• Title/Summary/Keyword: Active release technique

Search Result 31, Processing Time 0.025 seconds

Effects of the Graston Technique and Self-myofascial Release on the Range of Motion of a Knee Joint (글라스톤 기법을 이용한 연부조직가동술과 자가근막이완술이 넙다리뒤근 유연성에 미치는 영향)

  • Kim, Do-Hyun;Kim, Tae-Ho;Jung, Do-Young;Weon, Jong-Hyuck
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.9 no.4
    • /
    • pp.455-463
    • /
    • 2014
  • PURPOSE: The purpose of this study was to compare the effects of Graston and self-myofascial release (SMR) techniques on knee joint flexibility, hamstring, and quadriceps strength. METHODS: Twenty subjects with hamstring shortness participated in this study. The subjects were assigned randomly to one of two groups: The Graston technique (GT) group received intervention using a Graston instrument for one minute, and the SMR group performed self-exercises using a foam roll for one minute. The range of motion (ROM) of the knee joint was measured by active knee extension test, and a handheld dynamometer was utilized to collect the hamstring and quadriceps muscle strength. This experiment was performed by two physical therapists. The significant level was set at ${\alpha}$=0.05. RESULTS: The results were as follows: 1) The ROM of the knee joint and quadriceps muscle strength were significantly increased in both groups. 2) Hamstring muscle strength was significantly reduced in both groups. 3) There were no significant differences between the GT group and SMR group for any variable. CONCLUSION: The results of this study suggest that SMR is an effective and easy technique for restoring proper muscle length and strength in subjects with hamstring shortness. We recommend that SMR technique be used for treat hamstring shortness in clinical setting and home-program.

Echinacoside, an active constituent of Herba Cistanche, suppresses epileptiform activity in hippocampal CA3 pyramidal neurons

  • Lu, Cheng-Wei;Huang, Shu-Kuei;Lin, Tzu-Yu;Wang, Su-Jane
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.22 no.3
    • /
    • pp.249-255
    • /
    • 2018
  • Echinacoside, an active compound in the herb Herba Cistanche, has been reported to inhibit glutamate release. In this study, we investigated the effects of echinacoside on spontaneous excitatory synaptic transmission changes induced by 4-aminopyridine (4-AP), by using the in vitro rat hippocampal slice technique and whole-cell patch clamp recordings from CA3 pyramidal neurons. Perfusion with echinacoside significantly suppressed the 4-AP-induced epileptiform activity in a concentration-dependent manner. Echinacoside reduced 4-AP-induced increase in frequency of spontaneous excitatory postsynaptic currents (sEPSCs) but it did not affect the amplitude of sEPSCs or glutamate-activated currents, implicating a presynaptic mechanism of action. Echinacoside also potently blocked sustained repetitive firing, which is a basic mechanism of antiepileptic drugs. These results suggest that echinacoside exerts an antiepileptic effect on hippocampal CA3 pyramidal neurons by simultaneously decreasing glutamate release and blocking abnormal firing synchronization. Accordingly, our study provides experimental evidence that echinacoside may represent an effective pharmacological agent for treating epilepsy.

Effects of PNF Contract-Relax Technique, Myofascial Release, and Massage Guns on Hamstring Flexibility and Pressure Pain Threshold in Subjects with Hamstring Shortening (PNF 수축-이완 기법, 근막이완기법, 마사지건이 넙다리뒤근 단축 대상자의 유연성 및 압통에 미치는 영향)

  • So-Young Jeong;Ho-Seong Hwang;Da-Eun Lee;Du-Jin Park
    • PNF and Movement
    • /
    • v.21 no.1
    • /
    • pp.63-74
    • /
    • 2023
  • Purpose: This study aims to compare hamstring flexibility and pressure pain threshold (PPT) after an intervention with proprioceptive neuromuscular facilitation contract-relax (PNF CR) technique, myofascial release (MFR), and a massage gun (MG), as well as to verify the effectiveness of the MG. Methods: This study recruited 36 participants (22 males and 14 females) with shortening of less than 70 degrees upon a straight leg raise (SLR) test, and they were randomly assigned to one of the PNF, MG, and MFR groups, each of which underwent its own protocol for 30 minutes. Flexibility of the hamstring was measured after the intervention using the active and passive knee extension (AKE and PKE) test, the sit and reach test, and PPT. Results: The AKE and PKE angles significantly decreased, as well as significantly increased in flexibility when each of the PNF, MFR, and MG interventions was performed (p<0.05). In addition, there was no significant difference among groups. However, according to the Cohen's D effect size, the MG demonstrated the largest effect size in AKE (d = 1.41) and PNF demonstrated the largest effect size in PKE (d = 1.66) and flexibility (d = 0.63). Conclusion: All interventions used in our study are effective in increasing hamstring flexibility. Based on the Cohen's D effect size, an MG is beneficial to increase the AKE, whereas PNF CR technique is recommended for increasing PKE and flexibility.

