• Title/Summary/Keyword: Added filter

Search Result 392, Processing Time 0.026 seconds

Study on dose and image quality by Added filter and Grid change when exam abdominal fluoroscopy (복부투시조영 검사 시 Added filter와 Grid 변화에 따른 선량 및 화질에 관한 연구)

  • Hong, Seon Sook;Kang, Kyeong Mi;Seong, Min Suk;Lee, Jong Woong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.47-56
    • /
    • 2012
  • Amount of radiation exposure by seeing through fluoroscopy examination while is many patient exposure administration and unprepared misgovernment be. In this study, abdominal fluoroscopy during the scan, the dose and image quality change according to the use of grid and added filter optimized by measuring the test condition is proposed. Uses seeing through fluoroscopy examination equipment of Image Intensifier of Easy Diagnost Eleva (Philips), under tube type and uses Human phantom and measures average area dose according to grid insertion existence and nonexistence and added filter kind change. Measure sum of 29 organ dose and effective dose through PCXMC imagination simulation program and image J program through noise, SNR, image distortion was measured. Resolution, sharpness, and analyzed using the MTF curves. Fluorography the grid to insert the filter thickness and thickening and increased the average area dose and organ doses and effective dose. In the case of spot examination, when inserted grid, average area dose and organ dose and effective dose increased. Filter thickens the average area dose decreased, but the organ doses and effective dose were increased when use 0.2mmCu+1mmAl filter, decreased slightly. Noise and SNR measurements without inserting the gird, if you do not use the added filter was the lowest and when measure the distortion, 0.1mmCu+1mmAl filter was no difference of image quality in case insert grid was judged that when did not use occasion added filter that do not use grid, difference of image quality does not exist. Did not show a big difference, according to the grid and uses of the added filter sharpness, and resolution. Patient dose increases with factors that reduce the quality of the image so reckless grid and the use of the added filter when abdominal fluoroscopy examination should be cautious in using.

  • PDF

The Manufacture of Antioxidant Filter and Removal Efficiency of the Free Radicals in Mainstream Smoke (항산화 필터 제조 및 주류연중 free radicals 제거 효과)

  • Kim, Soo-Ho;Cha, Sung-Je;Shim, Weon-Tack;Cheong, Bong-Su;Seo, Man-Seok;Song, In-Beom;Jang, Hang-Hyun;Shin, Chang-Ho;Kim, Jong-Yeol;Kim, Chung-Ryul;Choi, Yoon-Joo
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.31 no.1
    • /
    • pp.18-28
    • /
    • 2009
  • This study describes the manufacturing method of antioxidant filter and evaluate the reduction of free radical and biological activity from mainstream smoke. When we used spray-brush for the application of antioxidant solution to the filter, cv(coefficient of variation) levels of antioxidant added to filter ranged within 3 %, which means stable and constant feeding process. 0.3~0.5mg per cigarette of antioxidant were sprayed to acetate and active carbon part in the filter plug, respectively. It was considered that the use of antioxidant added filter resulted in the reduction of the gaseous compounds of free radicals from 17 % to 19 % in the mainstream smoke. Variation for removal efficiency of free radical in antioxidant filter added to acetate part was more pronounced than that of filter added to active carbon part. Smoking deliveries of tar, nicotine for the antioxidant added filters were similar when comparing to the non-antioxidant added filter, but the delivering amounts of isoprene were significantly reduced. The estimation of consumed GSH(glutathion) showed that the gaseous toxicity of the antioxidant added filter was 14 % ~ 23 % lower than that of non-antioxidant added filter. No significant differences were observed for the total taste quality in sensory evaluation.

HVL Measurement of the Miniature X-Ray Tube Using Diode Detector (다이오드 검출기를 이용한 초소형 X선관(Miniature X-ray Tube)의 반가층 측정)

