• Title/Summary/Keyword: Active house

Search Result 191, Processing Time 0.03 seconds

The Study on the Zero-Energy House Prototype of Country House (농촌주택에 적합한 제로에너지 하우스의 프로토타입 연구)

  • Im, Kyung-Up;Kim, Bich-Na;Lee, Chul-Sung;Yoon, Jong-Ho;Jin, Kyeong-Il
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.185-190
    • /
    • 2009
  • Due to the building energy consumption of total energy consumption of Korea takes over 24%, economizing building energy and using renewable energy resources is being required. To suggest the prototype of zero energy house of country house, the passive systems and active systems are applicated and simulated. In case of wall insulation system is applicated, the heating load of building is reduced. Also, clear triple pair glazing system reduced 2.1% of heating load of building. The amount of reducing heating load by infiltration is depending on the Heating system. In this model, the 0.3ACH made 14.6% saving on heating load from base infiltration 0.82ACH. The solar thermal system of active system could save 80% of DHW and PV system supplies electric power more than average consumption of year. Through the optimum process, the end use of zero energy house of country house is 36kWh/m2.yr and total energy consumption is reduced about 74.2%.

  • PDF

The Study Of Optimum Method About The Architecture, Construction, And Maintenance Through The Construction Of Zero Energy House (제로 에너지 하우스 구축을 통한 설계, 시공, 유지관리 최적 방안에 관한 연구 및 제안)

  • Kim, Sun-Geun;Kwon, Soon-Wook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.11
    • /
    • pp.42-50
    • /
    • 2014
  • In the thesis, the case of zero energy house construction applied with various Active factors and Passive factors which is the real residence as a standard not a normal experimental residence was evaluated, analyzed, and organized. The thesis can be the base data to construct another similar case of zero energy house.

The Study on Activity Star Problem and Optimum Construction Method Through the Defect Case of Zero Energy House in the Existing Building (기축건물의 제로에너지 하우스 하자 사례를 통한 공종별 문제점 및 최적구축 방안에 관한 연구)

  • Kim, Sun-Geun;Kwon, Soon-Wook
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.4
    • /
    • pp.262-270
    • /
    • 2015
  • In this paper existing buildings, not a new buildings and house for living people not just a displaying and a viewing, created by the imagine effect or virtual simulation was applied various Active and Passive elements. After constructing zero-energy houses, through default case happened during operation period it is described problems and solutions about field part, work classification, installation by Location part, and Installation equipment part. Since then, to take advantage of this thesis, it's the purpose of this paper using as the baseline data for building a zero-energy house in another similar case.

Active Solar Heating System Design and Analysis for the Zero Energy Solar House (제로에너지 솔라하우스의 난방/급탕용 태양열 시스템 설계 및 분석)

  • Baek, N.C.;Yoo, C.K.;Yoon, E.S.;Yoo, J.Y.;Yoon, J.H.
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.4
    • /
    • pp.1-9
    • /
    • 2002
  • This study is on the design and evaluation of Zero Energy Solar House(ZeSH) including active solar heating system. Various innovative technologies such as super insulation, passive solar systems, super window, ventilation heat recovery system...etc were analyzed by individual and combination for the success of ZeSH. The ESP-r simulation program was used for this. Simulation results shows that almost 77% of heating load can be reduced with the following configuration of 200mm super insulation, super windows, passive solar system and 0.3 ventilation rate per hour. Active solar heating system (ASHS) was designed for the rest of the heating load including hot water heating load. The solar assisted heat pump is used for the auxiliary heating device in order to use air conditioner but not included in this study. The yearly solar fraction is 87% with a solar collector area of $28m^2$. The parametric studies as the influence of storage volume and collector area on the solar fraction was analyzed.

