• Title/Summary/Keyword: Active pad

Search Result 51, Processing Time 0.037 seconds

A Study on the Anti-Vibration Characteristics of the Under Sleeper Pad (방진침목패드의 방진특성에 관한 연구)

  • 황선근;엄기영;고태훈;오상덕
    • Proceedings of the KSR Conference
    • /
    • 2001.05a
    • /
    • pp.369-374
    • /
    • 2001
  • It was estimated that the anti-vibration measures at the source location of railroad are the most active and effective ones. Among CWR(Continuously Welded Rail), elastic rail fastener, floating slab, ballast mat, under sleeper pad, etc. like these various kinds of measures in the source, under sleeper pad as an anti-vibration measure was constructed at the railroad track supporting structures in the Jeon-la Line. In this study, through the field measurement of vibration at the railroad track supporting structures and nearby the ground, the vibration reduction effect of under sleeper pad were evaluated by insertion loss. As a result, vibration reduction effects were 5.0∼12.5㏈ on the concrete slab of the bridge, 3.9∼7.5㏈ on the ground nearby the bridge respectively.

  • PDF

Effect on Seal Tooth Clearance on Power Loss and Temperature of Tilting Pad Journal Bearing (씰 투스 간극이 틸팅 패드 저어널 베어링 손실과 온도에 미치는 영향)

  • Bang, Kyungbo;Choi, Yonghoon;Cho, Yongju
    • Tribology and Lubricants
    • /
    • v.34 no.5
    • /
    • pp.183-190
    • /
    • 2018
  • Tilting pad journal bearing is widely used for steam turbines because of its excellent dynamic stability. As the turbine capacity increases, power loss in the bearings becomes a matter of concern. Power loss in tilting pad journal bearings can be reduced by increasing the bearing clearance and reducing the pad arc length. In this study, the tilting pad journal bearing is tested by changing the seal tooth clearance to verify the static characteristics of the bearing. Bearing power loss and bearing metal temperature are evaluated to compare the bearing's performance and reliability for several test cases. The test bearing is a tilting pad journal bearing with 300.62mm inner diameter and 120.00mm active length. The bearing power loss, its metal temperature, and oil film thickness are measured and evaluated based on the rotor's rotational speed, oil flow rate, and bearing load. Test results show that a tilting pad journal bearing with large seal tooth clearance has 40% lower power loss compared with a bearing with a small seal tooth clearance. As the seal tooth clearance is increased, the power loss of the tilting pad journal bearing decreases. However, with respect to the bearing metal temperatures, a detuning point is observed that makes the minimum bearing metal temperature. Moreover, as the seal tooth clearance is increased, the oil film thickness increases due to high viscosity.

Characteristic of On-resistance Improvement with Gate Pad Structure (온-저항 특성 향상을 위한 게이트 패드 구조에 관한 연구)

  • Kang, Ye-Hwan;Yoo, Won-Young;Kim, Woo-Taek;Park, Tae-Su;Jung, Eun-Sik;Yang, Chang Heon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.4
    • /
    • pp.218-221
    • /
    • 2015
  • Power MOSFETs (metal oxide semiconductor field effect transistor) operate as energy control semiconductor switches. In order to reduce energy loss of the device during switch-on state, it is essential to increase its conductance. In this study we have investigated a structure to reduce the on-resistance characteristics of the MOSFET. We have a proposed MOSFET structure of active cells region buried under the gate pad. The measurement are carried out with a EDS to analyze electrical characteristics, and the proposed MOSFET are compared with the conventional MOSFET. The result of proposed MOSFET was 1.68[${\Omega}$], showing 10% improvement compared to the conventional MOSFET at 700[V].

Case Study of Building Webpage Using ActiveX Control Pad (ActiveX 콘트롤패드를 이용한 웹페이지 설계와 구현 사례)

