• 제목/요약/키워드: Actual Measurement

검색결과 1,774건 처리시간 0.028초

무인항공기를 활용한 가설구조물의 길이와 기울기 측정에 관한 연구 (A Study on Measurement of Length and Slope of Temporary Structure using UAV)

  • 강민국;신승현;박종근;원정훈
    • 한국안전학회지
    • /
    • 제37권6호
    • /
    • pp.89-95
    • /
    • 2022
  • A method for measuring the length and slope of a temporary structure using an unmanned aerial vehicle (UAV) and 3D modeling method is proposed. The actual length and slope of the vertical member of the specimen were measured and compared with the measured values obtained by the proposed method for the specimens with and without the vertical protection net installed. Based on the result of measuring the length of the temporary structure specimen using the UAV and 3D modeling method, the measured value showed an error of 0.87% when compared to the actual length in the specimen without the vertical protection net installed. In addition, the error of the slope was 0.63°. It was thought that the proposed method could be usable for the purpose of finding parts in wrong installation state on the temporary structure and informing the manager in charge. However, in the case of the specimen with the vertical protection net, the measurement showed a 1.46% error in length and 2.77° difference in slope. Therefore, if a vertical protection net is to be installed in a temporary structure, the measurement accuracy should be improved by utilizing an image processing method, etc.

간호전문대학생들의 임상실습현장에서의 수행에 관한 연구 -실습의 내용 빈도를 중심으로- (A Study of the Junior Nursing College Students실 Role during Clinical Practice)

  • 권경남
    • 대한간호학회지
    • /
    • 제13권3호
    • /
    • pp.1-33
    • /
    • 1983
  • The role and function of nursing care nowadays, tend to acquire sophisicated technology because specialization has expended due to increase of the medical population and the improvement of national health standards. To implement nursing care independently as a professional nurse, the apprehension of specific knowledge and skill should be acquired during basic nursing education. So it is important for nursing education not only to include theory and actual techniques, but also to strengthen the practical training in the actual clinical setting. This study was carried out with the following objectives; 1. To survey the detailed content and frequency of actual nursing students display during their clinical training. 2. To investigate the detailed content and frequency of actual nursing behavior which students display in each clinical a area. 3. To identify the motive for selection of nursing as their major and to determine the degree of self confidence, extent of knowledge and recognition of nursing responsibility. 4. To observe the relationship between actual nursing behavior and each of the following; 1) Motive for selecting nursing as a major 2) Self confidence 3) Knowledge of nursing care 4) Recognition of nursing responsibility The conclusions of this study were as follows; 1. Among the detailed nursing behavior which junior nursing college students carry out in clinical training; taking respiration's showed the highest frequency, and taking body temperatures, blood pressures, and pulses and making beds were next in frequency in this order. 2. In detailed nursing behaviors according to clinical area; taking vital signs showed the highest frequency in the emergency room, pediatric ward, orthopedic ward, general surgical ward and internal medicine ward. However, in the operating room, assisting with endotracheal tube insertion and sterile techniques were showen to have the highest frequencies. In nursery, umbilical cord care and the measurement of body weight were the highest in frequency In neurosurgical ward, the measurement of vital signs, changing position and tracheostomy care were the highest in frequency. In obstetric and gynecological ward and in the delivery room, checking duration, intensity and frequency of contractions was the highest in frequency. 3. In regard to the motive for majoring in nursing, the aptitude and interest of the student had the highest percentage(32.86%), and self-confidence in nursing activities (M=3.36), knowledge in nursing activities.(M=3. 09), and the recognition of the nursing activity (M= 3.76) wire in the middle range. 4. When the detailed nursing behaviors were compared with motive, self confidence, knowledge and recognition, it was found that when the nursing behavior was difficult and regarding much endeavor although the motive was high, the frequency of the nursing behavior was rather low. But in the cases in which there was much self confidence and a high level of skill was required, nursing behavior was carried more frequently. When there was muck self confidence and skill was not required, the frequency of nursing behavior was rather low. In the cases of a high level of knowledge, the frequency of nursing behavior was low and when recognition for nursing behavior was given the frequency of nursing behavior was low.

