• 제목/요약/키워드: Adaptive Vibration Control

검색결과 175건 처리시간 0.025초

ANFIS를 이용한 수평회전형 도립진자의 제어 (Control of Rotary Inverted Pendulum using ANFIS)

  • 민현기;유창완;고재호;임화영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 B
    • /
    • pp.681-683
    • /
    • 1998
  • Fuzzy Inference System is to trans late and be concrete with human expert in to mathematical equation. It is easy to be applied for Nonlinear System and the know ledge can be applied at that. With using the rule according to the Knowledge, when it is realized simulations must be required repeatedly and small vibration is generated in steady state, too. In this paper, we applied the system to the methodology of optimization with self-learn ing by us ing ANFIS(Adaptive Network-based Fuzzy Inference System) which makes use of back-propagation and least square method at a first order Sugeno Fuzzy System. In order to show the effect of Algorithm, we demonstrated it by us ing Rotary Inverted Pendulum.

  • PDF

반사파가 있는 관내의 능동 소음제어 (Active Noise Control in a Duct With Reflected Wave)

  • 오상헌;김양한
    • 소음진동
    • /
    • 제4권2호
    • /
    • pp.187-198
    • /
    • 1994
  • This study is to describe the effects of the duct termination conditions conditions upon the active noise attenuation system. The adaptive filtering algorithm using FIR filter is implemented for duct noise attenuation. To avoid the instability caused by the acoustic feedback, two methods are considered. One is to use a compensating FIR filter. The other is to utilize uni-directional detecting microphone and uni-directional control speaker. Experimental results show that the reflections of sound from duct terminations greatly reduce the performance of ANC system. The directionality of detecting microphone and control speaker is a major factor to decide ANC performance. When there are some reflections from both duct terminations, the noise attenuation using finite FIR filter is not enough to model the duct plant. Especially, the reflection from the upstream termination reduces the noise attenuation in the frequencies related to the distance between control speaker and upstream termination. The performance of the noise attenuation is found to be largely enhanced by using uni-directional coupler, both on detecting microphone and control speaker, even if the duct system has an arbitrary termination conditions.

  • PDF

A generalized ANFIS controller for vibration mitigation of uncertain building structure

  • Javad Palizvan Zand;Javad Katebi;Saman Yaghmaei-Sabegh
    • Structural Engineering and Mechanics
    • /
    • 제87권3호
    • /
    • pp.231-242
    • /
    • 2023
  • A novel combinatorial type-2 adaptive neuro-fuzzy inference system (T2-ANFIS) and robust proportional integral derivative (PID) control framework for intelligent vibration mitigation of uncertain structural system is introduced. The fuzzy logic controllers (FLCs), are designed independently of the mathematical model of the system. The type-1 FLCs, have a limited ability to reduce the effect of uncertainty, due to their fuzzy sets with a crisp degree of membership. In real applications, the consequent part of the fuzzy rules is uncertain. The type-2 FLCs, are robust to the fuzzy rules and the process parameters due to the fuzzy degree of membership functions and footprint of uncertainty (FOU). The adaptivity of the proposed method is provided with the optimum tuning of the parameters using the neural network training algorithms. In our approach, the PID control force is obtained using the generalized type-2 neuro-fuzzy in such a way that the stability and robustness of the controller are guaranteed. The robust performance and stability of the presented framework are demonstrated in a numerical study for an eleven-story seismically-excited building structure combined with an active tuned mass damper (ATMD). The results indicate that the introduced type-2 neuro-fuzzy PID control scheme is effective to attenuate plant states in the presence of the structured and unstructured uncertainties, compared to the conventional, type-1 FLC, type-2 FLC, and type-1 neuro-fuzzy PID controllers.