  • 우원택
    • Proceedings of the Korea Association of Information Systems Conference
    • /
    • 2003.05a
    • /
    • pp.253-270
    • /
    • 2003
  • 본 연구는 마이크로소프트사가 개발한 ActiveX 콘트롤 기술을 이용하여 동적인 홈페이지를 제작하는 사례를 설계하고 구현 해 봄으로써 ActiveX 콘트롤의 사용가치와 이의 활용방안을 알아보고자 함에 있다. 이를 위해 첫째, 비주얼베이직과 자바를 이용한 웹프로그래밍 기술과 ActiveX 콤포넌트의 기능을 알아보고 둘째, 웹프로그래밍의 역사와 ActiveX프로그램과의 관련성과 현재 대두되고 있는 XML웹서비스기술과의 비교를 통하여 웹프로그래밍기술을 이해하고 셋째, ActiveX콘트롤 패드를 이용하여 실제로 동적홈페이지를 구성하는 사례를 설계하고 구현해 봄으로써 이의 활용가치를 알아보고자 하였다. 연구결과 자바 애플릿에 대응하는 기술로 마이크로소프트가 OLE기술을 확장하여 만든 ActiveX콘트롤은 프로그램의 재사용, 개발시간단축과 프로그램의 기능과 품질향상에 기여하여 인터넷 내지 인트라넷용 프로그램개발 등에 쉽게 이용될 수 있는 가능성을 보여 주었으나 플랫폼 독립적이지 못하고 윈도우에서만 사용 가능한 제한점을 보여주었다.

  • PDF

A Study on the Correlation between Temperature and CMP Characteristics (CMP특성과 온도의 상호관계에 관한 연구)

  • Gwon, Dae-Hui;Kim, Hyeong-Jae;Jeong, Hae-Do;Lee, Eung-Suk;Sin, Yeong-Jae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.10
    • /
    • pp.156-162
    • /
    • 2002
  • There are many factors affecting the results of CMP (Chemical Mechanical Polishing). Among them, the temperature is related to the removal rate and WIWNU (Within Wafer Non-Uniformity). In other words, the removal rate is proportional to the temperature and the variation of temperature distribution on a pad affects the non-uniformity within a wafer. In the former case, the active chemistry improves the rate of chemical reaction and the removal rate becomes better. But, there are not many advanced studies. In the latter case, a kinematical analysis between work-piece and pad can be obtained. And such result analysed from the mechanical aspect can be directly related to the temperature distribution on a pad affecting WIWNU. Meanwhile, the temperature change affects the quantities of both slurry and pad. The change of a pH value of the slurry chemistry due to a temperature variation affects the surface state of an abrasive particle and hence the agglomeration of abrasives happens above the certain temperature. And the pH alteration also affects the zeta potential of a pad surface and therefore the electrical force between pad and abrasive changes. Such results could affect the removal rate and etc. Moreover, the temperature changes the 1st and 2nd elastic moduli of a pad which are closely related to the removal rate and the WIWNU.

A Parameter Extraction Method for BJT Gummel-Poon Model (BJT Gummel-Poon 모델 파라미터 추출 방법)

  • 윤신섭;이성현
    • Proceedings of the IEEK Conference
    • /
    • 2003.07b
    • /
    • pp.763-766
    • /
    • 2003
  • A direct parameter extraction method using several two-port parameter equations derived in cutoff and active bias modes has been studied to obtain an accurate Gummel-Poon BJT model. First, dc model parameters were extracted from slopes and y-axis intercepts of I-V curve and Gummel plot. The pad capacitances and junction capacitance parameters were determined by using measured S-parameter sets in the cutoff bias. The resistance and transit time parameters were extracted by using measured S-parameter sets in the active bias.

  • PDF

회전체 진동감소를 위한 마그네틱 댐퍼 설계 및 응용

  • 이봉기;김영배
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.769-772
    • /
    • 1995
  • Most turbo machines, which operate at high speeds, such as gas turbines, jet engines, pumps, and compressors are prone to perrturbing vibrations. The best vibration control method for rotors is to eliminate destabilizing factors. Careful balancing application of "more stable" oil-lubricated bearing, such as tilting pad bearings or use of anti-swirl devices in seals, are examplse of passive vibration control methods. the use of magnetic bearing is an active control method. An obvious advantage of active control is that it provides damping (or modifies system stiffness or other parameters) only when there is a need for that, i.e., in emergency states, while not affecting the rotor normal operational conditions. Moreover, active control methods provide exact position control through on-line control. In this study, a magnetic actuator, digital contrliier using DSP, and bipolar operational power supply/amplifiers were developed to show the effectiveness of reducing robot vibration. Also the curve fitting procedure to obtain the transfer function of frequency dependent component was developed. Results presented in this dissertation will provide a well-defined technical parameters in designing magnetic damper system.er system.

