• Title/Summary/Keyword: Adhesion Test

Search Result 1,103, Processing Time 0.034 seconds

Study on the Thermal Properties of the Electroless Copper Interconnect in Integrated Circuits (집적회로용 무전해도금 Cu배선재료의 열적 특성에 관한 연구)

  • 김정식;이은주
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.6 no.1
    • /
    • pp.31-37
    • /
    • 1999
  • In this study, the thermal property and adhesion of the electroless-deposited Cu thin film were investigated. The multilayered structure of Cu /TaN /Si was fabricated by electroless-depositing the Cu thin layer on the TaN diffusion barrier which was deposited by MOCVD on the Si substrate. The thermal stability was investigated by measuring the resistivity as post-annealing temperature for the multilayered Cu /TaN /Si specimen which was annealed at atmospheres of $H_2$and Ar gases, respectively. The adhesion strength of Cu films was evaluated by the scratch test. The adhesion of the electroless-deposited Cu film was compared with other deposition methods of thermal evaporation and sputtering. The scratch test showed that the adhesion of electroless plated Cu film on TaN was better than that of sputtered Cu film and evaporated Cu film.

  • PDF

Influence of Surface Finishing Material Types to Formaldehyde and Volatile Organic Compounds Emission from Plywood

  • Kim, Ki-Wook;Oh, Jin-Kyoung;Lee, Byoung-Ho;Kim, Hyun-Joong;Lee, Young-Kyu;Kim, Sung-Hun;Kim, Gwan-Eui
    • Journal of the Korean Wood Science and Technology
    • /
    • v.36 no.2
    • /
    • pp.39-45
    • /
    • 2008
  • Formaldehyde and volatile organic compounds (VOCs) are emitted from wood-based panels that have been made using wood particles, wood fiber, wood chips, formaldehyde-based resins and so on. In this study, we examined formaldehyde and total VOCs (TVOC) emission behaviors for plywood overlaid with water-soluble phenolic resin impregnated linerboard (PL), and two kinds of surface materials (decorative veneer and pre-impregnated finishing foil) that were adhered onto the PL that named DPL and PPL. EVA (ethyl vinyl acetate) was used to overlay the decorative veneer and pre-impregnated finishing foil on the plywood with water-soluble phenolic resin impregnated linerboard by a hot press instrument. The debonding test and accelerated aging test were conducted to assess their mechanical properties. Formaldehyde and TVOC emission concentrations were measured using the FLEC method and a VOC Analyzer, respectively. The debonding test results of PL, DPL and PPL were 1.2, 1.5, and $0.5N/mm^2$, respectively. The surface appearance of the samples were not changed after the accelerated aging test. The PL and DPL exhibited reduced formaldehyde and TVOC emission levels, respectively. In the case of PPL, the VOC value was relatively higher than those of PL and DPL.

Influence of Surface Treatment on Adhesion between Pt Nanoparticle and Carbon Support

  • Kim, Jong Hun;Choi, Han Shin;Yuk, Youngji;Park, Jeong Young
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.598-598
    • /
    • 2013
  • The short lifetime of Proton Exchange Membrane Fuel Cell (PEMFC) is the one of the main problems to be solved for commercializing. Especially, the weak adhesion between metal nanoparticles and supports deteriorate the performances of nanocatalysts, therefore, it is considered to be a major failure mechanism. Using force-distance spectroscopy of atomic force microscopy (AFM), we characterized the adhesion between Pt nanoparticles and carbon supports that is crucially related to the durability for membrane fuel cell (MFC) electrode. In our study, force distance curves measured with Pt coated AFM cantilever, mimicking the behavior of corresponding nanoparticles on carbon supports, leads to the adhesion between metal nanoparticles and carbon supports. We found that theadhesion between Pt and HNO3-treated carbon is enhanced by a factor of 4, compared to Pt and bare carbon support, that is consistent with the macroscopic durability test of PEMFC. The higher adhesion between Pt and HNO3-treated carbon can be explained in light of the stronger chemical interaction by C/O functional groups.