구조물의 안전성 모니터링을 위한 통계/확률기반 적응형 임계치 설정 알고리즘 개발 (Development of Statistical/Probabilistic-Based Adaptive Thresholding Algorithm for Monitoring the Safety of the Structure)

  • 김태헌;박기태
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제20권4호
    • /
    • pp.1-8
    • /
    • 2016
  • 최근의 건축물은 복합적인 기능과 형태를 보이고 있으며, 크기가 거대해짐에 따라 구조물 건전성 감시(Structural Health Monitoring)기술의 수요 또한 증가하고 있다. 구조물마다 고유한 동특성을 가지고 있으며, 다양한 외력의 영향을 받기 때문에 구조물의 건전성을 평가하는 다양한 방법들이 연구되고 있다. 전문가에 의지하여 접근 가능한 지점에 대한 육안 검사 및 비파괴 검사를 벗어나 사각지대가 없는 온라인 계측 시스템의 구비와 함께 자동으로 위험요소를 검출하는 시스템이 요구되고 있다. 본 연구에서는 비선형적인 구조물의 응답을 고려하기 위해 관리도 기법, 평균제곱근편차, 일반 극치 분포 등과 같은 통계적 기법을 이용하여 이상거동을 판별에 활용할 수 있는 신호 특징 추출과 적응형 임계치 설정 알고리즘을 제안하였으며, 강제진동 실험과 실제 운용중에 있는 구조물의 지진 계측 시스템의 가속도 응답을 이용하여 성능을 검증하였다.

스마트 폼을 이용한 덕트 내부의 능동 소음 제어 (Active Noise Control in a Duct Using Smart Foam)

  • 김표재;강연준;조영만
    • 소음진동
    • /
    • 제11권3호
    • /
    • pp.422-427
    • /
    • 2001
  • In this paper is presented passive-active noise control in a duct using a ring-type smart foam. The ring-type smart foam is comprised of a PVDF film embedded in elastic noise control foam of lining shape. The embeddedPVDF element acts as an actuator to reduce noise at lower frequencies and the foam absorbs noise at higher frequencies. By implementing an adaptive filtered-x LMS algorithm, experiments are performed to reduce both tonal and broadband noise in a duct with one end closed and the other end open.

  • PDF

Optimization of Cancellation Path Model in Filtered-X LMS for Narrow Band Noise Suppression

  • Kim, Hyoun-Suk;Park, Youngjin
    • Transactions on Control, Automation and Systems Engineering
    • /
    • 제1권1호
    • /
    • pp.69-74
    • /
    • 1999
  • Adaptive algorithms based on gradient adaptation have been extensively investigated and successfully joined with active noise/vibration control applications. The Filtered-X LMS algorithm became one of the basic feedforward algorithms in such applications, but is not fully understood yet. Effects of cancellation path model on the Filtered-X LMS algorithm have investigated and some useful properties related to stability were discovered. Most of the results stated that the error in the cancellation path model is undesirable to the Filtered X LMS. However, we started convergence analysis of Filtered-X LMS based on the assumption that erroneous model does not always degrade its performance. In this paper, we present a way of optimizing the cancellation path modern in order to enhance the convergence speed by introducing intentional phase error. Carefully designed intentional phase error enhances the convergence speed of the Filtered X LMS algorithm for pure tone noise suppression application without any performance loss at steady state.

  • PDF

편로드 유압실린더의 운동제어를 위한 자기동조 제어기설계 (Self-Tuning Controller design for the motion control of a Single Rod Hydraulic Cylinder)

  • 김정태;김문생
    • 소음진동
    • /
    • 제8권3호
    • /
    • pp.441-449
    • /
    • 1998
  • A self-tuning control scheme, incorporated with the simplified 1st-order ARMAX(Auto-Regressive Moving Average eXogenous) model, for single rod hydraulic cylinder which has varying dynamic characteristics is presented here. An adaptive controller is developed for the system that uses feedforward and optimal feedback control for simultaneous parameter identification and tracking control. Through experimental results, the performance comparison of the self-tuning controller with a fixed gain proportional controller clearly shows its superior ability in handling load changes in quiescent states.