A Study on the Problems of the Occupants on the Purchasing Housing (住宅 取得시 發生하는 消費者 問題와 對應行動에 관한 硏究)

  • Cho, Hyeon-Kyeong;Kang, Soon-Joo
    • Journal of Families and Better Life
    • /
    • v.10 no.1 s.19
    • /
    • pp.139-156
    • /
    • 1992
  • The purpose of this study is to provide basic data for the solution of occupant problems related to the house purchasing. For the purpose, the content of problems and actual conditions of house purchasing are examined. Also the structural analysis of occupant's evaluation of housing purchasing is executed. For these purposes, a survey was conducted using questionnaires. Data analysis was conducted from 263 house owners in Seoul. Major findings of this study can be summarized as follows ; 1) The frequency and the contend of occupation's problems with house purchasing are studied. The rate of housing problem occurrence is 71.2%, so the majority of respondents experience problems. The most common problems are the difference from supplier's description(53.2%). The rate of housing problems occurrence is qenerally high with the houses of mult-housedhold houses and mult-family houses type. 2) There is a significant difference in housing satisfaction extend according to the existence of an housing problem experience. Therefore, it can be inferred that experience of housing problem has an important effects upon the housing satasfaction extent. 3) Occupants' countermoves to the housing problems are examined. Occupants make active regotiation with house suppliers only on the direct damages such as an economical loss or a living difficulty. However, they usually make no countermove at all on the other indirect troubles. House suppliers make correction only when occupants' countermove actively, but refuse to do when occupant's reactions are not active. 4) As a means of countermove, most occupants depend on direct personal regotiation with house suppliers. The rate of using a specialist or public and private consultant is extremely low. 5) Problems with house purchasing and the countermove process of both occupant and house supplier are displayed in the figure(Fig. 4-4).

  • PDF

Design Checklist for Self-sufficient Zero Energy Solar House(ZeSH) (에너지자립형 태양열 주택의 설계 및 시공 방법 체크리스트 수립 연구)

  • Yoon Jongho;Baek Namchoon;Yu Changkyun;Kim Jongil
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.416-421
    • /
    • 2005
  • Most of solar system dissemination has been focused on domestic hot water system of which utilization to a building is relatively simple and safe than solar heating system. Through the survey on a cause of solar house dissemination failure in Korea, we conclude that design integration and systematic approach method for technology application are the most important element for a successful solar house. KIER(Korea Institute of Energy Research) and Hanbat National University have started new project on a development of Zero energy Solar House, called ZeSH which can be sustained just by natural energy without the support of existing fossil fuel. This is the 1st phase research of 10 years long-term ZeSH plan which develops a low-cost and $100\%$ self sufficient ZeSH. The goal of 1st phase ZeSH research is to get a $70\%$ self sufficiency only in thermal loads. Actual demonstration house, named KIER ZeSH I was designed and constructed as a result of 1st phase research work in the end of 2002. Various innovative technologies such as super insulation, high performance window, passive and active solar systems, ventilation heat recovery system are applied and evaluated to the KIER ZeSH I. A lot of computer simulations had been conducted for the optimal design and system integration in every design steps. Considering all the results from detailed hourly computer simulation, it is expected that at least $70\%$ self-sufficiency in thermal loads which is 1st phase target value can be excessively achieved in actual demonstration house. Besides, many valuable findings from the design and analysis to construction could be established such as collaboration method among the participants, practical design and construction techniques for system integration and the others. The purpose of this paper is to introduce the main findings through the development of KIER ZeSH I project. Practical guidelines in every design step for new low- or zero- energy solar house is proposed as result.

  • PDF

A Study on the Space Programming by Considering Leisure Activity for Middle-aged in the House (예비 노인층의 주거 내 여가활동을 고려한 공간구성 계획에 관한 연구)

  • Kim, Jung-Yoon;Lee, Hyun-Soo
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2006.11a
    • /
    • pp.163-167
    • /
    • 2006
  • The purpose of this study is to find out the leisure activity for middle-aged from 45-65 living in the house. The survey had been conducted in 135 respondents with Questionnaire during September 25th to October 7th, 2006. Frequency, Cluster Analysis and Cross tabulation were obtained from the data using SPSS program. The Questionnaire consists of leisure activity and leisure location based on 3 properties of leisure. The results of this study are as follows. First, frequency the respondents is differed by demographic characteristics. Those who have higher level of education, subjective economic power and are younger were more active. Second, the leisure activity in the house is higher in passive on 1st, intellectual and emotional on 2nd, mass media and social activity on 3rd property. Respondents regard home as not a active space but a relax space. Third, the most preferred location in the house for leisure is living-room. Next, master-room and dinning-kichen are. Because of women who spend time more than men in living. Therefore, designing living space for elderly is considered various leisure type of residents.