  • PDF

Prognosis of Malignant Melanoma on Lower Extremity (하지에 발생한 악성 흑색종의 예후)

  • Kim, Ji Ye;Lee, Won Jai;Lew, Dae Hyun;Rah, Dong Kyun;Tark, Kwan Chul
    • Archives of Plastic Surgery
    • /
    • v.36 no.4
    • /
    • pp.411-416
    • /
    • 2009
  • Purpose: Malignant melanoma is recognized as the most serious skin cancer. We examined anatomical distribution and 5 - year survival rate of each stage of malignant melanoma on lower leg. Methods: We retrospectively analyzed the medical records of 91 patients(46 males and 45 females) with malignant melanoma on lower leg from 1985 to 2008. Age, sex, anatomical distribution and 5 - year survival rates of each stage of malignant melanoma on lower leg were investigated. Also, 5 - year survival rates of each stage and invasion depth of malignant melanoma on heel pad were investigated. Results: On lower leg, most frequently 32 cases(35.1%) occurred on heel pad, 27 cases(29.7%) occurred on dorsum of foot, 18 cases(19.8%) in toe and 14 cases(15.4%) on others in lower leg. We used the excision margin as 3 ~ 5 cm. After wide excision, in stage III, IV, the patients underwent the immunologic / chemo - therapy. The incidences of each stage were 22 cases(24.2%) in stage I, 47(51.6%) in II, 17(18.7%) in III and 5(5.5%) in IV. The 5 - year survival rates of each stage were 85%, 53.2%, 47.1% and 40%. On heel pad, the incidences of each stage were 5 cases(15.6%) in stage I, 19 cases(59.4%) in II, 7 cases(21.9%) in III and 1 case(3.1%) in IV. The 5 - year survival rates of each stage were 80%, 63.2%, 42.9% and 100%. On heel pad, incidence of local recurrence was 2 and 5 - year survival rate of this case was 100%. And systemic recurrence was 9 and 5 - year survival rate of this case was 55.6%. Conclusion: The 5 - year survival rate of malignant melanoma on heel pad was higher than previous study. To maintain the weight - bearing function of foot, we recommend the active reconstructive surgery for heel pad reconstruction after wide excision of heel pad malignant melanoma.

Field Survey on Construction and Utilization of Home Network - Focusing on Pangyo New Town - (홈네트워크 구축현황 및 이용실태 조사연구 - 판교신도시를 중심으로 -)

  • Yim, Mi-Sook
    • Journal of the Korean housing association
    • /
    • v.27 no.5
    • /
    • pp.25-35
    • /
    • 2016
  • he objective of this study was to investigate home network systems presently applied in multi-housing complexes and resident's usage to improve the utilization of these systems and services as well as maintenance methods. Subjects were 27 housing complexes equipped with home network systems in west Pangyo area. The investigation methods of communal network systems were observed and photographed. Unit systems were investigated through photography, interviews, and observation focusing on the utilization of Wall-Pads by visiting one unit of each housing complex. The results are as follows: (1) Most housing complexes that we investigated were built with high-grade IT infrastructure. Also, remote meter reading, electronic security, vehicle access, and building access systems were established. Wall-Pads with similar functions were installed in 23 housing complexes, excluding private rental housing complexes. (2) Even though people were well aware of the need for common systems within their housing complexes, only 10~20% of Wall-Pad menus were used. (3) Low utilization rates of home network stem from Wall-Pad menus which were user-unfriendly, and a lack of user training for the complex's common system and unit system. Therefore, to promote active use of home network systems, the systems must be diversified in accordance with user characteristics. In addition, the Wall-Pad menus should be reorganized to be user-friendly.

Improvement of the Light Emission Efficiency on Nonpolar a-plane GaN LEDs with SiO2 Current Blocking Layer (무분극 a-plane 질화물계 발광다이오드에서 SiO2 전류 제한 층을 통한 발광 효율 증가)

  • Hwang, Seong Joo;Kwak, Joon Seop
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.3
    • /
    • pp.175-179
    • /
    • 2017
  • In this study, we investigate the $SiO_2$ current blocking layer (CBL) to improve light output power efficiency in nonpolar a-plane (11-20) GaN LEDs on a r-plane sapphire substrate. The $SiO_2$ CBL was produced under the p-pad layer using plasma enhanced chemical vapor deposition (PECVD). The results show that nonpolar GaN LED light output power with the $SiO_2$ CBL is considerably enhanced compared without the $SiO_2$ CBL. This can be attributed to reduced light absorption at the p-pad due to current blocking to the active layer by the $SiO_2$ CBL.