Methods of measuring presynaptic function with fluorescence probes

  • Yeseul Jang;Sung Rae Kim;Sung Hoon Lee
    • Applied Microscopy
    • /
    • v.51
    • /
    • pp.2.1-2.7
    • /
    • 2021
  • Synaptic vesicles, which are endogenous to neurotransmitters, are involved in exocytosis by active potentials and release neurotransmitters. Synaptic vesicles used in neurotransmitter release are reused via endocytosis to maintain a pool of synaptic vesicles. Synaptic vesicles show different types of exo- and endocytosis depending on animal species, type of nerve cell, and electrical activity. To accurately understand the dynamics of synaptic vesicles, direct observation of synaptic vesicles is required; however, it was difficult to observe synaptic vesicles of size 40-50 nm in living neurons. The exo-and endocytosis of synaptic vesicles was confirmed by labeling the vesicles with a fluorescent agent and measuring the changes in fluorescence intensity. To date, various methods of labeling synaptic vesicles have been proposed, and each method has its own characteristics, strength, and drawbacks. In this study, we introduce methods that can measure presynaptic activity and describe the characteristics of each technique.

COMBUSTION TOXICITY ANALYSIS: ADVANCES USING A SPECIALIZED SAMPLING TECHNIQUE FOR FOURIER TRANSFORM INFRARED (FTIR) ANALYSIS

  • Talandis, Jonas;Innes, J.D.;Cox, A.W.
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.178-184
    • /
    • 1997
  • The cone calorimeter as defined by ISO 5660, ASTM 1354, and NFPA 264A is used to assess the reaction to fire of almost any material that must be evaluated in the fire science field. Typical combustion gas analyses include oxygen, CO and CO2. Oxygen consumption is used to determine rate of heat release. Analysis of combustion gases other than oxygen, CO and CO2 has been attempted using filters to remove the solid smoke particles before analysis. This method has generated unreliable results due to the adsorption of many gas components on the active carbon . particles deposited on the filters. A technique using fourier Transform Infrared (FTIB) analysis without filtration will be disclosed and a discussion will be presented of the analytical results of toxic gases produced from various flame retarded polymeric materials. Use of such data in lethal toxic potency determinations is also reviewed.

  • PDF

Immediate effect of self-myofascial release on hamstring flexibility

  • Jung, Jihye;Choi, Wonjae;Lee, Yonghyuk;Kim, Jiwoo;Kim, Hyunju;Lee, Kyoungho;Lee, Jaewoo;Lee, Seungwon
    • Physical Therapy Rehabilitation Science
    • /
    • v.6 no.1
    • /
    • pp.45-51
    • /
    • 2017
  • Objective: This study aimed to identify the area with greatest effect using self-myofascial release technique (self-MFR) in the hamstring, suboccipital, and plantar regions. Design: Cross-sectional study. Methods: Twenty-two adult subjects were evaluated for flexibility and hamstring pain threshold after self-MFR. Based on the superficial back line, the self-MFR application areas were the suboccipital region, hamstring, and plantar regions. Self-MFR was applied to each area using a wooden pole for a total of 4 minutes. Self-MFR was applied for 3 days at the same time of day, which was randomly assigned for each subject. Treatment was applied to one area each day. The sit and reach test (SRT), active range of motion (AROM), and passive ROM (PROM) were used to determine changes in flexibility, and an algometer was used to determine pain threshold. Pre/post-self-MFR effectiveness was tested using a paired t-test. Repeated measurement was used to compare self-MFR effects in the suboccipital, hamstring, and plantar regions. Results: When the self-MFR technique was applied to the 3 areas, the SRT showed significant improvement over baseline (p<0.05). Bilateral AROM and PROM showed significant improvements (p<0.05). When the self-MFR technique was applied to the hamstring, the semimembranosus showed a significant change in pain threshold (p<0.05). Conclusions: Our findings suggest that indirect application based on the Anatomy Trains could be effective for those who need to improve muscle flexibility. Moreover, self-MFR easily alleviates myofascial pain while maintaining flexibility, and can be performed at any time and place.

