• 제목/요약/키워드: Actual Measurement

검색결과 1,779건 처리시간 0.033초

적외선열화상장치를 이용한 Buchanan plugger 표면의 온도상승 분석 (INFRARED THERMOGRAPHIC ANALYSIS OF TEMPERATURE RISE ON THE SURFACE OF BUCHANAN PLUGGER)

  • 최성아;김선호;황윤찬;윤창;오병주;최보영;정우남;정선와;황인남;오원남
    • Restorative Dentistry and Endodontics
    • /
    • 제27권4호
    • /
    • pp.370-381
    • /
    • 2002
  • This study was performed to evaluate the temperature rise on various position of the Buchanan plugger, the peak temperature of plugger's type and the temperature change by its touching time of heat control spling. The heat carrier system 'System B' (Model 1005, Analytic Technologies, USA) and the Buchanan's plug-gers of F, FM, M and ML sizes are used for this study. The temperature was set to 20$0^{\circ}C$ which Dr. Buchanan's "continuous wave of condensation" technique recommended on digital display and the power level on it was set to 10. In order to apply heat on the Buchanan's pluggers, the heat control spring was touched for 1, 2, 3, 4 and 5 seconds respectively. The temperature rise on the surface of the pluggers were measured at 0.5 mm intervals from tip to 20 mm length of shank using the infrared thermography (Radiation Thermometer-IR Temper, NEC San-ei Instruments, Ltd, Japan) and TH31-702 Data capture software program (NEC San-ei Instruments, Ltd, Japan). Data were analyzed using a one way ANOVA followed by Duncan's multiple range test and linear regression test. The results as follows. 1. The position at which temperature peaked was approximately at 0.5 mm to 1.5 mm far from the tip of Buchanan's pluggers (p<0.001). The temperature was constantly decreased toward the shank from the tip of it (p<0.001). 2. When the pluggerss were heated over 5 seconds, the peak temperature by time of measurement revealed from 253.3$\pm$10.5$^{\circ}C$ to 192.1$\pm$3.3$^{\circ}C$ in a touch for 1 sec, from 218.6$\pm$5.$0^{\circ}C$ to 179.5$\pm$4.2$^{\circ}C$ in a touch for 2 sec, from 197.5$\pm$3.$0^{\circ}C$ to 167.5$\pm$3.7$^{\circ}C$ in a touch for 3 sec, from 183.7$\pm$2.5$^{\circ}C$ to 159.8$\pm$3.6$^{\circ}C$ in a touch for 4 sec and from 164.9$\pm$2.$0^{\circ}C$ to 158.4$\pm$1.8$^{\circ}C$ in a touch for 5 sec. A touch for 1 sec showed the highest peak temperature, followed by, in descending order, 2 sec, 3 sec, 4 sec. A touch for 5 sec showed the lowest peak temperature (p<0.001). 3. A each type of pluggers showed different peak temperatures. The peak temperature was the highest in F type and followed by, in descending order, M type, ML type. FM type revealed the lowest peak temperature (p<0.001). The results of this study indicated that pluggers are designed to concentrate heat at around its tip, its actual temperature does not correlate well with the temperature which Buchanan's "continuous wave of condensation" technique recommend, and finally a quick touch of heat control spring for 1sec reveals the highest temperature rise.

축소모형시험을 통한 공동이 근접터널 굴착에 미치는 영향평가 (Influence of the Existing Cavern on the Stability of Adjacent Tunnel Excavation by Small-Scale Model Tests)

