• Title/Summary/Keyword: Actual test

Search Result 3,541, Processing Time 0.029 seconds

Study on Research for the Safety Education in Kindergarten (유치원 안전교육에 관한 조사 연구)

  • Park, Yong-Keel
    • Korean Journal of Human Ecology
    • /
    • v.12 no.5
    • /
    • pp.619-634
    • /
    • 2003
  • The purpose of this study was to the real situation of the safety education in the kindergarten by investigating the actual condition of the safety education and kindergarten teachers' knowledge about it. Questionnaire was adopted to obtain data required for pertinent analysis. The subjects were 234 kindergarten teachers located in Choongnam and Daejeon province. SPSSWIN v10.0 was utilized to calculate percentage, mean and standard deviation and to conduct t-test, one-way ANOVA and Duncan's multiple range test. The main results of this study were as follows. There was a significant difference between the actual condition of the safety education and kindergarten teachers' knowledge about it according to demographic variables. Especially, these differences were due to teachers' academic career, age, teaching experience, and the experience of bringing up children by themselves. The importance of the safety education must be emphasized. There were urgent needs to develop the way of teaching and the program about the safety education.

  • PDF

Test and traction characteristic of Electric Locomotives (전기기관차 견인특성 및 시험)

  • Jeon, Hun-Jong;Kim, Chul-Ho;Lim, Jae-Hyung
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1550-1557
    • /
    • 2007
  • New locomotives 8100 & series 8200, based on the BR152 of German railway are suitable for heavy-duty freight traffic as well as for passenger transport. This electric locomotive had applied by trial petition way and 57 car is operating in mainline and industrial line until now. As matter of fact, this has a purpose to help designing and manufacturing the new electric locomotive in these day when almost all the line is changing into the electric fire line. This thesis has a purpose to check whether the actual simulation value properly apply and meet the designing value, comparing the result of the simulation for the performance of developed locomotive with the result of the type test which can be proceed in actual locomotive in korea (evaluating both the design value and the performance of the real locomotive).

  • PDF

A Study on Weldability Criteria of Mash Seam Tailored Blank Welds in the Ultra-low Carbon Steel Applied on Automotive Body (극저탄소강의 Mash Seam TB 용접성 평가에 관한 연구)

  • 한창우;이창희;이명호
    • Journal of Welding and Joining
    • /
    • v.20 no.4
    • /
    • pp.538-543
    • /
    • 2002
  • M/S TB(Mash Seam Tailored Blank) is a production method for blanks by welding together blanks of different material, thickness and coating, and is an attractive method for manufacturing car body because it makes parts lighter and can save the cost and time to manufacture. However, there have not been quantified criteria to evaluate the quality of TB weld. This study introduced FHR (failure height ratio) in order to assess formability or/and weldability of the M/S welds and the applicability of FHR was confirmed by actual auto body forming and FLD tests. Furthermore, a new parameter, HN(heat number) based on the heat input of "$Q=I^2Rt$" was proposed and assessed. It was found that the concept of HN could be utilized to evaluate the soundness of M/S welds without any destructive tests.ive tests.

Transferred OverVoltages on LV sides in Multigrounded Neutral during Line to Ground Fault on Distribution Systems (배전계통의 고저압 혼촉고장시 중성선 전위상승에 따른 저압기기 스트레스 전압)

  • Choi, Sun-Kyu;Choi, Jong-Kee;Kim, Kyoung-Hun;Choi, Myeong-Ho;Lee, Byung-Sung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.6
    • /
    • pp.910-915
    • /
    • 2012
  • In this paper we propose multi-grounded neutral design method which was considered of transferred transient overvoltage when line to neutral fault occurs. Specially, In order to confirm the actual transient overvoltage magnitude which occurs on neutral line, we considered some screening(shielding) effects. The screening coefficient was deducted from field test results and calculation in a distribution line which is identical with an actual power line. The purpose of this paper is to attempt to suggest the guidance for grounding skystem design considering limitation of overvoltage for LV side in IEC 61936. The result is based on EMTP simulation and real field faults situation in distribution lines.

An Experimental Study on the Failure Characteristics of Flip Chips in Cyclic Bending Test (플립칩의 반복 굽힘 시험 시 파손 특성에 관한 실험적 연구)

  • Lee, Yong-Sung;Jeong, Jong-Seol;Kim, Hong-Seok;Shin, Ki-Hoon
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.18 no.4
    • /
    • pp.362-368
    • /
    • 2009
  • In general, circuit board assemblies experience various mechanical loadings during assembly and in actual use. The repeated cyclic bending can cause electrical failures due to circuit board cracks, solder interconnects cracks, and the component cracks. In this paper, we report on the failure characteristics of semiconductor chips under the repeated cyclic bending. We first describe a new 4-point bending tester, which is developed according to JEDEC standard No. 22B113. The performance of the tester is then estimated through actual experiments. Test results reveal that the cracks first occur on the outer balls around 20,000 cycles and gradually propagate to the inner balls where cracks are found around 70,000 cycles.

