A Study on the medium seepage and the fracture connectivity by using temperature monitoring with thremal line sensors

온도센서 배열 모니터링에 의한 매질의 투수성 및 절리 연결성 연구

  • Kim, Jung-Yul (Soam Consultant Co., Ltd.) ;
  • Kim, Tae-Hee (Groundwater Resources Group, Groundwater & Geothermal Resources Division, Korea Institute of Geoscience & Mineral Resources) ;
  • Kim, Yoo-Sung (Soam Consultant Co., Ltd.)
  • 김중열 ((주) 소암컨설턴트) ;
  • 김태희 (한국지질자원연구원 지하수지열연구부 지하수자원연구실) ;
  • 김유성 ((주) 소암컨설턴트)
  • Published : 2006.03.24

Abstract

If water flows through a narrow passage into a medium that keeps the equilibrium of temperature, it causes small temperature difference and makes a temperature anomaly. The seepage or leakage often observed at old dams is a representative example of bringing about a temperature anomaly. Therefore, temperature measurements have been regarded as one of excellent methods that can detect the situation of seepage or leakage. However, because existing temperature measurement methods are based on a single sensor, the application of the method to the whole structure is nearly not possible in technical and economical phases. This paper introduces a temperature monitoring system using a thermal sensor cable that is comprised of addressable thermal sensors connected in parallel at many positions within a single cable. Through various laboratory and field experiments, it has been proved that the temperature monitoring technique can give an useful information about permeability of a medium or connectivity of fractures which have been regarded as difficult problems.

Keywords