  • 정민철;황정순;김종섭;김승욱;백승철
    • 한국지반환경공학회 논문집
    • /
    • 제15권12호
    • /
    • pp.117-128
    • /
    • 2014
  • 일반적으로 기존 터널이나 공동 등에 근접하여 터널을 시공하는 경우에 기존 공동과 터널간의 간섭이 발생하며 이로 인한 영향을 최소화하기 위하여 이격거리를 터널의 폭 이상으로 유지하도록 일부시방서 등에 권고안이 제시되어 있는 상태이다. 이와같이 공동이나 구조물 등에 근접한 터널은 지반 상태 및 공동의 크기, 보조공법 등을 고려하여 결정하여야 하며, 지반이 연약한 상태에서는 근접도에 따라 민감한 반응을 나타내고 변형량도 크게 나타나므로 지반조건을 고려한 터널계획이 이루어져야 한다. 설계단계에서 공동이 터널의 안정성에 미치는 영향을 검토하기 위해 현장측정, 수치해석, 모형시험 등의 방법이 고려될 수 있으며, 이 중에서 모형시험(Scaled model test)은 결과를 가시적으로 나타낼 수 있을 뿐 아니라, 수치해석과 비교를 통해 거동을 보다 상세하고 현실적으로 예측 가능하다는 장점이 있다. 본 연구에서는 공동에 인접하여 터널 굴착이 이루어지는 경우, 계획단계에서 실제 거동을 예측하기 위한 모형시험 방법과 시험 시 고려사항들에 대해 고찰하고 실제 시험 결과와 수치해석 결과의 비교를 통해 제안된 기법의 적정성을 평가하였다. 또한 터널 굴착 시 터널 주변에 분포하는 공동의 이격거리에 따른 영향이 적절히 반영되는지 여부를 파악하기 위해 공동과 터널간 이격거리를 0.25D, 0.50D, 1.00D, Network 상태 분포 시로 가정한 일련의 모형시험을 수행하였으며, 공동이 없는 조건과 비교하여 제안된 방법의 적정성을 확인하였다. 추가적으로 축소모형시험 결과의 타당성 검증을 위한 목적으로 시험조건을 반영한 수치해석을 수행하였으며, 수치해석 결과와 모형시험 결과의 비교 검증을 수행하였다. 모형시험 및 수치해석 결과 이격거리 1.0D는 공동과 터널이 독립적인 거동을 보이는 한계거리로 평가되었다.

핵의학과 내에서의 효과적인 고객위험관리: 위험관리 응대 MOT 개발적용 및 홍보동영상 제작 (Effective Customer Risk Management at the Nuclear Medicine Department: Risk Managemont MOT Development Application and Producing Public Relations Film)

  • 함종훈;황재봉;김준호;이귀원
    • 핵의학기술
    • /
    • 제13권3호
    • /
    • pp.110-122
    • /
    • 2009
  • 목적: 최근 의료기관평가제도는 의료의 질에 대한 병원들의 관심을 높게 하고 그것을 향상시키기 위한 활동을 활발히 전개하고 있다. 또한 추가된 항목인 환자의 위험관리에 대해서도 많은 관심을 보이고 있다. 의정부성모병원 핵의학과는 2008년도 PET/CT도입으로 시작된 부서내 리모델링은 과내 구조 및 업무 프로세스에 많은 변화를 가져왔다. 따라서 변경된 구조와 기존의 업무 처리방식은 미처 알지 못하는 위험요인을 내포하게 되었다. 그러므로 영상 검사 과정에서 발생할 수 있는 위험요인을 다각도로 찾고 분석하여, 부서의 특수한 환경에 맞는 위험관리 프로세스와 위험요인 제거업무를 포함한 개선 활동을 목적으로 한다. 실험재료 및 방법: 핵의학과의 새로워진 프로세스를 다각도로 분석하여 첫째, 위험관리 응대메뉴얼을 제작하여 교육후 실제 업무에 적용한다. 결과분석은 전년도 위험사고 발생건수와 개선활동 후 위험사고 발생건수를 비교하였다. 둘째, 위험관리 홍보동영상은 제작 후 검사전 해당 환자에게 상영하였고 그 후 자체 제작된 설문지로 해당 환자 100명에게 만족도 조사를 하였다. 셋째, 위험요소를 개선할 수 있는 시설물 참여형 개선활동을 통해서 위험요소를 제거하였다. 결과: 안전사고 발생건수는 개선활동이후 PET/CT와 감마카메라 영상 검사 모두 검사건수대비 투약오류, 낙상, 충돌 등의 안전사고가 0건으로 조사되었다. 설문조사 결과는 동영상 상영 후 검사진행과정 이해 74%, 불안감해소 81%로 "만족한다"는 결과가 조사되었다. "위험요소에 대해 주의했습니까?" 라는 물음의 경우 PET/CT는 94%, 감마카메라는 89%가 주의했다는 결과로 조사되었다. 개선활동을 통해서 핵의학과내에서의 고객위험관리를 효과적으로 수행할 수 있었다. 결론: 본 개선활동을 통하여 영상 검사 시 산재된 위험요소를 체계적으로 나열하고 분석하는 계기가 되었다. 또한 안전사고에 대처하는 방사선사의 업무방법에서도 기준이 되는 응대메뉴얼을 적용시킨다면 안전사고의 최소화와 안전사고시 체계적인 피드백이 가능함을 알 수 있었다. 위험요소를 알려주는 방법론적인 부분에서도 일상생활에서 쉽게 접할 수 있는 시청각자료로 제공 되었을 때 보다 효과적이였다. 따라서 이런 활동이 지속적이고 세부화 된 업그레이드 작업을 통해서 환자들에게 제작되어 제공된다면 핵의학 검사 이용의 안전성과 편리성에 도움을 줄 수 있으리라 생각된다.