  • PDF

구동기의 성능 한계를 고려한 구조물의 진동제어 알고리듬의 적용에 관한 연구 (A Study on the Applicability of Structural Vibration Control Algorithm Considering the Performance Limit of Actuator)

  • 임채욱;정태영;문석준;김광준
    • 한국지진공학회논문집
    • /
    • 제4권2호
    • /
    • pp.25-36
    • /
    • 2000
  • 본 논문에서는 구조물이 과도한 기진력을 받을 때에 구조물의 진동 제어를 위하여 제안 되어진 여러 가지 포화 제어 알고리듬들의 유용성을 실제적인 관점에서 살펴보았다 제안된 포화 제어 알고리듬 중세서 수정된 뱅뱅 제어 알고리듬이 매우 유용한 것임을 확인할 수 있었으나 이는 제어력 파형 결정 파라미터의 어떤 범위내에서만 효과적이며 그 범위를 넘어서는 경우에 있어서는 제어기를 불안정하게 할 수 있음을 확인할 수 있었다 따라서 수정된 뱅뱅 제어 알고리듬의 적용시에 과도한 외부 기진력에 대하여 제어기의 안정적인 작동에 의한 구조물의 진동제어효과를 얻기 위해서 제어력 파형 파라미터를 과도 기진력의 크기에 따라 변화시키는 적응형의 방법을 제안하였고 이의 유용성을 수치실험 및 유압식 질량 감쇠기를 장착한 축소 구조물 검증 실험을 통하여 확인하였다.

  • PDF

Adaptive length SMA pendulum smart tuned mass damper performance in the presence of real time primary system stiffness change

  • Contreras, Michael T.;Pasala, Dharma Theja Reddy;Nagarajaiah, Satish
    • Smart Structures and Systems
    • /
    • 제13권2호
    • /
    • pp.219-233
    • /
    • 2014
  • In a companion paper, Pasala and Nagarajaiah analytically and experimentally validate the Adaptive Length Pendulum Smart Tuned Mass Damper (ALP-STMD) on a primary structure (2 story steel structure) whose frequencies are time invariant (Pasala and Nagarajaiah 2012). In this paper, the ALP-STMD effectiveness on a primary structure whose frequencies are time varying is studied experimentally. This study experimentally validates the ability of an ALP-STMD to adequately control a structural system in the presence of real time changes in primary stiffness that are detected by a real time observer based system identification. The experiments implement the newly developed Adaptive Length Pendulum Smart Tuned Mass Damper (ALP-STMD) which was first introduced and developed by Nagarajaiah (2009), Nagarajaiah and Pasala (2010) and Nagarajaiah et al. (2010). The ALP-STMD employs a mass pendulum of variable length which can be tuned in real time to the parameters of the system using sensor feedback. The tuning action is made possible by applying a current to a shape memory alloy wire changing the effective length that supports the damper mass assembly in real time. Once a stiffness change in the structural system is detected by an open loop observer, the ALP-STMD is re-tuned to the modified system parameters which successfully reduce the response of the primary system. Significant performance improvement is illustrated for the stiffness modified system, which undergoes the re-tuning adaptation, when compared to the stiffness modified system without adaptive re-tuning.

두 정현파 소음에 대한 Filtered-X LMS 알고리즘의 특성연구 (Characteristics of Filtered-X LMS Algorith for Two Tone Noise)

  • 김현석;박영진
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1994년도 춘계학술대회논문집; 영남대학교, 20 May 1994
    • /
    • pp.16-21
    • /
    • 1994
  • For the systems such as ANC(Active Noise Control) systems having auxiliary path after FIR type adaptive filter, Filtered-X LMS algorithm is effective. However behaviors of this algorithm has not been fully understood. The convergence property of this algorithm depends on not only cross correlation matrix between the filtered signals through model and real auxiliary path state solution of weight vector in Filtered-X LMS algorithm is investigated for under-determined case, over-determined case, and nonsingular case. Also, the convergence speed in case of two tone noise is investigated based on the eigenvalue spread of cross correlation matrix.