Development of Gas Detector Location Index Technique to Prevent Explosion Accidents of Offshore Plant (해양플랜트 폭발사고 방지를 위한 가스감지기 위치 선정 방법 연구)

  • Sohn, Jung Min;Paik, Jeom Kee;Kim, Sang Jin
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.54 no.1
    • /
    • pp.63-70
    • /
    • 2017
  • Release of hazardous and flammable gas is a significant contributor to risk. The ignition of flammable gas clouds can lead to explosion accidents in the offshore installations. A gas detector, which is one of active protect systems, brings the module into a safe state through emergency shut down processes and reduces the damage by eliminating the dangerous releases. It is critical to understand the gas release, the wind field, and the complex geometry of installations to determine gas detector placement. In this paper, the Gas detector Location Index (GLI) which is a novel index for optimal detector location determination to efficiently prevent explosion accident using probabilistic approach.

Effects of High-frequency Diathermy Integrated into Suboccipital Release on Tenderness and Neck Mobility and Disability in People with Chronic Tension-type Headache (뒤통수밑근 이완기법과 병행된 고주파 심부투열이 만성 긴장성 두통 환자들의 압통과 목 가동성 및 기능장애에 미치는 영향)

  • Lee, Hyoung-ryeol;Shim, Jae-hun;Oh, Duck-won
    • Physical Therapy Korea
    • /
    • v.24 no.2
    • /
    • pp.37-47
    • /
    • 2017
  • Background: Active trigger points (TrPs) of the suboccipital muscles greatly contribute to the occurrence of chronic tension-type headache, with increased sensitivity of TrPs and facilitated referred pain. Objects: This study aimed to investigate whether the integration of high-frequency diathermy into suboccipital release is more beneficial than the use of suboccipital release alone. Methods: Thirty subjects were assigned to either experimental group-1 (EG-1) to undergo suboccipital release combined with high-frequency diathermy (frequency: 0.3 MHz, and electrode type: resistive electronic transfer), or EG-2 to undergo suboccipital release alone, or the control group (CG) with no intervention, with 10 subjects in each group. The assessment tools included the headache impact test 6 (HIT-6), perceived level of tenderness, neck disability index, and neck mobility. Intervention was performed for 10 minutes, twice per week, for 4 weeks, and measurements were performed before and after the interventions. Results: The between-group comparison of the post-test values and changes between pretest and post-test showed significant differences for all parameters at p<.05, except for the left-to-right lateral bending range. In the post hoc test, EG-1 showed significant differences for the parameters in comparison with the CG, while no significant differences in the perceived tenderness level, on both temporal regions, were found between EG-2 and CG. Furthermore, the HIT-6 score and perceived tenderness level, in the right temporal region, showed significant differences between EG-1 and EG-2. In the within-group comparison, EG-1 and EG-2 appeared to be significantly different between pretest and post-test (p<.05), except for the perceived tenderness level in the right temporal region, with significance for the EG-1 group only (p<.05). Conclusion: These findings suggest that the suboccipital release technique may be advantageous to improve headache, tenderness, and neck function and mobility, with more favorable effects with the incorporation of high-frequency diathermy.

Partial Encryption Technique of Digital Contents (디지탈 컨텐츠의 부분 암호화 기법)

  • Hwang, Seon-Tae
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.8 no.1
    • /
    • pp.82-87
    • /
    • 2002
  • In the rapidly growing e-business area, the protection of information from hacking or tapping becomes very serious issue. Therefore, the more effective, convenient and secure methods are required to make the e-business more active. in this study, we develop the effective method of protecting digital contents on the public key infrastructure. To do this, we propose the partial encryption scheme to reduce the encryption time, and therefore, to release the server's workload. Our suggested scheme is believed to bring the strong competition to the portal service agents.

Application of Supercharge End-to-Side (SETS) Obturator to Femoral Nerve Transfer in Electrical Injury-Induced Neuropathy to Improve Knee Extension

  • Katie Pei-Hsuan Wu;Li-Ching Lin;Johnny Chuieng-Yi Lu
    • Archives of Plastic Surgery
    • /
    • v.49 no.6
    • /
    • pp.769-772
    • /
    • 2022
  • Femoral nerve injuries are devastating injuries that lead to paralysis of the quadriceps muscles, weakening knee extension to prohibit ambulation. We report a devastating case of electrical injury-induced femoral neuropathy, where no apparent site of nerve disruption can be identified, thus inhibiting the traditional choices of nerve reconstruction such as nerve repair, grafting, or transfer. Concomitant spinal cord injury resulted in spastic myopathy of the antagonist muscles that further restricted knee extension. Our strategy was to perform (1) supercharge end-to-side technique (SETS) to augment the function of target muscles and (2) fractional tendon lengthening to release the spastic muscles. Dramatic postoperative improvement in passive and active range of motion highlights the effectiveness of this strategy to manage partial femoral nerve injuries.