A Study on the Measurement and the Analysis of Radar Cross Section of the Scaled Aircraft Model (축소형 항공기 모델의 레이다 단면적 분석 및 측정에 대한 연구)

  • Kim, Ki-Jung
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.6
    • /
    • pp.1055-1060
    • /
    • 2020
  • This study is a study on the analysis and measurement of the radar cross-sectional area of a miniature aircraft. Radar cross-sectional area for miniature aircraft in advance were analyzed using an electromagnetic analysis tool, and an actual miniature aircraft was manufactured and measured in an anechoic chamber. When measuring, the old model was used as reference data for RCS(radar cross section) characteristics and applied to the test result data of the actual reduced model. The measurement method improved the accuracy of the measurement by applying time gating to remove the influence on the components scattered inside the anechoic chamber. The RCS test results of the reduced model showed relatively high RCS characteristics in the microwave band, as the previous analysis results. In the future, we plan to utilize the method of RCS analysis and measurement for the target of the radar in the VHF(Very High Frequency)/UHF(Ultra High Frequency) band with a relatively large wavelength.

A Study on the Measurement Accuracy and Linearity of the Mandibular Kinesiograph (Mandibular Kinesiograph의 선형충실도 및 계측정확도에 관한 연구)

  • Kim, In-Kwon
    • The Journal of the Korean dental association
    • /
    • v.22 no.7 s.182
    • /
    • pp.607-620
    • /
    • 1984
  • The validity of the Kinesiegraph (MHG-5R) output was studied using a non-ferromagnetic positioning device within working range of a 3 cm wide by 4 cm deep by 5 cm high three dimensional lattice. To determine how well observed values of the M K G outputs may predict case values of actual measurements, relationships between those values were tested by viewing scatter plots and correlation between observed values and actual values. In order to devise some form of served values of the M k G outputs (volts), statistical regression analysis was performed. The statistical analysis showed that observed values and actual values were strongly correlated. However, high correlation does not necessarily mean perfect predictability of given linear models. The formulated models were not able to predict all of acutal values this is partly 엳 새the discreteness of dependent variables (actual values) and also is because of independent nature of observed values. In conclusion, unless the Kinesiograph is suitably modified, the inherent nonlinearity characteristic of the system output limits its application to the measurement of a limited range of jaw movements.

  • PDF

A New Perspective on the Advanced Microblade Cutting Method for Reliable Adhesion Measurement of Composite Electrodes

  • Song, Jihun;Shin, Dong Ok;Byun, Seoungwoo;Roh, Youngjoon;Bak, Cheol;Song, Juhye;Choi, Jaecheol;Lee, Hongkyung;Kwon, Tae-Soon;Lee, Young-Gi;Ryou, Myung-Hyun;Lee, Yong Min
    • Journal of Electrochemical Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.227-236
    • /
    • 2022
  • The microblade cutting method, so-called SAICAS, is widely used to quantify the adhesion of battery composite electrodes at different depths. However, as the electrode thickness or loading increases, the reliability of adhesion values measured by the conventional method is being called into question more frequently. Thus, herein, a few underestimated parameters, such as friction, deformation energy, side-area effect, and actual peeing area, are carefully revisited with ultrathick composite electrodes of 135 ㎛ (6 mAh cm-2). Among them, the existence of side areas and the change in actual peeling area are found to have a significant influence on measured horizontal forces. Thus, especially for ultrahigh electrodes, we can devise a new SAICAS measurement standard: 1) the side-area should be precut and 2) the same actual peeling area must be secured for obtaining reliable adhesion at different depths. This guideline will practically help design more robust composite electrodes for high-energy-density batteries.

A Study on the Standard Method of Measurement Information Communication Field Contractors (정보통신시설공사 수량산출기준에 관한 연구)

  • Seol, Dong-Hwa;Lee, Kwang-Hee
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.2 no.4
    • /
    • pp.52-63
    • /
    • 2003
  • This study proposes a change from the currentexpected price integrated system, which is based on the standard of estimated unit manpower and material, to a new actual construction cost integrated system. In order to implement it, the standard method of measurement organization system as well as the communication area standard of estimated unit manpower and material should be changed Moreover, the work breakdown structure and itemized structure should be assorted.

  • PDF

Silicon-Based Integrated Inductors for Wireless Applications

  • Kim, Bruce C.
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.10a
    • /
    • pp.389-393
    • /
    • 2003
  • This paper presents circuit modeling and characterization of silicon-based on-chip integrated inductors in Giga Hertz range for wireless communication products. We compare several different designs of on-chip inductors for self-resonant frequency and quality factor. The measurement data could be used as a design guide for manufacturing practical spiral inductors for wireless applications. We provide the equivalent inductor circuit parameters from the actual measurement data.