  • PDF

퇴원환자의 가정간호요구와 가정간호사업의 효과 분석 - 일 종합병원을 중심으로 (A Study of Home Care Needs of Patients at Discharge and Effects of Home Care -Centered on Patients Discharged from a Rural General Hospilal-)

  • 최연순;김대현;서미혜;김조자;강규숙
    • 대한간호
    • /
    • 제31권4호
    • /
    • pp.77-99
    • /
    • 1992
  • The study was carried out at W. hospital, an affiliated hospital of Y university, involved a total of 163 patients who were discharged from the hospital between May 1990 und March 199J. Data collection was twice, just prior to discharge and a minimum of three months post discharge. Thirty patients who lived within a hour travel time of the hospital received home care during the three months post discharge. Nursing diagnoses and nursing interventions For these patients were analyzed in this study. The results of the study are summarized as follows : 1. Discharge needs for the subjects of the study were analyzed using Gordon's eleven Functional categories and it was found that 48.3% of the total sample had identified nursing needs. Of these, the needs most frequently identified were in the categories of sexuality, 79.3 %, health perception, 68.2 % self concept, 62.5 %, and sleep and rest 62.5 %. Looking ut j he nursing diagnosis that were made for the 30 patients receiving home care, the following diagnoses were the most frequently given; alteration in sexual pattern 79.3%, alterations in health maintenance, 72.6%, alteration in comfort, 68.0%, depression, 64.0%, noncompliance with diet therapy, 6.3.7%, alteration in self concept, 55.6%, and alteration in sleep pattern, 53%. 2. In looking at the effects of home nursing care as demonstrated by changes in the functional categories over the three month period, it was Found that of the 11 functional categories, the need level for health perception, nutrition, activity and self concept decreased slightly over the three month period. On the average sleep patterns improved, but restfulness was slightly less and bowel elimination patterns improved but satisfaction with urinary elimination was slightly less. On the other hand, role enactment, sexuality, stress management and spirituality decreased slightly. The only results that were statistically significant at the 0.05 level were improvement. in digestion and decrease in pain. No statistically significant changes were found in ability related to ADL, the total ADL Score at discharge was $19.78{\pm}8.234, and after 3 months $19.01{\pm}8.12$. Considering that a majority of the patients were over 60 years of age and that many had brain or spinal cord injuries, the fact that their ADL ability did nor deteriorate after discharge can be interpreted as related to a positive impact by the home health care nurses. Similarly there was a slight be not statistically significant decrease in the quality of life scores between the two lest times(l47.83 at discharge and 113.02 at the three month period). Again, when the chronic nature of thee problems facing these patients is considered this maintenance of quality of life can be interpreted as a positive impact by the home health care nurses. 3. One of the home care nursing activities was diagnosis. For this activity it was found that for nine functional health categories(sexuality and spirituality excepted) there were 20 nursing diagnoses. The most frequent were noncompliance, alteration in skin integrity both actual and potential, and impaired physical mobility in that order. 4. Delivery of home health care by the home health nurses included the following nursing activities; assessment, patient education, demonstration of care activities, counselling, direct care to the patient and referrals. Direct care included changing dressings, bladder irrigations, changing Foley catheters, measurement of residual urine, perineal care, position change, back care, oral hygiene, exercise and massage of motion exercises, cleansing enemas, tracheostomy suctioning and tracheostomy care, care of dentures, applications of heat and other similar nursing activities. In conclusion almost 50% of (he sample indicated a need for continued nursing care at the time of discharge and for the patients in the sample who received home care there was a slight decrease in nursing needs but while the patients had chronic and debilitation problems there was ill decrease in ADL abilities or in quality of life. Further study needs Lo be done La increase the reliability and validity of the tool that was used to measure home health care needs. It is also recommended that study by done using a randomized sampling with a control group to compare patients who receive home care with those who do not.

