyte solution, while the current density and electroplating time were fixed respectively at $6A/dm^2$ and 90 min.. With increasing CNT content from 1 to 9 g/L, incorporated CNTs into the composite coating were limited from 4.65 wt.% to 7.38 wt.%. Microhardness and contact angle values were increased with increasing CNT content of upto 3 g/L. With increasing the CNT content further, physical properties were degraded due to agglomeration, poor adhesion of CNTs to Ni matrix and thus rough surfaces. Optimum electroplating conditions were found to be the CNT content of 3 g/L, current density of 6 A/dm2 and electroplating time of 90 min.

Experimental Study on the Shear Strengthening Effect of Cracked or Uncracked RC Columns with Carbon Fiber Sheets (균열 및 비균열 철근콘크리트 기둥의 탄소섬유시트 전단보강효과에 관한 실험적 연구)

  • Na, Jung-Min;Lee, Yong-Taeg;Kim, Seung-Hun;Lee, Li-Hyung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.6 no.4
    • /
    • pp.243-254
    • /
    • 2002
  • This study investigates the structural behavior of cracked or uncracked RC columns retrofitted with CFS and evaluates the shear retrofit performance through experiment. Experimental works were conducted for sixth specimens varied in the adhesion method of CFS, the ratio of shear reinforcement bar, and the existence of crack before retrofitting. Throughout cyclic test, the strength, stiffness, failure modes, and ductility are discussed. The test results show that the retrofitting method with CFS improve the shear strength and ductility. The crack width below 2mm, occurred before retrofitting, didn't reduce the shear strengthening effect.