  • PDF

근광장 측정에서 방사선 사진술의 정확도 (The Accuracy of the Radiographic Method in Root Canal Length Measurement)

  • 조은영;박창서
    • 치과방사선
    • /
    • 제28권2호
    • /
    • pp.471-489
    • /
    • 1998
  • For the successful endodontic treatment, root canal should be cleaned thoroughly by accurate mechanical and chemical canal preparation and sealed completely with canal filling material without damaging the periapical tissues. The accuracy of the root canal length measurement is a prerequisite for the success of the endodontic treatment, and the root canal length is often determined by the standard periapical radiographs and digital tactile sense. In this study, the accuracy and the clinical usefulness of Digora/sup (R)/, an intraoral digital imaging processor and the conventional standard radiographs were compared by measuring the length from the top of the file to the root apex. 30 single rooted premolars were invested in a uniformly sized blocks and No.25 K-file was inserted into and fixed in each canal. Each block was placed in equal distance and position to satisfy the principle of the bisecting angle and paralleling techniques and Digora/sup (R)/ system's image and standard periapical radiographs were taken. Each radiograph was examined by 3 different observers by measuring the length from top of the file to the root apex and each data was compared and analyzed. The results were as follows; 1. In the bisecting angle technique, the average difference between the Digora/sup (R)/ system and standard periapical radiograph was 0.002 mm and the standard deviation was 0.341 mm which showed no statistically significant difference between the two systems(p>0.05). Also, in the paralleling technique, the average difference between these two system was 0.007 mm and the standard deviation was 0.323 mm which showed no statistically significant difference between the two systems(p>0.05). 2. In Digora/sup (R)/ system, the average difference between the bisecting angle and paralleling technique was -0.336 mm and the standard deviation was 0.472 mm which showed a statistically significant difference between the two techniques(p<0.05). Also, in the standard periapical radiographs, the average difference between the bisecting angle and paralleling technique was 0.328 mm and the standard deviation was 0.517 mm which showed a statistically significant difference between these two techniques(p<0.05). 3. In Digora/sup (R)/ system and the standard periapical radiographs. there was a statistically significant difference between the measurement using the bisecting angle technique and the actual length(p<0.05), But there was no statistically significant difference between the measurement using the paralleling technique and the actuallength(p>0.05). In conclusion. the determination of the root canal length by using the Digora/sup (R)/ system can give us as good an image as the standard periapical radiograph and using the paralleling technique instead of the bisecting angle technique can give a measurement closer to the actual canal length. thereby contributing to a successful result. Also. considering the advantages of the digital imaging processor such as decreasing the amount of exposure to the patient. immediate use of the image. magnification of image size. control of the contrast and brightness and the ability of storing the image can give us good reason to replace the standard periapical radiographs.

  • PDF

예산관리제도의 도입과 실제적 운용에 관한 사례연구 -표준적인 작업의 성과측정을 중심으로- (The Case Study on The Introduction and Practical Application of the Budget Management System -On the Performance Measurement of Standard Work Unit-)

  • 윤용운
    • 산업경영시스템학회지
    • /
    • 제2권2호
    • /
    • pp.39-51
    • /
    • 1979
  • In introducing and applying the budget management system, the question of how to establish management structure(skelton) representing budget management responsible unit is significantly related to the degree of accuracy and analysis on the performance measurement of standard work unit. We have the following rational process of establishing performance measurement of budget management System ; 1) Standardization of work method 2) Establishment of management structure 3) Institution of budget management system. Especially, this system is based on a premise of efficiency of objectives management, it is assumed that performance measurement in the standard work unit must be enforced according to the basis and categories of performance evaluation based on the evaluating work unit. Therefore, most of all, the following three detail questions(subjects) are to be determined in order to rationalize these above principles to a maximum possible extent of performance measurement system. First, we established respective performance standard unit with respect to such detailed work unit, performance standard unit of which were accurately applicable directly from using the budget ana objectives account data and their supplementary data of the work measurement techniques. Second, by using the above mentioned question, over all evaluation and suggestion are made based on the study of the recording for each work unit development, budget management and production nit (volume of production) Third, the measurement of performance of budget management system is based on the principle of standard work unit, compared with the standard basis and actual work unit by period and activities unit and calculated percentage effectiveness according to the above procedure. and so evaluated the efficiency of performance measurement on the budget management system.