  • PDF

폐암 환자의 정위적방사선 치료 시 이중 에너지를 이용한 치료 방법의 유용성 평가 (Evaluation of useful treatment which uses dual-energy when curing lung-cancer patient with stereotactic body radiation therapy)

  • 장형준;이영규;김영재;박영규
    • 대한방사선치료학회지
    • /
    • 제28권2호
    • /
    • pp.87-99
    • /
    • 2016
  • 목 적 : 종양의 위치에 따라 단일에너지를 이용한 치료계획과 이중에너지를 사용하는 치료계획을 정위적방사선 치료에 적용하여 실제 종양에 부여되는 선량의 변화와 종양과 인접한 부분에 위치하는 정상조직의 선량을 비교하여 임상적 유용성을 평가하고자 한다. 대상 및 방법 : 총 10명의 환자 CT 영상을 획득한 후 각각 단일에너지, 이중 에너지에 대한 체적변조회전치료 기법에 대한 치료 계획을 수립하였다. 종양 측 변화 요인을 분석하기 위하여 조형계수(CI)와 균질성 지수(HI), 최대 선량을 각각 계산했으며, 정상 조직에 대한 선량 분포를 비교하기 위하여 $V_{10}$$V_5$, 종양에 가장 근접한 첫 번째 ~ 네 번째 갈비뼈($1^{st}{\sim}4^{th}$ Rib), 척수(Spinal Cord), 식도(Esophagus)와 기관(Trachea)를 선정하였다. 또한 계획한 선량 분포가 실제 전달되는 정확성을 확인하기 위하여 2차원 이온전리함 배열을 이용하여 선량 측정을 시행하였다. 결 과 : 종양 측 인자의 경우 조형계수와 균질성 지수는 두 에너지를 사용했을 경우가 1에 가까운 값을 나타냈다. 최대 선량의 경우 앞쪽 흉벽은 약 2%, 등쪽 종양의 경우는 동등한 값을 나타냈다. 정상 조직의 경우 앞쪽 흉벽 종양은 인접한 갈비뼈에서 두 에너지를 동시에 사용한 경우 각각 4%, 5% 감소하였고, 기관지의 경우 11%, 17% 감소하였다. 폐의 선량 분포의 경우 $V_{10}$의 경우 1.5%, $V_5$의 경우 1%로 감소함을 나타냈다. 뒤쪽 흉벽의 경우 종양에 인접한 갈비뼈는 두 에너지를 이용한 경우에서 각각 6%, 1%, 4%, 12% 감소하였고, 폐의 선량 분포에서는 $V_{10}$ 3%, $V_5$ 3.1% 감소됨을 나타내었다. 선량 측정의 경우 모든 에너지에서 감마지표 3mm/3%의 결과에 부합하였다. 결 론 : 단일 에너지를 이용한 치료 계획 보다 두 에너지를 동시에 사용하는 경우가 표재성 종양에 대해 보다 유용하게 적용될 수 있을 것으로 사료된다.

  • PDF

한국 남해안에서 단일 및 복수 기준국에 의한 DGPS의 측위정도 비교 (Comparison of the DGPS Positioning Accuracies for Single and Multiple Reference Stations in the South Coast of Korea)

