• Title/Summary/Keyword: Active Power Control

Search Result 1,399, Processing Time 0.028 seconds

An Over Current Protection Scheme for Hybrid Active Power filter

  • Lee Woo-Cheol;Chae Beom-Seok;Hyun Dong-Seok;Lee Taeck-Kie
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.571-575
    • /
    • 2001
  • A protection scheme for hybrid active power filters, which is combined shunt passive filter and small rated series active filter, is presented and analyzed in this paper. The proposed series active power filter operated as a high impedance 'k($\Omega$)' to the fundamental component when over current occurs in the power distribution system, and three control strategies are proposed in this paper. The first is the method by detecting the fundamental source current through the p-q theory, the second is the method by detecting the fundamental component of load current in Synchronous Reference Frame (SRF) and the third is the method by detecting the input voltage. When the over current occurs in the power distribution system, the proposed scheme protects the series active power filter without additional protection circuits. The validity of proposed protection scheme is investigated through experimental result for the prototype hybrid active power filter system.

  • PDF

DC-Link Voltage Balance Control in Three-phase Four-wire Active Power Filters

  • Wang, Yu;Guan, Yuanpeng;Xie, Yunxiang;Liu, Xiang
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1928-1938
    • /
    • 2016
  • The three-phase four-wire shunt active power filter (APF) is an effective method to solve the harmonic problem in three-phase four-wire power systems. In addition, it has two possible topologies, a four-leg inverter and a three-leg inverter with a split-capacitor. There are some studies investigating DC-link voltage control in three-phase four-wire APFs. However, when compared to the four-leg inverter topology, maintaining the balance between the DC-link upper and lower capacitor voltages becomes a unique problem in the three-leg inverter with a split-capacitor topology, and previous studies seldom pay attention to this fact. In this paper, the influence of the balance between the two DC-link voltages on the compensation performance, and the influence of the voltage balance controller on the compensation performance, are analyzed. To achieve the balance between the two DC-link capacitor voltages, and to avoid the adverse effect the voltage balance controller has on the APF compensation performance, a new DC-link voltage balance control strategy for the three-phase four-wire split-capacitor APF is proposed. Representative simulation and experimental results are presented to verify the analysis and the proposed DC-link voltage balance control strategy.

Power Decoupled Multi-Port Dual-Active-Bridge Converter Employing Multiple Transformers for DC Distribution Applications (복수의 변압기를 사용하여 독립 전력제어가 가능한 DC 배전용 다중포트 Dual-Active-Bridge 컨버터)

  • Kim, Inhyeok;Sim, Ju-Young;Lee, Jun-Young;Jung, Jee-Hoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.4
    • /
    • pp.286-292
    • /
    • 2020
  • This study proposes a power decoupled multi-port dual-active-bridge (DAB) DC-DC converter employing multiple transformers. Conventional multiport DAB DC-DC converters experience a power coupling issue from the use of a single transformer, which essentially requires complex power decoupling control. To solve this issue, a multiport DAB DC-DC converter employing multiple transformers is proposed to decouple output power without additional complex control algorithms. The proposed converter uses multiple transformers that can expand output ports easily. Therefore, transformers and the proposed multi-port DAB converter can be designed simply. In addition, the number of coupling inductors can be reduced in the proposed three-port DAB converter compared with that in conventional multiport DAB converters. The power decoupling characteristics and equivalent circuit of the proposed converter are analyzed using theoretical model approaches. Finally, a 3-kW laboratory prototype is developed to verify the effectiveness of the proposed converter.

3-Phase 4-Wire Series Active Power Filter System for Harmonics and Unbalanced Loads (고조파와 부하불평형에 대한 3상4선식 직렬형 능동전력필터 시스템)

  • Ko Soo-Hyun;Han Yoon-Seok;Kim Young-Seok
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.603-606
    • /
    • 2002
  • This paper introduces a control algorithm for 3-phase 4-wire series active power filter This control algorithm compensates harmonics and neutral line currents which are generated by balanced or unbalanced nonlinear loads. The advantage of this control algorithm is direct extraction of compensation voltage references. Therefor calculation time is shorten and the performance of series active power filter is improved. Compensation principle of the proposed control algorithm is presented in detail. Experimental results are shown to verify the effectiveness of tile proposed control algorithm.

  • PDF

A Novel Series Active Power Filter for Harmonic Reduction of 3-Phase 3-Wire/4-Wire System (3상 3선/4선식 전력계통의 고조파 저감을 위한 새로운 직렬형 능동 필터 시스템)

  • Kim, Myoung-Hyun;Lim, Seung-Won;Han, Yoon-Seok;Kim, Young-Seok;Won, Chung-Yuen;Choi, Se-Wan
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.349-351
    • /
    • 1999
  • This paper presents a new control algorithm for series active power filters that are applied to 3-phase 3-wire and 3-phase 4-wire systems with capacitive loads. It is difficult to reduce harmonic currents in neutral lines of the 3-phase 4-wire systems using conventional series active power filter control methods. 3-phase 4-wire series active power filter systems using the proposed method in this study lower neutral line harmonics. Simulation was carried out to verify the algorithm.

