• 제목/요약/키워드: Addressable thermal sensor

검색결과 4건 처리시간 0.017초

온도센서 배열 모니터링에 의한 매질의 투수성 및 절리 연결성 연구 (A Study on the medium seepage and the fracture connectivity by using temperature monitoring with thremal line sensors)

  • 김중열;김태희;김유성
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.1110-1119
    • /
    • 2006
  • If water flows through a narrow passage into a medium that keeps the equilibrium of temperature, it causes small temperature difference and makes a temperature anomaly. The seepage or leakage often observed at old dams is a representative example of bringing about a temperature anomaly. Therefore, temperature measurements have been regarded as one of excellent methods that can detect the situation of seepage or leakage. However, because existing temperature measurement methods are based on a single sensor, the application of the method to the whole structure is nearly not possible in technical and economical phases. This paper introduces a temperature monitoring system using a thermal sensor cable that is comprised of addressable thermal sensors connected in parallel at many positions within a single cable. Through various laboratory and field experiments, it has been proved that the temperature monitoring technique can give an useful information about permeability of a medium or connectivity of fractures which have been regarded as difficult problems.

  • PDF

다중온도센서를 통한 입체적인 호소 온도모니터링 평가 (Spatial Reservoir Temperature Monitoring using Thermal Line Sensor)

  • 황기섭;박동순;정우성
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2006년도 학술발표회 논문집
    • /
    • pp.1002-1006
    • /
    • 2006
  • Temperature monitoring techniques per depth have been recognized as important information in the reservoir environmental issues. However, old measurement method by single temperature sensor and cable type has demerits not only for its limited measuring location but for its inconvenience of users. In this study, multi-channel temperature monitoring system was introduced and executed experiment for actual application feasibility evaluation. Both type of new techniques such as multi-channel addressable built-in temperature sensor and fiber optic multi sensor were tested in Daechung and Imha reservoir. As a result, it was proved that these kinds of temperature monitoring skills had very good performance and availability for a output of spatial, simultaneous thermal distribution focused on the user's convenience. And these measuring method and thermal data will be useful for providing basic information in a water resources investigation like reservoir stratification and environmental problems.

  • PDF

온도 모니터링을 위한 광섬유 센서와 온도센서 배열 케이블의 비교 연구 (A Study on the Comparison between an Optical Fiber and a Thermal Sensor Cable for Temperature Monitoring)

  • 김중열;김유성;송윤호
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.1100-1109
    • /
    • 2006
  • In this study, two different technologies which can measure temperature simultaneously at many points are introduced. One is to use a thermal sensor cable that is comprised of addressable thermal sensors connected in parallel within a single cable. The other is to use an optic fiber with Distributed Temperature Sensing (DTS) system. The difference between two technologies can be summarized as follows. A thermal sensor cable has a concept of 'point sensing' that can measure temperature at accurate position of a thermal sensor. So the accuracy and resolution of temperature measurement are up to the ability of the thermal sensor. Whereas optic fiber sensor has a concept of 'distributed sensing' because temperature is measured by ratio of Stokes and anti-Stokes component intensities of Raman backscatter that is generated when laser pulse travels along an optic fiber. It's resolution is determined by measuring distance, measuring time and spatial resolution. The purpose of this study is that application targets of two temperature measurement techniques are checked in technical and economical phases by examining the strength and weakness of them. Considering the functions and characteristics of two techniques, the thermal sensor cable will be suitable to apply to the assessment of groundwater flow, geothermal distribution and grouting efficiency within 300m distance. It is expected that the optic fiber sensor can be widely utilized at various fields (for example: pipe line inspection, tunnel fire detection, power line monitoring etc.) which need an information of temperature distribution over relatively long distance.

  • PDF

온도 모니터링을 위한 광섬유 센서와 온도센서 배열 케이블의 비교 연구 (A Study on the Comparison between an Optical Fiber and a Thermal Sensor Cable for Temperature Monitoring)

  • 김중열;송윤호;김유성
    • 한국지반공학회논문집
    • /
    • 제23권4호
    • /
    • pp.15-24
    • /
    • 2007
  • 본 연구에서는 여러 지점의 온도를 동시에 측정할 수 있는 두 가지 온도 모니터링 기법을 소개하고 있다. 그 하나는 고유주소를 가지고 있는 온도센서로 구성된 온도센서 배열 케이블을 이용하는 기법이며, 다른 하나는 광섬유 센서를 이용하여 분포 온도를 측정하는 기법이다. 이 두 기법의 차이점은 다음과 같이 요약될 수 있다. 온도센서 배열 케이블은 온도센서가 위치하는 정확한 지점의 온도를 측정하게 된다. 그에 대한 온도 측정의 정밀도 및 분해능은 그 온도 센서의 성능에 따라 결정된다. 한편, 광섬유 센서는 레이저 펄스가 광섬유를 따라 보내질 때 생성되는 Raman 역산란파를 분석함으로써 온도를 측정하기 때문에 분포 개념의 온도를 측정하게 된다. 그에 대한 온도 분해능은 측정거리, 측정시간 및 온도측정 거리분해능에 따라 결정된다. 본 논문은 두 가지 온도 모니터링 시스템의 장단점을 비교함으로써 기술적이고 경제적인 측면에서 그의 응용분야를 면밀히 검토하는 데 그 목적이 있다. 이를 위해 두 기법을 이용한 다양한 실험을 실시하였다. 그 결과를 검토해 보면 온도센서 배열 케이블은 300m 범위 내의 지하수 흐름, 지열 분포 및 그라우팅 효과 검증에 적합할 것으로 판단되며 광섬유 센서는 상대적으로 긴 거리에 걸친 분포 온도에 대한 정보가 필요한 파이프 파인 감시, 터널 화재 감시 및 전력선 모니터링과 같은 분야에서 효율적으로 활용될 것이 기대된다.