• Title/Summary/Keyword: Active Period

검색결과 1,578건 처리시간 0.028초

2분할 전류유입 공진 회로를 이용한 PFC회로의 설계 (Design of the Circuit for a Power Factor Correction using the Two-Input Current Resonant)

  • 장우신;고강훈;서기영;이현우;곽동걸
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.233-235
    • /
    • 2001
  • On the active filter converter for power factor correction is used inverter for a air-conditioner's power supply to meet IEC standard In the active filter topology for power factor correction, extra switch only control the input current indirectly to satisfied with the IEC standard for reducing the cost and size. In this paper, by dividing the input current into two different modes, the current conduction period can be widened and harmonics can largely be canceled between the two modes. Hence, the harmonics characteristics can be significantly improved, whereby the lower order harmonics, such as the fifth and seventh orders, are much reduced. The results are confirmed by theoretical and experimental implementations.

  • PDF

Internet Traffic Control Using Dynamic Neural Networks

  • Cho, Hyun-Cheol;Fadali, M. Sami;Lee, Kwon-Soon
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권2호
    • /
    • pp.285-291
    • /
    • 2008
  • Active Queue Management(AQM) has been widely used for congestion avoidance in Transmission Control Protocol(TCP) networks. Although numerous AQM schemes have been proposed to regulate a queue size close to a reference level, most of them are incapable of adequately adapting to TCP network dynamics due to TCP's non-linearity and time-varying stochastic properties. To alleviate these problems, we introduce an AQM technique based on a dynamic neural network using the Back-Propagation(BP) algorithm. The dynamic neural network is designed to perform as a robust adaptive feedback controller for TCP dynamics after an adequate training period. We evaluate the performances of the proposed neural network AQM approach using simulation experiments. The proposed approach yields superior performance with faster transient time, larger throughput, and higher link utilization compared to two existing schemes: Random Early Detection(RED) and Proportional-Integral(PI)-based AQM. The neural AQM outperformed PI control and RED, especially in transient state and TCP dynamics variation.

단일 전류 센서를 사용한 3상 PWM 정류기의 새로운 제어 (A New Control of Three-Phase PWM Rectifier with Single Current Sensor)

  • 이우철;현동석;이택기
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권8호
    • /
    • pp.440-447
    • /
    • 1999
  • This paper proposes a control method for three-phase PWM rectifier with only single current sensor in DC link side. A PWM modulation strategy for reconstructing three phase currents from the DC link current is given. The states of the retifier switch are modified so that all phase currents can be reconstructed in a switching period although one or two of active vectors is applied only for a short time. Therefore, a new current control using an adjustment scheme of the modulation signal for three-phase PWM rectifier will be discussed, and verified the experimental results.

  • PDF

저전력 멀티미디어 재생 기법 (PoMP : Power conscious Multimedia Player)

  • Park, Jung-Wan;Won, You-Jip
    • 한국정보과학회:학술대회논문집
    • /
    • 한국정보과학회 2003년도 봄 학술발표논문집 Vol.30 No.1 (C)
    • /
    • pp.253-255
    • /
    • 2003
  • Electricity is the prime commodity in mobile device, e.g. smart phone, PDA, MP3 player and etc. This strict restriction on power consumption requirement of the mobile device puts unique demand in designing hardware and software components of the device. In this paper, we address the issue of minimizing the power consumption in retrieving the continuous media data from the disk drive for real-time playback purpose. Different from the legacy text based data, real-time multimedia playback requires that the storage supplies the data block continuous fashion. This may put immense burden on the power scarce environment since the disk Is required to be active for the entire playback duration. We develop elaborate algorithm which carefully analyzes the power consumption profile of the disk drive and which establishes the data retrieval schedule for the given playback. It computes the amount of data blocks to read, the length of active and standby period. According to our simulation result, the ARM algorithm exhibits superior performance in continuous media retrieval from the aspect of power consumption to legacy playback scheme.

  • PDF

On the Passive type Anti-Rolling Tank and its Activation by Air Blower

  • Lew, Jae-Moon;Park, Bong-Joon;Kim, Hyo-Chul
    • Journal of Ship and Ocean Technology
    • /
    • 제7권1호
    • /
    • pp.19-28
    • /
    • 2003
  • The systematic results of anti-rolling tanks tests obtained by bench tester and roll test in towing tank have been examined. The effects on the oscillating period of fluid transfer through the duct of U-tube tank due to damper plates and the effects on roll damping moment of the tank due to swash plates are alto evaluated from the results. A simple control algorithm for a forced fluid transfer in U-tube tanks if devised to active operation of the tank by air blower. The active performances of the tank are confirmed very effective through the tank tests carried out in the irregular waves.

