• Title/Summary/Keyword: Actual Measurement

Search Result 1,774, Processing Time 0.033 seconds

Visualization of the flow between co-rotating disks in shroud with an obstruction (장애물을 포함한 동시회전 디스크 내부의 비정상 유동가시화)

  • 공대위;도덕희;주원구
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.1152-1156
    • /
    • 2003
  • Hard disk drives (HDD) in computer are used extensively as data storage capacity. The trend in the computer industry to produce smaller disk drives rotating at higher speeds requires an improved understanding of fluid motion in the space between disks. PIV measurement was used fer the unsteady flow between the center pair of four disks of four times larger than common radius of HDD disk at several rpm in a fixed cylindrical enclosure. The boundary between inner region and outer region is detected using PIV measurement and the number of dominant vortices s determined clearly. Tip vortices generated by an obstruction with actual-like configuration can be found at inner region. Oscillating flow from the obstruction appears at outer region with complex flow pattern.

  • PDF

A Study on the Temperature Measurement at the Disk Brake of a High-Speed Rail Transit by the Non-Contact Method (비접촉 방법에 의한 고속철도 디스크 브레이크에서의 온도측정에 관한 연구)

  • 이광재;전필수;유재석;이종화;최강윤;김석원
    • Proceedings of the KSR Conference
    • /
    • 2002.10b
    • /
    • pp.820-825
    • /
    • 2002
  • As the speed of rail transit is higher, it is very important to secure the safety and confidence of the braking device and in the point of view, by means of the rise of the temperature from the friction between the disk and pad which are the actual part of a braking system, the damage of brake disk is the main cause to lose the safety of braking device. Therefore, in this study, to predict the danger of a disk brake and to know its max. temperature in the train service the module of a temperature measurement by the non-contact method was developed.

  • PDF

Performance Improvement of Wald Test for Resolving GPS Integer Ambiguity Using a Baseline-Length Constraint

  • Lee Eun-Sung;Chun Se-Bum;Lee Young-Jae;Kang Tea-Sam;Jee Gyu-In;Abdel-Hafez Mamoun F.
    • International Journal of Control, Automation, and Systems
    • /
    • v.4 no.3
    • /
    • pp.333-343
    • /
    • 2006
  • In this paper, the baseline-length information is directly modeled as a measurement for the Wald test, which speeds up the resolution convergence of the integer ambiguity of GPS carrier phase measurements. The convergent speed improvement is demonstrated using numerical simulation and real experiments. It is also shown that the integer ambiguities can be resolved using only four actual satellite measurements with very reasonable convergence speed, if the baseline-length information is used just like one additional observable satellite measurement. Finally, it is shown that the improvement of convergence speed of the Wald test is due to the increase of the probability ratio with the use of the baseline-length constraint.

Improved Yaw-angle Estimation Filter as a Function of the Actual Maneuvers for a Cleaning Robot (주행조건 식별을 이용한 로봇청소기의 진행각 추정을 위한 향상된 필터설계)

  • Cho, Yoon Hee;Lee, Sang Cheol;Hong, Sung Kyung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.6
    • /
    • pp.470-476
    • /
    • 2016
  • This paper proposes a practical algorithm for the reduction of measurement errors due to drift in a micro-electromechanical system (MEMS) gyros that are used for a mobile robot. Any drift in a MEMS gyro will cause an unbounded growth of errors in the estimation of heading, which makes it nearly useless in applications that require high accuracy over a long operating time. In proposed method, maneuvers of a cleaning robot are observed through encoders' measurement process and a decision to correct bias drift will be made if necessary. The method used in this paper is called the "heading estimation filter". To evaluate the accuracy of the proposed method, a comparison was made between the estimation of the heading of the cleaning robot and one from a motion capture system.

Battery State-of-Charge Estimation Algorithm Using Dynamic Terminal Voltage Measurement

  • Lee, Su-Hyeok;Lee, Seong-Won
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.4 no.2
    • /
    • pp.126-131
    • /
    • 2015
  • When a battery is discharging, the battery's current and terminal voltage must both be measured to estimate its state of charge (SOC). If the SOC can be estimated by using only the current or voltage, hardware costs will decrease. This paper proposes an SOC estimation algorithm that needs to measure only the terminal voltage while a battery is discharging. The battery's SOC can be deduced from its open circuit voltage (OCV) through the relationship between SOC and OCV. But when the battery is discharging, it is not possible to measure the OCV due to the voltage drop in the battery's internal resistance (IRdrop). The proposed algorithm calculates OCV by estimating IRdrop using a dynamic terminal voltage measurement. This paper confirms the results of applying the algorithm in a hardware environment via algorithm binarization. To evaluate the algorithm, a Simulink battery model based on actual values was used.