  • PDF

Effect of Temperature on the Micro-scale Adhesion Behavior of Thermoplastic Polymer Film (열가소성 폴리머 필름의 마이크로 점착 거동에 대한 온도의 영향)

  • Kim, Kwang-Seop;Heo, Jung-Chul;Kim, Kyung-Woong
    • Tribology and Lubricants
    • /
    • v.25 no.2
    • /
    • pp.86-95
    • /
    • 2009
  • Adhesion tests were carried out in order to investigate the effect of temperature on the adhesion behavior between a PMMA film and a fused silica lens in the micro scale. For the tests, a microtribometer system was specially designed and constructed. The pull-off forces on the PMMA film were measured under atmospheric condition as the temperature of the PMMA film was increased from 300 K to 443 K and decreased to 300 K. The contact area between the PMMA film and the lens was observed during the test. The adhesion behavior was changed with the change of the PMMA surface state as the temperature increased. In glassy state below 363 K, the pull-off force did not change with the increase of temperature. In rubbery state from 383 K to 413 K, the pull-off force increased greatly as the temperature increased. In addition, the area of contact was enlarged. In viscous state above 423 K, the fingering instability was observed in the area of contact when the PMMA film contacted with the lens. It was also found that the adhesion behavior can be varied with the thermal history of the PMMA film. The residual solvent in the PMMA film could emerge to the PMMA surface due to the heating and reduced the pull-off force.

Effect of Heat Treatment on the Adhesive Strength of Electoless Nickel Deposits (무전해법으로 Slide Glass 위에 도금된 Ni층의 접착력에 미치는 열처리의 영향)

  • Hyun, Yong-Min;Yu, Sung-Yeol;Yoon, Jung-Yun;Kim, Bo-Young;Kim, Sun-Ji;Tahk, Song-Hee;Kim, Hee-San
    • Journal of the Korean institute of surface engineering
    • /
    • v.44 no.6
    • /
    • pp.246-249
    • /
    • 2011
  • Surface modification before coating nickel by coupling agents and/or etchant of glass did not provide enough adhesive strength of electroless nickel deposits on glass. Effect of heat treatments on hardness as well as adhesion of nickel deposits was studied by using tape test for adhesion, nanoindenter for hardness and glancing angle x-ray diffractometer (GAXRD) for phase characterization. Heat treatment improved hardness as well as adhesion. XRD results give that the improvements of adhesion and hardness are due to the formation of $NiSiO_4$ around the interface between the nickel deposits and the glass and the precipitation of $Ni_3P$ causing precipitation hardening, respectively. The details in effects of heat treatment on adhesion and hardness are described here.

Adhesion and Electrical Performance by Plasma Treatment on Semiconductive-Insulation Interface Layer of Silicone Rubber (실리콘 고무의 플라즈마 표면처리된 반도전-절연계면 처리에 따른 접착특성과 절연성능)

  • Hwang, Sun-Mook;Lee, Ki-Taek;Hong, Joo-Il;Huh, Chang-Su
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05b
    • /
    • pp.11-14
    • /
    • 2004
  • In this paper, the effect of adhesion properties of semiconductive-insulating interface layer of silicone rubber on electrical properties was investigated. The modifications produced on the silicone surface by oxygen plasma were accessed using ATR-FTIR, contact angle and AFM. Adhesion was obtained from T-peel tests of semiconductive layer having different treatment durations. In addition, ac breakdown test was carried out for elucidating the change of electrical property with duration of plasma treatment. From the results, the treatment in the oxygen plasma produced a noticeable increase in surface energy, which can be mainly ascribed to the the creation of O-H and C=O. It is observed that adhesion performance was determined by not surface energy but roughness level of silicone surface. It is found that ac dielectric strength was increased with improving the adhesion between the semiconductive and insulating interface.