  • PDF

Application of a Gas Chromatography/Luminol Detection System for Peroxyacetyl Nitrate Airborne Measurement

  • Khang, Bumju;Ahn, Joon Young;Song, Dasol;Lee, Gangwoong
    • Asian Journal of Atmospheric Environment
    • /
    • 제7권2호
    • /
    • pp.105-113
    • /
    • 2013
  • We constructed and tested an airborne peroxyacetyl nitrate (PAN) monitoring system based on luminol chemiluminescence detection with fast gas chromatography. This system allowed for simultaneous measurement of PAN and nitrogen dioxide ($NO_2$) with a time resolution of <2 min. Actual sample masses within the fixed volume sample loop at various altitudes and temperatures were adjusted to standard atmosphere, using measured pressures and temperatures. The airborne PAN measurement system was evaluated during two field studies above the southern Korean Peninsula in August and October 2009. The detection limit based on the ISO approach was 0.035 ppbv PAN, well below the observed concentrations of 0.185-1.49 ppbv during these studies. Under these conditions, the PAN mixing ratios were positively correlated with $O_x$ ($O_x=O_3+NO_2$), with slopes varying between 0.014 and 0.033 and intercepts between 22.6 and 55.1 ppbv $O_x$. The intercepts corresponded roughly to background $O_x$ mixing ratios in central Europe; however, the slopes were above the range of slopes reported in other studies. We also enhanced the durability, safety, and ease of maintenance of the PAN monitoring system by redesigning the structure of the conventional luminol cell.

3점 방식 불평형량 측정법에서의 오차보상 기법 (Error-compensating Techniques in 3-Point Weighing Method to Measure Unbalance Properties)

  • 이선표
    • 한국정밀공학회지
    • /
    • 제23권11호
    • /
    • pp.42-49
    • /
    • 2006
  • In this paper error-compensating techniques in three-point weighing method to precisely measure unbalance properties such as center of gravity and unbalance moment. In the conventional static methods, 1) fixture-errors, 2) effects of the contact between the fixture and the load scales, and 3) side effect due to the lateral frictional forces acting on the contact points between the fixture and the load scales are the major factors that lead to measurement errors. The proposed error-compensating method perfectly eliminates both the fixture-error and the contact-error simultaneously by manipulating the three measured reaction forces at three different angular locations. Also the friction-error is calibrated by comparing the sum of three reactions with the actual mass of the specimen. A set of measurement is performed using the same measuring system as Lee's, and a comparison of the results from the convectional, Lee's, and the proposed method is provided. The results show that the proposed method effectively compensates the errors listed above.

흘로그램 간섭계를 이용한 광픽업 베이스의 미소 열변형 측정 (Measurement of Micro Thermal Deformation of Optical Pick-up Base Using Holographic Interferometry)

  • 서영민;강신일
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.191-194
    • /
    • 2002
  • In optical pick-up, optical components such as objective lens, collimator, mirror, laser diode and photo diode are mounted on the pick-up base. These components must keep their original position during operation for proper transmittance of information from laser diode to optical disk and back to photo diode. However, micro thermal deformation of pick-up base which is induced by thermal environment during operation can deteriorate the performance of optical pick-up. Therefore, it is important to measure and analyze the thermal deformation behavior of pick-up base under thermal environment. In the present study, a measurement system using holographic interferometry was designed to measure micro thermal deformation of pick up base. The measurement system was verified by using the deformation of cantilever with prescribed motion actuated by PZT with 1 nm resolution. Interferometric measurement was compared quantitatively with that induced by PZT actuator. Finally, micro thermal deformation of pick-up base under actual thermal environment was measured using the present holographic interferometry and the results were analysed.