  • PDF

A Study on the Energy Performance Evaluation of Zero Energy House in Zero Energy Town (제로에너지타운 내 주택 에너지 성능 평가에 관한 연구)

  • Lee, Wang-Je;Baek, Nam-Choon;Lee, Kyoung-Ho;Heo, Jae-Hyeok
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.2
    • /
    • pp.85-91
    • /
    • 2015
  • In this study, energy performance analysis of houses in zero energy demonstration town(ZeT) was carried out using the monitoring results. This ZeT was composed 29 zero energy individual houses(ZeH) which were applied passive as well as active technologies. The results are as follows. (1) Residents are generally considered to have been lacking basic mind to save energy, (2) In particular, average yearly total energy consumption per house is 12,834 kWh and specific heating energy is $53.2kWh/m^2{\cdot}yr$ which is higher than that of passive house. This is because of one of the reason just pointed out in subsection (1). (3) Most part of the residual energy load are supplied with only renewable energy, but not operating energy for geothermal heat pump which is use of cheap electricity.

Repellent effect of Eucalyptus essential oils against house dust mites (Dermatophagoides farinae and D. pteronyssinus) (집 먼지진드기에 대한 유칼립투스정유의 기피효과)

  • Lee, Jae-Young;Jee, Cha-Ho
    • Korean Journal of Veterinary Service
    • /
    • v.33 no.2
    • /
    • pp.167-171
    • /
    • 2010
  • Majority of asthma and atopic dermatitis are known to be spontaneously sensitive to house dust mite allergen. Control of house dust mite populations has been principally achieved by using chemical insecticides. But the risk to human health would be a potential problem. Moreover, house dust mite remain as allergens even after death. So, It is more effective method keeping the house dust mites away than killing them. The use of plant-derived repellents has been considered as a promising alternative to chemical repellents. Eucalyptus is a diverse genus of flowering trees in the myrtle family, Myrtaceae. It has insect repellent properties and is an active ingredient in some commercial mosquito repellents. These studies were carried out to investigate repellent effects of Eucalyptus oil against house dust mites and compare lemongrass oil. Eucalyptus oil and lemongrass oil were exposed at different doses (0.2, 0.1, 0.05, 0.025, 0.0125, $0.00625{\mu}l/cm^2$) and different times (1, 3, 6 hours) on house dust mites. The most effective dose of Eucalyptus and lemongrass oils against house dust mites was $0.1{\mu}l/cm^2$ and $0.025{\mu}l/cm^2$. Each repellent effect(%) in most effective dose was 90.3% (Eucalyptus) and 80.8% (lemongrass).

Applicability of Interaction Design at Main Entrance in Apartment House (공동주택 주동출입구의 인터랙션 디자인 적용가능성)

  • Park, Mi-So;Kang, Soon-Joo
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.04a
    • /
    • pp.319-322
    • /
    • 2008
  • Designing of the apartment house in present has been contributing to private unit reflected demands and characteristics of residents. However, common space hasn't been designed in various ways compared to unit. Though the main entrance is place to link inner space and out space, to make resident identity and to communicate with neighbors, It has been produced the same type. The space design in 21st century is focusing on contents of space with the development of techniques, and we need to find applicability of new design related to digital technology in apartment house. The purpose of this study is to find applicability of interaction design at main entrance in apartment house for improvement functions of entrance. The results of this study were as follows; The main entrance is possible more active place through the interaction design that would be satisfied with residents needs and functions.

  • PDF