  • PDF

Adhesion and Diffusion Barrier Properties of $TaN_x$ Films between Cu and $SiO_2$ (Cu 박막과 $SiO_2$ 절연막사이의 $TaN_x$ 박막의 접착 및 확산방지 특성)

  • Kim, Yong-Chul;Lee, Do-Seon;Lee, Won-Jong
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.16 no.3
    • /
    • pp.19-24
    • /
    • 2009
  • Formation of an adhesion/barrier layer and a seed layer by sputtering techniques followed by electroplating has been one of the most widely used methods for the filling of through-Si via (TSV) with high aspect ratio for 3-D packaging. In this research, the adhesion and diffusion-barrier properties of the $TaN_x$ film deposited by reactive sputtering were investigated. The adhesion strength between Cu film and $SiO_2$/Si substrate was quantitatively measured by $180^{\circ}$ peel test and topple test as a function of the composition of the adhesive $TaN_x$ film. As the nitrogen content increased in the adhesive $TaN_x$ film, the adhesion strength between Cu and $SiO_2$/Si substrate increased, which was attributed to the increased formation of interfacial compound layer with the nitrogen flow rate. We also examined the diffusion-barrier properties of the $TaN_x$ films against Cu diffusion and found that it was improved with increasing nitrogen content in the $TaN_x$ film up to N/Ta ratio of 1.4.

  • PDF

The study on the influence of surface cleanness and water soluble salt on corrosion protection of epoxy resin coated carbon steel

  • Shon, MinYoung
    • Corrosion Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.163-169
    • /
    • 2014
  • The corrosion resistance of epoxy-coated carbon steel was evaluated. The carbon steel surface was subjected to different treatment methods such as steel grit blasting and power tool treatment as well as contamination of water soluble salt. To study the effect of the surface treatments and contamination, the topology of the treated surface was observed by confocal microscopy and a pull-off adhesion test was conducted. The corrosion resistance of the epoxy-coated carbon steel was further examined by electrochemical impedance spectroscopy (EIS) combined with immersion test of 3.5 wt% of NaCl solution. Consequently, the surface contamination by sodium chloride with $16mg/m^2$, $48mg/m^2$ and $96mg/m^2$ didn't affect the adhesion strength for current epoxy coated carbon steel and blister and rust were not observed on the surface of epoxy coating contaminated by various concentration of sodium chloride after 20 weeks of immersion in 3.5 wt% NaCl aqueous solutions. In addition, the results of EIS test showed that the epoxy-coated carbon steel treated with steel grit blasting and power tool showed similar corrosion protection performance and surface cleanness such as Sa 3 and Sa 2.5 didn't affect the corrosion protectiveness of epoxy coated carbon steel.

Proposal of Bond Strength Evaluation Method for Overlay Concrete at Field (유한요소해석을 이용한 현장 덧씌우기 콘크리트의 부착강도 평가 방법 제안)

  • Lee, Bong-Hak;Hong, chang-Woo;Lee, Joo-Hyung;Kim, Seong-Hwan
    • Journal of Industrial Technology
    • /
    • v.21 no.B
    • /
    • pp.295-300
    • /
    • 2001
  • Significant improvements in bond strength between new and existing concrete can be achieved through the modification of the new concrete by latex modification. But, no test method has been adopted as a standard to measure the bond strength between the concrete used to repair and the substrate being repaired. The performance of old and the new concrete construction defends upon band strength between old and the new concrete. Current adhesion strength measurement method is inaccurate method that ignore effect of stress concentration by shape of specimens. Therefore, this research calculates stress concentration coefficient using finite element analysis and direction tensile strength test (pull-off test). The result shows that the required core depth is 2.5 cm. Elastic modulus and overlay thickness do not influence in stress concentration.

  • PDF

Proposal of Bond Strength Evaluation Method for Bridge Deck Overlay (교면 덧씌우기 콘크리트의 부착강도 평가 방법 제안)

  • 장흥균;홍창우;정원경;이봉학;윤경구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.349-354
    • /
    • 2002
  • Significant improvements in bond strength between new and existing concrete can be achieved through the modification of the new concrete by latex modification. But, no test method has been adopted as a standard to measure the bond strength between the concrete used to repair and the substrate being repaired. The performance of old and the new concrete construction depends upon bond strength between old and the new concrete. Current adhesion strength measurement method ignores the effect of stress concentration by shape of specimens. Therefore, this research calculates stress concentration coefficient using finite element analysis and direction tensile strength test (pull-off test). The result shows that the required core depth is 2.5cm. Elastic modulus and overlay thickness do not influence in stress concentration.

  • PDF