  • PDF

A Study on Adoption of Alternative Cost-effectiveness Analysis Method for the DSM Investment Program and Actual Application (수요관리 투자사업에 대한 대안적 비용효과 분석 기법 도입 및 실제 적용)

  • Choi, Bong-Ha;Park, Su-Uk;Lee, Jeong-Tae;Lee, Chan-Seob
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.243-248
    • /
    • 2008
  • The purpose of this study is to introduce alternative cost-effectiveness analysis method of DSM investment programs. This alternative method is Value Test method which consider the effects of DSM investment program on customer value. And this method was applied for actual DSM investment program in natural gas domain. By utilize this method to evaluate cost-effectiveness of DSM investment programs, it is expected to make right decision to enforce and complement those programs.

  • PDF

Measurements of Erosion Rate in Fine-Grained Soils (세립토의 침식율 측정)

  • 곽기석;정문경;정하익;우제윤;조삼덕
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.337-342
    • /
    • 2002
  • A new apparatus called the EFA (Erosion Function Apparatus) has been built and tested to measure the erodibility of fine-grained soils. The EFA is a simple test to predict the erosion rate of fine-grained soils along with the corresponding velocity and shear stress. In addition, it is advantageous in predicting the scour rate for actual soil samples from bridge sites. The plot of erosion rate versus shear stress is the result of an EFA test. It Indicates the critical shear stress at which erosion starts and the rate of erosion beyond that shear stress. In order to measure the erodibilities of various soils, 14 Shelby Tube soil samples are collected from the actual bridge sites and tested using the EFA. The results of the EFA tests which are the relationships between erosion rates and shear stresses are presented in this paper and research continues to develop the correlation between the erosion function and the soil properties.

  • PDF

A Study on Energy Characteristics in Transient States of OF Cable Systems (OF 케이블 계통에서 과도상태시 에너지 특성 검토)

  • Jung, Chae-Kyun;Lee, Jong-Beom;Kang, Ji-Won;Lee, Dong-Il;Seo, Je-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.11
    • /
    • pp.468-475
    • /
    • 2006
  • This paper reviews the energy characteristics of oil filled cables in transient state such as grounding fault and lightning surge. Artificial grounding fault test was firstly performed in 2003 for the analysis of arc voltage and breakdown energy according to the fault current. In this paper, energy of OF cable is variously analysed at joint box based on the actual test. Then more various conditions such as installation types, section lengths and CCPU(Cable Covering Protection Unit) connection types are applied for the simulation using EMTP when the single line to ground fault and direct lightning stroke are occurred on actual underground power cable systems and combined power cable systems, respectively. Finally, the energy by the length of crossbonded lead and grounding lead as well as fault lasting time is also calculated using EMTP simulation.

Power Quality Analysis and Failure of Earth Leakage Breakers in Plant (공장전기설비에서의 누전차단기 오동작과 전력품질 분석)

  • Lee, S.J.;Yoo, J.G.;Jeon, J.C.;Jeon, H.J.;Heo, H.S.;Choe, G.H.
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.479-481
    • /
    • 2007
  • This paper presented a actual conditions on a false-tripping of ELB(Earth Leakage Breakers) and an assessment of the harmonics due to non-linear electronic equipment such as personal computers, rectifier, electric furnace and test equipments in plant installations. Actual conditions on a failure of ELB were surveyed and analyzed by making up a question to safety managers of plant installations. Also, power quality measurements such as harmonic currents, voltage and current waveform and current imbalance were made at various plant installations where nuisance tripping of ELB is often occurred. The results of this study can be used in making decisions regarding cause of ELB trip and operating and tripping characteristics test of ELB when subjected to distorted current waveform.

  • PDF

Analysis of Improvement Effects for Flight Training Quality (비행훈련 품질 향상을 위한 개선 효과 분석)

  • Kang, Dal Won
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.28 no.4
    • /
    • pp.82-88
    • /
    • 2020
  • Currently, flight training is not only a technical instruction that teaches maneuvering operations, but has expertise equal to that of general disciplines. Therefore, flight instructors must have academic knowledge and flight skills. As flight instructors are the first teacher in flight training for students who have never experienced actual flight control, the behavior of flight instructors will affect the students' flight education. Therefore, the influence of flight instructors for students are quite large compared to other educational institutions. In this study, the factors of instructional behavior were determined, and the actual state of instructional behavior of flight instructors were confirmed through students' survey. Improvements were derived to solve the problems identified in the survey results. For the follow-up analysis, improvements were applied to the flight instructors for 8 months, and then re-question was conducted to the same students who responded to the first questionnaire to find out the difference in results before and after through a paired t-test.