Control measures to African swine fever outbreak: active response in South Korea, preparation for the future, and cooperation

  • Kim, Yong-Joo;Park, Bongkyun;Kang, Hae-Eun
    • Journal of Veterinary Science
    • /
    • 제22권1호
    • /
    • pp.13.1-13.14
    • /
    • 2021
  • African swine fever (ASF) is one of the most complex infectious swine diseases and the greatest concern to the pig industry owing to its high mortality and no effective vaccines available to prevent the disease. Since the first outbreak of ASF in pig farms, ASF has been identified in 14 pig farms in four cities/counties in South Korea. The outbreak was resolved in a short period because of the immediate control measures and cooperative efforts. This paper reviews the ASF outbreak and the experience of successfully stopping ASF in pig farms in South Korea through active responses to prevent the spread of ASF. In addition, suitable changes to build a sustainable pig production system and collaborative efforts to overcome the dangerous animal disease, such as ASF, are discussed.

한반도 태풍영향 전·중·후 시기동안 오존농도 변화에 관한 기상특성 분석 (Meteorological Characteristics related to the Variation in Ozone Concentrations before, during, and after the Typhoon Period in the Korean Peninsula)

  • 신현진;송상근
    • 한국환경과학회지
    • /
    • 제26권5호
    • /
    • pp.621-638
    • /
    • 2017
  • Meteorological characteristics related to variations in ozone ($O_3$) concentrations in the Korean peninsula before, during, and after Typhoon Talas (1112) were analyzed using both observation data and numerical modeling. This case study takes into account a high $O_3$ episode (e.g., a daily maximum of ${\geq}90ppb$) without rainfall. Before the typhoon period, high $O_3$ concentrations in the study areas (e.g., Daejeon, Daegu, and Busan) resulted from the combined effects of stable atmospheric conditions with high temperature under a migratory anticyclone (including subsiding air), and wind convergence due to a change in direction caused by the typhoon. The $O_3$ concentrations during the typhoon period decreased around the study area due to very weak photochemical activity under increased cloud cover and active vertical dispersion under a low pressure system. However, the maximum $O_3$ concentrations during this period were somewhat high (similar to those in the normal period extraneous to the typhoon), possibly because of the relatively slow photochemical loss of $O_3$ by a $H_2O+O(^1D)$ reaction resulting from the low air temperature and low relative humidity. The lowest $O_3$ concentrations during the typhoon period were relatively high compared to the period before and after the typhoon, mainly due to the transport effect resulting from the strong nocturnal winds caused by the typhoon. In addition, the $O_3$ increase observed at night in Daegu and Busan was primarily caused by local wind conditions (e.g., mountain winds) and atmospheric stagnation in the wind convergence zone around inland mountains and valleys.

행동궤적의 패턴 분류를 위한 에너지 최소화 모델 (Energy Minimization Model for Pattern Classification of the Movement Tracks)

  • 강진숙;김진숙;차의영
    • 정보처리학회논문지B
    • /
    • 제11B권3호
    • /
    • pp.281-288
    • /
    • 2004
  • 본 논문은 외부 자극에 대한 생물 행동의 복잡하고 다양한 특징들을 추출하고 분석하기 위한 방법을 제안한다. 이를 위해 물 속 생물인 깔따구의 행동궤적으로부터 얻어 낸 속도 벡터의 위상영상에 적응적이고 수리적인 방법인 에너지 최소화 모델을 적용한다. 즉, 다이아지논이라는 약물이 처리되기 전과 후의 깔따구의 행동궤적의 특징을 위상영상으로부터 찾아내어 행동 패턴을 분류하고 이 약물에 대한 깔따구의 적응적 행동 특징을 추출하는 것이다. 특징추출을 위해 도입한 방법은 T. Chan과 L. Vese에 의해 제안된 개선 Active Contour 모델에 근거한 것으로 Active Contour를 진화시키는 과정에서 생성되는 에너지함수 값의 변화를 이용한 것이다. Active Contour 모델이란 주어진 영상에 놓인 커브를 그 커브에 의해 분할된 부분영상들의 에너지 값들의 합을 최소화하는 방향으로 변화하게 함으로써 영상 내 객체의 경계를 찾는 영상분할 방법이다. 깔따구의 행동궤적 데이터는 CCD 카메라를 통해 0.25초 간격으로 약물을 처리하기 전과 후 4일 간을 관찰하여 획득하고, 이 행동궤적 데이터에서 행동의 특징 요소가 되는 속도벡터 성분을 15-20분 간격으로 추출하여 위상영상을 만든다. 그리고 이 위상영상에 Active Contour를 적용함으로써 시간에 따라 감소하는 에너지 함수 값의 그래프에서 구해진 기울기 변화에 대한 수리적 계산과 분석을 통해 깔따구 행동궤적의 특징을 찾고 행동 패턴을 분류한다. 또한, 에너지 최소화 모델은 약물 처리된 깔따구의 반응적인 행동이 이에 적응하고 있음을 효과적으로 보여준다.

