• Title/Summary/Keyword: Active Protection

Search Result 597, Processing Time 0.025 seconds

Development of Smart Sensor for Diagnosis/Monitoring of Concrete Structure (콘크리트 구조물 진단/감시용 스마트센서 개발)

  • Yun Dong-Jin;Lee Young-Sup;Lee Sang-Il;Kwon Jae-Hwa
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.21-28
    • /
    • 2006
  • Structural health monitoring (SHM) is a new technology that will be increasingly applied at the industrial field as a potential approach to improve cost and convenience of structural inspection. Recently, the development of smart sensor is very active for real application. This study has focused on preparation and application study of SAL sensor. In order to detect elastic wave, smart piezoelectric sensor, SAL, is fabricated by using a piezoelectric element, shielding layer and protection layer. This protection layer plays an important role in a patched network of distributed piezoelectric sensor and shielding treatment. Four types of SAL sensor are designed/prepared/tested, and these details will be discussed in the paper. In this study, SAL sensor can be feasibly applied to perform structural health monitoring and to detect damage sources which result in elastic waves.

  • PDF

Design Verification of ECS Condenser Icing Protection System by Flight Test of T-50 Advanced Trainer (T-50 비행시험을 통한 환경제어계통 콘덴서 빙결방지 설계 검증)

  • Nam, Yong-Seog;Kim, Yeonhi;Song, Seok-Bong;Seo, Dong-Yun;Son, Won-Ik;Park, Sung-Soon
    • Journal of Aerospace System Engineering
    • /
    • v.2 no.3
    • /
    • pp.40-44
    • /
    • 2008
  • T-50 ECS(environment control system) was designed to have freezing protection for the condenser. However during the ground and flight test, the freezing problem was occurred. This paper deals with the analysis of the freezing problem and introduces anti-freezing design using ADI(Active De-Icing) logic to solve the condenser freezing problem of T-50 ECS

  • PDF

The undeniable digital multisignature scheme suitable for joint copyright protection on digital contents (온라인 디지털 콘텐츠 공동 저작권 보호에 적합한 부인봉쇄 디지털 다중서명 기법)

  • 윤성현;한군희
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2004.05a
    • /
    • pp.261-267
    • /
    • 2004
  • In undeniable digital signature scheme, the signature can not be verified without the signer's cooperation. The undeniable signature scheme can be used to computerize many applications which can not be done by a conventional digital signature scheme. In this study, we propose the undeniable digital multi-signature scheme which requires many signers and designated verifier. The multi-signature can be verified only in cooperation with all signers. The proposed scheme satisfies undeniable property and it is secure against active attacks such as modification and denial of the multi-signature by signers. We also discuss practical applications such as joint copyright protection on digital contents.

  • PDF

Coexistence between Wireless Fidelity and Wireless Microphone in TV Band

  • Cho, In-Kyoung;Lee, Il-Kyoo;Cho, Ju-Phil
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.6 no.3
    • /
    • pp.906-918
    • /
    • 2012
  • Wireless Fidelity (WiFi) and Wireless microphone are assumed to operate on adjacent channels in TV White Spaces(TVWS). The Scenario of WiFi potentially interfering with Wireless microphone is analyzed through Minimum Coupling Loss (MCL) and Spectrum Engineering Advanced Monte Carlo Analysis Tool (SEAMCAT) based on the Monte-Carlo simulation method. In the case of single WiFi interfering with Wireless microphone, the protection distance between WiFi and the Wireless microphone should be at least 25.12 m to avoid WiFi impact on Wireless microphone. When the active number of WiFi is 12, the guard band between WiFi and Wireless microphone should not be less than 4.97 MHz to guarantee that WiFi does not interfere with the Wireless microphone.

IR 불꽃화재감지기 개발

  • Gwon, O-Seung;Lee, Bok-Yeong;Park, Sang-Tae
    • Fire Protection Technology
    • /
    • s.29
    • /
    • pp.39-45
    • /
    • 2000
  • All objects emit thermal radiation and this radiation is the basis of the techniques used to detect flames. The usual phenomena occurring in the initial stage of a fire are generally invisible products of a combustion and visible smoke. Liquid or gaseous materials do not undergo a smoldering stage such fires develop very rapidly. Also, the heat generated by the initial flames is usually not sufficient to active a heat detector. In this case the most effective criterion for automatic fire detection is the flame. In fire regulation of korea, the compulsory standard provided that a flame detector shall be installed a place of the attachment hight of detector is higher than 20 m, chemical plants, hangar, refinery, etc.. The result of the research and development are discriminated between a flame and other radiant emitters, developed PZT pyroelectric element is based on the use of photo-voltanic cell, developed IR band-pass filter that only allow a 4.3 radiation wavelength to reach the sensors and developed IR flame detector.

  • PDF

Study on building room fire development stages (건축물 실내화재의 단계에 대한 연구)

  • Cha, Jong-Ho
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.169-172
    • /
    • 2008
  • The purpose of this paper is to summarize characteristics of fire growth stages, combustion proceeding, human behavior factors against fire, fire active protections, fire alarms in order to perform public safety and protection, personnel property protection, with identification of economic analysis aspects based on respective stages classified as fire generation- fire growth- flashover- fire extinction, which is differ from previous studies that based on distinct concepts such as fire stages, escapes, building construction, fire sensing.