  • 박노선;신형일;이대재;신현옥;김석재;배문기
    • 수산해양기술연구
    • /
    • 제38권3호
    • /
    • pp.181-189
    • /
    • 2002
  • 한국의 DGPS 측위정도와 복수 기준국을 이용하였을 때의 측위정도를 연구하기 위하여 2001년 1월부터 10 월까지 해상용 DGPS수신기(MGP-100D, GP-36) 를 이용하여 여수, 부산의 고정점에서 정점관측을 행하였으며, 측위정도의 변화를 조사하기 위해 부경대학교 내의 회류 수조에서 2001년 10월 15일~22 일까지 일주일 동안 관측을 행하였다. 또한 DGPS 기준국의 유효 이용범위에 대해 조사하기 위해 2001년 1월 9일~18일 사이에 한국남해안을 항해, 정박하면서 실험을 행하였으며, 그 결과를 요약하면 다음과 같다. (1) 단일 기준국을 이용하였을 때의 2drms 와 기준점으로부터 평균위치까지의 편위거리는 각각 5.6m, 7.3m 이었고, 실제 위치로부터 한쪽 방향으로 편향되어 나타났다. (2) 복수 기준국을 이용하여 산술평균하였을 때의 2drms와 기준점으로부터 평균위치까지의 편위거리는 각각 5.5m, 3.2m 이었고, 가중평균 하였을 때의 2drms와 기준점으로부터 평균위치까지의 편위거리는 각각 5.3m. 3.8m 이었다. 또한 사용자가 기준국으로부터 멀어질수록 복수 기준국을 이용하는 쪽이 측위정도가 더 향상되는 것으로 나타났다. (3) 측위오차 일변화는 16~22시 사이에 증가하였고, 관측된 평균 위성 수와 HDOP는 각각 7.lm, 0.49이었다. (4) 한국 남해안을 항해하며 DGPS 기준국의 유효범위를 조사한 결과. 1l0nm인 것으로 나타났으며, 신호강도는 19㏈ 이하, 신호 대 잡음비 8㏈ 이하에서는 기준국 보정정보를 이용할 수 없었다. 이와 같이 한국 남해안 일대에서의 측위 실험결과 복수 기준국을 이용하는 것이 단일 기준국을 이용하는 것보다 측위정도가 더 개선되는 것으로 나타났으며, 기선장이 길수록 복수 기준국을 이용하는 쪽이 더 양호한 정도를 나타내었다.

음식물쓰레기의 고온 혐기성 소화도에 미치는 요소에 대한 분석 (Analysis of the Factors Affecting Anaerobic Thermophilic Digestibility of Food Wastes)

  • 김도희;현승훈;김경웅;조재원;김인수
    • 유기물자원화
    • /
    • 제8권2호
    • /
    • pp.130-139
    • /
    • 2000
  • 일련의 회분식실험을 통하여 음식폐기물의 동력학상수 및 메탄가스 발생량을 측정하였으며 음식폐기물의 고온혐기성 소화시 입자의 크기, 나트륨이온의 농도, 휘발성 고형물의 부하량이 따른 운전인자에 대한 영향을 살펴보았다. 기초 동력학 실험에서는 최대 기질 분해 속도 상수 k는 $0.24hr^{-1}$로 나타났으며 반 포화상수 Ks는 $700mg/{\ell}$ 로 나타났다. 나트륨 농도에 따른 혐기성소화 영향에 관한 실험은 나트륨 농도가 $5g/{\ell}$ 까지는 총 메탄가스 발생량에 영향을 미치지 않았으나 점차로 농도가 증가함에 따라 총 메탄가스 발생량이 감소하기 시작하였으며 나트륨 농도가 $20g/{\ell}$ 로 증가시켰을 경우 이론적인 발생량의 50% 만을 발생하였다. 음식폐기물을 크기별로 분쇄하여 혐기성 소화를 시킨 후 Valentini 모델에 적용시킨 결과 모든 경우에 있어서 가수분해 상수 값 A는 0.45를 나타내었으며 입자의 크기가 1.02 mm에서 2.14 mm로 높아짐에 따라 최대 기질 분해 속도 상수 $k_{HA}$$0.0033hr^{-1}$에서 $0.0015hr^{-1}$로 감소하였다. 이것으로 음식폐기물의 혐기성 소화에 있어서 입자 크기가 중요한 운전인자 중의 하나임을 증명할 수 있었으며 휘발성 고형분의 부하량에 관한 연구에서는 최대 주입 휘발성 고형물 부하량은 $40g/{\ell}$ 로 나타났으며, 유기물 부하가 낮은 경우에서는 나트륨 이온에 따른 영향이 휘발성 고형물 제거에 나타나지 않았으나 $40g/{\ell}$ 인 경우 약간의 차이가 있는 것으로 판명되었다.