  • Kim, Ju-Hye;An, So-Hyeon;Oh, Yoon-Jin;Ji, Yoon-Seo;Huh, Jang-Yong;Kang, Chang-Mu;Suh, Hyunsuk;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.279-284
    • /
    • 2012
  • The X ray has been widely used in both diagnosis and treatment. Recently, a miniature X ray tube has been developed for radiotherapy. The miniature X ray tube is directly inserted into the body irradiated, so that X rays can be guided to a target at various incident angles according to collimator geometry and, thus, minimize patient dose. If such features of the miniature X ray tube can be applied to development of X ray imaging as well as radiation treatment, it is expected to open a new chapter in the field of diagnostic X ray. However, the miniature X ray tube requires an added filter and a collimator for diagnostic purpose because it was designed for radiotherapy. Therefore, a collimator and an added filter were manufactured for the miniature X ray tube, and mounted on. In this study, we evaluated beam characteristics of the miniature X ray tube for diagnostic X ray system and accuracy of measuring the HVL. We used the Si PIN Photodiode type Piranha detector (Piranha, RTI, Sweden) and estimated the HVL of the miniature X ray tube with added filter and without added filter. Through an another measurement using Al filter, we evaluated the accuracy of the HVL obtained from a direct measurement using the automatic HVL calculation function provided by the Piranha detector. As a result, the HVL of the miniature X ray tube was increased around 1.9 times with the added filter mounted on. So we demonstrated that the HVL was suitable for diagnostic X ray system. In the case that the added filter was not mounted on, the HVL obtained from use of the automatic HVL calculation function provided by Piranha detector was 50% higher than the HVL estimated using Al filter. Therefore, the HVL automatic measurement from the Piranha detector cannot be used for the HVL calculation. However, when the added filter was mounted on, the HVL automatic measurement value using the Piranha detector was approximately 15% lower than the estimated value using Al filter. It implies that the HVL automatic measurement can be used to estimate the HVL of the miniature X ray tube with the added filter mounted on without a more complicated measurement method using Al filter. It is expected that the automatic HVL measurement provided by the Piranha detector enables to make kV-X ray characterization easier.

Assessment of Bacteria Removal Using Silver Ion Absorbed Ceramic Filter

  • Kim, Woo-Hang;Smith, James
    • Journal of Environmental Science International
    • /
    • v.21 no.8
    • /
    • pp.901-907
    • /
    • 2012
  • The objective of this study was to evaluate bacteria removal ability of the metallic silver which was baked silver ion impregnated ceramic filter at heating condition. Silver leaking from baked ceramic filter was tested to sustain bacteria removal for a long time. Silver impregnated ceramic filter could remove E. coli completely at $10^{12}$ MPN/100ml to $10^{13}$ MPN/100ml of influent. However, ceramic filter without silver did not remove E. coli completely under the same condition. After baking, the silver impregnated ceramic filter almost didn't leak out the silver ion from filter. Photo of TEM (Transmission Electron Microscopy) showed that absorbed silver ions remained in ceramic filter after baking process and most of silver were less than 10 nm. According to the increase in the amount of silver in the ceramic filter, removal efficiencies of E. coli were increased but turbidity removal was decreased. It can be accounted that increased removal efficiency of E. coli was from disinfection of silver that is in the ceramic filter. Simulated concentrations of bacteria agree well with the observed experimental effluent concentration data. Moreover, first-order decay coefficients increased to 0.0034/min after silver was added in the ceramic filter. Increase of first-order decay coefficient proves that silver-added ceramic filter can remove bacteria easily.

A Study on Modified Adaptive Median Filter for Impulse Noise Removal (임펄스 잡음 제거를 위한 변형된 적응 메디안 필터에 관한 연구)

  • Long, Xu;An, Young-Joo;Kim, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.804-806
    • /
    • 2014
  • During the transmission process of processing of image, various noises are added causing an error to the image. In order to restore these images, methods such as alpha trimmed average filter, standard median filter and switching median filter were proposed but such previous methods has insufficient noise suppression characteristics. Therefore in this paper, in order to remove the impulse noise added to the image, an adaptive median filter algorithm modified to expand the mask according to the noise density of mask pixels was proposed.

  • PDF

A Study of Radiation Dose and Quality by Using Added Filtration in Chest Radiography (흉부(胸部) X선촬영시(線撮影時) 부가여과사용(附加濾過使用)에 따른 선양(線量)과 선질(線質)에 관(關)한 연구(硏究))

  • You, Byung-Hun;Chu, Sung-Sil;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.10 no.1
    • /
    • pp.13-23
    • /
    • 1987
  • Author has studied for finding the method of decreasing the radiation dose and increasing diagnostic range in chest X-ray radiography. The study for the added filter thickness from half value layer to 1/8 value layer by decreasing curve and research for the exposure factors, decreasing ratio of radiation dose, ratio of scatter ray and image quality in chest X-ray radiography. The results were as follows: 1. By using the rare earth intensifying screen system at 120 Kvp, the sensitivity is increased by times and the exposure ratio is decreased 0.22 by comparison with the $CaWO_{4}$ intensifying screen system at 80 Kvp. 2. By using Al added filter of 1/8 value layer, the scatter ray is increased more than no filter, But the scatter ray is decreased more in $G_{4}/RxOG$ intensifying system than in LT-II/Rx intensifying system. 3. At 120 Kvp, the image quality value of $G_{4}/RxOG$ system is increased more than LT-II/Rx system compared with slight decreasing image quality value at 80 Kvp. Concluded that by using the added filter could decrease the radiation dose by 1/3 and obtain effective image quality with the added filter at high voltage hard exposure.