  • PDF

Application of Oral Absorption in Establishment of AOEL for Pesticides and Occupational Risk Assessment for farm worker (경구흡수율을 반영한 농약의 AOEL 설정 및 농작업자 위해성 평가)

  • You, Are-Sun;Hong, Soonsung;Lee, Je Bong;Lee, Seungdon;Ihm, Yangbin
    • The Korean Journal of Pesticide Science
    • /
    • v.18 no.4
    • /
    • pp.342-349
    • /
    • 2014
  • Methods of establishment of AOEL (Acceptable Operator Exposure Level), application of oral absorption by country, and calculation of exposure dose for operator risk assessment in USA, EU and Korea were investigated. Oral absorption of 141 active substances for pesticides was also investigated, then operator risk assessment was conducted with AOEL including oral absorption and Korean AOEL. Internal dose converted to external dose with oral or dermal absorption in USA and EU, but external dose to which oral absorption was not applied was used for establishment of AOEL in Korea. Oral absorption of 50 active substances among 141 were below 80%. In case of application of oral absorption as a correction factor in below 80%, AOELs of about 36% active substances were considered to be lower than the current Korean AOELs. Operator risk assessment of 28 active substances among 50 active substances with oral absorption below 80% was conducted with EU AOELs. TER (Toxicity Exposure Ratio) of 12 plant protection products including chlorothalonil WG (Water-dispersible Granule) was less than 1 and the risk was high. Operator risk assessment of 24 active substances among 50 active substances with oral absorption below 80% was conducted with Korean AOELs. TER of 6 plant protection products including chlorothalonil WG were less than 1 and the risk was high. Operator risk assessment of 4 plant protection products not having Korean AOEL was conducted with converted EU AOEL into AOEL not including oral absorption. The results indicated TER of 4 products including daminozide WP (Wettable Powder) was over 1 and risk was low. 22 products except 6 products such as oxadiagyl SC (Suspension Concentration) were shown the same results of risk assessment between EU AOELs and Korean AOELs. As a result, it was considered that AOELs including oral absorption was possible to be used for operator risk assessment. It was considered operator risk assessment with AOEL including oral absorption was more like real assessment method, and improvement of assessment was needed for application to evaluate pesticides in registration.

The Undeniable Digital Multi-signature Scheme Suitable for Joint Copyright Protection on Digital Contents (디지털 콘텐츠 공동 저작권 보호에 적합한 부인봉쇄 디지털 다중서명 기법)

  • Yun Sung-Hyun
    • The Journal of the Korea Contents Association
    • /
    • v.5 no.1
    • /
    • pp.55-63
    • /
    • 2005
  • In undeniable digital signature scheme, the signature can not be verified without the signer's cooperation. The undeniable signature scheme can be used to computerize many applications which can not be done by a conventional digital signature scheme. In this study, we propose the undeniable digital multi-signature scheme which requires many signers and designated verifier The multi-signature can be verified only in cooperation with all signers. The proposed scheme satisfies undeniable property and it is secure against active attacks such as modification and denial of the multi-signature by signers. We also propose copyright protection method of co-authored digital contents as an application of the proposed scheme.

  • PDF

Research for Protection Relay of Static Condenser Bank (SC 전용 보호계전기 개발)

  • Jeong, J.K.;Yun, S.Y.;Kim, S.J.;Kim, K.G.
    • Proceedings of the KIEE Conference
    • /
    • 2006.05a
    • /
    • pp.48-50
    • /
    • 2006
  • SC(Static Condenser) in KEPCO is used in voltage control and power factor compensation. Currently KEPCO uses SC to 154kv 50MVA and 23kv SMVA. It is not important in old days because a SC bank accident has no effect on power system. But we are interested in the SC bank for power quality in these days. The SC Bank has a reactor and a condenser using series connection. It is operated in critical point for resonance circuit normally. Therefore the SC bank has a small reliability against other Power instruments. If a 4th harmonic frequency as a resonance frequency is supplied in system, the condenser is damaged because of a resonance current. And a trip and a closing for CB(Circuit Breaker) in many times will have a big influence of SC bank destruction. General OCR(Over Current Relay) observing SC bank is not useful for this protection We think that protection relay must be have the SC bank characteristics. A solution for this problem is active Power, resonance frequency and impedance.

  • PDF

A Study on the Fire-Safety Design for the Historic Buildings (역사적 건조물의 화재안전을 위한 기초연구)

  • Lee Ji-Hee
    • Journal of the Korean housing association
    • /
    • v.15 no.6
    • /
    • pp.107-113
    • /
    • 2004
  • Fire was and remains a great threat to historic buildings of wood. This threat is omnipresent and often results to irreparable property losses especially cultural heritages. Fire of historic buildings continues to increase every year. The purpose of this study is to preserve a life safety, historical heritage and architectural & cultural values by pursuing for fire safety in the historical buildings. This study shall employ two research methods: a literature review and field survey methods. The literature review shall focus on the observations of characteristics noted in fire codes. The field survey shall cover a heat analysis and fire protection equipment. A method is proposed to investigate fire codes related historical building, reported fire history Fire Codes and Regulations for modern buildings are not always applicable on the historic buildings. Old buildings, and some new buildings with architectural, historical or cultural importance may have values which cannot be measured on a monetary scale. Their protection against the damage caused by fire is considered to be one of the basic moral duties of society. It is strongly recommended, therefore, legislation for fire safety in historical buildings must be extended to a complementary relationship with 'active' fire protection measures, to provide safety in real historical building in real fire situations. The development and application of performance based Codes and the Fire Safety Engineering approach seems to be a rather reasonable and effective way to deal with this historical buildings.