  • PDF

원자력등급 ESF 공기정화계통 시뮬레이터 제작 및 활용에 관한 연구 (A Study on Construction and Application of Nuclear Grade ESF ACS Simulator)

  • 이숙경;김광신;손순환;송규민;이계우;박정서;홍순준;강선행
    • 방사성폐기물학회지
    • /
    • 제8권4호
    • /
    • pp.319-327
    • /
    • 2010
  • 공학적 안전설비 공기정화계통과 관련된 실험 수행을 위해 원자력등급 ESF 공기정화계통 시뮬레이터를 설계, 제작, 검증하였다. 영광 5,6호기 주제어실 공기정화계통의 공급자 정보, 도면 등을 기준으로 실사를 통해 치수를 확인하여 3D CAD 모델을 작성하였다. 모델과 현장 계통의 실측 유량을 기준으로 CFD 분석을 수행하였다. 공기정화계통으로 유입되는 공기는 $30^{\circ}C$, 유동형태는 균일한 것으로 가정하고, 검사 기록지에 의한 주제어실 ESF 공기정화계통의 유량이 12,986 CFM이고, $610{\times}610mm^2$의 HEPA 필터가 9개 설치되어 있으므로 HEPA 필터 단면를 지나는 유속은 1.83 m/s이다. 주제어실 공기정화계통 모델링시 공기 유동이 흐르지 않는 필터 테두리 지지대를 고려하여 현장과 유사한 유동현상을 모사하였다. 약 8 m/s로 기록된 활성탄 흡착기 하단의 공기유동은 별도의 분석을 통해 7 m/s 이상의 유속이 모사되도록 CFD 분석하였다. 연료건물 비상배기계통 및 비상노심냉각계통 기기실 배기정화계통의 공기정화계통에 대해서도 CFD 분석한 결과, 시뮬레이터의 유속을 조절하면 세가지 ESF 공기정화계통을 모두 모사할 수 있음을 확인하였다. CFD 분석 후 시뮬레이터를 원자력등급으로 제작하였고, 본 실험에 착수하기 전에 공기유동 분포도실험을 통해 시뮬레이터의 신뢰도를 검증하였다. 검증결과 중급 필터를 장착한 상태에서 시뮬레이터의 필터 지지대 부분을 제외한 내부에서 공기유동이 고르게 분포함을 확인하였고, 제작된 시뮬레이터는 Reg. Guide 1.52(Rev.3) 개정 내용 확인을 위한 실험에 사용되었다.

Hydrocyclone Filter 장치를 이용한 강우유출수내 미세입자 제거특성 분석 (Performance Evaluation of Hydrocyclone Filter for Treatment of Micro Particles in Storm Runoff)

  • 이준호;방기웅;홍성철
    • 대한환경공학회지
    • /
    • 제31권11호
    • /
    • pp.1007-1018
    • /
    • 2009
  • Hydrocyclone은 높은 수면적부하율 운전이 가능하고, 구동부분이 없고, 운전 및 유지관리비가 적게 소요되어 미세입자물질제거에 효과적인 장치로 다양한 산업 분야에서 활용되고 있다. Hydrocyclone에 나선형 유입부를 통해 직각으로 유입되어 중력이 아닌 원심력에 의해 입자물질이 하부배출구로 분리되고 처리수는 vortex finder를 통해 배출된다. 입자분리에 hydrocyclone은 많은 장점을 가지고 있음에도 불구하고 도시지역 강우유출수 처리사례는 드문 실정이다. 본 연구에서는 변형된 hydrocyclone과 perlite 여재를 조합한 hydrocyclone filter (HCF)을 이용하여 강우유출수내 미세입자의 제거능을 분석하였다. 입자물질들은 인공입자들을 이용하여 강우유출수내 입자농도를 모의 실험하였다. 인공입자들을 물에 분산시켜 강우유출수를 재현하였는데 사용한 입자들은 이온교환 수지, 도로측구 퇴적물질, 상업지역 맨홀퇴적물질, 그리고 실리카겔 등이다. 하부배출부와 vortex finder 구조를 달리하여 HCFopen system과 HCF-closed system으로 구분하여 처리능을 분석하였다. HCF장치는 아크릴 수지를 이용하였는데 hydrocyclone의 직경은 120 mm이고 여과조의 직경은 250 mm이고 전체적인 높이는 800 mm로 제작하였다. 운전조건별 유입수 농도와 입경을 다양하게 적용하였고 SS와 COD농도를 분석하여 처리효율을 산정하였다. HCF-open system의 경우 운전 가능한 최대 수면적부하율은 700 $m^3/m^2$/day이었고 HCF-closed system의 경우 수면적부하율 1,200 $m^3/m^2$/day까지이다. HCF-open system 운전결과 HCFclosed system에 비교하여 평균 수면적부하율은 2배 이상 높게 운전이 가능하며 처리효율도 8~20% 이상 향상되는 것으로 분석되었다. 또한 유입수 SS농도가 높을수록 처리효율이 증가하며, 입경이 클수록 수면적부하율의 변화에 대한 처리효율의 영향이 적은 것으로 분석되었다. HCF-closed system의 실험을 통한 수면적부하율 변화에 대한 실리카겔입자의 제거 효율과 CFD입자추적기법을 이용한 예측 처리효율을 비교한 결과 CFD에 예측효율이 실제실험결과와 비교하여 다소 높게 나타나지만 처리효율의 경향은 매우 유사하게 나타나 CFD추적기법을 이용한 HDS유형 처리장치 설계 시 유용한 도구로 활용될 수 있을 것으로 판단된다.