조선 중기 이후 서울의 장마철 강수 평균과 극한강수현상의 변화 (Changes in Means and Extreme Events of Changma-Period Precipitation Since mid-Joseon Dynasty in Seoul, Korea)

  • 최광용
    • 대한지리학회지
    • /
    • 제51권1호
    • /
    • pp.23-40
    • /
    • 2016
  • 본 연구에서는 조선시대 측우기(1777~1907년)와 현대적 기상장비(1908~2015년)로 측정한 강우량 자료를 종합 분석하여 서울의 장마철 강수량과 극한강수현상에 나타난 장기간 변화 양상을 밝히고자 하였다. 또한 이와 관련된 동아시아 영역의 종관 기후장에 나타난 변화 특징을 밝히고자 하였다. 약 239년 동안의 서울의 강수자료 시계열을 분석한 결과, 20세기 후반으로 올수록 장마철(6월 하순~9월 초순) 강수량이 증가하고, 경년변동성도 더 커짐을 알 수 있다. 특히 1990년대 초반부터는 장마철 중에서도 여름장마기(6월 하순~7월 중순)와 장마 휴지기(7월 하순~8월 초순)에 극한강수현상 중심의 강수량이 뚜렷하게 증가하면서 장마기의 구분이 모호해지고 있음을 알 수 있다. 이와 관련하여 변화가 뚜렷한 1990년 전후의 상층 종관기후장을 비교해 보면, 최근에는 북서태평양 주변의 해수면 온도가 상승하고 북태평양 아열대 고기압 강도가 강화되어 해양성 기단이 한반도 방향으로 더 확장하고, 유라시아 대륙 내부 몽골 지역을 중심으로 강한 고기압 편차핵이 형성되면서 고위도로부터 기류가 더 활발하게 유입되고 있음을 알 수 있다. 즉, 서로 다른 성질의 기류들이 강해지면서 이들 기류들이 만나는 북서태평양 연안 지역에 상승 기류 흐름이 활발해지면서 최근에는 서울의 장마철 강수평균 및 극한강수현상이 증가하였다고 할 수 있다.

  • PDF

참나무류(類)의 제습태양열건조(除濕太陽熱乾燥)의 조건(條件), 속도(速度), 결함(缺陷), 수율(收率) 및 열효율(熱效率)과 관행(慣行) 천연(天然), 반온실형(半溫室型) 태양열(太陽熱) 및 열기건조(熱氣乾燥)와의 비교(比較)·분석(分析) (The Comparative Analysis of Drying-Conditions, -Rates, -Defects and Yield, and Heat-Efficiency in Solar-Dehumidification-Drying of Oaks With Those in Conventional Air-, Semi-Greenhouse Type solar-, and Kiln- Drying)

  • 이형우;정희석
    • Journal of the Korean Wood Science and Technology
    • /
    • 제17권1호
    • /
    • pp.22-54
    • /
    • 1989
  • Seasonal semi-greenhouse type solar-drying of 2.5cm-and 5.0cm-thick lumber of Quercus aliena Blume and Quercus variailis Blume was carried out to investigate the possibility of solar-drying of wood and to decide the active solar-drying period in Korea. In the active solar-drying period obtained solar-dehumidification, semi-greenhouse type solar-, air- and kiln-drying of 2.5cm -thick lumber of oaks were carried out to analyze drying-rates. -defects, and -yield in each drying-method and to calculate daily total absorbed solar-radiation the solar dryers. The energy balance equations were set up, considering all the energy requirements, to analyze the heat efficiencies of semi-greenhouse type solar and solar-dehumidification-dryer. In a seasonal drying the drying rate of semi-greenhouse type solar-dryer was highest in summer, and greater in fall, spring, and winter in order. Solar-drying time was 45% in summer to 50% in winter of the air-drying rime, and more serious drying-defects occurred in air-drying than in solar-drying. In the active solar-drying period. April, May, and June, the average drying rate in solar-dehumidification-drying was 1.0%/day and greater than 0.8%/day in semi-greenhouse type solar-drying. In solar-dehumidification-drying the time required to dry lumber to 10% moisture content was less than 60 days, and solar-dehumidification-drying showed the highest drying-yield, 65.01%, than the other drying methods. The daily total absorbed solar radiations were 8.51MJ on the roof collector and 6.22 MJ on the south wall collector. In the energy blance 69.48% of total energy input was lost by heat conduction through walls, roof. and floor 11.68% by heat leakage, 0.33% by heating the internal structures of the solar-dryer and 5.38% by air-venting. Therefore the heat efficiency of semi-greenhouse type solar-dryer 13.13%, was lower than that of solar-dehumidification-dryer, 14.04%. Solar-drying of lumber in Korea showed the possibility to reduce the air-drying-time in every season and the efficiency of solar-dehumidification drying was higher than that of semi-greenhouse type solar-drying.

  • PDF