  • PDF

Derivation of Consideration Factors for Fine Dust Measurement through GIS Mapping (단지조성공사의 미세먼지 측정 및 GIS Mapping을 통한 미세먼지 측정 고려요소 도출)

  • Kim, Young Hyun;Han, Jae Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.163-164
    • /
    • 2020
  • When measuring fine dust at a large-scale site such as complex construction, the change in the value of fine dust measurement is large due to the influence of the time, location, wind speed, wind direction, and humidity. This study aims to find out the results of measuring fine dust in an actual construction site and inferring the changes.

  • PDF

Development of Wall-Thinning Evaluation Procedure for Nuclear Power Plant Piping-Part 1: Quantification of Thickness Measurement Deviation

  • Yun, Hun;Moon, Seung-Jae;Oh, Young-Jin
    • Nuclear Engineering and Technology
    • /
    • v.48 no.3
    • /
    • pp.820-830
    • /
    • 2016
  • Pipe wall thinning by flow-accelerated corrosion and various types of erosion is a significant and costly damage phenomenon in secondary piping systems of nuclear power plants (NPPs). Most NPPs have management programs to ensure pipe integrity due to wall thinning that includes periodic measurements for pipe wall thicknesses using nondestructive evaluation techniques. Numerous measurements using ultrasonic tests (UTs; one of the nondestructive evaluation technologies) have been performed during scheduled outages in NPPs. Using the thickness measurement data, wall thinning rates of each component are determined conservatively according to several evaluation methods developed by the United States Electric Power Research Institute. However, little is known about the conservativeness or reliability of the evaluation methods because of a lack of understanding of the measurement error. In this study, quantitative models for UT thickness measurement deviations of nuclear pipes and fittings were developed as the first step for establishing an optimized thinning evaluation procedure considering measurement error. In order to understand the characteristics of UT thickness measurement errors of nuclear pipes and fittings, round robin test results, which were obtained by previous researchers under laboratory conditions, were analyzed. Then, based on a large dataset of actual plant data from four NPPs, a quantitative model for UT thickness measurement deviation is proposed for plant conditions.

Development and Evaluation of High Speed weigh-in-motion system (고속축하중측정시스템의 개발과 평가)

  • Kim, Ju-Hyun
    • International Journal of Highway Engineering
    • /
    • v.12 no.3
    • /
    • pp.17-26
    • /
    • 2010
  • Maintenance of the roads and bridges is a major issue for all road administrators around the world, and various initiatives are being implemented in each region for the purpose of controlling the ever increasing road maintenance cost while ensuring the safety of the vehicles driving. Efforts for such initiatives have also been made in Asia and initiatives for managing heavy-weight vehicles have recently gained momentum in Korea and Japan. We have developed a technology for unevenly installing bar-shaped sensors (piezo quartz sensors) to enable dynamic axle load measurement at a highly accurate level, and have estimated our measurement accuracy of axle load/gross weight, etc. on an actual road. The measurement accuracy of the axle load/gross weight varies significantly depending on the number of sensors installed. In our implementation, the target accuracy was set to below ${\pm}5%$ for gross weight measurement so that automatic regulation can be applied. We have achieved our target by installing 8-point measurement system. However, to have this technology widely accepted, it was necessary to reduce the system size so that it can be easily implemented. Therefore, we have estimated the relationship between the measurement accuracy and the system size (number of measurement points), and have come up with the proposal of 3-point measurement as an optimum number of measurement points, and have estimated its performance on an actual road. Additionally, we evaluated the relationship between the measurement accuracy and vehicle velocity.

PIV Measurement on the Flows of PDP(Plasma Display Panel) (PDP 유동장 PIV 계측)

  • Doh, D.H.;Cho, G.R.;Pyun, Y.B.;Song, J.S.;Baek, T.S.;Jung, W.M.
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.733-737
    • /
    • 2001
  • Heat generated from the electronic parts in PDP is undesirable physical properties. To attain optimal arrangement of the electronic parts in PDP, thermal flows in PDP should be analyzed. PIV measurement has been made to quantify the characteristics of the inner flows and outer flows of an actual PDP. The quantity of heat flux from PDP has been estimated using the PIV results. Measurement system consists of Ar-ion laser, CCD camera and an image grabber installed on a host computer.

  • PDF

Leak Evaluation for Power Plant Valve Using Multi-Measuring Method

  • Lee, Sang-Guk;Park, Jong-Hyuck;Kim, Young-Bum
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.6
    • /
    • pp.469-476
    • /
    • 2008
  • Condition based maintenance(CBM) for the preventive diagnosis of important equipments related to safety or accident in power plant is essential by using the suitable methods based on actual power plant conditions. To improve the reliability and accuracy of the measured value at the minute leak situation, and also to monitor continuously internal leak condition of power plant valve, the development of a diagnosis and monitoring technique using multi-measuring method should be performed urgently. This study was conducted to estimate the feasibility of multi-measuring method using three different methods such as acoustic emission(AE) method, thermal image measurement and temperature difference$({\Delta}T)$ measurement that are applicable to internal leak diagnosis for the power plant valve. From the experimental results, it was suggested that the multi-measuring method could be an effective way to precisely diagnose and evaluate internal leak situation of valve.