Studies on the Biodegradation Test Method of Sufactant (계면활성제 생분해도 측정방법에 관한 연구)

  • 김영환;정해권김은기윤태일
    • KSBB Journal
    • /
    • v.8 no.4
    • /
    • pp.364-369
    • /
    • 1993
  • The biodegradability of some anionic surfactants were investigated using biological oxygen consumption measurement at different temperatures. As test surfactants, soap, alkyl sulfate (AS), alpha olefin sulfonate (AOS), alkyl polyoxyethylene sulfate (AES), linear alkylbezene sulfonate(LAS), microbial surfactants such as sophorose lipid (sopholipid) and spiculisporic acid (S-acid), were used. The test solution were incubated at $5^{\circ}C$, $18^{\circ}C$ and $32^{\circ}C$, respectively. The comparative rates of biodegradation were in accordance with the results obtained from the surface tension measurement and methylene blue method. The results of comparative blodegradabilities of the surfactants were as follows; soap, AS>AES>AOS>LAS at $18^{\circ}C$ and $32^{\circ}C$. However, at$ 5^{\circ}C$, the biodegradation rate of soap was better than other surfactants. Considering the actual environment of the river, it was concluded that the biological oxygen consumption rate method at lower temperature was more practical than the current method such as methylene blue assay with adapted shaking flask culture at $25^{\circ}C$

  • PDF

Field measurement of damping in industrial chimneys and towers

  • Cho, K.P.;Tamura, Y.;Itoh, T.;Narikawa, M.;Uchikawa, Y.;Nishimura, I.;Ohshima, Y.
    • Structural Engineering and Mechanics
    • /
    • v.12 no.4
    • /
    • pp.449-457
    • /
    • 2001
  • In the design of industrial chimneys and towers, structural engineers must assume a level of the inherent damping in the structures. In order to better estimate the dynamic response of those structures, actual damping was measured from wind-induced vibration signals of chimneys and towers and its characteristics with respect to the response levels, the structural systems, and the wind direction were discussed. Damping ratio and natural frequency for three chimneys and two towers were calculated using random decrement technique.

A new contrast ratio measurement method using image patterns

  • Choi, Dong-Wook;Yang, Sun-A;Bae, Jae-Woo;Lee, Seung-Bae;Chung, Ho-Kyoon
    • Journal of Information Display
    • /
    • v.12 no.2
    • /
    • pp.85-87
    • /
    • 2011
  • The contrast ratio is one of the most important performance parameters for display devices. The general method of measuring the contrast ratio is to determine the ratio of the full-screen white pattern to the full-screen black pattern, according to the Video Electronics Standards Association standard. Real TV images seldom have these images, however, and the conventional method does not reflect the true performance of the display in actual use. In this paper, a new contrast ratio measurement method that uses image patterns is proposed, to demonstrate that active matrix organic light-emitting diode TVs have a higher contrast than LED (LCD) TVs.

A Feasibility Study on a Subsurface-Penetrating Radar for Nondestructive Testing of Wooden Architectures : FDTD Simulation and Laboratory Measurement (목조 건축물의 비파괴 검사를 위한 표면하부 탐사 레이더의 적용 가능성 검토 : FDTD 모의계산과 실험 측정)

  • 현승엽;김세윤
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.8
    • /
    • pp.790-796
    • /
    • 2002
  • In our country, historically beautiful and significant wooden architectures are preserved as the cultural properties. For a long time, however, the architectures are often exposed to rough environmental conditions, such as weathering, insect attack, etc. This may lead to deterioration of structural integrity of the architectures. Therefore, it is necessary to diagnose wooden architectures in advance. In this paper, the possibility of a subsurface-penetrating radar(SPR) fur non-destructive testing(NDT) of wooden architectures is investigated by using the three-dimensional finite-difference time-domain(FDTD) simulation and actual laboratory measurement.

A HIGH PRECISION CAMERA OPERATING PARAMETER MEASUREMENT SYSTEM AND ITS APPLICATION TO IMAGE MOTION INFERRING

  • Wentao-Zheng;Yoshiaki-Shishikui;Yasuaki-Kanatsugu;Yutaka-Tanaka
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 1999.06a
    • /
    • pp.77-82
    • /
    • 1999
  • Information about camera operating such as zoom, focus, pan, tilt and tracking is useful not only for efficient video coding, but also for content-based video representation. A camera operating parameter measurement system designed specifically for these applications is therefore developed. This system, implemented in real time and synchronized with the video signal, measures the precise camera operating parameters. We calibrated the camera lens using a camera model that accounts for redial lens distortion. The system is then applied to infer image motion from pan and tilt operating parameters. The experimental results show that the inferred motion coincides with the actual motion very well, with an error of less than 0.5 pixel even for large motion up to 80 pixels.