  • PDF

반도체레이져를 이용한 온도 및 농도의 계측 (Temperature and Concentration measurement using Semi-conductor diode laser)

  • 정대헌;노동순;지전유이
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2000년도 제21회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.168-174
    • /
    • 2000
  • A diode laser sensor system based on absorption spectroscopy techniques has been developed to measure $CO_2$ concentration and temperature non-intrusively in high temperature combustion environments using a 2.0 ${\mu}m$ DFB(Distributed Feedback) laser. Two optics was fabricated in pig-tail fashion and all optical components were implemented in a single box. The evolution of measurement sensitivity was done using test cell by changing sweep frequency and $CO_2$ concentration. Gas temperature was determined from the ratio of integrated line strengths. Species concentration was determined from the integrated line intensity and the measured temperature. The result show that the system has 2% error in wide operation frequency range and accuracy of $CO_2$ concentration was about 3%. The system was applied to measure temperature and concentration in the combustion region of a premixed $CH_4$ +air triangular flame. The measurement results of gas temperature agreed well with thermocouple results. Many considerations were taken into account to reduce optical noise, etalon effect, beam steering and base line matching problem. The evaluations results and actual combustion measurement demonstrate the practical and applicability for in-situ and real time combustion monitoring in a practical system.

  • PDF

인공위성 반작용휠의 미소진동 측정, 해석 및 저감 기술 (Micro-Vibration Measurement, Analysis and Attenuation Techniques of Reaction Wheel Assembly in Satellite)

  • 오시환;이승우
    • 한국항공우주학회지
    • /
    • 제30권8호
    • /
    • pp.126-132
    • /
    • 2002
  • 인공위성의 각종 탑재체에 의해 발생하는 미소진동은 위성의 고정밀 지향도를 떨어뜨리고 고해상도 카메라를 탑재하고 있는 다목적 실용위성 같은 경우, 위성 영상의 해상도 및 분해능을 저하시킨다. 본 논문에서는 인공위성체 미소진동의 가장 큰 요인 중의 하나로 작용하는 반작용휠의 미소진동 측정 기술, 동특성 해석 및 모델링 기술을 소개하고 이의 진동 저감 방법 등을 모색하였다. 이러한 기술들을 토대로 하여 반작용휠과 유사한 동특성을 가지는 진동 발생기를 제작, 미소진동을 측정하였고 수동 감쇄 재료를 이용하여 이를 저감 시키는 실험을 수행하였다.

프로그램 교육목표 평가 모형과 성취도 측정에 관한 연구 (A Study on the Measurement of Performance and Evaluation Model to Achieve the Program Education Objectives)

  • 박익수;박경우
    • 공학교육연구
    • /
    • 제16권6호
    • /
    • pp.52-57
    • /
    • 2013
  • In this paper, the evaluation system in order to achieve the program education objectives of Accreditaion Board for engineering education of Korea, analyze the educational objectives evaluation tool case studies of programs that are run by each university, the program educational objectives to match the actual situation of university I have developed a distinction between questions the evaluation and assessment system. Configuration, execution, measurement, analysis, is a five-step mooring, the evaluation tool, is a graduate research you are currently using the most in Korea, the employer survey, education target assessment model of the program, employment trends of graduates, I decided to graduate focus group interviews. Distinction between questions, the evaluation also developed a questionnaire to derive the important keywords of education for each objectives. Improvement evaluation tool, the evaluation criteria is required, the University is preparing evaluate (NGR) in South Korea engineering education certification next regularly, requires research on semantic analysis of the results of measurement of the educational goals of the program in the future some.