• Title/Summary/Keyword: Adhesion Test

Search Result 1,105, Processing Time 0.025 seconds

Effect of Adhesion Strength Between Flexible Substrates and Electrodes on the Durability of Electrodes (유연 기판과 전극 사이의 접합력이 전극의 내구성에 미치는 영향)

  • Doyeon Im;Byoung-Joon Kim;Geon Hwee Kim;Taechang An
    • Journal of Sensor Science and Technology
    • /
    • v.33 no.2
    • /
    • pp.86-92
    • /
    • 2024
  • Flexible electronic devices are exposed to repeated mechanical deformation; therefore, electrode performance is an important element. Recently, a new technology has been developed to improve the adhesion strength between polymer substrates and metal thin films through the cross-linking reaction of bovine serum albumin (BSA) bioconjugation proteins; however, additional performance evaluation as an electrode is necessary. Therefore, in this study, we investigated the effect of adhesive strength between a flexible substrate and a metal thin film on the performance of a flexible electrode. Cracks and changes in the electrical resistance of the electrode surface were observed through outer bending fatigue tests and tensile tests. As a result of a bending fatigue test of 50,000 cycles and a tensile test at 10% strain, the change in the electrical resistance of the flexible electrode with a high adhesion strength was less than 40%, and only a few microcracks were formed on the surface; thus, the electrical performance did not significantly deteriorate. Through this study, the relationship between the adhesion strength and electrical performance was identified. This study will provide useful information for analyzing the performance of flexible electrodes in the commercialization of flexible electronic devices in the future.

Nanotribological Characteristics of Silicon Surfaces Modified by IBAD (IBAD로 표면개질된 실리콘 표면의 나노 트라이볼로지적 특성)

  • Park, Ji-Hyun;Yang, Seung-Ho;Kong, Ho-Seung;Jhang, Kyung-Young;Yoon, Eui-Sung
    • Tribology and Lubricants
    • /
    • v.18 no.1
    • /
    • pp.1-8
    • /
    • 2002
  • Nano adhesion and friction between a $Si_{3}N_{4}$ AFM(atomic force microscope) tip and thin silver films were experimentally studied. Tests were performed to measure the nano adhesion and friction in both AFM and LFM(lateral force microscope) modes in various range of normal loads. Thin silver films deposited by IBAD (ion beam assisted deposition) on Si-wafer (100) and other Si-wafers of different surface roughness were used. Results showed that nano adhesion and friction decreased with the surface roughness. When the Si surfaces were coated by pure silver, the adhesion and friction decreased. But the adhesion and friction were not affected by the thickness of IBAD silver coating. As the normal force increased, the adhesion forces of bare Si-wafer and IBAD silver coating film remained constant, but the friction forces increased linearly. Test results suggested that the friction was mainly governed by the adhesion as long as the load was low.

Adhesion Characteristics of Polymer Material Treated by Atmospheric Pressure Plasma (상압 플라즈마 표면처리에 의한 고분자 재질의 접착특성 변화)

  • Seo, Seung-Ho;Chang, Sung-Hwan;Yoo, Yeoung-Een;Chung, Jae-Dong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.5
    • /
    • pp.445-450
    • /
    • 2011
  • We studied the adhesion characteristics of polymer films (PC, PET, EVA) treated by atmospheric pressure plasma. The process parameters were the frequency, gas flow, and treatment time; we studied the effects of these parameters on the adhesion characteristics of the polymer materials. We used de-ionized water and diiodomethane as the polar and nonpolar solvents, respectively, for measuring the contact angles, and subsequently calculated the surface free energy of each polymer film. The adhesion characteristics were studied by carrying out a $180^{\circ}$ peel-off test. The polymer films treated with plasma developed a hydrophilic surface, which led to increased surface free energy and improved adhesion properties. From the results for contact angle, surface free energy, and adhesion strength, we obtained the optimal plasma-treatment conditions.

Comparative Analysis of Substrate Wet Surface Adhesion and Substrate Movement Response Performance Testing Methods for Injection Type Repair Materials Used in Leakage Cracks of Concrete Structure in Underground Environment (지하 습윤 환경에서 콘크리트 구조물 균열 누수에 사용되는 주입형 보수재료의 부착 성능과 거동 대응 성능 평가의 상관성 분석 연구)

  • Kim, Soo-Yeon;Oh, Kyu Hwan;Oh, Snag-Keun
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.9
    • /
    • pp.19-26
    • /
    • 2018
  • The focus of this study was centered around 15 common injection type water leakage repair materials (3 different types for each; synthetic polymer, cementitious, acrylic, epoxy, urethane) used in concrete structures of Korea and analyzing their wet surface adhesion performance in accordance to the ISO TS 16774 Test Method for Repair Materials for Water-leakage Cracks in Underground Concrete Structures, Part 4: Test Method for Adhesion on Wet Concrete Surface, and the results of this study was taken to be place under a comparative analysis with the results of the preceeding study on response to substrate movement performance study. The results of this comparative study showed that other than 1 specimen of 1 type of the acrylic and 3 specimens of 1 type of the synthetic polymer type materials, all of the 93% of the specimens used in this study showed stable adhesion on wet substrate surface, and we were able to determine that materials that have proper response properties against substrate movement are highly flexible and have high adhesion properties, but their adhesion properties on wet substrate would change based on their viscosity.