  • PDF

A New Control Method of Series Single-Phase Hybrid Active Power Filter (직렬형 단상 하이브리드 능동 전력필터의 새로운 제어법)

  • Kim, Jin-Sun;Kim, Young-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2005.04a
    • /
    • pp.149-151
    • /
    • 2005
  • This paper deals with the novel control algorithm of single-phase hybrid active power filter for the compensation of harmonic current components in nonlinear R-L load with passive active power filters. To construct two-axes coordinate, an imaginary second phase was made by giving time delay to line current. In this proposed method, the new signal, which was the delayed through the filtering by the phase-delay property of low-pass filter, is used as the secondary phase. Because two phases have different phase, instantaneous calculation of harmonic current is possible. In this paper, a reference voltage is created by multiplying gain of filter by compensation current using the rotating reference frames that synchronizes with source-frequency, not applying to instantaneous reactive power theory which has been used with the existing fixed reference frames. This paper shows the experimental results, which provide a high accuracy and extremely fast response of single-phase hybrid active Bower filter under the operation with the proposed control method.

  • PDF

Parallel Control of Shunt Active Power Filters in Capacity Proportion Frequency Allocation Mode

  • Zhang, Shuquan;Dai, Ke;Xie, Bin;Kang, Yong
    • Journal of Power Electronics
    • /
    • v.10 no.4
    • /
    • pp.419-427
    • /
    • 2010
  • A parallel control strategy in capacity proportion frequency allocation mode for shunt active power filters (APFs) is proposed to overcome some of the difficulties in high power applications. To improve the compensation accuracy and overall system stability, an improved selective harmonic current control based on multiple synchronous rotating reference coordinates is presented in a single APF unit, which approximately implements zero steady-state error compensation. The combined decoupling strategy is proposed and theoretically analyzed to simplify selective harmonic current control. Improved selective harmonic current control forms the basis for multi-APF parallel operation. Therefore, a parallel control strategy is proposed to realize a proper optimization so that the APFs with a larger capacity compensate more harmonic current and the ones with a smaller capacity compensate less harmonic current, which is very practical for accurate harmonic current compensation and stable grid operation in high power applications. This is verified by experimental results. The total harmonic distortion (THD) is reduced from 29% to 2.7% for a typical uncontrolled rectifier load with a resistor and an inductor in a laboratory platform.

Power Factor with Single Power Stage AC/DC Converter Operated in Active-Clamp Mode (능동 클램프 모드로 동작하는 단일 전력 AC/DC 컨버터에 의한 역률개선)

  • Yoon, Shin-Yong;Baek, Hyun-Soo;Kim, Yong;Kim, Cherl-Jin;Eo, Chang-Jin
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.8
    • /
    • pp.392-401
    • /
    • 2001
  • This paper presents the single-stage high power factor AC to DC converter operated in active-clamp mode. The proposed converter is added active-clamping circuit to boost-flyback single-stage power factor corrected power supply. The active-clamping circuit limits voltage spikes, recycles the energy trapped in the leakage inductance, and provides a mechanism for achieving soft switching of the electronic switches to reduce the switching loss. The auxiliary switch of active-clamping circuit uses the same control and driver circuit as the main switch to reduce the additional cost and size. To verify the performance of the proposed converter, a 100W converter has been designed. The proposed converter gives good power factor correction, low line current harmonic distortions, and tight output voltage regulation, as used unity power factor.

  • PDF

Active Frequency Drift Method for Islanding Detection Applied to Micro-inverter with Uncontrollable Reactive Power

  • Kwak, Raeho;Lee, June-Hee;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1918-1927
    • /
    • 2016
  • This paper proposes active frequency drift (AFD) as an anti-islanding method applied to micro-inverters with uncontrollable reactive power. When using ordinary inverter topologies, such as full bridge inverters in photovoltaic systems, the islanding phenomenon can be detected with reactive power-based methods, such as reactive power variation. However, when the inverter topology cannot control the reactive power, conventional anti-islanding methods with reactive power cannot be utilized. In this work, the topology used in this paper cannot control the reactive power. Thus, an anti-islanding method that can be used in topologies that cannot control the reactive power is proposed. The conventional anti-islanding method of the topology that cannot control reactive power is introduced and analyzed. Unlike the conventional AFD method, the proposed method extends a zero current interval every predetermined cycle. The proposed method offers certain advantages over conventional AFD methods, such as total harmonic distortion. The proposed method is validated through simulation and experiment.

Deadbeat Control with a Repetitive Predictor for Three-Level Active Power Filters

  • He, Yingjie;Liu, Jinjun;Tang, Jian;Wang, Zhaoan;Zou, Yunping
    • Journal of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.583-590
    • /
    • 2011
  • Three-level NPC inverters have been put into practical use for years especially in high voltage high power grids. This paper researches three-level active power filters (APFs). In this paper a mathematical model in the d-q coordinates is presented for 3-phase 3-wire NPC APFs. The deadbeat control scheme is obtained by using state equations. Canceling the delay of one sampling period and providing the predictive value of the harmonic current is a key problem of the deadbeat control. Based on this deadbeat control, the predictive output current value is obtained by the state observer. The delay of one sampling period is remedied in this digital control system by the state observer. The predictive harmonic command current value is obtained by the repetitive predictor synchronously. The repetitive predictor can achieve a better prediction of the harmonic current with the same sampling frequency, thus improving the overall performance of the system. The experiment results indicate that the steady-state accuracy and the dynamic response are both satisfying when the proposed control scheme is implemented.