  • PDF

Image Restoration Algorithm for Image Noise Removal in Mixed Noise Environment (복합잡음 환경에서 영상 잡음제거를 위한 영상복원 알고리즘)

  • Long, Xu;Kim, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.112-114
    • /
    • 2014
  • Generally, images are corrupted by the impulse or AWGN and there are cases where both of these noises are added at once. When it comes to eliminating the noises added to the image, the previous median filter is effective in removing the impulse noise and the average filter is effective for removing AWGN. However, when the complex noises are added, it lacks the noise suppression characteristics, thus in this paper, a non-linear filter algorithm for removing the complex noises was proposed. The simulation results shows the proposed algorithm has excellent de-noising capabilities of compare existing methods.

  • PDF

A Study on Added Filters for Reduction of Radiation Exposure Dose in Skull A-P Projection (머리부 전후방향촬영 시 방사선피폭선량 저감을 위한 부가여과판에 대한 연구)

  • Lee, Cho-Hee;Lim, Chang-Seon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.7
    • /
    • pp.3117-3122
    • /
    • 2011
  • Skull A-P projections are the bi-product where the ESD (Entrance Surface Dose) for digital radiography is much higher than that conventional screen-film radiography. Therefore, the aim of this study was to reduce radiation doses to patients by using an added filter. This research focuses on the identification of the reduction of exposure to radiation based on the thickness of an added filter when applying the 'Skull A-P Projection' by using the 'Skull Phantom'. Also, an experiment was conducted to evaluate the qualitative decline of images through filtration. The measurement of one's exposed dose to radiation was executed by locating the 'Skull Phantom' on the position of the 'Skull AP,' while changing 16 kinds of added filters from 0.1 mmAl to 0.5 mmCu + 2.0 mmAl in terms of incident and penetrating doses. For the qualitative evaluation of images, a total number of 17 images have been acquired in the 'Skull Phantom' under the same conditions as those for the measurement of one's exposed dose. The acquired images have been evaluated by a radiological specialist. As a result, the images with a diagnostic value have been obtained by using such added filters as the compound filter of 0.2 mmCu +1.0 mmAl. The exposed dose absorbed on the 'Skull Phantom' is about 0.6 mGy. The value is only 12% of 5 mGy, the ESD value acquired on the 'Skull P-A Projection', which is recommended by the International Atomic Energy Agency (IAEA). As a result, depending on the parts of inspection, it is possible to reduce the patient's exposed dosage of radiation considerably by using an appropriate added filter.

Numerical Analysis for Modeling of Sound Absorbing Medium using Transmission Line Matrix Modeling (전달선로행렬법을 이용한 흡음재 모델링에 대한 수치해석)

  • Park, Kyu-Chil;Yoon, Jong-Rak
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.8
    • /
    • pp.1599-1605
    • /
    • 2012
  • We introduced an approach of modeling of a sound absorbing medium that had different absorbing coefficient according to frequency. To obtain the time domain result of the frequency characteristics of a sound absorbing medium, transmission line matrix modeling was used. To input sound absorbing effect in TLM modeling, we added a FIR filter at a node instead of absorbing component using resistance component. There were simulated the characteristics of time-shift, low pass filter, high pass filter using the FIR filter with 7-tap coefficients, then compared with theoretical results. From various simulation results, we could find that added FIR filter coefficient in TLM modeling was an useful way to model a sound absorbing medium.

EMG Signal Elimination Using Enhanced SVD Filter in Multi-Lead ECG (향상된 SVD 필터를 이용한 Multi-lead ECG에서의 EMG 신호 제거)

  • Park, Kwang-Li;Park, Se-Jin;Choi, Ho-Sun;Jeong, Kee-Sam;Lee, Kyoung-Joung;Yoon, Hyoung-Ro
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.50 no.6
    • /
    • pp.302-308
    • /
    • 2001
  • SVD(Singular Value Decomposition) filter for the suppression of EMG in multi-lead stress ECG is studied. SVD filter consists of two parts. In the first part, the basis vectors were chosen from the averaged singular vectors obtained from the decomposed noise-free ECG. The singular vector is computed from the stress ECG and is compared itself with basis vectors to know whether the noise exist in stress ECG. In the second part, the existing elimination method is used, when one(or two) channels is(or are) contaminated by noise. But the proposed enhanced SVD filter is used in case of having the noise in the many channels. During signal decomposition and reconstruction, the noise-free channel or the least noisy channel have the weight of 1, the next less noisy channel has the weight of 0.8. In this way, every channel was weighted by decreased of 0.2 in proportion to the amount of the added noise. For the evaluation of the proposed enhanced SVD filter, we compared the SNR computed by the enhanced SVD filter with the standard average filter for the noise-free signal added with artificial noise and the patient data. The proposed SVD filter showed better in the SNR than the standard average filter. In conclusion, we could find that the enhanced SVD filter is more proper in processing multi-lead stress ECG.

  • PDF