Characteristics of Bond Strength with Measuring Methods of Concrete (시험방법에 따른 신ㆍ구 콘크리트의 부착강도 특성)

  • 장흥균;김성환;홍창우;윤경구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.597-600
    • /
    • 2003
  • The development and maintenance of a sound bond are an essential requirements of concrete repair and replacement. The bond property of a bonded overlay to its substrate concrete during the lifetime is one of the most important performance requirements which should be quantified. A standard or a verified bond strength measurement method is required at field for screening, selecting materials and quality control for overlay or repair materials. This study compares the nipple pipe direct tensile test, flexural adhesion test, and core pull-off test with their test results. Substantial differences in the failure stresses of three test methods were attributed to their different geometries and loading conditions. From these comparison and investigation, core pull-off test was relatively good because the coefficient of variation values were about 2%. It would be suitable for use in-situ because of its simplicity and accuracy.

  • PDF

A study on the re-adhesion control algorithm of railway traction (도시철도차량 인버터 재점착제어기법 연구)

  • Kim, Gil-Dong;Han, Young-Jae;Park, Hyun-June;Lee, Sa-young
    • Journal of the Korean Society for Railway
    • /
    • v.2 no.1
    • /
    • pp.56-66
    • /
    • 1999
  • This purpose of this paper is to perform the readhesion control algorithm of the urban railway traction. A study on readhesion control algorithm is done for the adhesion system. This system has all characteristics of the voltage source converter by a process ability to regenerate power. The traction motor is controlled by IGBT inverter. The test equipment composes traction motor, torque-meter, clutch, and a tubular type of interia mass.

  • PDF

The slip & slide simulator for train using induction motors (유도전동기를 이용한 열차의 공전활주 모의 시험기)

  • Byun, Yeun-Sub;Kim, Min-Soo;Lee, Young-Hoon;Kim, Young-Chol
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.1879-1880
    • /
    • 2006
  • In electric motor coaches, when the adhesion force between rail and driving wheel decreases suddenly, the electric motor coach has slip phenomena. The characteristics of adhesion force coefficient is strongly affected by the conditions between rails and driving wheels, such as moisture, dust, and oil on the rails and so on. This paper proposes the simulation system for slip & slide test using virtual train. We can easily research the adhesion characteristics and adhesion control method with this equipment under the sudden variation of the adhesion force coefficient.

  • PDF

Plasma and VUV Pretreatments of Polymer Surfaces for Adhesion Promotion of Electroless Ni or Cu Films

  • Romand, M.;Charbonnier, M.;Goepfert, Y.
    • Journal of Adhesion and Interface
    • /
    • v.4 no.2
    • /
    • pp.10-20
    • /
    • 2003
  • This paper is relative to the electroless deposition of nickel or copper films on polyimide and polytetrafluoroethylene substrates. First, it is presented an original approach of the electroless process which consists in grafting nitrogenated functionalities on the polymer surfaces via plasma or VUV-assisted treatments operating in a nitrogen-based atmosphere ($NH_3$, $N_2$), and then in catalysing the grafted surfaces in an aqueous tin-free, Pd(+2)-based solution. Adhesion of the Pd(+2) catalytic species on polymer surfaces is explained by the formation of strong covalent bonds between these species and the grafted nitrogenated groups. Second, it is show how a fragmentation test performed in conjunction with electrical measurements can be used to characterize the practical adhesion of the electroless coatings deposited on flexible polymer substrates, and to evidence the influence of some experimental parameters (plasma treatment time and nature of the gas phase).

  • PDF

Study on the Adhesive Properties of Polyesters Reinforcing Materials

  • Krump, H.;Hudec, I.;Cernak, M.;Janypka, P.
    • Elastomers and Composites
    • /
    • v.37 no.3
    • /
    • pp.192-194
    • /
    • 2002
  • Polyester cord yarns have been treated in an atmospheric-pressure nitrogen plasma reactor in order to enhance their adhesion to rubber. A thin layer or the plasma was generated in the close vicinity of the yam surface using various types or surface discharge. To assess the effect of the plasma treatment on fiber surface properties, the cord thread/rubber matrix adhesion values measured using the untreated and threads cord threads were compared. The static and dynamic adhesion of the cord thread to rubber was characterized by using the standard Henley test. The dynamic adhesion values for the reference and plasma treated fiber were $7,3{\pm}1,2\;N$ and $83,5{\pm}3,5\;N$. The surface properties were investigated by scanning electron microscopy, infrared spectroscopy and electron spin resonance spectroscopy. It is concluded that both polar group interactions and increased surface area of the fibers are responsible for the improved adhesive strength.

A Study for Mechanical and Platelet Adhesion Properties of Fluorinated Polyurethanes (불소화된 폴리우레탄의 기계적 물성과 혈소판 점착특성에 관한 연구)

  • 김형중
    • Polymer(Korea)
    • /
    • v.25 no.3
    • /
    • pp.343-348
    • /
    • 2001
  • The mechanical and the platelet adhesion properties of the fluorinated polyurethane elastomers synthesized with a perfluorinated polyether diol (Fomblin ZDOL$ZDOL^{(R)}$) and 4,4'-diphenyl methane diisocyanate (MDI) were investigated. The change of mechanical properties with the Fomblin content and the type of the polyether diol was investigated by applying a designed technique using in vitro platelet adhesion test. As a result, the tensile properties were affected by the content and the type of nixed polyether diols. Also the platelet adhesion of polyurethane elastomers decreased with increasing the extent of fluorination in the polymer.

  • PDF