구강암 환자의 종양 선량 측정을 위한 In-vivo Diode Dosimetry의 유용성 평가 (Evaluation of Usefulness on In-vivo Diode Dosimetry for Measuring the Tumor Dose of Oral Cancer Patient)

  • 나경수;이제희;박흥득
    • 대한방사선치료학회지
    • /
    • 제17권2호
    • /
    • pp.133-140
    • /
    • 2005
  • 목 적 : 3차원치료계획 (3D plan)과 대향2문조사(POP plan)의 선량 계획시 치료표적 (Planning Target Volume, PTV)와 정상조직(Organ at Risk, OAR)에 실제 흡수되는 선량을 반도체검출기를 이용하여 실시간선량측정(Real- time dosimetry)을 시행함으로써 치료계획의 타당성을 확인하고자 한다. 대상 및 방법 : 실제 치료할 환자의 구강안을 채워줄 Aquaplaste를 Simulation과정에서 제작하며 측정하고자 하는 부위에 Aquaplaste를 성형하여 반도체 검출기가 자리할 공간을 확보한다. 치료시 반도체검출기를 측정부위에 위치시키고 치료가 진행중 각 Port에 해당하는 Electrometer의 지시치를 얻는다. 얻은 지시치에 선량변환계수(Diode Calibration Factor, DCF)를 이용하여 실제 선량으로 환원하여 Exp. Dose와 실제 Dose를 비교하며 오차를 구한다. 실험의 수를 증가시켜 보다 정확한 결과를 얻기 위하여 Alderson Rando phantom(Huestis, USA)을 이용하여 같은 실험을 반복한다. 결 과 : 대향2문조사를 한 A환자의 경우 Exp. value와 측정선량의 비(exp.D/eff.D)가 197.5/199로 -1.2%, 3차원치료계획을 한 B환자는 exp.D/eff.D가 199.9/198.7로 +0.6%, C환자의 경우 exp.D/eff.D가 196/200으로 -1.5%가 차이 남을 알 수 있었다. 또 Target dose 외에 방어하고자 하는 부위의 측정도 병행한 C환자의 결과치는 96/200으로 47%의 선량이 측정되어 방어의 목적을 달성했음을 알 수 있었다. Phantom을 이용한 측정에서는 A환자와 같이 (a) point(target), (b) point(protect)로 나뉘어 측정하여 다음의 결과치를 얻었다. Phantom 1 (a): 190.6/198.4=-3.9%, (b): 119.6/124.2=-3.7%, Phantom 2 (a): 185.4/191.3=-3%, (b): 109.6/113.8=-3.7%의 결과치를 얻어 목적한 선량에 ${\pm}5%$이내로 만족함을 알 수 있었다. 결 론 : 반도체검출기를 이용한 치료전 선량 측정의 유용성을 알아본 이번 실험은 Target dose 뿐만 아니라 방어하고자 하는 영역 또한 알아봄으로써 치료의 타당성을 확인하는데 매우 유용했고 단순선량계산에 의한 확인되지 않는 Target dose를 확인하는 데에도 큰 이점이 있다고 생각된다. 치료 전 L-gram과 같이 이런 측정은 매우 효과적으로 치료방법의 타당성과 이후의 치료계획에도 많은 이득을 가져다 줄 것이라고 생각된다.

  • PDF